• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
PCBlyt-hmnt-audio+EMC+T-100423
PCBlyt-hmnt-audio+EMC+T-100423

... Ground Loops Cont’d. • Interference in a single-ended input with high ground impedance to its source can be high. • One way to avoid this is to separate ground currents so they cannot interfere. • If this is not possible make the impedance of the ground path between a single-ended input and its sou ...
Current-Only Directional Overcurrent Relay
Current-Only Directional Overcurrent Relay

... protection of power transmission systems. Distributionside protection, e.g., for radial and ring-main units [2], mostly employs non-directional relays. Here, a fault generally means an overcurrent [3], mainly from a short circuit. The nondirectional relay typically monitors the overcurrent (from the ...
Digital Power Monitoring Solutions
Digital Power Monitoring Solutions

... Intersil’s Digital Power Monitoring Solutions Intersil’s Digital Power Monitoring (DPM) devices provide a bi-directional high-side and low-side digital current sense and voltage monitor with serial interface. The device monitors current and voltage and provides the results digitally along with calcu ...
SCR Timing and the Zero Crossing
SCR Timing and the Zero Crossing

... current from one winding of a transformer and allow current to flow to another winding on a transformer. This can be accomplished many ways; one of these ways is by the use of a contactor. Contactors usually have a switch time of around 12ms 20ms; so once the detection circuit says, "switch to anoth ...
Electric Circuits – Resistors in Parallel
Electric Circuits – Resistors in Parallel

Low Voltage Lights Installation Instructions
Low Voltage Lights Installation Instructions

III. UPQC - Academic Science,International Journal of Computer
III. UPQC - Academic Science,International Journal of Computer

voltage increase
voltage increase

... in both conductors As percentage voltage increases, efficiency increase for given voltage drop Due to increase of voltage by n times, current in line is reduced n times, so line loss is reduced n2 times. Hence to transmit power with same losses, resistance of line can be increase by n2 times i.e. am ...
No Slide Title
No Slide Title

... • Electromagnetic induction – The action caused when two electrically isolated coils are placed next to each other and an AC voltage is put across one coil, resulting in a changing magnetic field which induces a voltage into the second coil.. – The device used to create this action is called a tran ...
ElEctrical SafEty
ElEctrical SafEty

... conductor - material in which an electrical current moves easily CPR - cardiopulmonary resuscitation-emergency procedure that involves giving artificial breathing and heart massage to someone who is not breathing or does not have a pulse (requires special training) current - movement of electrical c ...
50A-3PH 3 Phase Current Injection System
50A-3PH 3 Phase Current Injection System

... The contact circuit has an open circuit voltage of 24Vdc and a short circuit current of 20mA. Each contact circuit will autoselect for normally open or normally closed contacts. A DC voltage of 24-240Vdc may also be used to trigger either timer channel. The output is automatically switched off at th ...
KVL Example Resistor Voltage Divider • Consider a series of
KVL Example Resistor Voltage Divider • Consider a series of

1)______ types of Induction Motor are widely used. A. SlipringIM B
1)______ types of Induction Motor are widely used. A. SlipringIM B

... B. series reactors& shunt capacitors C. Synchronous condensers D. Tap- changing Transformers 54) A compensated wattmeter has its reading corrected for error due to theA. Frequency B. friction C. power consumed in potential coil D. power consumed in current coil 55) A long wire composed of a smooth ...
Soldering and installation instructions. Assembling.
Soldering and installation instructions. Assembling.

... Connect the antenna unit. Measure the following voltages in the antenna PCB. Their value can differ with different supply voltages and adjustment if T1 dian current : C6=12,3V , C5=11,2V , R4=3,0V +-20% , R9=5,57V. By adapting the value of R2a, the quiescent drain current of T1 can be adjusted (20mA ...
FS-TRI-S - Fire Alarm Resources
FS-TRI-S - Fire Alarm Resources

... WIRING BARRIER FOR FS-TRI-R RELAY CONTACTS The wiring barrier must be used when the FS-TRI-R relay contacts are connected to non-power limited wires. Install the barrier diagonally into the backbox to create two separate compartments within the backbox to separate the wires, as shown in Figure 2. ...
Measuring Biased Inductors
Measuring Biased Inductors

... Dangerous voltages are generated if connections are broken while the current is flowing. Always set all power sources to zero output before making or breaking connections. Limit supply voltages to 60V or less. Use redundant safety measures to greatly reduce the shock hazard to the operator and avoid ...
HV Vacuum circuit-breakers: Challenges of capacitive load
HV Vacuum circuit-breakers: Challenges of capacitive load

... The capacitive current switching of unloaded lines and cables is an application using requiring comparably low currents up to a few hundred amps. The dielectric stress after current zero represents the main challenge for the circuit breaker. This dielectric stress results from the nearly fully charg ...
G-TYPE user leaflet G-TYPE user leaflet
G-TYPE user leaflet G-TYPE user leaflet

TDA9103 USER`S MANUAL DEMONSTRATION BOARD
TDA9103 USER`S MANUAL DEMONSTRATION BOARD

... Information furnished is believed to be accurate and reliable. However, SGS-THOMSON Microelectronics assumes no responsibility for the consequences of use of such information nor for any infringement of patents or other rights of third parties which may result from its use. No licence is granted by ...
Document
Document

IS31LT3135 - Integrated Silicon Solution
IS31LT3135 - Integrated Silicon Solution

... channel and the sub channel can switch between each other. Sweeping power supply from high voltage to low voltage, main channel switches to sub-channel while UV pin is below the undervoltage threshold 1.17V (IS31LT3135-V1 typical) or 1.23V (IS31LT3135-V2 typical). Sweeping power supply from low volt ...
View/Open - Library@Atmiya
View/Open - Library@Atmiya

... Have implemented in the construction of inverter single phase will also be Provided. This project is can use for the small places, camping area and Other a place is same thing it. So, that why we develop this project. By do this Project also we can learn many more about a new thing. ...
Phantom Power and Bias Voltage: Is There A Difference
Phantom Power and Bias Voltage: Is There A Difference

... Phantom power is a dc voltage (11 - 48 volts) which powers the preamplifier of a condenser microphone. Phantom power is normally supplied by the microphone mixer, but may also be supplied by a separate phantom power supply. Phantom requires a balanced circuit in which XLR pins 2 and 3 carry the same ...
Electric Current and Circuits Basketball Jeopardy
Electric Current and Circuits Basketball Jeopardy

pdfnew/aob2og01?
pdfnew/aob2og01?

... microphone on stage feeding a console input is an example of half of a four-wire circuit. It would not usually be called such, since it is not an intercom use, but it remains one-half of a communications path from the stage to the intended listeners. The reverse path, for example the console’s talk- ...
< 1 ... 397 398 399 400 401 402 403 404 405 ... 584 >

Ground (electricity)



In electrical engineering, ground or earth is the reference point in an electrical circuit from which voltages are measured, a common return path for electric current, or a direct physical connection to the Earth.Electrical circuits may be connected to ground (earth) for several reasons. In mains powered equipment, exposed metal parts are connected to ground to prevent user contact with dangerous voltage if electrical insulation fails. Connections to ground limit the build-up of static electricity when handling flammable products or electrostatic-sensitive devices. In some telegraph and power transmission circuits, the earth itself can be used as one conductor of the circuit, saving the cost of installing a separate return conductor (see single-wire earth return).For measurement purposes, the Earth serves as a (reasonably) constant potential reference against which other potentials can be measured. An electrical ground system should have an appropriate current-carrying capability to serve as an adequate zero-voltage reference level. In electronic circuit theory, a ""ground"" is usually idealized as an infinite source or sink for charge, which can absorb an unlimited amount of current without changing its potential. Where a real ground connection has a significant resistance, the approximation of zero potential is no longer valid. Stray voltages or earth potential rise effects will occur, which may create noise in signals or if large enough will produce an electric shock hazard.The use of the term ground (or earth) is so common in electrical and electronics applications that circuits in portable electronic devices such as cell phones and media players as well as circuits in vehicles may be spoken of as having a ""ground"" connection without any actual connection to the Earth, despite ""common"" being a more appropriate term for such a connection. This is usually a large conductor attached to one side of the power supply (such as the ""ground plane"" on a printed circuit board) which serves as the common return path for current from many different components in the circuit.
  • studyres.com © 2026
  • DMCA
  • Privacy
  • Terms
  • Report