• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
electrical theory and application
electrical theory and application

TLE4250-2G
TLE4250-2G

... The overtemperature protection circuit prevents the IC from immediate destruction under fault conditions (e. g. output continuously short-circuited) by reducing the output current. A thermal balance below 200 °C junction temperature is established. Please note that a junction temperature above 150 ° ...
HW 4
HW 4

Protected against direct spray of water from all - Consultations
Protected against direct spray of water from all - Consultations

... so as to prevent danger, and (b) all electrical equipment and electrical installations, including distribution boards, sockets, transformers and connections, are suitably protected from ingress of moisture or of particles and foreseeable impacts, as appropriate to the location. 3.2 Design and constr ...
CITY OF RANCHO SANTA MARGARITA
CITY OF RANCHO SANTA MARGARITA

... AC inverter output rating of 10 kW, with a maximum of 3 branch circuits, one PV module per inverter and with PV module ISC maximum of 10-A DC, installed on a roof of a one- or two-family dwelling or accessory structure. The photovoltaic system must interconnect to a single-phase AC service panel of ...
Harmonics in your electrical system
Harmonics in your electrical system

... In the typical data center, the power distribution system converts 480-volt AC utility power through a transformer that steps it down to 208-volt AC power that feeds racks of servers. One or more power supplies within each server convert this AC input into DC voltage appropriate for the unit’s inter ...
Simulation and Analysis of Faults in High Voltage DC
Simulation and Analysis of Faults in High Voltage DC

... future trend in bulk power transmission [1]. The transmission losses and the capital investments are eventually higher for AC systems beyond certain distance, e.g., typically about 700 KM for overhead and 40 KM for underground lines [2]. Direct connection between two AC systems with different freque ...
EES005 Electrical Protection and Earthing Guideline
EES005 Electrical Protection and Earthing Guideline

... conductors insulated from one another and which is designed to afford relative motion between its terminal points while it is energised. Main earth leakage. Earth leakage protection that is expected to operate first under fault conditions – the earth leakage protection generally installed to protect ...
EMC-240B - Tii Technologies Inc.
EMC-240B - Tii Technologies Inc.

... Max Allowable Voltage (L-N) 150V rms 50-60Hz Max Allowable Voltage (L-L) 275V rms 50-60 Hz Failure Mode Failsafe (short) and Fused Failure Indication LED Indicators Surge Life @ 500A >10,000 Occurrences Surge Life @ 2,000A >1,000 Occurrences Surge Life @ 5,000A >300 Occurrences Surge Life @ 10,000A ...
ZXTN2007Z 30V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN SOT89 SUMMARY BV
ZXTN2007Z 30V NPN LOW SATURATION MEDIUM POWER TRANSISTOR IN SOT89 SUMMARY BV

... Fax: (49) 89 45 49 49 49 [email protected] ...
Application notes AN1015 current loop output
Application notes AN1015 current loop output

... applications require that the measurement signal be converted into a suitable standard analog signal for further processing (signal transmission). The reasons for this lie in the simple handling of signal transmission, in the technical limitations of digital buses and/or in the considerable economic ...
svc
svc

... the SVC. Air core reactors are most commonly applied. The inductance value of the reactors is custom designed for each system in order to satisfy the specified reactive power output. ...
Charge Sharing by Capacitors
Charge Sharing by Capacitors

... When S2 is closed, there can be no voltage across it, but Kirchhoff's Second Rule must still hold. The capacitors discharge partially in order to satisfy this. Let the initial charges (before closing S2) of C3 and C4 be Q3 and Q4. Let the final charges (after closing S2) be Q3' and Q4'. Let the fina ...
TITLE Theoretical Foundations of Electrical Engineering ECTS
TITLE Theoretical Foundations of Electrical Engineering ECTS

... Module 6. Electrostatic fields in dielectric mediums. Electrostatic fields in conducting mediums. Magnetic field of DC. Alternating electromagnetic field in stationary medium. Study-unit Aims: Creation of adequate mathematical models of electromagnetic phenomena, an experimental study of the peculia ...
1 ET 150 Exam 1 Study Guide Written Test Learning Objectives To
1 ET 150 Exam 1 Study Guide Written Test Learning Objectives To

... 50.) List three things found in electronic component data sheets. 51.) Identify pin 1 on and IC package. 52.) Given an IC package connection diagram, identify pin function. 53.) List three voltage measures used with Ac waveforms. 54.) Given a peak-to-peak voltage measurement of a sine wave, find its ...
PHYSICS 176 UNIVERSITY PHYSICS LAB II Experiment 4
PHYSICS 176 UNIVERSITY PHYSICS LAB II Experiment 4

... In the days when vacuum tube circuits were common, the tube filament was heated (to boil off electrons form the tube cathode) by passing an A.C. current through it. The A.C. voltage across the filament was derived from the secondary winding of a filament transformer. The A.C. voltage across the prim ...
KA319 Dual Comparator Features Description
KA319 Dual Comparator Features Description

... CORPORATION. As used herein: 1. Life support devices or systems are devices or systems which, (a) are intended for surgical implant into the body, or (b) support or sustain life, and (c) whose failure to perform when properly used in accordance with instructions for use provided in the labeling, can ...
PHYSICS 171 UNIVERSITY PHYSICS LAB II Experiment 4
PHYSICS 171 UNIVERSITY PHYSICS LAB II Experiment 4

... In the days when vacuum tube circuits were common, the tube filament was heated (to boil off electrons form the tube cathode) by passing an A.C. current through it. The A.C. voltage across the filament was derived from the secondary winding of a filament transformer. The A.C. voltage across the prim ...
THREE PHASE TRANSFORMERS
THREE PHASE TRANSFORMERS

... three legs are "bent" when the phase diagram is drawn. Zigzag-wound transformers have special characteristics and are not commonly used where these characteristics are not needed. ...
Rarely Asked Questions (Observing Maximum Ratings or How to
Rarely Asked Questions (Observing Maximum Ratings or How to

thus, online fault diagnosis of the power inverter is
thus, online fault diagnosis of the power inverter is

... Magnetically suspended control moment gyro (MSCMG) is considered to be the key actuators for the attitude control of space stations, satellites, etc. It has the character of high precision, large moment, and long life owing to the zero friction and enhanced damping of high-speed rotor. Since the ope ...
PM1000 series power meter and DM6000 series
PM1000 series power meter and DM6000 series

... PM1000 series power meter Functions and characteristics The PowerLogic PM1000 series power meters are easy-to-use, cost-effective meters that offer the basic measurement capabilities required to monitor an electrical installation. Characterized by their rugged construction, compact size and low in ...
Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality
Liebert Precision Power Center Packaged Power Distribution For Higher Power Quality

Series Circuit Answers
Series Circuit Answers

... 9a) Draw lines to represent conductors on the Circuit Pictures in order to com plete the circuits shown the Schem atic Diagram . b) Assum e power supply produces 6 am peres and 12 volts, write the expected readings beside each m eter ...
Modelling and Analysis of Controller for Three
Modelling and Analysis of Controller for Three

... The Active filters are generally used at harmonic producing loads. Among all APF’s the Shunt Active Power Filter (SAPF) is more prominent at medium/high voltage applications, and also it provides higher efficiency. SAPF in the power circuit can be used either by using the voltage-sourced PWM convert ...
< 1 ... 394 395 396 397 398 399 400 401 402 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report