• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
LDS8681 - IXYS Power
LDS8681 - IXYS Power

... use of multiple via. A copper area matching the TDFN exposed pad (PAD) must be connected to the ground plane underneath. The use of multiple via improves the package heat dissipation (see figure below). The ground plane on the top layer is connected to the ...
12 VOLT AC/DC POWER SUPPLY
12 VOLT AC/DC POWER SUPPLY

... ➤Caution: AC and DC outputs are not independently floating. Cross-connection could result in internal damage ...
Effects of Stray Capacitance to Ground in Three
Effects of Stray Capacitance to Ground in Three

ZXTN2010A 60V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN E-LINE SUMMARY BV
ZXTN2010A 60V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN E-LINE SUMMARY BV

... Fax: (49) 89 45 49 49 49 [email protected] ...
AN2063 - STMicroelectronics
AN2063 - STMicroelectronics

Electric Circuits
Electric Circuits

... MS-PS2-5. Conduct an investigation and evaluate the experimental design to provide evidence that fields exist between objects exerting forces on each other even though the objects are not in contact. ...
FJV3114R NPN Epitaxial Silicon Transistor
FJV3114R NPN Epitaxial Silicon Transistor

Application Note #1435 100
Application Note #1435 100

... Application Note #1435 Protecting Encoder Input Circuitry If there are voltage spikes which are damaging the line receiver inputs of the Galil controller, the input circuit may be protected by placing 2 diodes on every encoder input that is used on the controller (CHA, CHB, CHA-, CHB-). The procedur ...
“Real” Transformer
“Real” Transformer

... Define ZeqP = The “equivalent impedance” with all parameters referred to the primary ...
Part 1
Part 1

... Lightning strikes amateur towers and antennas NO MORE frequently than tall trees or other structures. ...
Theoretical Design
Theoretical Design

... Acquisition Software Project Record). Instead of outputting data on pulse height and width, the circuit only needs to output a “yes or no” signal as to if there was a pulse or not. The circuit is designed to accomplish this by using an op amp comparator to distinguish between the pulse signal in the ...
An Introduction to AC Signals and Their Measurement
An Introduction to AC Signals and Their Measurement

... mentioning here. Multimeters usually can only measure one signal at a time, while oscilloscopes usually have more (ours can measure four). On the other hand, multimeters have floating inputs; that is, they directly measure the voltage difference between the two inputs, which can be connected to any ...
Performance analysis of Effects of Parasitic Elements on the
Performance analysis of Effects of Parasitic Elements on the

#2093
#2093

... The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information th ...
2SD1047
2SD1047

... Information in this document is provided solely in connection with ST products. STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, modifications or improvements, to this document, and the products and services described herein at any time, without notic ...
CN0233: 16位工业、隔离电压电流输出的DAC,同时提供隔离的DC-DC电源 .
CN0233: 16位工业、隔离电压电流输出的DAC,同时提供隔离的DC-DC电源 .

... Solutions based on opto-isolators typically have reasonable output regulation but require additional external components, thereby increasing board area. Power modules are often bulky and may provide poor output regulation. The circuit in Figure 1 is based on the ADuM347x family of isolators (ADuM347 ...
Ideal Transformers
Ideal Transformers

A Carrier-Based PWM Strategy With the Offset Voltage Injection for
A Carrier-Based PWM Strategy With the Offset Voltage Injection for

- Mitra.ac.in
- Mitra.ac.in

... (b) List out the electrical characteristics of an ideal Op-Amp. 3. (a) what is the necessity of constant current source? What are the different means to realize constant current sources? Explain with neat circuit diagram. (b) Explain and Derive the exact equation for Output Voltage of Closed Loop In ...
ASNT1012 Reconfigurable MUX CMU
ASNT1012 Reconfigurable MUX CMU

... ASNT6114-KMC is a temperature stable active analog signal splitter 1-to-2 and is intended for use in highspeed interleaved ADC or similar systems. The IC shown in Fig. 1 can receive a broad-band analog signal at its differential input “dp/dn” and effectively distribute it to two separate phase match ...
power factor correction filters with static switching fre series
power factor correction filters with static switching fre series

... instead of the contactors used in the conventional equipment for PF compensation. The static switches allow the connection and disconnection of capacitors without any transients and thus the FRE equipment is specially suitable for the power factor compensation in installations having high harmonic c ...
PUB-NP-092 Please describe what Newfoundland Power’s capabilities in voltage reduction are: Q.
PUB-NP-092 Please describe what Newfoundland Power’s capabilities in voltage reduction are: Q.

... Newfoundland Power exercises its voltage reduction capabilities to be within the voltage variation limits of CSA Standard CAN3-C235-83 to ensure acceptable voltage levels are maintained with customers. The level of voltage reduction and the number of steps utilized to achieve reduced voltage operati ...
HMC358MS8G - Hittite Microwave Corporation
HMC358MS8G - Hittite Microwave Corporation

... [1] Reference this number when ordering complete evaluation PCB [2] Circuit Board Material: Rogers 4350 ...
a AN-423 APPLICATION NOTE •
a AN-423 APPLICATION NOTE •

���������������� ������ - Noor Technology for General Trading, Contracting
���������������� ������ - Noor Technology for General Trading, Contracting

... fans and small conveyors, the compact DS7 is ideal. The DS7 will soon be available with a SmartWire-DT connection to simplify wiring and enhance functionality as an automation solution. ...
< 1 ... 391 392 393 394 395 396 397 398 399 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report