Safety Document (Risk Assessment) Faculty of Electrical and Electronic Engineering Department of Electrical Power Engineering High Voltage Laboratory Title of Experiment / Test:Project / Academic Supervisor:- Person Carrying Out The Experiment Name:Matrix No:Contact No:Email:- Safety Documents Valid From:- ______________ To:- ______________ For continuous periods of experimentation only. Re-validation of this document is required for breaks in experimentation greater than one month or when test circuit is dismantled and re-assembled. Level of Supervision: Choose one and tick ‘X’ (to be completed by Supervisor / Head of Laboratory) Experimentation to be carried out in presence of student’s Supervisor Experimentation may be carried out providing AE / HoL is in the laboratory *Head of Laboratory (HoL) or Assistant Engineer (AE) must always be in the laboratory to permit experimentation to take place in the laboratory. SACTION TO EXPERIMENT EXPERIMENTER DECLARATION: I understand the contents of these safety documents. I am aware that any change in the experiment beyond that identified in these safety documents means that work must stop, the Risk Assessment reviewed and permission to resume has been given and countersigned by the Project Supervisor or Head of Laboratory. Name of Student: Signed: Date: Name of Supervisor: Signed: Date: Name of HoL: Signed: Date: *HoL must be identified and sign here having confirmed the safety documents to be satisfactorily completed. Document Cancelled: Date: Name: _________ Risk assessment form ver. 1 8th October 2015 Signature: Safety Document (Risk Assessment) METHOD STATEMENT Title of Experiment / Test:Prepared by:- Date:- A. Purpose of Experiment: B. Equipment Being Used / Circuit Diagram (where appropriate): C. Experimental Procedure: Risk assessment form ver. 1 8th October 2015 Safety Document (Risk Assessment) RISK ASSESSMENT (must address all hazards identified in hazard checklist) Title Of Experiment / Test:Prepared By:- Date:Validated By:- Checked By:- (In addition to this risk assessment, a safety commissioning checklist is attached to this document. This checklist is to be completed before HV supplies can be energised. It is relevant to the ‘Electrical shock from high voltage’ and ‘Fire’ hazards described in the table below. Electric shock from high voltage (max 11kV AC) Persons carrying out testing / those close to equipment Risk assessment form ver. 1 8th October 2015 Equipment is interlocked so supplies are isolated when door to cage is opened All leads leaving from cage have earthed sheath (current measurements taken at earthed end of sample, voltage measurement taken with commercial voltage probe) Earth stick applied to HV output of transformer when entering cage Warning lights and signs are placed on cage Risk rating Control measures applied to eliminate / minimise risk Likelihood Persons or Equipment at Risk Severity Hazard (s) & Possible Consequences 5 Risk Acceptable? Residual risk with control measures applied 1 5 Y Safety Document (Risk Assessment) Electric shock from low voltage (max 230V AC) Persons entering cage / working on test equipment Fire Persons within Ferranti building Toxic and corrosive gasses and burning fumes from thermal decomposition of polymer material. Slips (from loss of water used to wet samples) Risk assessment form ver. 1 8th October 2015 Persons within B20 Persons entering cage LV connections to be disconnected before any work takes place on control equipment Stickers warning of need to disconnect mains supply before opening applied to LV control boxes Control box to be PAT tested before use to confirm adequacy of earthing etc. LV supplies to transformer are exposed but are within interlocked area 4 2 1 Y Smoke detector placed above samples to provide audible notification of any fire (in the event that this is sensitive to fumes, to be replaced by a heat detector) Detector linked into control equipment to isolate HV supplies in the event of operation Fire extinguisher available in laboratory Test equipment not to be left unattended when initially operated to confirm behaviour of samples Heat detectors contained to main building fire alarm system present within B20 laboratory 3 1 3 Y Extract fan within B20 to be switched on before testing commences and to remain on for period of test Necessary precautions are described in COSHH assessment. 2 2 4 Y Careful handling of water to take place with no more than is required to be placed within cage Any liquid spillage to be mopped up immediately 2 2 4 Y Safety Document (Risk Assessment) Trips Persons entering cage Chemical contact (preparation of ammonium chloride test solution) Person making solution Risk Assessment Matrix Likelihood (1-5) x Severity (1-5) = Risk (See attached matrix for guidance) Risk assessment form ver. 1 8th October 2015 Leads to be routed away from walkways where possible Any leads that cannot be routed away from walkways to be covered with rubber matting PPE (gloves, lab coat, respirator and eye glasses) to be worn when making up solution 1 2 2 Y 2 2 4 Y 1 – 5: Low: Tolerable – monitor and manage 6 – 8: Medium: Review, introduce further controls to reduce to as low as reasonably possible 9 – 25: High: Intolerable. Do not commence work, further control measures required Safety Document (Risk Assessment) RECORD OF CHEMICAL USAGE WITHIN EXPERIMENT Are Hazards Resulting From Use Described In Risk Assessment Table Above? Method Of Disposal Chemical Reason For Use Chemical Data Sheet Attached? Ammonium Chloride Used to make up solution of correct conductivity for testing Yes Yes Chemical evaporates during test (very small volumes used in each test) Triton-X100 Used to make up solution of correct conductivity for testing Yes Yes Chemical evaporates during test (very small volumes used in each test) Risk assessment form ver. 1 8th October 2015 Safety Document (Risk Assessment) HAZARD CHECKLIST You should indicate the hazards present in the experiment in the table below. If a hazard is present, control measures should be stated on the risk assessment. Note that this list is not exhaustive. Hazard Type Present Electric Shock From High Voltage (1kV & Over) X Electric Shock From Low Voltage (Under 1kV) X Tripping Hazards X Slipping Hazards X Fire X Not Present High Temperatures X Low Temperatures X High Pressure X Low Pressure X Chemical Spillage X Chemical Contact (Ingestion / Eye & Skin Contact) X High Noise Levels X Working At Height X Head Height Hazards X Production Of Dust & Fumes X Manual Handling X Production/Use Of Radiation X Use Of Asphyxiating Gases X Any Other Hazards X Risk assessment form ver. 1 8th October 2015 Safety Document (Risk Assessment) RISK ASSESSMENT SEVERITY MATRIX SEVERITY VALUE = Potential consequence of an incident/injury given current level of controls. 5 4 3 2 1 Very High:- Death / Permanent incapacity / Widespread loss High:- Major Injury (Reportable Category) / Severe Incapacity / Serious Loss Moderate - Injury / Illness of 3 days or more absence (reportable category) / Moderate loss Slight: - Minor injury / Illness – Immediate 1st Aid only / slight loss Negligible No injury or trivial injury / illness / loss LIKELIHOOD = what is the potential of an incident or injury occurring given the current level of controls. 5 4 3 2 1 Almost certain to occur Likely to occur Quite possible to occur Not likely to occur Almost certain not to occur The multiple of Likelihood with Severity is the risk classification value. Severity 1 2 3 4 5 1 Likelihood 2 3 4 5 Risk Classification Value 1–5: Low: Tolerable – monitor and manage 6–8: Medium: Review, introduce further controls to reduce to as low as reasonably possible 9–25: High: Intolerable. Do not commence work, further control measures required Risk assessment form ver. 1 8th October 2015