• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
snowbird_poster - Yavuz Lab! - University of Wisconsin–Madison
snowbird_poster - Yavuz Lab! - University of Wisconsin–Madison

Di raction and Interference PRECAUTION
Di raction and Interference PRECAUTION

New Developments in Transmission Electron Microscopy for
New Developments in Transmission Electron Microscopy for

... Cubic and tetrahedral are the two most typical shapes for the Pt nanocrystals. We now apply in-situ TEM to determine the stability of particle shapes and the melting behavior. Figure 1 shows a series of TEM images recorded from the same region when the specimen temperature was increased from 25 to 6 ...
Imaging and Non-imaging System Modeling in ASAP
Imaging and Non-imaging System Modeling in ASAP

... interrelated and the total system performance is dependent on both systems. In addition to industry requirements, today’s LCD projectors must conform to mechanical (styling), electrical, manufacturing, weight, and cost requirements. The principal performance requirements of the LCD projector are tot ...
Modeling phase microscopy of transparent three
Modeling phase microscopy of transparent three

Total internal reflection microscopy studies on colloidal particle
Total internal reflection microscopy studies on colloidal particle

... The purpose of this study was to develop novel optical microscopy techniques in order to investigate colloidal drug particle endocytosis by mammalian cells. A total internal reflection microscope (TIRM) was initially developed for high resolution cellular imaging. TIRM is a non-fluorescent imaging t ...
incoherent
incoherent

... 11/10/04 wk10-b-10 ...
1.9 W yellow, CW, high-brightness light from a high efficiency
1.9 W yellow, CW, high-brightness light from a high efficiency

Spectral Domain Optical Coherence Tomography
Spectral Domain Optical Coherence Tomography

... in the reference arm, the phase stability is greatly improved. Spectral domain optical Doppler tomography allows real-time imaging of pulsatile blood flow within blood vessels as small as 10 µm and as deep as the choroid.11,18 Spectral domain optical coherence tomography’s higher acquisition speeds ...
Proposal and testing of dual-beam dynamic light
Proposal and testing of dual-beam dynamic light

... To overcome the experimental difficulties, Crocker et al.13 recently developed two-particle microrheology, which measures the relative diffusion of tracer particle pairs within the sample. The correlated motion of the particle pairs depends only on the separation l between the particles and is inde ...
RIT - People - Rochester Institute of Technology
RIT - People - Rochester Institute of Technology

Diode Laser Characteristics
Diode Laser Characteristics

1 - FunFACS
1 - FunFACS

... of propagation is still to be clarified. Under very similar experimental conditions, INLN was also able to show the motion of a single structure, oscillating around a fixed center (see Figs. 3.3 and 3.4). Applying an external perturbation, it was possible to trigger the departure of this structure f ...
Diffraction - Purdue Physics
Diffraction - Purdue Physics

Phase contrast and DIC - Nikon Imaging Center at UCSF
Phase contrast and DIC - Nikon Imaging Center at UCSF

... Solution: sum shifted wave with some reference ...
Design and Simulation of DPSS Laser with SHG for Material
Design and Simulation of DPSS Laser with SHG for Material

Polarization spectra of excited-state-Mg(3p)--rare-gas
Polarization spectra of excited-state-Mg(3p)--rare-gas

... two to eight (depending on the signal-to-noise ratio) single data runs were averaged to obtain the polarization at that detuning. Measured polarization values were independent of Mg density and the intensity of either laser 1 or laser 2. As described previously, systematic efFects on the measured po ...
Kuhnke Laser Shutter DS200X8 - Kendrion Kuhnke Automation GmbH
Kuhnke Laser Shutter DS200X8 - Kendrion Kuhnke Automation GmbH

Optical tweezers using a diode laser
Optical tweezers using a diode laser

- Free Documents
- Free Documents

... sometimes called loss A natural consequence of signal transmission over long distances The extent of attenuation is usually expressed in dB dB a common unit of measurement for the relative difference between two power levels dB logPout / Pin log Pout .Optical Parameters Attenuation refers to any red ...
Deep subwavelength nanolithography using localized surface plasmon modes on
Deep subwavelength nanolithography using localized surface plasmon modes on

r 5 fs hinner ljuset färdas 1
r 5 fs hinner ljuset färdas 1

... Make sure that the laser beam is blocked (i.e. by a power meter)! The instructor will show you how to modelock the laser. What happens to the output power as the laser is modelocked? Why? The curved mirror CM2 focus the spontaneous emission from the crystal. Measure the distance from the focus to th ...
All solid-state continuous wave tunable blue light source by
All solid-state continuous wave tunable blue light source by

In-fiber microchannel device filled with a carbon
In-fiber microchannel device filled with a carbon

Polarization effects and the calibration of a donut beam axial optical
Polarization effects and the calibration of a donut beam axial optical

... where φ is the azimuthal angle and l is an integer representing the topological charge. The result is a helical wave front with a phase singularity at the centre that produces a dark region along the optical axis. A more flexible way to introduce a spiral phase is with a phase-only spatial light mod ...
< 1 ... 25 26 27 28 29 30 31 32 33 ... 61 >

Super-resolution microscopy

Super-resolution microscopy is a form of light microscopy. Due to the diffraction of light, the resolution of conventional light microscopy is limited as stated by Ernst Abbe in 1873. A good approximation of the resolution attainable is the full width at half maximum (FWHM) of the point spread function, and a precise widefield microscope with high numerical aperture and visible light usually reaches a resolution of ~250 nm.Super-resolution techniques allow the capture of images with a higher resolution than the diffraction limit. They fall into two broad categories, ""true"" super-resolution techniques, which capture information contained in evanescent waves, and ""functional"" super-resolution techniques, which use clever experimental techniques and known limitations on the matter being imaged to reconstruct a super-resolution image.True subwavelength imaging techniques include those that utilize the Pendry Superlens and near field scanning optical microscopy, the 4Pi Microscope and structured illumination microscopy technologies like SIM and SMI. However, the majority of techniques of importance in biological imaging fall into the functional category.There are two major groups of methods for functional super-resolution microscopy: Deterministic super-resolution: The most commonly used emitters in biological microscopy, fluorophores, show a nonlinear response to excitation, and this nonlinear response can be exploited to enhance resolution. These methods include STED, GSD, RESOLFT and SSIM. Stochastic super-resolution: The chemical complexity of many molecular light sources gives them a complex temporal behaviour, which can be used to make several close-by fluorophores emit light at separate times and thereby become resolvable in time. These methods include SOFI and all single-molecule localization methods (SMLM) such as SPDM, SPDMphymod, PALM, FPALM, STORM and dSTORM.On October 8th, 2014, the Nobel Prize in Chemistry was awarded to Eric Betzig, W.E. Moerner and Stefan Hell for ""the development of super-resolved fluorescence microscopy,"" which brings ""optical microscopy into the nanodimension"".
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report