Q1 - Texas Instruments
... half-duplex (two-wire bus) communication. This port features a wide common-mode voltage range, making the devices suitable for multipoint applications over long cable runs. These devices are characterized from –40°C to 125°C. These devices are pincompatible with the industry-standard SN75176 transce ...
... half-duplex (two-wire bus) communication. This port features a wide common-mode voltage range, making the devices suitable for multipoint applications over long cable runs. These devices are characterized from –40°C to 125°C. These devices are pincompatible with the industry-standard SN75176 transce ...
LM137/LM337 3-Terminal Adjustable Negative Regulators (Rev. E)
... circuit components. With an IC regulator, this gradient can be especially severe because power dissipation is large. Thermal regulation is the effect of these temperature gradients on output voltage (in percentage output change) per Watt of power change in a specified time. Thermal regulation error ...
... circuit components. With an IC regulator, this gradient can be especially severe because power dissipation is large. Thermal regulation is the effect of these temperature gradients on output voltage (in percentage output change) per Watt of power change in a specified time. Thermal regulation error ...
Multimeter
... where Rx is the test resistor, and Ig is the current passing through the galvanometer. The scale is nonlinear because, according to Formula (12), the relationship between Ig and Rx is nonlinear. ...
... where Rx is the test resistor, and Ig is the current passing through the galvanometer. The scale is nonlinear because, according to Formula (12), the relationship between Ig and Rx is nonlinear. ...
Discussion on lightning impulse test procedure
... "The impedance of some windings may be so low that the desired time to the 50% voltage point on the tail of the wave can not be obtained with available test equipment. For such cases, shorter waves are considered acceptable provided that: 1- The optimum impulse generator connection is used (use of p ...
... "The impedance of some windings may be so low that the desired time to the 50% voltage point on the tail of the wave can not be obtained with available test equipment. For such cases, shorter waves are considered acceptable provided that: 1- The optimum impulse generator connection is used (use of p ...
Guidelines For Electrical Wiring In Residential
... switching, together with the protection system which are needed in every domestic wiring installation. ...
... switching, together with the protection system which are needed in every domestic wiring installation. ...
TL4242-Q1 数据资料 dataSheet 下载
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
... obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI’s terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the speci ...
MAX3384E ±15kV ESD-Protected, 3.0V to 5.5V, Low-Power, ________________General Description
... 3b shows the current waveform it generates when discharged into a low impedance. This model consists of a 100pF capacitor charged to the ESD voltage of interest, which is then discharged into the test device through a 1.5kΩ resistor. IEC 1000-4-2 The IEC 1000-4-2 standard covers ESD testing and perf ...
... 3b shows the current waveform it generates when discharged into a low impedance. This model consists of a 100pF capacitor charged to the ESD voltage of interest, which is then discharged into the test device through a 1.5kΩ resistor. IEC 1000-4-2 The IEC 1000-4-2 standard covers ESD testing and perf ...
Diagnosing Integrator Leakage of Single-Bit First
... (ADC) technique, especially for audio and communication applications that require high-resolution analog-to-digital interfaces. Due to its simple configuration and oversampling nature, a ∆Σ modulator can tolerate relatively high process variations and matching inaccuracy without failing its functiona ...
... (ADC) technique, especially for audio and communication applications that require high-resolution analog-to-digital interfaces. Due to its simple configuration and oversampling nature, a ∆Σ modulator can tolerate relatively high process variations and matching inaccuracy without failing its functiona ...
Chrysler Evaporative Leak Detection Systems
... Low ambient temp: under 19 degrees F Low battery voltage: under 11 volts Fuel tank level below 12% or over 88% ...
... Low ambient temp: under 19 degrees F Low battery voltage: under 11 volts Fuel tank level below 12% or over 88% ...
BAUR cable testing and diagnostics.
... truesinus® voltage source of the latest generation and the most powerful generator of the VLF family. The PHG system satisfies the highest requirements with respect to security, robustness, convenience of operation, automation and documentation. The PHG can be used for testing plastic and paper-mass ...
... truesinus® voltage source of the latest generation and the most powerful generator of the VLF family. The PHG system satisfies the highest requirements with respect to security, robustness, convenience of operation, automation and documentation. The PHG can be used for testing plastic and paper-mass ...
S260-15-2
... is a single-pole, double-throw switch (three-wire control) supplied by the customer. Any manual switch, time switch, voltage-, current- or photo-electric-controlled switch, or similar device can be used, provided the control circuit is energized for a minimum of 50 milliseconds for each operation. A ...
... is a single-pole, double-throw switch (three-wire control) supplied by the customer. Any manual switch, time switch, voltage-, current- or photo-electric-controlled switch, or similar device can be used, provided the control circuit is energized for a minimum of 50 milliseconds for each operation. A ...
Measurement and Error - New Age International
... (i) Accuracy: It refers to the closeness of an instrument reading to the true value of the quantity or variable under measurement. This term describes the algebraic difference between the indicated value and the true value or theoretical value of the measurand. In practice, accuracy is usually expre ...
... (i) Accuracy: It refers to the closeness of an instrument reading to the true value of the quantity or variable under measurement. This term describes the algebraic difference between the indicated value and the true value or theoretical value of the measurand. In practice, accuracy is usually expre ...
User Manual - Marlin P. Jones
... LC100-A has four measuring range position: 1. C range ........Capacitance (0.01pF-10uF) 2. L range ........Inductance (0.001uH-100mH) 3. Hi.L range ......High inductance (0.001mH-100H) 4. Hi.C range ......High capacitance range (1uF-100mF) Automatic measuring ranges, it is easy to operate. Specifica ...
... LC100-A has four measuring range position: 1. C range ........Capacitance (0.01pF-10uF) 2. L range ........Inductance (0.001uH-100mH) 3. Hi.L range ......High inductance (0.001mH-100H) 4. Hi.C range ......High capacitance range (1uF-100mF) Automatic measuring ranges, it is easy to operate. Specifica ...
New York State Electric Meter Engineers` Committee Guide for
... transformers. The condition of in-service CT’s can be periodically checked by use of one of two methods. The preferred method for the detection of abnormal conditions is to monitor the CT’s admittance. An increase of sufficient magnitude would indicate an abnormal condition such as an error or fault ...
... transformers. The condition of in-service CT’s can be periodically checked by use of one of two methods. The preferred method for the detection of abnormal conditions is to monitor the CT’s admittance. An increase of sufficient magnitude would indicate an abnormal condition such as an error or fault ...
SEL-411L. - My Protection Guide
... Step1: Set ‘EOCTL’ =N, EDD=N, to avoid blocking of 87L2,87LG and blocking due to slow change in current. Step2: Set 87L2P=OFF and 87LGP =OFF, while testing 87LP, Do the same while testing others. Step3: Increase current on one phase until relay trips on 87. Repeat the same for other phases. Step4: T ...
... Step1: Set ‘EOCTL’ =N, EDD=N, to avoid blocking of 87L2,87LG and blocking due to slow change in current. Step2: Set 87L2P=OFF and 87LGP =OFF, while testing 87LP, Do the same while testing others. Step3: Increase current on one phase until relay trips on 87. Repeat the same for other phases. Step4: T ...
Automatic test equipment

Automatic or automated test equipment (ATE) is any apparatus that performs tests on a device, known as the Device Under Test (DUT), Equipment Under Test (EUT) or Unit Under Test (UUT), using automation to quickly perform measurements and evaluate the test results. An ATE can be a simple computer controlled digital multimeter, or a complicated system containing dozens of complex test instruments (real or simulated electronic test equipment) capable of automatically testing and diagnosing faults in sophisticated electronic packaged parts or on Wafer testing, including System-On-Chips and Integrated circuits.