Download PUB-NP-092 Please describe what Newfoundland Power’s capabilities in voltage reduction are: Q.
Ground loop (electricity) wikipedia , lookup
Audio power wikipedia , lookup
Electrification wikipedia , lookup
Spark-gap transmitter wikipedia , lookup
Electric power system wikipedia , lookup
Stepper motor wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Ground (electricity) wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Current source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Opto-isolator wikipedia , lookup
Schmitt trigger wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power MOSFET wikipedia , lookup
Power electronics wikipedia , lookup
Electrical substation wikipedia , lookup
Buck converter wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Requests for Information PUB-NP-092 Supply Issues and Power Outages on the Island Interconnected System Page 1 of 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Q. Please describe what Newfoundland Power’s capabilities in voltage reduction are: one step of 8-percent, two steps of 4-percent, or what else. A. Newfoundland Power exercises its voltage reduction capabilities to be within the voltage variation limits of CSA Standard CAN3-C235-83 to ensure acceptable voltage levels are maintained with customers. The level of voltage reduction and the number of steps utilized to achieve reduced voltage operation will vary by location.1 Newfoundland Power exercises voltage reduction in three ways. These include (i) requesting Newfoundland and Labrador Hydro to adjust voltage at Newfoundland Power’s power purchase supply locations; (ii) implementing pre-programmed voltage reduction settings via its SCADA system; and (iii) by manually operating voltage regulating equipment at the substation. A request made to Newfoundland and Labrador Hydro to lower voltage levels at Newfoundland Power’s power purchase supply locations is typically done in two stages. Initially a 3% voltage reduction is requested followed by a further 2% reduction, if required. Newfoundland Power implements its automated voltage reduction capabilities via its SCADA system. This voltage reduction capability consists of remotely operating voltage regulating equipment in 14 substations from the Company’s System Control Center. Up to three stages of voltage reduction can be implemented remotely. The voltage reduction achieved with each stage can vary depending on the characteristics of the distribution feeders served by the transformer. The voltage reduction initiated is typically 2% or 3%, up to a maximum 7% overall voltage reduction. The average overall voltage reduction achieved from all stages is approximately 5%. Voltage reduction is conducted manually in some locations by operating voltage regulating equipment within some of the Company’s substations. The voltage is typically reduced by between 3% and 7%. 1 For example, the length and electrical load on a distribution feeder will impact the voltage reduction exercised to maintain CSA standards. Longer distribution feeders or distribution feeders with a large electrical load will have a greater voltage drop between the beginning and end of the distribution feeder. This limits the amount of voltage reduction that can be achieved in order to maintain CSA standards. Newfoundland Power