* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ELECTRICAL MACHINES LABORATORY "................................................................"
Ground (electricity) wikipedia , lookup
Buck converter wikipedia , lookup
Electrical substation wikipedia , lookup
Power inverter wikipedia , lookup
Electric power system wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Utility frequency wikipedia , lookup
Fault tolerance wikipedia , lookup
Pulse-width modulation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Earthing system wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Distribution management system wikipedia , lookup
Power engineering wikipedia , lookup
Voltage optimisation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Electric motor wikipedia , lookup
Electric machine wikipedia , lookup
Alternating current wikipedia , lookup
Rectiverter wikipedia , lookup
Mains electricity wikipedia , lookup
Electrification wikipedia , lookup
Three-phase electric power wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Stepper motor wikipedia , lookup
"Technical Information" ADVANCED ELECTRICAL MACHINES LABORATORY (4EMAD) * Center: "................................................................" * Country: "................................................................" * Date: "................................................................" * Issue: "................................................................" Quality Certificates: Worlddidac Member ISO 9000: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) Certificates ISO 14000 and ECO-Management and Audit Scheme (environmental management) Worlddidac Quality Charter Certificate (Worlddidac Member) Advanced Electrical Machines Laboratory (4EMAD) Index - Classroom and Laboratory Lay Out (Example). - List of modules and teaching units included plus summarised catalogues (included in priority 1 + 2 + 3). Ref.:4EMAD-pre(01/11) Classroom and Laboratory Lay Out ADVANCED ELECTRICAL MACHINES LABORATORY (Example of Priority 1) (4EMAD) 32 cm 1,4 cm Unit EGGMG24 TECNEL INT Unit ROOM 3 1,6 cm 1,5 cm Web-cam Computer for each Teaching Unit Teacher and Student Desk with computers Table for Teaching Unit INT SERIN/CC Unit OTHER TEACHING UNITS WITH COMPUTER CONTROL LIMEL Unit OTHER TEACHING AND NON TEACHING UNITS 25 cm Unit Teaching Unit INT Electronic Interface 90x40 Cupboard 150x80 cm 48x35 cm EDIBON ESN SCADA-NET 90x60 cm 80x30 Table office Shelves Table E: 1:100 9 cm Unit EEA Unit ESAM 90x60 90x60 Unit TEACHER DESK Unit ESAE EDIBON ESN SCADA-NET STOCK EMT-KIT Unit EXPANSIONS SPACE ELECTRONIC BLACKBOARD 90x60 PROJECTOR Unit COMPUTER CONTROLLED UNITS 150x80 150x80 150x80 90x40 90x40 90x40 ROOM 2 MAIN ELECTRICAL CABINET 90x60 EMERGENCY DOOR ROOM 1 MAIN WATER CABINET 90x60 2,7 cm 90x40 150x80 06x051 MAIN AIR PANEL 90x60 90x40 TOILET 100x40 EMT-S OTHER TEACHING UNITS WITH COMPUTER CONTROL SERIN/CA LOCAL NET WITH SCADA-NET SYSTEM 90x40 SERVICES MANAGER ROOM 90x60 TOILET INT 150x80 Unit SEMINARY INT UCP STUDENT TOILET STAND ALONG AND DANGEROUS UNITS OTHER TEACHING AND NON TEACHING UNITS 90x40 3,3 cm Advanced Electrical Machines Laboratory (4EMAD) List of modules and teaching units included plus Summarised Catalogues Priority 1 0400. Electricity 0480: Electrical MachinesBasic Module 0481: Electrical Machines Medium Module 0482: Electrical Machines Advanced Module 0483: Electrical Machines "Disassembly" Module 0490: Cut Away Motors Basic Module 0491: Cut Away Motors MediuM Module 0492: Cut Away Motors Advanced Module 0400/ESN: EDIBON Scada-Net for Electricity Units Ref.:4EMAD-pre(01/11) issue:01/11 ELECTRICAL MACHINES.BASIC MODULE Ref: 0480 ITEM 1 / 2 REFERENCE DESCRIPTION QTY. 1 EME ELECTRICAL MACHINES EQUIPMENT 1 2 RCL3R RESISTIVE,INDUCTIVE AND CAPACITIVE LOADS MODULE 1 3 EMT5 (1) DC SHUNT-SERIES-COMPOUND MOTOR 1 4 EMT7 (1) THREE-PHASE MOTOR SQUIRREL CAGE 1 5 EMT11 (1) SINGLE-PHASE MOTOR OF CONDENSER 1 6 TECNEL/T TACHODYNAMO 60 V,1000 R.P.M 1 7 FRE-FE BRAKING SYSTEM (ELECTRONIC BRAKE) 1 8 EMT5/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DC SHUNT-SERIES-COMPOUND MOTOR 1 9 EMT7/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THREE-PHASE MOTOR SQUIRREL CAGE 1 10 EMT11/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF SINGLE-PHASE MOTOR OF CONDENSER 1 11 INS/SOF CLASSROOM MANAGEMENT SOFTWARE PACKAGE (TEACHER'S SOFTWARE) 1 12 MUAD 1 EPIB DAB MUAD/SOF ELECTRIC POWER DATA ACQUISITION SYSTEM,INCLUDED: ELECTRIC POWER INTERFACE BOX DATA ACQUISITION BOARD DATA ACQUISITION SOFTWARE 1 1 1 13 EAL NETWORK ANALYZER UNIT 1 14 0480PARTS COMPONENTS AND SPARE PARTS 1 15 0480PA COMPLEMENTARY ITEM 1 16 0480IYPM INSTALLATION AND STARTING UP 1 17 0480CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 18 0480TD TEACHING TECHNIQUES "KNOW-HOW" 1 19 0480MANU DOCUMENTATION AND MANUALS 1 Ref: 0480 2 / 2 * Each Software Package contains the following parts: Theory, Exercises, Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 20 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation. - Installation of all units supplied. - Starting up for all units. - Training about the exercises to be done any unit. - Teacher training related with the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit . . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. Calibration manual. See Catalogues in next pages 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: Laboratory structure 1 Common Electrical Machines Base Units: EME/M. Electrical Machines Unit (Intermediate option) (Advanced option) (Basic option) 6 Transformers: 2 Measurement Units Other Network Analyzers: -EALD. With Computer Data Acquisition + Oscilloscope (PC). -EALDG.With Computer Data Acquisition + Oscilloscope (PC)+ Oscilloscope Display. Digital Multimeter EAL. Network Analyzer Unit ETT. Three and Single Phase Transformers Unit 11 MUAD. Power Data Acquisition System -EAM-VA. Analog Measurement Unit -MUAD. Power Data Acquisition System Teaching Technique used 3 Loads: RCL3R. Resistive, Inductive and Capacitive Loads Module EME/B. Electrical Machines Unit 7 DC Motor Speed Control - VVCC/M. DC Motor Speed Controller VVCC. DC Motors Speed Controller Electric Power Interface Box (EPIB) Individual elements: -IND. Inductance. or -CON. Box of condensers. -REV. Variable resistance. -REF. Fixed resistance. Individual elements: -AUTR. Variable Autotransformer. -TRANS. Single-phase transformer. or -TRANS/3.Three-phase transformer. or Data Acquisition Board (DAB) with no other elements 8 AC Motor Speed Control Data Acquisition Software(MUAD/SOF) VVCA. AC Motors Speed Controller or 4 Motors: 12 CAI. Teaching Technique used (intermediate option) with no other elements 9 PLC PLC-PI. PLC Module for the Control of Industrial Processes Software - VVCA/M. AC Motor Speed Controller Individual elements: - VVCA/B. AC motors speed controller, Computer Aided Instruction Software System INS/SOF. Instructor (intermediate option) Individual elements: - VVCC/B. DC motors speed controller, Individual elements: or - EDIBON FP-X-CPU. PLC, + with no other elements. 5 Brakes: FRE-FE. Electronic Brake Other brakes: -DI-FRE. Pendular Dynamo Brake. -FREND. Dynamo Brake. or -FRENP. Magnetic Powder Brake. -FREPR. Prony Brake. -FRECP. Eddy Current Brake EMT../SOF. 10 Tachogenerator Student/Motor Software TECNEL/T. Tachogenerator or - TECNEL/TM. Hand Tachometer Complete configuration Main units: 1 Common Electrical Machines Base Units. 2 Measurement Units. 3 Loads. 4 Motors. 5 Brakes. 11 12 Complementary possibilities: MUAD. Power Data Acquisition System. CAI. Computer Aided Instruction Software System. * MINIMUM CONFIGURATION: 1 + 2 Complementary elements: 6 Transformers. 7 DC Motor Speed Control. 8 AC Motor Speed Control. 9 PLC (Programmable Logic Contoller). 10 Tachogenerator. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 57 www.edibon.com 4.- Electricity EME. Electrical Machines Unit 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) (continuation) Common Electrical Machines Base Units: EDIBON presents three alternatives with increasing complexity and practical possibilities. - EME. Electrical Machines Unit. It is a compact unit including the main electrical functions. It is EDIBON’s most advanced option. - EME/M. Electrical Machines Unit (intermediate option). Students can get a good grasp on the subject. - EME/B. Electrical Machines Unit (basic option). It includes the most basic functions. EME. Electrical Machines Unit (advanced option) SPECIFICATIONS SUMMARY The Electrical Machines Unit (EME) is a compact and robust box for the study of the main electrical functions. In its front side, you find standard electrical functions, divided in sections, for a better visualization of the different applications. In EME, you have all the main panels you need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the components are located within a compact box. Metallic box. 4.- Electricity Diagram in the front panel. Different modules included in the EME unit: -Connection terminals module: Connection terminals of three-phase: R, S and T and supply neutral with the corresponding signaling lamps which indicate the voltage. There are 4 terminals in each phase. Signaling lamp which will light up when the threephase sequence in correct. This module also has a signaling lamp and fuse, corresponding to the internal supply of the unit. -Operation module: 3 Running switches. 3 Stop switches. 3 Three-pole contactors, power A, B and C, with control circuit in alternating current. Each contactor has 2 auxiliary terminals (NC) and 3 auxiliary terminals (NO). 3 Lamps that will light when the contactors are started. 2 Timing realys. Indicating lamps. -Protection module: Thermal Magnetic Circuit Breaker. Thermal relay. 3 Power contacts. 2 auxiliary contacts (NO and NC). Signaling lamp. -Synchronizing and rectification module: 3 lamps, as well as the inlet terminals for the threephases with signaling for indicating its correct sequence. One phase bridge rectifier, with 2 fuses with their corresponding fusion lamps. -Contactors module: 3 Power takes, and the selected position closes the corresponding contact in the three phases. -Possibility of assemblies of control circuits with delay. * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 450 x 470 mm. approx. Weight: 50 Kg. approx. More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf Page 58 PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/2/3/4/5/15) 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristic curve. 5.- Dynamo characteristic regulation curve. 6.- Speed variation, inversion and stop of D.C. motor with independent excitation. 7.- Speed-armature current characteristic curves in a D.C. motor with shunt or independent excitation. 8.- Torque-current characteristic curve in a D.C. motor with shunt or independent excitation. 9.- Torque-speed characteristic curve in a D.C. motor with shunt or independent excitation. 10.- Speed-excitation current characteristic curves in a D.C. motor with independent or shunt excitation. Operation in constant power. 11.- Speed control at constant torque. 12.- Series D.C. motor: starting, speed variation, inversion and braking. 13.- Speed-intensity characteristic curve in a D.C. motor with series excitation. 14.- Torque-current characteristic curve in a D.C. motor with series excitation. 15.- The D.C. motor with series excitation as universal motor. The Synchronous Machine (with motor EMT 6) 16.- Starting, voltage and frequency regulation in a three-phase alternator. 17.- Net coupling of a three-phase alternator. 18.- Characteristic curve of an alternator without load. 19.- Characteristic curve of an alternator in short circuit. 20.- Characteristic curve of an alternator with load. 21.- Synchronous motor starting. The Asynchronous Machine (with motors EMT 7/ 8/ 9/ 10/ 11/ 16/ 17). 22.- Morley diagrams. 23.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 24.- Test without load of an asynchronous motor with rotor in short circuit. 25.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 26.- Starting of a three-phase asynchronous motor with the wound rotor. 27.- Test without load of a three-phase asynchronous motor with the wound rotor. 28.- Test with load of a three-phase asynchronous motor with wound rotor. 29.- Starting and turn sense inversion of a single-phase motor with capacitor. 30.- Test without load of a single-phase asynchronous motor. 31.- Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.- The Universal motor with D.C. supply. 33.- Speed-current characteristic of an Universal motor with D.C. supply. 34.- Torque-intensity characteristic in the D.C. Universal motor. 35.- The universal motor eith A.C. supply. The Repulsion motor (with motor EMT 14) 36.- Starting and inversion of a single-phase repulsion motor. 37.- Test of a single-phase repulsion motor without load. 38.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor (with motor EMT 18) 39.- Brushless motor starting. 40.- Speed control and change of the turn sense. The Dahlander motor (with motor EMT 9) 41.- Dahlander motor starting. 42.- Different working speeds. 43.- Changing the different speeds of Dahlander motor while working. The Stepper motor (with motor EMT 19) 44.- Stepper motor starting. 45.- Steps control. 46.- Rotation sense change. The Reluctance motor ( with motor EMT21) 47.- Star connection of the reluctance motor. 48.- Delta connection of the reluctance motor. 49.- Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) Common Electrical Machines Base Units: (continuation) EME/M. Electrical Machines Unit (intermediate option) More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristics curve. 5.- Characteristic regulation curve of a dynamo. 6.- Speed control at constant torque. 7.- Series D.C. motor: starting, speed variation, inversion and braking. The Synchronous Machine: 8.- Starting, voltage and frequency regulation in a three-phase alternator. 9.- Characteristic curve of an alternator without load. 10.- Characteristic curve of an alternator in short circuit. 11.- Characteristic curve of an alternator with load. 12.- Synchronous motor starting. The Asynchronous Machine: 13.- Morley diagrams. 14.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 15.- Test without load of an asynchronous motor with rotor in short circuit. 16.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 17.- Starting and turn sense inversion of a single-phase motor with capacitor. 18.- Test without load of a single-phase motor. 19.- Test in load of the single-phase motor. The Universal motor: 20.- The universal motor with D.C. supply. 21.- Speed-current characteristic of an Universal motor with D.C. supply. 22.- Torque-intensity characteristic in the D.C. Universal motor. 23.- The Universal motor eith A.C. supply. The Repulsion motor: 24.- Starting and inversion of a single-phase repulsion motor. 25.- Test of a single-phase repulsion motor without load. 26.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor: 27.- Brushless motor starting. 28.- Speed control and change of the turn sense. The Dahlander motor: 29.- Dahlander motor starting. 30.- Different working speeds. The Reluctance motor: 31.- Star connection of the reluctance motor. 32.- Delta connection of the reluctance motor. 33.- Revolution sense and inversion of rotation. EME/B. Electrical Machines Unit (basic option) SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. DC supply 200 V dc with fuses. Connection Key. Emergency stop push button. Two push buttons (1NO + 1NC). * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 300 x 180 x 120 mm. approx. Weight: 5 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 59 PRACTICAL POSSIBILITIES The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- Dynamos with series and shunt excitation. 3.- Speed control at constant torque. 4.- Series D.C. Motor: starting, speed variation, inversion and braking. The Asynchronous Machine: 5.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 6.- Test without load of an asynchronous motor with rotor in short circuit. The Universal motor: 7.- The Universal motor with D.C. supply. www.edibon.com 4.- Electricity PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. Two double switches (1 NO + 1 NC in each one) Push Button (1 NC + 1 NO). Three contactors with 2 NO and 1 NC. DC supply 200 V dc with fuses. Connection Key Emergency stop push button. * Minimum recommended measurement units: (see Section “2”) 2 Digital multimeters. Recommended measurement units: (see Section “2”) EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 25 Kg. approx. 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) (continuation) Measurement Units The measurement units let us extract information from the experimental unit (EME), thus allowing further process of the data. We can get values of currents, voltages, resistance, etc. for further analysis. MULT. Digital Multimeter SPECIFICATIONS SUMMARY Digital multimeter. Voltage and current meter. Resistances and capacitors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAL. Network Analyzer Unit 4.- Electricity SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals, for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EALD. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC). SPECIFICATIONS SUMMARY This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ±0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 60 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) Measurement Units (continuation) EALDG. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC) + Oscilloscope Display SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES 4.- Electricity This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Steel box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display and oscilloscope display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAM-VA. Analog Measurement Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit allows to analyze the different voltages and currents involved in a circuit through a simple frontal panel that includes analog measurement instruments. Metallic box. 4 Voltmeters. - A.C. Measuring Instruments with moving iron. - Voltmeter with measuring range from 0 to 500Vac. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Ammeters. - A.C. Measuring Instruments with moving iron. - Ammeter with measuring range of 0 to 5A. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Analog inputs for each meter. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf MUAD. Power Data Acquisiton System. (see page 68) Page 61 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) Loads: RLC3R. Resistive, Inductive and Capacitive Loads Module 3 SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES When you brake an electrical machine, the electrical energy has to be dissipated. Loads provide this function, the dissipation of energy. Depending on the experiment, the dissipating load has to be resistive, inductive or capacitive. EDIBON recommends having the three kinds, if a good understanding on the subject is pursued. Our Resistive, Capacitive and Inductive Loads Module (RCL3R) offers: Single and Three-phase resistances. Single and Three-phase inductances. Single and Three-phase capacitors. Metallic box. Diagram in the front panel. Variable resistive loads: 3 x [ 150 W (500 W) ]. Fixed resistive loads: 3 x [ 150 W (500 W) + 150 W (500 W) ]. Inductive loads: 3 x [ 0, 33, 78, 140, 193, 236 mH ].(230V /2 A) Capacitive loads: 3 x [ 4 x 7 mF ]. (400V) Dimensions: 490 x 450 x 470 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 4.- Electricity Individual Elements IND CON PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY When a simpler and cheaper option is preferred when studying the use of loads in electrical machines, EDIBON gives the choice of acquiring single components. They are offered as single independent components to be mounted by the student. -IND. Inductance: From 33 to 236 mH, or similar. -CON. Box of Condensers: 7µF or similar. -REV. Variable Resistance: 0-150Ù (500W), or similar. -REF. Fixed Resistance : 150Ù (500W), or similar. REV More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf REF 4 Motors EDIBON has a wide range of electric motors. The motors supplied include connectors, couplings, standard motor support, etc. SPECIFICATIONS SUMMARY EMT2 EMT3 EMT1 EMT5 EMT4 EMT6 EMT8 EMT7 EMT9 EMT11 EMT12 EMT10 EMT15 EMT16 EMT14 EMT19 EMT17 EMT20 Available Motors EMT1. D.C. Independent excitation motor-generator. EMT2. D.C. Series excitation motor-generator. EMT3. D.C. Shunt excitation motor-generator. EMT4. D.C. Compound excitation motor-generator. EMT5. D . C . S h u n t - s e r i e s compound excitation motor. EMT6. A . C . S y n c h r o n o u s alternator motor. EMT7. Asynchronous three-phase motor of squirrel cage. EMT8. Asynchronous three-phase motor with wound rotor. EMT9. Dahlander three-phase (two-speeds). EMT10. Asynchronouts three-phase motor of two independent speeds. EMT11. Asynchronous single-phase motor with starting capacitor. EMT12. Universal motor (singlephase). EMT14. Repulsion motor, singlephase with short-circuited brushes. EMT15. D.C. Permanent magnet motor. EMT16. Asynchronous single-phase motor with starting and running capacitor. EMT17. Three-phase motor of squirel c a g e w i t h “ Y ” connection. EMT18. D.C. Brushless motor. EMT19. Stepper motor. EMT20. Asynchronous single-phase motor with split phase. EMT21. Three-phase Reluctance motor. EMT22. Single-phase Shaded Pole motor. PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/ 2/ 3/4/5/15) 1.-Preparation,regulationandinversionin adynamowithindependentexcitation. 2.-Thedynamocharacteristiccurvewithout load. 3.-Dynamos with series and shunt excitation. 4.-Dynamoexternalcharacteristiccurve. 5.-Dynamo characteristic regulation curve. 6.-Speed variation, inversion and stop of D.C. motor with independent excitation. 7.-Speed-armature current characteristic curve in a D.C. motor with shunt or independentexcitation. 8.-Torque-current characteristic curve in a D.C. Motor with shunt or independentexcitation. 9.-Torque-speed characteristic curve in a D.C. Motor with shunt or independent excitation. 10.-Speed-excitation current characteristic curve in a D.C. Motor with independent or shunt excitation. Operation in constantpower. 11.-Speedcontrolatconstanttorque. 12.-Series D.C. Motor: starting, speed variation,inversionandbraking. 13.-Speed-intensity characteristic curve inaD.C.Motorwithseriesexcitation. 14.-Torque-current characteristic curve inaD.C.Motorwithseriesexcitation. 15.-The D.C. Motor with series excitation asuniversalmotor. The Synchronous Machine (with motor EMT6) 16.-Starting, voltage and frequency regulation in a three-phase alternator. 17.-Net coupling of a three-phase alternator. 18.-Characteristic curve of an alternator withoutload. 19.-Characteristic curve of an alternator inshortcircuit. 20.-Characteristic curve of an alternator withload. 21.-Synchronousmotorstarting. The asynchronous Machine (with motors EMT7/8/9/10/11/16/17) 22.-Morleydiagrams. 23.-Starting process of a three-phase asynchronous motor with rotor in shortcircuit. 24.-Test without load of an asynchronous motorwithrotorinshortcircuit. More information in: 25.-Test with load of a three-phase www.edibon.com/products/catalogues/ asynchronous motor with rotor in en/units/electricity/machines/ shortcircuit. LIMEL.pdf Page 62 26.-Starting of a three-phase asynchronous motor with the woundrotor. 27.-Test without load of a three-phase asynchronous motor with the woundrotor. 28.-Test with load of a three-phase asynchronous motor with wound rotor. 29.-Starting and turn sense inversion of a single-phase motor with capacitor. 30.-Test without load of a single-phase motor. 31.-Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.-The universal motor with D.C. Supply. 33.-Speed-current characteristic of an UniversalmotorwithD.C.Supply. 34.-Torque-intensity characteristic in theD.C.Universalmotor. 35.-The universal motor eith A.C. Supply. The repulsion motor (with motor EMT 14) 36.-Starting and inversion of a singlephaserepulsionmotor. 37.-Test of a single-phase repulsion withoutload. 3 8 . -Te s t o f a s i n g l e - p h a s e asynchronous repulsion motor withA.C. The Brushless motor (with motor EMT 18) 39.-Brushlessmotorstarting. 40.-Speed control and change of the turnsense. The Dahlander motor (with motor EMT 9) 41.-Dahlandermotorstarting. 42.-Differentworkingspeeds. 43.-Changing the different speeds of Dahlandermotorwhileworking. TheSteppermotor(withmotorEMT19) 44.-Steppermotorstarting. 45.-Stepscontrol. 46.-Rotationsensechange. The Reluctance motor (with motor EMT21) 47.-Star connection of the reluctance motor. 48.-Delta connection of the reluctance motor. 49.-Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 5 (continuation) Brakes The importance of Brakes comes when we want to adjust the motor speed, measure the torque given, or stop the motor. FRE-FE. Electronic Brake SPECIFICATIONS SUMMARY This unit is based in two elements: 1.- Module -metallic box: Power supply:1 phase, 200-240V. Rated output capacity:0.75 KW. Output frequency range: 0.2 to 400 Hz. Display to visualize voltage (V), Current (A), and Frequency (Hz). Brake resistance included. Torquemeter. R.p.m. Meter. Connectors. 2.- Braking motor mounted on a bench-support. Connection wire between elements “1” and “2”. Electrical supply: 220V a.c. - 110V a.c., single-phase + ground. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf DI-FRE. Pendular Dynamo Brake SPECIFICATIONS SUMMARY 4.- Electricity Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Torque measured with lever and weights, by combining the mechanical torque and electrical torque. Security connectors. Bench-support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREND. Dynamo Brake SPECIFICATIONS SUMMARY Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Connectors. Bench - support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRENP. Magnetic Powder Brake SPECIFICATIONS SUMMARY The unit consists of a magnetic powder brake, a control module an a tachometer for the speed measurement. The control module allows setting the nominal torque of the brake through a potentiometer. It has two terminals to measure a voltage in direct proportion to the current supplied to the brake, therefore, to the exerted torque. The unit has a tachometer connected to its axis. The unit also includes a fuse and a thermal relay to avoid eventual damages. Max. power: 400 W, limited at 220W. Voltage: 24 Vac. Max. torque: 5 Nm. Max. R.P.M.: 3000. It is equipped with temperature probe to stop the braking action. Electrical supply: 220 Vac. - 110 Vac. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREPR. Prony Brake SPECIFICATIONS SUMMARY Prony brake with resistant ribbon. Mechanical braking action and dynamometer. Max. Power: 500 W. Max. Torque: 4Nm. Max. R.P.M.: 3000. Max. Time: 30 seconds. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRECP. Eddy Current Brake SPECIFICATIONS SUMMARY Max. Power: 500 W. Voltage: 120 Vdc. Max. Torque: 3Nm. Max. R.P. M.: 3000. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 63 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) 6 Transformers 4.- Electricity ETT. Three-phase and Single-phase Transformers Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Metallic box. Diagram in the front panel. Single-phase transformer: Nominal power: 500 VA. Transformation ratio: 400 / 230 V. Inlets: 400 V and 230 V (in the primary). Number of secondary coils: 2. Output voltage in the secondary: 115 (each one). Maximum current in the primary: 1.5 A (for each voltage of 400 V). 3 A (for each voltage of 230 V). Three-phase transformer in pillars: Nominal power: 1000 VA. Transformation ratio: 380/3 x 127 V. Inlets: 220 V and 380 V (in the primary). Outlet voltage in the secondary: 3 x 127 V (each phase). Maximum current in the primary: 2 A (for a voltage of 380 V). 2 A (for a voltage of 220 V). Connection modes: Primary: Star, triangle / Secondary: Star, triangle, zigzag, six-phase and triple star. Electrical supply: For Single-phase transformer: 400-230 V / 50 Hz. or 60 Hz. For Three-phase transformer: 380-220 V / 50 Hz. or 60 Hz. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. 1.- Measurement of the transformation Ratio. 2.- Rehearsal of a single-phase transformer in open circuit. 3.- Rehearsal of a single-phase transformer in short circuit. 4.- Rehearsal of a single-phase transformer in load. 5.- Rehearsal of a three-phase transformer in open circuit. 6.- Rehearsal of a three-phase transformer in short circuit. 7.- Autotransformer tests. 8.- Connection modes tests: Start/delta/Zig-Zag/6-phase/triple star. 9.- Transformer ratio variation tests. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TPPT. Three-phase Power Transformer Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The “TPPT” unit is formed by a steel box, which contains a three-phase power transformer. In the front panel of the box are located the terminals for both primary and secondary terminals for different power supply inputs and outputs. In the backside are located the fuses to protect the transformer. Diagram in the front panel. Power: 1000 VA. Module 1: Primary winding It includes a three-phase winding which can be connected externally in either star or triangle, each phase winding has a neutral terminal, a 146V a.c. intermediate terminal and 220V a.c. terminal. Module 2: Secondary winding It includes a three-phase winding which can be connected externally in either star of triangle. Each phase winding has a neutral terminal, a 127V a.c. intermediate terminal and a 220V a.c. terminal. This unit can be used to make 6 different a.c. connection types: -Star (380V). - Triangle (380V). -Triangle (220V). - Triangle (380V). -Star (380V). - Star (220V). -Triangle (220V). - Star (220V). -Star (380V). - Triangle (127V). -Triangle (220V). - Triangle (127V). Electrical supply: 380-220 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EMPTA. Auxiliary Transformer and Protection Module SPECIFICATIONS SUMMARY Metallic Box. Diagram in the front panel. Input and output connectors. Thermal magnetic unit 16 A ., 2 poles. Differential 25 A., 30 mV., 230 V. Reversible auto-transformer 125-220 (1000 VA). Conversion from 127V. 60Hz to 220V. 50Hz. Conversion from 220V. 50Hz to 127V. 60Hz. Differential electrical protection. Thermal magnetic protection. Required services: Input: 220V. 50Hz or 127V. 60Hz. Electrical supply: 220 V a.c. - 127 V a.c. Dimensions: 300 x 120 x 190 mm. approx. Net weight: 3Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: - AUTR. - TRANS. SPECIFICATIONS SUMMARY Variable Auto-transformer. Single-phase transformer. Input and output connectors. Single phase transformer, 400 Vac/230 Vac, 400 VA. Ground connector. - TRANS/3.Three-phase transformer. Input and output connectors. Three phase transformer, 400 Vac/230 Vac, 1000 VA TRANS More information in: www.edibon.com/products/catalogues/en/ TRANS/3 units/electricity/machines/LIMEL.pdf Page 64 PRACTICAL POSSIBILITIES 1.- Conversion from 127V/60Hz to 220V/ 50Hz. 2.- Conversion from 220V/50Hz to 127V/ 60Hz. 3.- Differential electrical protection. 4.- Thermal magnetic protection. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 7 (continuation) DC Motor Speed Control VVCC. DC Motor Speed Controller This unit varies the speed of a DC motor for control applications. It works with any DC motor available. Metallic box. Front panel including: Excitation connection (2 connectors). Rotor connection (2 connectors). Tachodynamo connection (2 connectors). Parameters self adjustment (torque control and speed control): Motor torque regulator. Motor speed regulator. State leds indicators. START/STOP speed controller switch. ON/OFF main switch. Maximum power: 550W. Maximum torque: 2.6 Nm Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 10 Kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a certain frequency. 3.- Starting carrying out by defined ramp. 4.- Braking possibility until a certain speed and recovery. 4.- Electricity SPECIFICATIONS SUMMARY More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCC/M. DC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consists in a variable transformer followed by a rectifier bridge and an anti-ripple capacitor with a resistor to get discharged. Metallic box. Regulated voltage output up to ~320 Vdc. Maximum current output 2 A. Front panel including: Connections: Positive, negative and ground connections. ON/OFF switch. The top side of the unit include a wheel to adjust the DC output voltage up to ~320 Vdc. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES -VVCC/B. DC motors speed controller, with no other elements. Maximum power: 550W. Maximum torque: 2.6 N.m. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 65 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 8 (continuation) (continuation) AC Motor Speed Control VVCA. AC Motor Speed Controller SPECIFICATIONS SUMMARY 4.- Electricity This is a unit for varying the speed of an AC motor for control applications. It works with any AC motor available. This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a direct current motor. It consists basically on a rectifying phase coupled to another inverter phase, with a capacitor in parallel between them. By varying the shooting frequency of the IGBT, we obtain an alternating output at a variable frequency which is applied to the asynchronous motor. Metallic box. Circuit diagram in front panel. It has a control panel in order to introduce the parameters of the motor that is going to be used and the output frequency. In addition, through it, we can carry out several programming. It also has a series of terminals where we connect the digital and analog inputs and the relay and transistor outputs. Maximum power: 750 W. Parameter self adjustment. Analog/digital parameter inlets through panel. Turn inversion while running. Analog parameter visualization. Voltage Input : Frequency set according to external command: up to 50Hz. Reversible operation using +/- signal: 0 to +/-10 V. PID control. Current input: Frequency set according to the analog input current command: up to 50 Hz. Reversible operation: 20 to 4mA. PID control. 5 Digital inputs that can be configured by the user. 1 outlet to alarm relay. 2 transistor internal outlets. Maximum load current: 50 mA. Leak current at OFF: 0.1 mA. Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 600 x 600 x 150 mm. approx. Weight: 30 kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a frequency given by the panel. 3.- Working at a frequency given by an analog input (potentiometer). 4.- Turn inversion. 5.- Display of analog output. 6.- Digital inputs configuration. 7.- Outputs from alarm to relay. 8.- Outputs from alarm to transistor. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCA/M. AC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consist in a simple AC motor speed controller. Metallic box. Output: 3 PH, 3.0 KVA, 220 V, 1-50 Hz., 8.0 A. Overload current thermal protection. ON/OFF switch. It has two blocks in the front panel: Speed control: Start/Stop switch. Speed control potenciometer. Connections to motor: Three-phase connection to AC motor. Ground connection. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elemenents: SPECIFICATIONS SUMMARY -VVCA/B. AC motors speed controller, with no other elements. Frequency from 0 to 60Hz. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 66 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 9 (continuation) PLC (Programmable Logic Controller) The Programmable Logic Controller is a device designed for real time control of sequential processes in an industrial environment. In this case, EDIBON has developed this PLC module for controlling the Electrical Machines Unit “EME”. PLC-PI. PLC Module for the Control of Industrial Processes PLC-PI + PLC-SOF This module has been designed for the Control of Industrial Processes. The application has been developed to be used with any individual electric machine. PLC-PI. Unit: Metallic box. Circuit diagram in the front panel. Front panel: Digital inputs(X) and Digital outputs (Y) block: 16 Digital inputs. 14 Digital outputs. Analog inputs block: 16 Analog inputs. Analog outputs block: 4 Analog outputs. Touch screen. Back panel: Power supply connector. 2 A Fuse. RS-232 connector to PC. Inside: Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable. Panasonic PLC: High-speed scan of 0.32 msec. for a basic instruction. Program capacity of 32 Ksteps, with a sufficient comment area. Equipped with a USB communication port. High-speed counter. Multi-point PID control. Digital inputs/outputs and analog inputs/outputs Panasonic modules. RS232 Communication wire, to computer (PC). PLC-SOF. PLC Control Software: The software package is always included with the PLC-PI unit, since it is the necessary application to program the PLC-PI from the computer. Electrical supply single-phase, 220 V. - 110 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf PRACTICAL POSSIBILITIES 1.- Control of the particular unit process through the control interface box without the PC. 2.- PID control. 3.- Visualization of all the sensors values used in the particular unit process. 4.- Calibration of all sensors included in the particular unit process. 5.- Hand on of all the actuators involved in the particular unit process. 6.- Realization of different experiments, in automatic way, without having in front the particular unit. (This experiment can be decided previously). 7.- Simulation of outside actions, when there are not any hardware element present. 8.- PLC hardware general use and manipulation. 9.- PLC process application for the particular unit. 10.- PLC structure. 11.- P L C i n p u t s a n d o u t p u t s configuration. 12.- PLC configuration possibilities. 13.- PLC program languages. 14.- PLC different programming standard languages (ladder diagram (LD), structures text (ST), instructions list (IL), sequential function chart (SFC), function diagram (FBD). 15.- New configuration and development of new process. 16.- Hand on an established process. 17.- Visualization of results and comparisons with the particular unit process. 18.- Possibility if creating new process in relation with the particular unit process. 19.- PLC Programming exercises. 20.- O w n P L C a p p l i c a t i o n s i n accordance with teacher and student requirements. EDIBON FP-X/CPU. PLC, with no other elements SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Inputs: 8. Input Commons: 1. Output: 6. Output commons: 4. Execution time: 0.32µs. Data memory: 12,285. Bit memory: 4096. High Speed Counter. Interrupt: 8 input interrupt X0 to X7. Constant time interrupt (0.5ms to 30sec). Interrupt subroutine jump time: 10 micro sec . PID: PID algorithm (with auto tuning). I-PD algorithm (with auto tuning).10ms cycle to 100s cycle. Dimension (w, h, d): 60 x 90 x 79mm. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 10 Tachogenerator TECNEL/T. Tachogenerator SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The Tachogenerator, as a speed transducer, provides a means of converting the rotational speed into an analog voltage signal. Thus, it is mainly used for measuring the motor speed. The TECNEL/T is an automatic unit, that could be permanently connected to the main rotor. Output voltage gradient: 30 +/- 3% V /1000 r.p.m. Electrical supply: continuous d.c. output 0-100 V. Dimensions: 200 x 150 x 50 mm. approx. Weight: 1Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TECNEL/TM. Hand Tachometer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This is a hand optical tachogenerator. It cannot be attached to the motor, what implies that the measurements have to be taken manually. Page 67 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: (continuation) Data Acquisition 11 MUAD. Power Data Acquisition System 3 4 “n” EME unit Electric power interface box (EPIB) Cable to computer (DAB) Connections points Data acquisition board 2 MUAD is the perfect link between the EME unit and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope. We easily connect the Electric Power Interface Box (EPIB) to the EME unit with the supplied cables (there are several connection points placed for it). The EPIB is connected to the PC through the Data Acquisition Board (DAB), and by using the Data Acquisition with Virtual Instrumentation Software, the student can get results from the undertaken experiment/practice, see them on the screen and work with them. Data acquisition software (MUAD/SOF) Cables to interface 1 Student post This MUAD System includes EPIB + DAB + MUAD/SOF: 4.- Electricity 1)Hardware : 1.1) EPIB. Electric power interface box ( dimensions: 300 x 120 x 180 mm. approx.): Interface that carries out the conditioning of the diverse signals that can be acquired in a process, for their later treatment and visualisation. Front panel separated in two: left-hand part for VOLTAGE sensors, and right-hand part for CURRENT Sensors. - 8 analog input channels. - Sampling range: 250 KSPS (Kilo samples per second). - 4 Tension sensors AC/DC, 400V. - 4 Current sensors. 1.2) DAB. Data acquisition board : PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI. Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KSPS (Kilo samples per second). Analog output: Number of channels=2. Resolution=16 bits, 1 in 65536. Digital Input/Output: Number channels=24inputs/outputs. Timing: Counter/timers=2. EPIB DAB 2) MUAD/SOF. Data acquisition software : Data Acquisition Software with Graphic Representation: Amicable graphical frame. Compatible with actual Windows operating systems. Configurable software allowing the representation of temporal evolution of different signals. Visualization of circuit tensions on the computer screen. Sampling rate up to 250 KSPS (Kilo samples per second) guaranteed. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf 12 Software CAI. Computer Aided Instruction Software System With no physical connection between motor and computer, this complete package consists on an Instructor Software (INS/SOF) totally integrated with the Student Software (EMT../SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. These, on the other hand, get a virtual instructor who helps them to deal with all the information on the subject of study. + Motor Instructor Software MUAD/SOF Student/Motor Software With the INS/SOF. Classroom Management Software Package (Instructor Software), the Teacher has a whole range of options, among them: - Organize Students by Classes and Groups. - Create easily new entries or delete them. - Create data bases with student information. - Analyze results and make statistical comparisons. - Print reports. - Develop own examinations. - Detect student’s progress and difficulties. ...and many other facilities. The Instructor Software is the same for all the motors, and working in network configuration, allows controlling all the students in the classroom. EMT../SOF. Computer Aided Instruction Software Packages (Student Software) Explains how to use the motor and run the experiments and what to do at any moment. Each motor has its own Student Software package. - The options are presented by pull-down menus and pop-up windows. - Each Software Package contains: Theory: that gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done, alongside the motors, showing how to complete the circuits and get the right information from them. Exams: set of questions presented to test the knowledge obtained. Available Student Software Packages: -EMT1/SOF. -EMT2/SOF. -EMT3/SOF. -EMT4/SOF. -EMT5/SOF. -EMT6 /SOF. -EMT7 /SOF. -EMT8 /SOF. -EMT9 /SOF. -EMT10/SOF. -EMT11/SOF. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. Asynchronous three-phase motor with wound rotor. Dahlander three-phase (two-speeds). Asynchronous three-phase motor with two independent speeds. Asynchronous single-phase motor with starting capacitor. -EMT12/SOF. -EMT14/SOF. -EMT15/SOF. -EMT16/SOF. -EMT17/SOF. -EMT18/SOF. -EMT19/SOF. -EMT20/SOF. -EMT21/SOF. -EMT22/SOF. Universal motor (single-phase). Repulsion motor, single-phase with short-circuited brushes. DC Permanent magnet motor. Asynchronous single-phase motor with starting and running capacitor. Three-phase motor of squirrel cage with “Y” connection. DC Brushless motor. Stepper motor. Asynchronous single-phase motor with split phase. Three-phase Reluctance motor. Single-phase Shaded Pole motor. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 68 issue:01/11 ELECTRICAL MACHINES.MEDIUM MODULE Ref: 0481 ITEM 1 / 3 REFERENCE DESCRIPTION QTY. 1 VVCC DIDACTIC DC SPEED CONTROLLER 1 2 VVCC/CAL COMPUTER AIDED LEARNING SOFTWARE FOR DIDACTIC DC SPEED CONTROLLER (RESULTS CALCULATION AND ANALYSIS) 1 3 VVCA AC SPEED CONTROLLER 1 4 VVCA/CAL COMPUTER AIDED LEARNING SOFTWARE FOR AC SPEED CONTROLLER (RESULTS CALCULATION AND ANALYSIS) 1 5 ETT THREE-PHASE AND SINGLE-PHASE TRANSFORMERS EQUIPMENT 1 6 ETT/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THREE-PHASE AND SINGLE-PHASE TRANSFORMERS 1 7 ETT/CAL COMPUTER AIDED LEARNING SOFTWARE FOR AUXILIARY TRANSFORMER AND PROTECTION MODULE (RESULTS CALCULATION AND ANALYSIS) 1 8 EMPTA AUXILIARY TRANSFORMER AND PROTECTION MODULE 1 9 FREND DYNAMO BRAKE 300W 1 10 EMT1 (1) DC INDEPENDENT EXCITATION MOTOR 1 11 EMT2 (1) DC SERIES EXCITATION MOTORS 1 12 EMT3 (1) DC SHUNT EXCITATION MOTOR 1 13 EMT4 (1) DC COMPOUND EXCITATION MOTOR 1 14 EMT6 (1) SYNCHRONOUS ALTERNATOR MOTOR 1 15 EMT7B (1) THREE-PHASE MOTOR OF SQUIRREL CAGE (DOUBLE) 1 16 EMT8 (1) THREE-PHASE MOTOR 1 17 EMT9 (1) DAHLANDER THREE-PHASE 1500/3000 1 18 EMT9B (1) DAHLANDER THREE-PHASE (THREE SPEEDS) 1 19 EMT10 (1) 2 VELOCITIES THREE-PHASE MOTOR 1 20 EMT12 (1) UNIVERSAL SINGLE-PHASE MOTOR 1 21 EMT14 (1) REPULSION MOTOR 1 22 EMT15 (1) D.C. PERMANENT MAGNETS MOTOR 1 23 EMT16 (1) SINGLE-PHASE MOTOR WITH STARTING CONDENSER & WORKING 1 24 EMT17 (1) THREE-PHASE MOTOR OF SQUIRREL CAGE WITH "Y" CONNECTION 1 25 EMT19 (1) STEPPING MOTOR 1 26 EMT1/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DC INDEPENDENT EXCITATION MOTOR 1 27 EMT2/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DC SERIES EXCITATION MOTORS 1 28 EMT3/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DC SHUNT EXCITATION MOTOR 1 29 EMT4/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DC COMPOUND EXCITATION MOTOR 1 WOUND ROTOR Ref: 0481 ITEM 2 / 3 REFERENCE DESCRIPTION QTY. 30 EMT6/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF COMPUTER AIDED INSTRUCTION SOFTWARE OF SYNCHRONOUS ALTERNATOR MOTOR 1 31 EMT7B/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE FOR THREE-PHASE MOTOR OF SQUIRREL CAGE (DOUBLE) 1 32 EMT8/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THREE-PHASE MOTOR WOUND ROTOR 1 33 EMT9/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DAHLANDER THREE-PHASE TWO SPEED 1 34 EMT9B/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE FOR DAHLANDER THREE-PHASE (THREE SPEEDS) 1 35 EMT10/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF 2 VELOCITIES THREE-PHASE MOTOR 1 36 EMT12/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF UNIVERSAL SINGLE-PHASE MOTOR 1 37 EMT14/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF REPULSION MOTOR 1 38 EMT15/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF D.C. PERMANENT MAGNETS MOTOR 1 39 EMT16/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF SINGLE-PHASE MOTOR WITH STARTING CONDENSER & WORKING 1 40 EMT17/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THREE-PHASE MOTOR OF SQUIRREL CAGE WITH "Y" CONNECTION 1 41 EMT19/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF STEPPING MOTOR 1 42 ESAM FAULTS SIMULATIONS TRAINER IN ELECTRICAL MOTORS 1 43 ESAM/SOF * COMPUTER AIDED INSTRUCTION SOFTWARE OF FAULTS SIMULATIONS TRAINER IN ELECTRICAL MOTORS 1 44 ESAE ELECTRICAL FAULTS SIMULATION TRAINER 1 45 ESAE/SOF * COMPUTER AIDED INSTRUCTION SOFTWARE OF ELECTRICAL FAULTS SIMULATION TRAINER 1 46 EEA ALTERNATORS STUDY UNIT 1 47 EEA/SOF * COMPUTER AIDED INSTRUCTION SOFTWARE OF ALTERNATORS STUDY UNIT 1 48 EGMG24 MOTOR-GENERATOR GROUP, THREE-PHASE 24VAC, NO EXCITATION REQUIRED (PERMANENT MAGNETS) 1 49 EGMG24/SOF * COMPUTER AIDED INSTRUCTION SOFTWARE OF MOTOR-GENERATOR GROUP, THREE-PHASE 24VAC, NO EXCITATION REQUIRED (PERMANENT MAGNETS) 1 50 INS/SOF CLASSROOM MANAGEMENT SOFTWARE PACKAGE (TEACHER'S SOFTWARE) 1 51 0481PARTS COMPONENTS AND SPARE PARTS 1 52 0481PA COMPLEMENTARY ITEM 1 53 0481IYPM INSTALLATION AND STARTING UP 1 54 0481CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 55 0481TD TEACHING TECHNIQUES "KNOW-HOW" 1 Ref: 0481 ITEM 56 3 / 3 REFERENCE 0481MANU DESCRIPTION DOCUMENTATION AND MANUALS * Each Software Package contains the following parts: Theory, Exercises, Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 20 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation. - Installation of all units supplied. - Starting up for all units. - Training about the exercises to be done any unit. - Teacher training related with the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit . . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. Calibration manual. See Catalogues in next pages QTY. 1 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: Laboratory structure 1 Common Electrical Machines Base Units: EME/M. Electrical Machines Unit (Intermediate option) (Advanced option) (Basic option) 6 Transformers: 2 Measurement Units Other Network Analyzers: -EALD. With Computer Data Acquisition + Oscilloscope (PC). -EALDG.With Computer Data Acquisition + Oscilloscope (PC)+ Oscilloscope Display. Digital Multimeter EAL. Network Analyzer Unit ETT. Three and Single Phase Transformers Unit 11 MUAD. Power Data Acquisition System -EAM-VA. Analog Measurement Unit -MUAD. Power Data Acquisition System Teaching Technique used 3 Loads: RCL3R. Resistive, Inductive and Capacitive Loads Module EME/B. Electrical Machines Unit 7 DC Motor Speed Control - VVCC/M. DC Motor Speed Controller VVCC. DC Motors Speed Controller Electric Power Interface Box (EPIB) Individual elements: -IND. Inductance. or -CON. Box of condensers. -REV. Variable resistance. -REF. Fixed resistance. Individual elements: -AUTR. Variable Autotransformer. -TRANS. Single-phase transformer. or -TRANS/3.Three-phase transformer. or Data Acquisition Board (DAB) with no other elements 8 AC Motor Speed Control Data Acquisition Software(MUAD/SOF) VVCA. AC Motors Speed Controller or 4 Motors: 12 CAI. Teaching Technique used (intermediate option) with no other elements 9 PLC PLC-PI. PLC Module for the Control of Industrial Processes Software - VVCA/M. AC Motor Speed Controller Individual elements: - VVCA/B. AC motors speed controller, Computer Aided Instruction Software System INS/SOF. Instructor (intermediate option) Individual elements: - VVCC/B. DC motors speed controller, Individual elements: or - EDIBON FP-X-CPU. PLC, + with no other elements. 5 Brakes: FRE-FE. Electronic Brake Other brakes: -DI-FRE. Pendular Dynamo Brake. -FREND. Dynamo Brake. or -FRENP. Magnetic Powder Brake. -FREPR. Prony Brake. -FRECP. Eddy Current Brake EMT../SOF. 10 Tachogenerator Student/Motor Software TECNEL/T. Tachogenerator or - TECNEL/TM. Hand Tachometer Complete configuration Main units: 1 Common Electrical Machines Base Units. 2 Measurement Units. 3 Loads. 4 Motors. 5 Brakes. 11 12 Complementary possibilities: MUAD. Power Data Acquisition System. CAI. Computer Aided Instruction Software System. * MINIMUM CONFIGURATION: 1 + 2 Complementary elements: 6 Transformers. 7 DC Motor Speed Control. 8 AC Motor Speed Control. 9 PLC (Programmable Logic Contoller). 10 Tachogenerator. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 57 www.edibon.com 4.- Electricity EME. Electrical Machines Unit 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) (continuation) Common Electrical Machines Base Units: EDIBON presents three alternatives with increasing complexity and practical possibilities. - EME. Electrical Machines Unit. It is a compact unit including the main electrical functions. It is EDIBON’s most advanced option. - EME/M. Electrical Machines Unit (intermediate option). Students can get a good grasp on the subject. - EME/B. Electrical Machines Unit (basic option). It includes the most basic functions. EME. Electrical Machines Unit (advanced option) SPECIFICATIONS SUMMARY The Electrical Machines Unit (EME) is a compact and robust box for the study of the main electrical functions. In its front side, you find standard electrical functions, divided in sections, for a better visualization of the different applications. In EME, you have all the main panels you need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the components are located within a compact box. Metallic box. 4.- Electricity Diagram in the front panel. Different modules included in the EME unit: -Connection terminals module: Connection terminals of three-phase: R, S and T and supply neutral with the corresponding signaling lamps which indicate the voltage. There are 4 terminals in each phase. Signaling lamp which will light up when the threephase sequence in correct. This module also has a signaling lamp and fuse, corresponding to the internal supply of the unit. -Operation module: 3 Running switches. 3 Stop switches. 3 Three-pole contactors, power A, B and C, with control circuit in alternating current. Each contactor has 2 auxiliary terminals (NC) and 3 auxiliary terminals (NO). 3 Lamps that will light when the contactors are started. 2 Timing realys. Indicating lamps. -Protection module: Thermal Magnetic Circuit Breaker. Thermal relay. 3 Power contacts. 2 auxiliary contacts (NO and NC). Signaling lamp. -Synchronizing and rectification module: 3 lamps, as well as the inlet terminals for the threephases with signaling for indicating its correct sequence. One phase bridge rectifier, with 2 fuses with their corresponding fusion lamps. -Contactors module: 3 Power takes, and the selected position closes the corresponding contact in the three phases. -Possibility of assemblies of control circuits with delay. * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 450 x 470 mm. approx. Weight: 50 Kg. approx. More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf Page 58 PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/2/3/4/5/15) 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristic curve. 5.- Dynamo characteristic regulation curve. 6.- Speed variation, inversion and stop of D.C. motor with independent excitation. 7.- Speed-armature current characteristic curves in a D.C. motor with shunt or independent excitation. 8.- Torque-current characteristic curve in a D.C. motor with shunt or independent excitation. 9.- Torque-speed characteristic curve in a D.C. motor with shunt or independent excitation. 10.- Speed-excitation current characteristic curves in a D.C. motor with independent or shunt excitation. Operation in constant power. 11.- Speed control at constant torque. 12.- Series D.C. motor: starting, speed variation, inversion and braking. 13.- Speed-intensity characteristic curve in a D.C. motor with series excitation. 14.- Torque-current characteristic curve in a D.C. motor with series excitation. 15.- The D.C. motor with series excitation as universal motor. The Synchronous Machine (with motor EMT 6) 16.- Starting, voltage and frequency regulation in a three-phase alternator. 17.- Net coupling of a three-phase alternator. 18.- Characteristic curve of an alternator without load. 19.- Characteristic curve of an alternator in short circuit. 20.- Characteristic curve of an alternator with load. 21.- Synchronous motor starting. The Asynchronous Machine (with motors EMT 7/ 8/ 9/ 10/ 11/ 16/ 17). 22.- Morley diagrams. 23.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 24.- Test without load of an asynchronous motor with rotor in short circuit. 25.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 26.- Starting of a three-phase asynchronous motor with the wound rotor. 27.- Test without load of a three-phase asynchronous motor with the wound rotor. 28.- Test with load of a three-phase asynchronous motor with wound rotor. 29.- Starting and turn sense inversion of a single-phase motor with capacitor. 30.- Test without load of a single-phase asynchronous motor. 31.- Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.- The Universal motor with D.C. supply. 33.- Speed-current characteristic of an Universal motor with D.C. supply. 34.- Torque-intensity characteristic in the D.C. Universal motor. 35.- The universal motor eith A.C. supply. The Repulsion motor (with motor EMT 14) 36.- Starting and inversion of a single-phase repulsion motor. 37.- Test of a single-phase repulsion motor without load. 38.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor (with motor EMT 18) 39.- Brushless motor starting. 40.- Speed control and change of the turn sense. The Dahlander motor (with motor EMT 9) 41.- Dahlander motor starting. 42.- Different working speeds. 43.- Changing the different speeds of Dahlander motor while working. The Stepper motor (with motor EMT 19) 44.- Stepper motor starting. 45.- Steps control. 46.- Rotation sense change. The Reluctance motor ( with motor EMT21) 47.- Star connection of the reluctance motor. 48.- Delta connection of the reluctance motor. 49.- Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) Common Electrical Machines Base Units: (continuation) EME/M. Electrical Machines Unit (intermediate option) More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristics curve. 5.- Characteristic regulation curve of a dynamo. 6.- Speed control at constant torque. 7.- Series D.C. motor: starting, speed variation, inversion and braking. The Synchronous Machine: 8.- Starting, voltage and frequency regulation in a three-phase alternator. 9.- Characteristic curve of an alternator without load. 10.- Characteristic curve of an alternator in short circuit. 11.- Characteristic curve of an alternator with load. 12.- Synchronous motor starting. The Asynchronous Machine: 13.- Morley diagrams. 14.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 15.- Test without load of an asynchronous motor with rotor in short circuit. 16.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 17.- Starting and turn sense inversion of a single-phase motor with capacitor. 18.- Test without load of a single-phase motor. 19.- Test in load of the single-phase motor. The Universal motor: 20.- The universal motor with D.C. supply. 21.- Speed-current characteristic of an Universal motor with D.C. supply. 22.- Torque-intensity characteristic in the D.C. Universal motor. 23.- The Universal motor eith A.C. supply. The Repulsion motor: 24.- Starting and inversion of a single-phase repulsion motor. 25.- Test of a single-phase repulsion motor without load. 26.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor: 27.- Brushless motor starting. 28.- Speed control and change of the turn sense. The Dahlander motor: 29.- Dahlander motor starting. 30.- Different working speeds. The Reluctance motor: 31.- Star connection of the reluctance motor. 32.- Delta connection of the reluctance motor. 33.- Revolution sense and inversion of rotation. EME/B. Electrical Machines Unit (basic option) SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. DC supply 200 V dc with fuses. Connection Key. Emergency stop push button. Two push buttons (1NO + 1NC). * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 300 x 180 x 120 mm. approx. Weight: 5 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 59 PRACTICAL POSSIBILITIES The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- Dynamos with series and shunt excitation. 3.- Speed control at constant torque. 4.- Series D.C. Motor: starting, speed variation, inversion and braking. The Asynchronous Machine: 5.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 6.- Test without load of an asynchronous motor with rotor in short circuit. The Universal motor: 7.- The Universal motor with D.C. supply. www.edibon.com 4.- Electricity PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. Two double switches (1 NO + 1 NC in each one) Push Button (1 NC + 1 NO). Three contactors with 2 NO and 1 NC. DC supply 200 V dc with fuses. Connection Key Emergency stop push button. * Minimum recommended measurement units: (see Section “2”) 2 Digital multimeters. Recommended measurement units: (see Section “2”) EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 25 Kg. approx. 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) (continuation) Measurement Units The measurement units let us extract information from the experimental unit (EME), thus allowing further process of the data. We can get values of currents, voltages, resistance, etc. for further analysis. MULT. Digital Multimeter SPECIFICATIONS SUMMARY Digital multimeter. Voltage and current meter. Resistances and capacitors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAL. Network Analyzer Unit 4.- Electricity SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals, for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EALD. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC). SPECIFICATIONS SUMMARY This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ±0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 60 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) Measurement Units (continuation) EALDG. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC) + Oscilloscope Display SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES 4.- Electricity This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Steel box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display and oscilloscope display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAM-VA. Analog Measurement Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit allows to analyze the different voltages and currents involved in a circuit through a simple frontal panel that includes analog measurement instruments. Metallic box. 4 Voltmeters. - A.C. Measuring Instruments with moving iron. - Voltmeter with measuring range from 0 to 500Vac. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Ammeters. - A.C. Measuring Instruments with moving iron. - Ammeter with measuring range of 0 to 5A. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Analog inputs for each meter. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf MUAD. Power Data Acquisiton System. (see page 68) Page 61 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) Loads: RLC3R. Resistive, Inductive and Capacitive Loads Module 3 SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES When you brake an electrical machine, the electrical energy has to be dissipated. Loads provide this function, the dissipation of energy. Depending on the experiment, the dissipating load has to be resistive, inductive or capacitive. EDIBON recommends having the three kinds, if a good understanding on the subject is pursued. Our Resistive, Capacitive and Inductive Loads Module (RCL3R) offers: Single and Three-phase resistances. Single and Three-phase inductances. Single and Three-phase capacitors. Metallic box. Diagram in the front panel. Variable resistive loads: 3 x [ 150 W (500 W) ]. Fixed resistive loads: 3 x [ 150 W (500 W) + 150 W (500 W) ]. Inductive loads: 3 x [ 0, 33, 78, 140, 193, 236 mH ].(230V /2 A) Capacitive loads: 3 x [ 4 x 7 mF ]. (400V) Dimensions: 490 x 450 x 470 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 4.- Electricity Individual Elements IND CON PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY When a simpler and cheaper option is preferred when studying the use of loads in electrical machines, EDIBON gives the choice of acquiring single components. They are offered as single independent components to be mounted by the student. -IND. Inductance: From 33 to 236 mH, or similar. -CON. Box of Condensers: 7µF or similar. -REV. Variable Resistance: 0-150Ù (500W), or similar. -REF. Fixed Resistance : 150Ù (500W), or similar. REV More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf REF 4 Motors EDIBON has a wide range of electric motors. The motors supplied include connectors, couplings, standard motor support, etc. SPECIFICATIONS SUMMARY EMT2 EMT3 EMT1 EMT5 EMT4 EMT6 EMT8 EMT7 EMT9 EMT11 EMT12 EMT10 EMT15 EMT16 EMT14 EMT19 EMT17 EMT20 Available Motors EMT1. D.C. Independent excitation motor-generator. EMT2. D.C. Series excitation motor-generator. EMT3. D.C. Shunt excitation motor-generator. EMT4. D.C. Compound excitation motor-generator. EMT5. D . C . S h u n t - s e r i e s compound excitation motor. EMT6. A . C . S y n c h r o n o u s alternator motor. EMT7. Asynchronous three-phase motor of squirrel cage. EMT8. Asynchronous three-phase motor with wound rotor. EMT9. Dahlander three-phase (two-speeds). EMT10. Asynchronouts three-phase motor of two independent speeds. EMT11. Asynchronous single-phase motor with starting capacitor. EMT12. Universal motor (singlephase). EMT14. Repulsion motor, singlephase with short-circuited brushes. EMT15. D.C. Permanent magnet motor. EMT16. Asynchronous single-phase motor with starting and running capacitor. EMT17. Three-phase motor of squirel c a g e w i t h “ Y ” connection. EMT18. D.C. Brushless motor. EMT19. Stepper motor. EMT20. Asynchronous single-phase motor with split phase. EMT21. Three-phase Reluctance motor. EMT22. Single-phase Shaded Pole motor. PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/ 2/ 3/4/5/15) 1.-Preparation,regulationandinversionin adynamowithindependentexcitation. 2.-Thedynamocharacteristiccurvewithout load. 3.-Dynamos with series and shunt excitation. 4.-Dynamoexternalcharacteristiccurve. 5.-Dynamo characteristic regulation curve. 6.-Speed variation, inversion and stop of D.C. motor with independent excitation. 7.-Speed-armature current characteristic curve in a D.C. motor with shunt or independentexcitation. 8.-Torque-current characteristic curve in a D.C. Motor with shunt or independentexcitation. 9.-Torque-speed characteristic curve in a D.C. Motor with shunt or independent excitation. 10.-Speed-excitation current characteristic curve in a D.C. Motor with independent or shunt excitation. Operation in constantpower. 11.-Speedcontrolatconstanttorque. 12.-Series D.C. Motor: starting, speed variation,inversionandbraking. 13.-Speed-intensity characteristic curve inaD.C.Motorwithseriesexcitation. 14.-Torque-current characteristic curve inaD.C.Motorwithseriesexcitation. 15.-The D.C. Motor with series excitation asuniversalmotor. The Synchronous Machine (with motor EMT6) 16.-Starting, voltage and frequency regulation in a three-phase alternator. 17.-Net coupling of a three-phase alternator. 18.-Characteristic curve of an alternator withoutload. 19.-Characteristic curve of an alternator inshortcircuit. 20.-Characteristic curve of an alternator withload. 21.-Synchronousmotorstarting. The asynchronous Machine (with motors EMT7/8/9/10/11/16/17) 22.-Morleydiagrams. 23.-Starting process of a three-phase asynchronous motor with rotor in shortcircuit. 24.-Test without load of an asynchronous motorwithrotorinshortcircuit. More information in: 25.-Test with load of a three-phase www.edibon.com/products/catalogues/ asynchronous motor with rotor in en/units/electricity/machines/ shortcircuit. LIMEL.pdf Page 62 26.-Starting of a three-phase asynchronous motor with the woundrotor. 27.-Test without load of a three-phase asynchronous motor with the woundrotor. 28.-Test with load of a three-phase asynchronous motor with wound rotor. 29.-Starting and turn sense inversion of a single-phase motor with capacitor. 30.-Test without load of a single-phase motor. 31.-Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.-The universal motor with D.C. Supply. 33.-Speed-current characteristic of an UniversalmotorwithD.C.Supply. 34.-Torque-intensity characteristic in theD.C.Universalmotor. 35.-The universal motor eith A.C. Supply. The repulsion motor (with motor EMT 14) 36.-Starting and inversion of a singlephaserepulsionmotor. 37.-Test of a single-phase repulsion withoutload. 3 8 . -Te s t o f a s i n g l e - p h a s e asynchronous repulsion motor withA.C. The Brushless motor (with motor EMT 18) 39.-Brushlessmotorstarting. 40.-Speed control and change of the turnsense. The Dahlander motor (with motor EMT 9) 41.-Dahlandermotorstarting. 42.-Differentworkingspeeds. 43.-Changing the different speeds of Dahlandermotorwhileworking. TheSteppermotor(withmotorEMT19) 44.-Steppermotorstarting. 45.-Stepscontrol. 46.-Rotationsensechange. The Reluctance motor (with motor EMT21) 47.-Star connection of the reluctance motor. 48.-Delta connection of the reluctance motor. 49.-Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 5 (continuation) Brakes The importance of Brakes comes when we want to adjust the motor speed, measure the torque given, or stop the motor. FRE-FE. Electronic Brake SPECIFICATIONS SUMMARY This unit is based in two elements: 1.- Module -metallic box: Power supply:1 phase, 200-240V. Rated output capacity:0.75 KW. Output frequency range: 0.2 to 400 Hz. Display to visualize voltage (V), Current (A), and Frequency (Hz). Brake resistance included. Torquemeter. R.p.m. Meter. Connectors. 2.- Braking motor mounted on a bench-support. Connection wire between elements “1” and “2”. Electrical supply: 220V a.c. - 110V a.c., single-phase + ground. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf DI-FRE. Pendular Dynamo Brake SPECIFICATIONS SUMMARY 4.- Electricity Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Torque measured with lever and weights, by combining the mechanical torque and electrical torque. Security connectors. Bench-support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREND. Dynamo Brake SPECIFICATIONS SUMMARY Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Connectors. Bench - support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRENP. Magnetic Powder Brake SPECIFICATIONS SUMMARY The unit consists of a magnetic powder brake, a control module an a tachometer for the speed measurement. The control module allows setting the nominal torque of the brake through a potentiometer. It has two terminals to measure a voltage in direct proportion to the current supplied to the brake, therefore, to the exerted torque. The unit has a tachometer connected to its axis. The unit also includes a fuse and a thermal relay to avoid eventual damages. Max. power: 400 W, limited at 220W. Voltage: 24 Vac. Max. torque: 5 Nm. Max. R.P.M.: 3000. It is equipped with temperature probe to stop the braking action. Electrical supply: 220 Vac. - 110 Vac. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREPR. Prony Brake SPECIFICATIONS SUMMARY Prony brake with resistant ribbon. Mechanical braking action and dynamometer. Max. Power: 500 W. Max. Torque: 4Nm. Max. R.P.M.: 3000. Max. Time: 30 seconds. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRECP. Eddy Current Brake SPECIFICATIONS SUMMARY Max. Power: 500 W. Voltage: 120 Vdc. Max. Torque: 3Nm. Max. R.P. M.: 3000. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 63 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) 6 Transformers 4.- Electricity ETT. Three-phase and Single-phase Transformers Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Metallic box. Diagram in the front panel. Single-phase transformer: Nominal power: 500 VA. Transformation ratio: 400 / 230 V. Inlets: 400 V and 230 V (in the primary). Number of secondary coils: 2. Output voltage in the secondary: 115 (each one). Maximum current in the primary: 1.5 A (for each voltage of 400 V). 3 A (for each voltage of 230 V). Three-phase transformer in pillars: Nominal power: 1000 VA. Transformation ratio: 380/3 x 127 V. Inlets: 220 V and 380 V (in the primary). Outlet voltage in the secondary: 3 x 127 V (each phase). Maximum current in the primary: 2 A (for a voltage of 380 V). 2 A (for a voltage of 220 V). Connection modes: Primary: Star, triangle / Secondary: Star, triangle, zigzag, six-phase and triple star. Electrical supply: For Single-phase transformer: 400-230 V / 50 Hz. or 60 Hz. For Three-phase transformer: 380-220 V / 50 Hz. or 60 Hz. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. 1.- Measurement of the transformation Ratio. 2.- Rehearsal of a single-phase transformer in open circuit. 3.- Rehearsal of a single-phase transformer in short circuit. 4.- Rehearsal of a single-phase transformer in load. 5.- Rehearsal of a three-phase transformer in open circuit. 6.- Rehearsal of a three-phase transformer in short circuit. 7.- Autotransformer tests. 8.- Connection modes tests: Start/delta/Zig-Zag/6-phase/triple star. 9.- Transformer ratio variation tests. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TPPT. Three-phase Power Transformer Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The “TPPT” unit is formed by a steel box, which contains a three-phase power transformer. In the front panel of the box are located the terminals for both primary and secondary terminals for different power supply inputs and outputs. In the backside are located the fuses to protect the transformer. Diagram in the front panel. Power: 1000 VA. Module 1: Primary winding It includes a three-phase winding which can be connected externally in either star or triangle, each phase winding has a neutral terminal, a 146V a.c. intermediate terminal and 220V a.c. terminal. Module 2: Secondary winding It includes a three-phase winding which can be connected externally in either star of triangle. Each phase winding has a neutral terminal, a 127V a.c. intermediate terminal and a 220V a.c. terminal. This unit can be used to make 6 different a.c. connection types: -Star (380V). - Triangle (380V). -Triangle (220V). - Triangle (380V). -Star (380V). - Star (220V). -Triangle (220V). - Star (220V). -Star (380V). - Triangle (127V). -Triangle (220V). - Triangle (127V). Electrical supply: 380-220 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EMPTA. Auxiliary Transformer and Protection Module SPECIFICATIONS SUMMARY Metallic Box. Diagram in the front panel. Input and output connectors. Thermal magnetic unit 16 A ., 2 poles. Differential 25 A., 30 mV., 230 V. Reversible auto-transformer 125-220 (1000 VA). Conversion from 127V. 60Hz to 220V. 50Hz. Conversion from 220V. 50Hz to 127V. 60Hz. Differential electrical protection. Thermal magnetic protection. Required services: Input: 220V. 50Hz or 127V. 60Hz. Electrical supply: 220 V a.c. - 127 V a.c. Dimensions: 300 x 120 x 190 mm. approx. Net weight: 3Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: - AUTR. - TRANS. SPECIFICATIONS SUMMARY Variable Auto-transformer. Single-phase transformer. Input and output connectors. Single phase transformer, 400 Vac/230 Vac, 400 VA. Ground connector. - TRANS/3.Three-phase transformer. Input and output connectors. Three phase transformer, 400 Vac/230 Vac, 1000 VA TRANS More information in: www.edibon.com/products/catalogues/en/ TRANS/3 units/electricity/machines/LIMEL.pdf Page 64 PRACTICAL POSSIBILITIES 1.- Conversion from 127V/60Hz to 220V/ 50Hz. 2.- Conversion from 220V/50Hz to 127V/ 60Hz. 3.- Differential electrical protection. 4.- Thermal magnetic protection. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 7 (continuation) DC Motor Speed Control VVCC. DC Motor Speed Controller This unit varies the speed of a DC motor for control applications. It works with any DC motor available. Metallic box. Front panel including: Excitation connection (2 connectors). Rotor connection (2 connectors). Tachodynamo connection (2 connectors). Parameters self adjustment (torque control and speed control): Motor torque regulator. Motor speed regulator. State leds indicators. START/STOP speed controller switch. ON/OFF main switch. Maximum power: 550W. Maximum torque: 2.6 Nm Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 10 Kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a certain frequency. 3.- Starting carrying out by defined ramp. 4.- Braking possibility until a certain speed and recovery. 4.- Electricity SPECIFICATIONS SUMMARY More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCC/M. DC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consists in a variable transformer followed by a rectifier bridge and an anti-ripple capacitor with a resistor to get discharged. Metallic box. Regulated voltage output up to ~320 Vdc. Maximum current output 2 A. Front panel including: Connections: Positive, negative and ground connections. ON/OFF switch. The top side of the unit include a wheel to adjust the DC output voltage up to ~320 Vdc. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES -VVCC/B. DC motors speed controller, with no other elements. Maximum power: 550W. Maximum torque: 2.6 N.m. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 65 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 8 (continuation) (continuation) AC Motor Speed Control VVCA. AC Motor Speed Controller SPECIFICATIONS SUMMARY 4.- Electricity This is a unit for varying the speed of an AC motor for control applications. It works with any AC motor available. This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a direct current motor. It consists basically on a rectifying phase coupled to another inverter phase, with a capacitor in parallel between them. By varying the shooting frequency of the IGBT, we obtain an alternating output at a variable frequency which is applied to the asynchronous motor. Metallic box. Circuit diagram in front panel. It has a control panel in order to introduce the parameters of the motor that is going to be used and the output frequency. In addition, through it, we can carry out several programming. It also has a series of terminals where we connect the digital and analog inputs and the relay and transistor outputs. Maximum power: 750 W. Parameter self adjustment. Analog/digital parameter inlets through panel. Turn inversion while running. Analog parameter visualization. Voltage Input : Frequency set according to external command: up to 50Hz. Reversible operation using +/- signal: 0 to +/-10 V. PID control. Current input: Frequency set according to the analog input current command: up to 50 Hz. Reversible operation: 20 to 4mA. PID control. 5 Digital inputs that can be configured by the user. 1 outlet to alarm relay. 2 transistor internal outlets. Maximum load current: 50 mA. Leak current at OFF: 0.1 mA. Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 600 x 600 x 150 mm. approx. Weight: 30 kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a frequency given by the panel. 3.- Working at a frequency given by an analog input (potentiometer). 4.- Turn inversion. 5.- Display of analog output. 6.- Digital inputs configuration. 7.- Outputs from alarm to relay. 8.- Outputs from alarm to transistor. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCA/M. AC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consist in a simple AC motor speed controller. Metallic box. Output: 3 PH, 3.0 KVA, 220 V, 1-50 Hz., 8.0 A. Overload current thermal protection. ON/OFF switch. It has two blocks in the front panel: Speed control: Start/Stop switch. Speed control potenciometer. Connections to motor: Three-phase connection to AC motor. Ground connection. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elemenents: SPECIFICATIONS SUMMARY -VVCA/B. AC motors speed controller, with no other elements. Frequency from 0 to 60Hz. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 66 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 9 (continuation) PLC (Programmable Logic Controller) The Programmable Logic Controller is a device designed for real time control of sequential processes in an industrial environment. In this case, EDIBON has developed this PLC module for controlling the Electrical Machines Unit “EME”. PLC-PI. PLC Module for the Control of Industrial Processes PLC-PI + PLC-SOF This module has been designed for the Control of Industrial Processes. The application has been developed to be used with any individual electric machine. PLC-PI. Unit: Metallic box. Circuit diagram in the front panel. Front panel: Digital inputs(X) and Digital outputs (Y) block: 16 Digital inputs. 14 Digital outputs. Analog inputs block: 16 Analog inputs. Analog outputs block: 4 Analog outputs. Touch screen. Back panel: Power supply connector. 2 A Fuse. RS-232 connector to PC. Inside: Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable. Panasonic PLC: High-speed scan of 0.32 msec. for a basic instruction. Program capacity of 32 Ksteps, with a sufficient comment area. Equipped with a USB communication port. High-speed counter. Multi-point PID control. Digital inputs/outputs and analog inputs/outputs Panasonic modules. RS232 Communication wire, to computer (PC). PLC-SOF. PLC Control Software: The software package is always included with the PLC-PI unit, since it is the necessary application to program the PLC-PI from the computer. Electrical supply single-phase, 220 V. - 110 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf PRACTICAL POSSIBILITIES 1.- Control of the particular unit process through the control interface box without the PC. 2.- PID control. 3.- Visualization of all the sensors values used in the particular unit process. 4.- Calibration of all sensors included in the particular unit process. 5.- Hand on of all the actuators involved in the particular unit process. 6.- Realization of different experiments, in automatic way, without having in front the particular unit. (This experiment can be decided previously). 7.- Simulation of outside actions, when there are not any hardware element present. 8.- PLC hardware general use and manipulation. 9.- PLC process application for the particular unit. 10.- PLC structure. 11.- P L C i n p u t s a n d o u t p u t s configuration. 12.- PLC configuration possibilities. 13.- PLC program languages. 14.- PLC different programming standard languages (ladder diagram (LD), structures text (ST), instructions list (IL), sequential function chart (SFC), function diagram (FBD). 15.- New configuration and development of new process. 16.- Hand on an established process. 17.- Visualization of results and comparisons with the particular unit process. 18.- Possibility if creating new process in relation with the particular unit process. 19.- PLC Programming exercises. 20.- O w n P L C a p p l i c a t i o n s i n accordance with teacher and student requirements. EDIBON FP-X/CPU. PLC, with no other elements SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Inputs: 8. Input Commons: 1. Output: 6. Output commons: 4. Execution time: 0.32µs. Data memory: 12,285. Bit memory: 4096. High Speed Counter. Interrupt: 8 input interrupt X0 to X7. Constant time interrupt (0.5ms to 30sec). Interrupt subroutine jump time: 10 micro sec . PID: PID algorithm (with auto tuning). I-PD algorithm (with auto tuning).10ms cycle to 100s cycle. Dimension (w, h, d): 60 x 90 x 79mm. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 10 Tachogenerator TECNEL/T. Tachogenerator SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The Tachogenerator, as a speed transducer, provides a means of converting the rotational speed into an analog voltage signal. Thus, it is mainly used for measuring the motor speed. The TECNEL/T is an automatic unit, that could be permanently connected to the main rotor. Output voltage gradient: 30 +/- 3% V /1000 r.p.m. Electrical supply: continuous d.c. output 0-100 V. Dimensions: 200 x 150 x 50 mm. approx. Weight: 1Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TECNEL/TM. Hand Tachometer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This is a hand optical tachogenerator. It cannot be attached to the motor, what implies that the measurements have to be taken manually. Page 67 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: (continuation) Data Acquisition 11 MUAD. Power Data Acquisition System 3 4 “n” EME unit Electric power interface box (EPIB) Cable to computer (DAB) Connections points Data acquisition board 2 MUAD is the perfect link between the EME unit and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope. We easily connect the Electric Power Interface Box (EPIB) to the EME unit with the supplied cables (there are several connection points placed for it). The EPIB is connected to the PC through the Data Acquisition Board (DAB), and by using the Data Acquisition with Virtual Instrumentation Software, the student can get results from the undertaken experiment/practice, see them on the screen and work with them. Data acquisition software (MUAD/SOF) Cables to interface 1 Student post This MUAD System includes EPIB + DAB + MUAD/SOF: 4.- Electricity 1)Hardware : 1.1) EPIB. Electric power interface box ( dimensions: 300 x 120 x 180 mm. approx.): Interface that carries out the conditioning of the diverse signals that can be acquired in a process, for their later treatment and visualisation. Front panel separated in two: left-hand part for VOLTAGE sensors, and right-hand part for CURRENT Sensors. - 8 analog input channels. - Sampling range: 250 KSPS (Kilo samples per second). - 4 Tension sensors AC/DC, 400V. - 4 Current sensors. 1.2) DAB. Data acquisition board : PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI. Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KSPS (Kilo samples per second). Analog output: Number of channels=2. Resolution=16 bits, 1 in 65536. Digital Input/Output: Number channels=24inputs/outputs. Timing: Counter/timers=2. EPIB DAB 2) MUAD/SOF. Data acquisition software : Data Acquisition Software with Graphic Representation: Amicable graphical frame. Compatible with actual Windows operating systems. Configurable software allowing the representation of temporal evolution of different signals. Visualization of circuit tensions on the computer screen. Sampling rate up to 250 KSPS (Kilo samples per second) guaranteed. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf 12 Software CAI. Computer Aided Instruction Software System With no physical connection between motor and computer, this complete package consists on an Instructor Software (INS/SOF) totally integrated with the Student Software (EMT../SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. These, on the other hand, get a virtual instructor who helps them to deal with all the information on the subject of study. + Motor Instructor Software MUAD/SOF Student/Motor Software With the INS/SOF. Classroom Management Software Package (Instructor Software), the Teacher has a whole range of options, among them: - Organize Students by Classes and Groups. - Create easily new entries or delete them. - Create data bases with student information. - Analyze results and make statistical comparisons. - Print reports. - Develop own examinations. - Detect student’s progress and difficulties. ...and many other facilities. The Instructor Software is the same for all the motors, and working in network configuration, allows controlling all the students in the classroom. EMT../SOF. Computer Aided Instruction Software Packages (Student Software) Explains how to use the motor and run the experiments and what to do at any moment. Each motor has its own Student Software package. - The options are presented by pull-down menus and pop-up windows. - Each Software Package contains: Theory: that gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done, alongside the motors, showing how to complete the circuits and get the right information from them. Exams: set of questions presented to test the knowledge obtained. Available Student Software Packages: -EMT1/SOF. -EMT2/SOF. -EMT3/SOF. -EMT4/SOF. -EMT5/SOF. -EMT6 /SOF. -EMT7 /SOF. -EMT8 /SOF. -EMT9 /SOF. -EMT10/SOF. -EMT11/SOF. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. Asynchronous three-phase motor with wound rotor. Dahlander three-phase (two-speeds). Asynchronous three-phase motor with two independent speeds. Asynchronous single-phase motor with starting capacitor. -EMT12/SOF. -EMT14/SOF. -EMT15/SOF. -EMT16/SOF. -EMT17/SOF. -EMT18/SOF. -EMT19/SOF. -EMT20/SOF. -EMT21/SOF. -EMT22/SOF. Universal motor (single-phase). Repulsion motor, single-phase with short-circuited brushes. DC Permanent magnet motor. Asynchronous single-phase motor with starting and running capacitor. Three-phase motor of squirrel cage with “Y” connection. DC Brushless motor. Stepper motor. Asynchronous single-phase motor with split phase. Three-phase Reluctance motor. Single-phase Shaded Pole motor. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 68 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx. 4.4- Electrical Machines (continuation) ERP. Protection Relay Test: 4.- Electricity ERP-UB. Protection and Relay Test Unit SPECIFICATIONS SUMMARY This is a teaching unit which gives students theoretical and practical experience with several industrial relays. Unit designed for comprehensive investigations into the theory and practice of electrical power system protection. This unit is common for the relays modules type “ERP” and can use one or more relays. Anodized aluminium structure. Panels and main metallic elements in stainless steel. Floor-standing unit. It uses genuine industrial relays, not simulations, with full range of safety features incorporated throughout. Diagrams on the unit enable students to set up and perform practices and experiments with minimal supervision. Comprehensive controls, transformers, supplies and instrumentation. It includes desk space for users or students to work on, and mounting area for relays. It is supplied with relay support software. Selection of up-to-date numerical protection relays, specially adapted for educational use. (See available relays). Unit controls and instrumentations specifications: 0 to 10 A variable current supply.0 to 220 V variable voltage supply. 2 fault limiting resistors. Timed fault application circuit breaker. Configurable tapped transformer with delta or star secondary. Variable three-phase load star connected. Variable three-phase load delta connected. 2 sets of three-phase voltage transformers. 4 sets of threephase current transformers. Mains isolator. Test circuits: Configurable transformer test circuit. Relay test area. Transmission line model (5 x 50 km). Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 2500mm x 1000mm x 1800mm. Weight: 600 Kg. PRACTICAL POSSIBILITIES 1.- A wide range of practices and investigations into the performance and characteristics of a variety of different industrial relays. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-SFT. Overcurrent and Earth Fault Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of transformers, transmission lines and distribution schemes. Modern and robust enclosure (steel box) with carrying handles. Modern industrial over current and earth fault relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Three-phase earth and overcurrent: three independent stages, the first stage selectable from any of 12 IDMT curves, the remaining stages having a direct time characteristic (ANSI 50/51 and ANSI 50N/51N). Thermal overload protection (ANSI 49). High impedance restricted earth fault (ANSI 64N). Undercurrent (ANSI 37). Broken conductor detection (ANSI 46BC). Negative phase sequence overcurrent - two independent stages (ANSI 46). Selectable blocking. Circuit monitoring. Trend, fault and disturbance records. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 5%. Current: 1 A (A.C.). Frequency: 50 or 60 Hz.Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490mm x 400mm x 310mm. Weight: 10 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the characteristics and performance of an industrial over current and earth fault relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-SDND. Directional/Non Directional Overcurrent Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of generator and transformer schemes, overhead lines, underground cables and backup on high-voltage systems. Modern and robust enclosure (steel box) with carrying handles. Modern industrial directional/non directional overcurrent relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Three independent stages of directional/non-directional phase overcurrent (ANSI 50, ANSI 51, ANSI 67). Undercurrent (ANSI 37). Thermal overload protection (ANSI 49). Negative phase sequence overcurrent (ANSI 46). Overvoltage (ANSI 59). Undervoltage (ANSI 27). Directional/non-directional earth fault (ANSI 67N, ANSI 50N, ANSI 51N). Creating fault and disturbance records. Selectable blocking. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490mm x 400mm x 310mm. Weight: 15 Kg. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf Page 70 PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial directional/non directional overcurrent relay. 4.4- Electrical Machines (continuation) ERP. Protection Relay Test: (continuation) ERP-PDF. Differential Protection Relay Module SPECIFICATIONS SUMMARY For use with Protection and Relay Test Unit (ERP-UB) , to enable investigations into protection of transformers, autotransformers, generators and other apparatus with two windings. It demonstrates the characteristics of three-phase differential protection. Modern and robust enclosure (steel box) with carrying handles. Modern industrial differential protection relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Differential protection (ANSI 87). Thermal overload protection (ANSI 49). Definete time overcurrent protection (ANSI 50P, ANSI 50Q and ANSI 50N/G). Inverse time overcurrent protection (ANSI 51P, ANSI 51Q and ANSI 51N/G). Connection to the primary and secondary windings of the experimental is circuit via current transformers with ratio to suit the inputs of the relay. This provides an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 5%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial differential protection relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-MA. Feeder Management Relay Module PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial feeder management relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-PD. Distance Protection Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of overhead transmission lines. Modern and robust enclosure (steel box) with carrying handles. Modern industrial distance protection relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Full scheme phase and ground distance protection, up to five zones (ANSI 21G and ANSI 21P). Directional/non-directional earth fault (ANSI 50N, ANSI 51N, ANSI 67N). Directional/non-directional phase overcurrent (ANSI 50, ANSI 51, ANSI 67). Directional/nondirectional negative sequence overcurrent (ANSI 46, ANSI 67). Broken conductor. Thermal overload protection (ANSI 49). Creating fault and disturbance records. Blocking of any one protection element. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial distance protection relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf Page 71 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of overhead lines and underground cables. Modern and robust enclosure (steel box) with carrying handles. Modern industrial feeder management relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: 4 independent stages of directional/non-directional overcurrent (ANSI 50, ANSI 51, ANSI 67). Directional/non-directional earth fault (ANSI 50N, ANSI 51N, ANSI 67N). Sensitive directional/nondirectional earth fault. Sensitive directional earth fault. Wattmetric earth fault (ANSI 32N). Restricted earth fault (ANSI 64N). Directional/non-directional negative sequence overcurrent (ANSI 46, ANSI 67). Under and overvoltage (ANSI 27, ANSI 59). Thermal overload protection (ANSI 49). Residual overvoltage (ANSI 59N). Under and over frequency. Negative sequence overvoltage (ANSI 47). Selectable blocking. Broken conductor. Creating fault and disturbance records. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. issue:01/11 ELECTRICAL MACHINES. ADVANCED MODULE Ref: 0482 ITEM 1 / 2 REFERENCE DESCRIPTION QTY. 1 DI-FRE PENDULAR DYNAMO BRAKE 1,1 KW 1 2 PLC-PI PLC MODULE 1 3 EALDG NETWORK ANALYCER UNIT WITH COMPUTER DATA ACQUISITION + OSCILLOSCOPE (PC) + OSCILLOSCOPE DISPLAY 1 4 TECNEL TEACHING EQUIPMENT FOR STUDY OF POWER ELECTRONICS, COMPUTER CONTROLLED. (CONVERTERS: DC/AC+AC/DC+DC/DC+AC/AC). FORMED BY: TEACHING EQUIPMENT FOR STUDY OF POWER ELECTRONICS INCLUDING CONTROL INTERFACE DATA ACQUISITION BOARD COMPUTER CONTROL + DATA ACQUISITION + DATA MANAGEMENT SOFTWARE FOR TEACHING EQUIPMENT FOR STUDY OF POWER ELECTRONICS (CONVERTERS: DC/AC+AC/DC+DC/DC+AC/AC) 1 TECNEL.Unit DAB TECNEL/CCSOF 1 1 1 5 TECNEL/T TACHODYNAMO 60 V,1000 R.P.M 1 6 RCL3R RESISTIVE,INDUCTIVE AND CAPACITIVE LOADS MODULE 1 7 EMT15 (1) D.C. PERMANENT MAGNETS MOTOR 1 8 EMT17 (1) THREE-PHASE MOTOR OF SQUIRREL CAGE WITH "Y" CONNECTION 1 9 SERIN-CC INDUSTRIAL SERVOSYSTEMS TRAINER, USING DSP (FOR D.C. MOTORS), COMPUTER CONTROLLED. FORMED BY: INDUSTRIAL SERVOSYSTEMS TRAINER USING DSP (FOR D.C. MOTORS) DATA ACQUISITION BOARD COMPUTER CONTROL + DATA ACQUISITION + DATA MANAGEMENT SOFTWARE FOR NDUSTRIAL SERVOSYSTEMS TRAINER, USING DSP (FOR D.C. MOTORS) 1 SERIN-CC/BOX DAB SERIN-CC/CCSOF 1 1 1 10 SERIN-CC/CAL COMPUTER AIDED LEARNING SOFTWARE FOR INDUSTRIAL SERVOSYSTEMS (FOR D.C. MOTORS) (RESULTS CALCULATION AND ANALYSIS) 1 11 SERIN-CA INDUSTRIAL SERVOSYSTEMS TRAINER, USING DSP (FOR A.C. MOTORS), COMPUTER CONTROLLED. FORMED BY: INDUSTRIAL SERVOSYSTEMS TRAINING USING DSP (FOR A.C. MOTORS), INCLUDING CONTROL INTERFACE DATA ACQUISITION BOARD COMPUTER CONTROL + DATA ACQUISITION + DATA MANAGEMENT SOFTWARE FOR NDUSTRIAL SERVOSYSTEMS TRAINER, USING DSP (FOR A.C.. MOTORS) 1 SERIN-CA/BOX DAB SERIN-CA/CCSOF 1 1 1 12 SERIN-CA/CAL COMPUTER AIDED LEARNING SOFTWARE FOR INDUSTRIAL SERVOSYSTEMS (FOR D.C. MOTORS) (RESULTS CALCULATION AND ANALYSIS) 1 13 EMT18 (1) BRUSHLESS MOTOR 1 14 EMT20 (1) SPLIT PHASE MOTOR 1 15 EMT21 (1) THREE-PHASE RELUCTANCE MOTOR 1 16 EMT21 (1) THREE-PHASE RELUCTANCE MOTOR 1 Ref: 0482 2 / 2 ITEM REFERENCE DESCRIPTION QTY. 17 EMT22 (1) SINGLE-PHASE SHAHED POLE MOTOR 1 18 0452PARTS COMPONENTS AND SPARE PARTS 1 19 0452PA COMPLEMENTARY ITEM 1 20 0452IYPM INSTALLATION AND STARTING UP 1 21 0452CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 22 0452TD TEACHING TECHNIQUES "KNOW-HOW" 1 23 0452MANU DOCUMENTATION AND MANUALS 1 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages 2.6- Industrial Electronics Electronics 2.- Electronics TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters: DC/AC+AC/DC+DC/DC+AC/AC) Always included in the supply: Teaching Technique used RTC. EDIBON Real Time Control System Control Interface included in the unit 1 Unit: TECNEL. Teaching Unit for the Study of Power Electronics, including Control Interface. 2 3 Data Acquisition Board Software for: - Computer Control - Data Acquisition - Data Management 4 Cables and Accessories 5 Manuals (Converters: DC/AC+ AC/DC+DC/DC+AC/AC). PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Items supplied as standard TECNEL Unit: Unit with Computer Control and Data Acquisition System designed to study the basis of Power Electronics. It allows students to study AC/DC, DC/AC, DC/DC, AC/AC converters. Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. Front panel: Diodes module: 6 diodes. Thyristors module: 6 thyristors. IGBTS Module: 6 IGBTS. Snubber net. Sensors module: 4 voltage sensors, 2 current sensors. Power supply connections for Vr, Vs, Vt, Neutral and Ground. Practices schemes. Back panel: Data Acquisition Board Connector (SCSI connector). Tachodynamo connector. Main fuses (Vr, Vs, Vt) and LEDs. Circuit breaker (main switch). Single-phase driver. Three-phase driver. IGBT driver. TSI board. PIC board. SKHI61 board. Four relays board. 2 Three-phase relays. Commuted power supply. Three-phase magnetothermal. Control interface. 2 DAB. Data Acquisition Board: PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to: 250 KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs. 3 TECNEL/CCSOF.Computer Control+Data Acquisition+Data Management Software: Registration and visualization of all process variables in an automatic and simultaneously way. Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters. Management, processing, comparison and storage of data. Sampling velocity up to 250,000 data per second. Comparative analysis of the obtained data, after to the process and modification of the conditions during the process. 4 Cables and Accessories, for normal operation. 5 Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =Unit: 490 x 330 x 310 mm. Weight: 40 Kg. 1 1.- Single phase half-wave rectifier with load R. 2.- Single phase half-wave rectifier with load R-L. 3.- Single-phase half-wave rectifier with R-L load with free wheeling diode (FWD). 4.- Single-phase full-wave rectifier. 5.- Three-phase half-wave uncontrolled rectifier. 6.- Three-phase full-wave uncontrolled rectifier. 7.- Single-phase half-wave controlled rectifier. 8.- Single-phase full-wave controlled rectifier. 9.- Single-phase full-wave controlled rectifier with a DC motor. 10.- Three-phase full-wave completely controlled. 11.- S i n g l e - p h a s e s e m i controlled rectifier. 12.- Three-phase full-wave semi-controlled rectifier. 13.- Chopper. 14.- Single-phase square-wave inverter. 15.- Single-phase displaced phase inverter. 16.- Single-phase inverter. PWM control. 17.- Three -phase inverter. PWM control with R load and R-L load. 18.- Three -phase inverter. PWM control with AC motor. 19.- Alternating regulators: R and R-L load. 20.- Asynchronous three-motor with rotor in short circuit (squirrel cage). More information in: www.edibon.com/products/catalogues/en/units/electronics/industrial/ TECNEL.pdf TECNEL/B. Computer Controlled Basic Teaching Unit for the Study of Power Electronics. (Converters: AC/DC+AC/AC) Always included in the supply: Teaching Technique used RTC. EDIBON Real Time Control System Control Interface included in the unit 2 3 Data Acquisition Board Software for: - Computer Control - Data Acquisition - Data Management 4 Cables and Accessories 5 Manuals 1 Unit: TECNEL/B. Basic Teaching Unit for the Study of Power Electronics, including Control Interface. (Converters: AC/DC+AC/AC). SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Items supplied as standard TECNEL/B Unit: Unit with Computer Control and Data Acquisition System designed to study the basis of Power Electrics. It allows students to study AC/DC, AC/AC converters. Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. Front panel: Diodes module: 6 diodes. Thyristors module: 6 thyristors. Snubber net. Sensors module: 4 voltage sensors, 2 current sensors. Power supply connections for Vr, Vs, Vt, Neutral and Ground. Practices schemes. Back panel: Data Acquisition Board connector (SCSI connector). Tachodynamo connector. Main fuses (Vr, Vs, Vt) and LEDs. Circuit breaker (main switch). Single-phase driver. Three-phase driver. TSI board. Four relays board. 2 Three-phase relays. Commuted power supply. Threephase magnetothermal. Control Interface. 2 DAB. Data Acquisition Board: PCI Data acquisition National Instruments board to be placed in a computer slot. 16 Analog inputs. Sampling rate up to: 250 KS/s. 2 Analog outputs. 24 Digital Inputs/Outputs. 3 TECNEL/B/CCSOF.Computer Control+Data Acquisition+Data Management Software: Registration and visualization of all process variables in an automatic and simultaneously way. Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters. Management, processing, comparison and storage of data. Sampling velocity up to 250,000 data per second. Comparative analysis of the obtained data, after to the process and modification of the conditions during the process. 4 Cables and Accessories, for normal operation. 5 Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =Unit: 490 x 330 x 310 mm. Weight: 35 Kg. 1 More information in: www.edibon.com/products/catalogues/en/units/electronics/industrial/TECNEL-B.pdf Page 26 1.- Single phase half-wave rectifier with load R. 2.- Single phase half-wave rectifier with load R-L. 3.- Single-phase half-wave rectifier with R-L load with free wheeling diode (FWD). 4.- Single-phase full-wave rectifier. 5.- T h r e e - p h a s e h a l f - w a v e uncontrolled rectifier. 6.- Three-phase full-wave uncontrolled rectifier. 7.- Single-phase half-wave controlled rectifier. 8.- Single-phase full-wave controlled rectifier. 9.- Single-phase full-wave controlled rectifier with a DC motor. 10.- Three-phase full-wave completely controlled. 11.- Single -phase semi- controlled rectifier. 12.- Three -phase full-wave semicontrolled rectifier. 13.- Alternating regulators: R and R-L load. 2.6-Basic Industrial Electronics 2.1Electronics (continuation) 2.- Electronics SERIN/CA. Computer Controlled Industrial Servosystems Trainer (for AC motors) Always included in the supply: Teaching Technique used RTC. EDIBON Real Time Control System 2 Control Interface Box Motor 3 Cables and Accessories Unit: SERIN/CA. Industrial Servosystems Trainer (for AC motors) 1 Software for: - Computer Control - Data Acquisition - Data Management 4 Manuals SPECIFICATIONS SUMMARY Items supplied as standard SERIN/CA Unit: The SERIN/CA trainer consists on an Control Interface Box connected to a three-phase motor and to a PC. The control interface has a resolver for three-phase motors that controls the speed, position and current of the motor. The RS232 communication between the control interface and the PC provides the SERIN/CA the possibility of commanding the motor from the PC and visualize the most important signals of the motor. Velocity, Position and Torque Control. It allows predefined moves and programming. Control Interface Box: Front panel: 3 Digital outputs: They have a green LED that indicates if the output is active or not. Emulative encoder outputs: two pair of outputs (CH A Out, CH B Out and their respective denied outputs) that are TTL signals of incremental position generated by the resolver feedback, and one pair of outputs (CH S Out and their denied) that TTL works as marker of pulses. Analog output 4 (relay). Analog outputs of the DAC monitor: these analog outputs are monitored points of general character. 6 digital inputs for those signals that are introduced to enable the different available functions in the software. 6 buttons to enable the digital inputs. 6 switches, with the same function as the buttons, but with the only difference that they are switches. Switch outfitter of digital inputs: there is a switch that enables the digital inputs. Analog input: this input allows an analog use directly of the user. It is an A/D input. Voltage supply: 3 sources of D.C. in the unit (+24 V. , +12V., and -12V. DC.) 2 Potentiometers. Ignition switch. Back panel: Voltage supply (220 V A.C.). Three-phase output when solving: it is a three-phase output that feeds when you are solving and, therefore, allows their movement. Connection port in series: to connect the unit with the PC by the port in series. Connection with the feedback: it is a connection with the motor feedback. It allows the encoder to manage the motor. Motor: AC motor, 0.7kW, 2.8A ac, 4200 rpm, 320V dc. Sensor RESOLVER :1 Speed, 1X/RX, 3 phase. 2 SERIN/CA/CCSOF.Computer Control+Data Acquisition+Data Management Software: Registration and visualization of signals in an automatic and simultaneously way. Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Comparative analysis of the obtained data, after to the process and modification of the conditions during the process. 3 Cables and Accessories, for normal operation. 4 Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =Unit: 490 x 330 x 310 mm. Weight: 40 Kg. Motor:410 x 170 x 150 mm. Weight: 5 Kg. PRACTICAL POSSIBILITIES 1 1.-Homing. 2.-Clutch/Control. 3.-Turn movement (w/correction phase). 4.-Registration movements. 5.-Dry movements. 6.-Stop and blockade. Transitory states. 7.-Stop and blockade. Influence on the filtered velocity. 8.-Transitory velocity study. 9.-Feedback gain manage. 10.- M o d i f i c a t i o n of Fe e d b a c k Parameters and Phases U, V and W. 11.-Use and modification of the feedback filters. 12.-Phase voltages U, V and W showing. More information in: www.edibon.com/products/catalogues/en/units/electronics/industrial/SERIN-CA.pdf SERIN/CC. Computer Controlled Industrial Servosystems Trainer (for DC motors) Always included in the supply: RTC. EDIBON Real Time Control System Control Interface Box Direct Current Motor and Encoder Module 1 Teaching Technique used 2 Software for: 3 Cables and Accessories - Computer Control - Data Acquisition - Data Management 4 Manuals Unit: SERIN/CC. Industrial Servosystems Trainer (for DC motors) SPECIFICATIONS SUMMARY Items supplied as standard SERIN/CC Unit: It is formed by a Control Interface Box and a Direct Current Motor and Encoder Module. The Control Interface Box has a 4quadrants servo amplifier for DC motors that controls the motor speed, position and current of the motor. In order to do this control the feedback is done thanks to an encoder. The RS232 communication between the Control Interface Box and the computer (PC) provides the possibility of commanding the motor from the PC and to visualize the most important signals of the motor. The 4-quadrant servo amplifier controls the motor operation and the braking operation in both rotation directions clockwise and counterclockwise. Velocity, Position and Torque Control. It allows predefined moves and programming. Control Interface Box: Front panel:Diagram in the front panel with similar distribution that the elements in the real unit. 7 Digital outputs: They have led’s that indicate if the outputs are active or not. 13 Digital inputs: 7 user definable digital inputs for process control,1 digital input (trigger signal), 3 digital inputs: reference, left limit and right limit, 2 digital inputs power stage and stop. 2 Analog inputs with voltages in the range of 0-5V. 2 Potentiometers to select the value of the analog inputs (0-5 V DC). Ignition Switch. Back panel: Voltage supply that feeds the unit with 220 V of alternating current. Motor power supply: it is a 24 V DC motor power supply. Connection plug to connect the Control Interface with the PC by the RS-232 port, in order to allow the software to manage the motor. Connection with the motor Feedback, it allows the encoder to manage the motor. Direct Current Motor and Encoder Module: DC Motor, 90W, position, speed and current are controlled by the Control Interface. Digital encoder, 500 pulses per revolution, with RS232 communication port. 2 Power supply wires. 2 Communication RS232 wires. 2 SERIN/CC/CCSOF.Computer Control+Data Acquisition+Data Management Software: Registration and visualization of signals in an automatic and simultaneously way. Flexible, open and multicontrol software. Management, processing, comparison and storage of data. Comparative analysis of the obtained data, after to the process and modification of the conditions during the process. 3 Cables and Accessories, for normal operation. 4 Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =Unit: 490 x 330 x 310 mm. Weight: 40 Kg. Motor+Esconder Module:300x300x120 mm. Weight: 5Kg. 1 PRACTICAL POSSIBILITIES 1.- Autotuning. 2.- Manual tuning of the position regulator. 3.- Motion commands in MPBUS RS232 mode. 4.- Signals Graph, Transient Analysis. 5.- Batch Commands. 6.- User´s parameters, Position Val., velocity Val., Acceleration Val. 7.- Digital inputs and outputs in I/O mode. 8.- Load and braking simulation. 9.- Searching reference. 10.- Input/Output functions. 11.- State commands and Exception. 12.- Velocity, Position and Torque control. More information in: www.edibon.com/products/catalogues/en/units/electronics/industrial/SERIN-CC.pdf Page 27 www.edibon.com 2.6- Industrial Electronics 2.- Electronics 3 (continuation) SERIN/CCB. Servosystems Trainer (DC motors) SPECIFICATIONS SUMMARY “SERIN/CCB” is an unit whose goal is studing low power servo systems. It is a low power DC motor speed control trainer that has a breakdown simulator. This trainer is a basic version of the Advanced and Computerised “SERIN/CC” Trainer, being advisable for an introductory study of closed and open loop control systems. The trainer includes: Base Unit: Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. Electromechanic unit. Tachometric adaptor. Generation and control of set point. Ramp generator, as well as of sinusoidal, triangular and square wave generator. PWM modulator. Open loop control. Close loop control: Proportional Control (P). Integrative Proportional Control (PI). Proportional derivative Control (PD). Proportional Integrative derivative (PID). Current limiter. Turn inversion control. Stop/starting control. Power stage and excitation of the power stage. Brake control. Fault simulator that allows the entries of a considerable amount of disfunctions in order to the students diagnose its nature and find out the components that cause them. Possibility to make entries of disfunctions in only one or in some circuits. Direct current motor (DC) and tachometric generator. Computer Control Software. Cables and accessories, necessary for its correct operation. Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =400 x 330 x 310 mm. Weight: 10 Kg. More information in: www.edibon.com/products/ catalogues/en/units/electronics/industrial/ SERIN-CCB.pdf PRACTICAL POSSIBILITIES Some Practical Possibilities of the Unit: 1.- Open loop control response. 2.- Demonstration of a stopping ramp functioning. 3.- F unctioning of a PWM modulator and the response of the system. 4.- Closed loop or feedback control through a Proportional controller (P). 5.- Closed loop or feedback control through a Derivative controller (I). 6.- Closed loop or feedback control through a ProportionalIntegral controller (PI). 7.- Closed loop or feedback control through a ProportionalDerivative controller (PD). 8.- A chievement of an over damped system using a closed loop system. 9.- Achievement of a critically damped system using a closed loop PID. 10.- Instability, a characteristic of closed loop system. 11.- Stabilisation of an unstable system. 12.- Fault simulation: Type fault including on the unit: Fault 1: The absolute value of the feedback signal from the tachogenerator is not calculated for its subtraction from the reference, thus, for one of the turning senses, the error is wrong. Fault 2: The value of the Proportional constant of the PID is divided by ten with the user unable to detect it but its effect. Fault 3: The value of the Integral constant of the PID is divided by ten with the user unable to detect it but its effect. Fault 4: The value of the Derivative constant of the PID is divided by ten with the user unable to detect it but its effect. Fault 5: The signal from the tachogenerator is modified, making the PID control to believe that the speed is ten times lower to the real one. None of these faults are exclusive, being possible to combine them. SERIN/CAB. Servosystems Trainer (AC motors) SERIN/CACC. Computer Controlled Industrial Servosystems Trainer (for AC and DC motors) Page 28 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: Laboratory structure 1 Common Electrical Machines Base Units: EME/M. Electrical Machines Unit (Intermediate option) (Advanced option) (Basic option) 6 Transformers: 2 Measurement Units Other Network Analyzers: -EALD. With Computer Data Acquisition + Oscilloscope (PC). -EALDG.With Computer Data Acquisition + Oscilloscope (PC)+ Oscilloscope Display. Digital Multimeter EAL. Network Analyzer Unit ETT. Three and Single Phase Transformers Unit 11 MUAD. Power Data Acquisition System -EAM-VA. Analog Measurement Unit -MUAD. Power Data Acquisition System Teaching Technique used 3 Loads: RCL3R. Resistive, Inductive and Capacitive Loads Module EME/B. Electrical Machines Unit 7 DC Motor Speed Control - VVCC/M. DC Motor Speed Controller VVCC. DC Motors Speed Controller Electric Power Interface Box (EPIB) Individual elements: -IND. Inductance. or -CON. Box of condensers. -REV. Variable resistance. -REF. Fixed resistance. Individual elements: -AUTR. Variable Autotransformer. -TRANS. Single-phase transformer. or -TRANS/3.Three-phase transformer. or Data Acquisition Board (DAB) with no other elements 8 AC Motor Speed Control Data Acquisition Software(MUAD/SOF) VVCA. AC Motors Speed Controller or 4 Motors: 12 CAI. Teaching Technique used (intermediate option) with no other elements 9 PLC PLC-PI. PLC Module for the Control of Industrial Processes Software - VVCA/M. AC Motor Speed Controller Individual elements: - VVCA/B. AC motors speed controller, Computer Aided Instruction Software System INS/SOF. Instructor (intermediate option) Individual elements: - VVCC/B. DC motors speed controller, Individual elements: or - EDIBON FP-X-CPU. PLC, + with no other elements. 5 Brakes: FRE-FE. Electronic Brake Other brakes: -DI-FRE. Pendular Dynamo Brake. -FREND. Dynamo Brake. or -FRENP. Magnetic Powder Brake. -FREPR. Prony Brake. -FRECP. Eddy Current Brake EMT../SOF. 10 Tachogenerator Student/Motor Software TECNEL/T. Tachogenerator or - TECNEL/TM. Hand Tachometer Complete configuration Main units: 1 Common Electrical Machines Base Units. 2 Measurement Units. 3 Loads. 4 Motors. 5 Brakes. 11 12 Complementary possibilities: MUAD. Power Data Acquisition System. CAI. Computer Aided Instruction Software System. * MINIMUM CONFIGURATION: 1 + 2 Complementary elements: 6 Transformers. 7 DC Motor Speed Control. 8 AC Motor Speed Control. 9 PLC (Programmable Logic Contoller). 10 Tachogenerator. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 57 www.edibon.com 4.- Electricity EME. Electrical Machines Unit 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) (continuation) Common Electrical Machines Base Units: EDIBON presents three alternatives with increasing complexity and practical possibilities. - EME. Electrical Machines Unit. It is a compact unit including the main electrical functions. It is EDIBON’s most advanced option. - EME/M. Electrical Machines Unit (intermediate option). Students can get a good grasp on the subject. - EME/B. Electrical Machines Unit (basic option). It includes the most basic functions. EME. Electrical Machines Unit (advanced option) SPECIFICATIONS SUMMARY The Electrical Machines Unit (EME) is a compact and robust box for the study of the main electrical functions. In its front side, you find standard electrical functions, divided in sections, for a better visualization of the different applications. In EME, you have all the main panels you need for analyzing an electrical machine, as measuring devices, supply systems, management systems, protection systems, synchronism and rectification systems, etc. This unit is prepared for working to a maximum power of 1 KW and all the components are located within a compact box. Metallic box. 4.- Electricity Diagram in the front panel. Different modules included in the EME unit: -Connection terminals module: Connection terminals of three-phase: R, S and T and supply neutral with the corresponding signaling lamps which indicate the voltage. There are 4 terminals in each phase. Signaling lamp which will light up when the threephase sequence in correct. This module also has a signaling lamp and fuse, corresponding to the internal supply of the unit. -Operation module: 3 Running switches. 3 Stop switches. 3 Three-pole contactors, power A, B and C, with control circuit in alternating current. Each contactor has 2 auxiliary terminals (NC) and 3 auxiliary terminals (NO). 3 Lamps that will light when the contactors are started. 2 Timing realys. Indicating lamps. -Protection module: Thermal Magnetic Circuit Breaker. Thermal relay. 3 Power contacts. 2 auxiliary contacts (NO and NC). Signaling lamp. -Synchronizing and rectification module: 3 lamps, as well as the inlet terminals for the threephases with signaling for indicating its correct sequence. One phase bridge rectifier, with 2 fuses with their corresponding fusion lamps. -Contactors module: 3 Power takes, and the selected position closes the corresponding contact in the three phases. -Possibility of assemblies of control circuits with delay. * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 450 x 470 mm. approx. Weight: 50 Kg. approx. More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf Page 58 PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/2/3/4/5/15) 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristic curve. 5.- Dynamo characteristic regulation curve. 6.- Speed variation, inversion and stop of D.C. motor with independent excitation. 7.- Speed-armature current characteristic curves in a D.C. motor with shunt or independent excitation. 8.- Torque-current characteristic curve in a D.C. motor with shunt or independent excitation. 9.- Torque-speed characteristic curve in a D.C. motor with shunt or independent excitation. 10.- Speed-excitation current characteristic curves in a D.C. motor with independent or shunt excitation. Operation in constant power. 11.- Speed control at constant torque. 12.- Series D.C. motor: starting, speed variation, inversion and braking. 13.- Speed-intensity characteristic curve in a D.C. motor with series excitation. 14.- Torque-current characteristic curve in a D.C. motor with series excitation. 15.- The D.C. motor with series excitation as universal motor. The Synchronous Machine (with motor EMT 6) 16.- Starting, voltage and frequency regulation in a three-phase alternator. 17.- Net coupling of a three-phase alternator. 18.- Characteristic curve of an alternator without load. 19.- Characteristic curve of an alternator in short circuit. 20.- Characteristic curve of an alternator with load. 21.- Synchronous motor starting. The Asynchronous Machine (with motors EMT 7/ 8/ 9/ 10/ 11/ 16/ 17). 22.- Morley diagrams. 23.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 24.- Test without load of an asynchronous motor with rotor in short circuit. 25.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 26.- Starting of a three-phase asynchronous motor with the wound rotor. 27.- Test without load of a three-phase asynchronous motor with the wound rotor. 28.- Test with load of a three-phase asynchronous motor with wound rotor. 29.- Starting and turn sense inversion of a single-phase motor with capacitor. 30.- Test without load of a single-phase asynchronous motor. 31.- Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.- The Universal motor with D.C. supply. 33.- Speed-current characteristic of an Universal motor with D.C. supply. 34.- Torque-intensity characteristic in the D.C. Universal motor. 35.- The universal motor eith A.C. supply. The Repulsion motor (with motor EMT 14) 36.- Starting and inversion of a single-phase repulsion motor. 37.- Test of a single-phase repulsion motor without load. 38.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor (with motor EMT 18) 39.- Brushless motor starting. 40.- Speed control and change of the turn sense. The Dahlander motor (with motor EMT 9) 41.- Dahlander motor starting. 42.- Different working speeds. 43.- Changing the different speeds of Dahlander motor while working. The Stepper motor (with motor EMT 19) 44.- Stepper motor starting. 45.- Steps control. 46.- Rotation sense change. The Reluctance motor ( with motor EMT21) 47.- Star connection of the reluctance motor. 48.- Delta connection of the reluctance motor. 49.- Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 1 (continuation) Common Electrical Machines Base Units: (continuation) EME/M. Electrical Machines Unit (intermediate option) More information in: www.edibon.com/products/ catalogues/en/units/electricity/machines/LIMEL.pdf The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- The dynamo characteristic curve without load. 3.- Dynamos with series and shunt excitation. 4.- Dynamo external characteristics curve. 5.- Characteristic regulation curve of a dynamo. 6.- Speed control at constant torque. 7.- Series D.C. motor: starting, speed variation, inversion and braking. The Synchronous Machine: 8.- Starting, voltage and frequency regulation in a three-phase alternator. 9.- Characteristic curve of an alternator without load. 10.- Characteristic curve of an alternator in short circuit. 11.- Characteristic curve of an alternator with load. 12.- Synchronous motor starting. The Asynchronous Machine: 13.- Morley diagrams. 14.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 15.- Test without load of an asynchronous motor with rotor in short circuit. 16.- Test with load of a three-phase asynchronous motor with rotor in short circuit. 17.- Starting and turn sense inversion of a single-phase motor with capacitor. 18.- Test without load of a single-phase motor. 19.- Test in load of the single-phase motor. The Universal motor: 20.- The universal motor with D.C. supply. 21.- Speed-current characteristic of an Universal motor with D.C. supply. 22.- Torque-intensity characteristic in the D.C. Universal motor. 23.- The Universal motor eith A.C. supply. The Repulsion motor: 24.- Starting and inversion of a single-phase repulsion motor. 25.- Test of a single-phase repulsion motor without load. 26.- Test of a single-phase asynchronous repulsion motor in A.C. The Brushless motor: 27.- Brushless motor starting. 28.- Speed control and change of the turn sense. The Dahlander motor: 29.- Dahlander motor starting. 30.- Different working speeds. The Reluctance motor: 31.- Star connection of the reluctance motor. 32.- Delta connection of the reluctance motor. 33.- Revolution sense and inversion of rotation. EME/B. Electrical Machines Unit (basic option) SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. DC supply 200 V dc with fuses. Connection Key. Emergency stop push button. Two push buttons (1NO + 1NC). * Minimum recommended measurement units: 2 Digital multimeters. Recommended measurement units: EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 300 x 180 x 120 mm. approx. Weight: 5 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 59 PRACTICAL POSSIBILITIES The D.C.Machine: 1.- Preparation, regulation and inversion in a dynamo with independent excitation. 2.- Dynamos with series and shunt excitation. 3.- Speed control at constant torque. 4.- Series D.C. Motor: starting, speed variation, inversion and braking. The Asynchronous Machine: 5.- Starting process of a three-phase asynchronous motor with rotor in short circuit. 6.- Test without load of an asynchronous motor with rotor in short circuit. The Universal motor: 7.- The Universal motor with D.C. supply. www.edibon.com 4.- Electricity PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Metallic box. Diagram in the front panel. Thermal Magnetic Circuit Breaker. Two double switches (1 NO + 1 NC in each one) Push Button (1 NC + 1 NO). Three contactors with 2 NO and 1 NC. DC supply 200 V dc with fuses. Connection Key Emergency stop push button. * Minimum recommended measurement units: (see Section “2”) 2 Digital multimeters. Recommended measurement units: (see Section “2”) EAL. Network Analyzer Unit. Electrical supply: Three-phase with neutral and ground, 380V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 25 Kg. approx. 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) (continuation) Measurement Units The measurement units let us extract information from the experimental unit (EME), thus allowing further process of the data. We can get values of currents, voltages, resistance, etc. for further analysis. MULT. Digital Multimeter SPECIFICATIONS SUMMARY Digital multimeter. Voltage and current meter. Resistances and capacitors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAL. Network Analyzer Unit 4.- Electricity SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals, for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EALD. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC). SPECIFICATIONS SUMMARY This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Metallic box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ±0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 60 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 2 (continuation) Measurement Units (continuation) EALDG. Network Analyzer Unit, with Computer Data Acquisition + Oscilloscope (PC) + Oscilloscope Display SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES 4.- Electricity This unit shows the main electric parameters on the electric network through the interface and an parameter selection. Steel box. Diagram in the front panel. 3 current inputs, for series intensity. 3 voltage terminals for each phase measure (R,S,T) and another one for the neutral connection. Control and visualization digital display and oscilloscope display. Voltage: Range 20 - 500 Vrms. Prec.: ± 0.5%. Phase to phase - Phase to neutral. Current: Range 0.02 - 5 Arms. Prec.: ± 0.5%. Frequency: Range 48 to 62 Hz. ± 0.1Hz. Power: Active, Reactive and Apparent. Range 0.01 to 9900 kW. Prec.: ±1%. Power Factor: Power Factor for each phase and average. Range -0.1 to + 0.1. Prec.: ±1%. Operating temperature 0 to +50°C. Connection RS232 to computer (PC). Data Acquisition Software. Power supply: 220 V. - 110 V., single -phase + ground. Dimensions: 300 x 180 x 120 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EAM-VA. Analog Measurement Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit allows to analyze the different voltages and currents involved in a circuit through a simple frontal panel that includes analog measurement instruments. Metallic box. 4 Voltmeters. - A.C. Measuring Instruments with moving iron. - Voltmeter with measuring range from 0 to 500Vac. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Ammeters. - A.C. Measuring Instruments with moving iron. - Ammeter with measuring range of 0 to 5A. - Horizontal scale with precision grade of 1.5 (following norm BS89/IEC51). 2 Analog inputs for each meter. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf MUAD. Power Data Acquisiton System. (see page 68) Page 61 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) Loads: RLC3R. Resistive, Inductive and Capacitive Loads Module 3 SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES When you brake an electrical machine, the electrical energy has to be dissipated. Loads provide this function, the dissipation of energy. Depending on the experiment, the dissipating load has to be resistive, inductive or capacitive. EDIBON recommends having the three kinds, if a good understanding on the subject is pursued. Our Resistive, Capacitive and Inductive Loads Module (RCL3R) offers: Single and Three-phase resistances. Single and Three-phase inductances. Single and Three-phase capacitors. Metallic box. Diagram in the front panel. Variable resistive loads: 3 x [ 150 W (500 W) ]. Fixed resistive loads: 3 x [ 150 W (500 W) + 150 W (500 W) ]. Inductive loads: 3 x [ 0, 33, 78, 140, 193, 236 mH ].(230V /2 A) Capacitive loads: 3 x [ 4 x 7 mF ]. (400V) Dimensions: 490 x 450 x 470 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 4.- Electricity Individual Elements IND CON PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY When a simpler and cheaper option is preferred when studying the use of loads in electrical machines, EDIBON gives the choice of acquiring single components. They are offered as single independent components to be mounted by the student. -IND. Inductance: From 33 to 236 mH, or similar. -CON. Box of Condensers: 7µF or similar. -REV. Variable Resistance: 0-150Ù (500W), or similar. -REF. Fixed Resistance : 150Ù (500W), or similar. REV More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf REF 4 Motors EDIBON has a wide range of electric motors. The motors supplied include connectors, couplings, standard motor support, etc. SPECIFICATIONS SUMMARY EMT2 EMT3 EMT1 EMT5 EMT4 EMT6 EMT8 EMT7 EMT9 EMT11 EMT12 EMT10 EMT15 EMT16 EMT14 EMT19 EMT17 EMT20 Available Motors EMT1. D.C. Independent excitation motor-generator. EMT2. D.C. Series excitation motor-generator. EMT3. D.C. Shunt excitation motor-generator. EMT4. D.C. Compound excitation motor-generator. EMT5. D . C . S h u n t - s e r i e s compound excitation motor. EMT6. A . C . S y n c h r o n o u s alternator motor. EMT7. Asynchronous three-phase motor of squirrel cage. EMT8. Asynchronous three-phase motor with wound rotor. EMT9. Dahlander three-phase (two-speeds). EMT10. Asynchronouts three-phase motor of two independent speeds. EMT11. Asynchronous single-phase motor with starting capacitor. EMT12. Universal motor (singlephase). EMT14. Repulsion motor, singlephase with short-circuited brushes. EMT15. D.C. Permanent magnet motor. EMT16. Asynchronous single-phase motor with starting and running capacitor. EMT17. Three-phase motor of squirel c a g e w i t h “ Y ” connection. EMT18. D.C. Brushless motor. EMT19. Stepper motor. EMT20. Asynchronous single-phase motor with split phase. EMT21. Three-phase Reluctance motor. EMT22. Single-phase Shaded Pole motor. PRACTICAL POSSIBILITIES The D.C.Machine (with motors EMT 1/ 2/ 3/4/5/15) 1.-Preparation,regulationandinversionin adynamowithindependentexcitation. 2.-Thedynamocharacteristiccurvewithout load. 3.-Dynamos with series and shunt excitation. 4.-Dynamoexternalcharacteristiccurve. 5.-Dynamo characteristic regulation curve. 6.-Speed variation, inversion and stop of D.C. motor with independent excitation. 7.-Speed-armature current characteristic curve in a D.C. motor with shunt or independentexcitation. 8.-Torque-current characteristic curve in a D.C. Motor with shunt or independentexcitation. 9.-Torque-speed characteristic curve in a D.C. Motor with shunt or independent excitation. 10.-Speed-excitation current characteristic curve in a D.C. Motor with independent or shunt excitation. Operation in constantpower. 11.-Speedcontrolatconstanttorque. 12.-Series D.C. Motor: starting, speed variation,inversionandbraking. 13.-Speed-intensity characteristic curve inaD.C.Motorwithseriesexcitation. 14.-Torque-current characteristic curve inaD.C.Motorwithseriesexcitation. 15.-The D.C. Motor with series excitation asuniversalmotor. The Synchronous Machine (with motor EMT6) 16.-Starting, voltage and frequency regulation in a three-phase alternator. 17.-Net coupling of a three-phase alternator. 18.-Characteristic curve of an alternator withoutload. 19.-Characteristic curve of an alternator inshortcircuit. 20.-Characteristic curve of an alternator withload. 21.-Synchronousmotorstarting. The asynchronous Machine (with motors EMT7/8/9/10/11/16/17) 22.-Morleydiagrams. 23.-Starting process of a three-phase asynchronous motor with rotor in shortcircuit. 24.-Test without load of an asynchronous motorwithrotorinshortcircuit. More information in: 25.-Test with load of a three-phase www.edibon.com/products/catalogues/ asynchronous motor with rotor in en/units/electricity/machines/ shortcircuit. LIMEL.pdf Page 62 26.-Starting of a three-phase asynchronous motor with the woundrotor. 27.-Test without load of a three-phase asynchronous motor with the woundrotor. 28.-Test with load of a three-phase asynchronous motor with wound rotor. 29.-Starting and turn sense inversion of a single-phase motor with capacitor. 30.-Test without load of a single-phase motor. 31.-Test in load of the single-phase motor. The Universal motor (with motor EMT 12) 32.-The universal motor with D.C. Supply. 33.-Speed-current characteristic of an UniversalmotorwithD.C.Supply. 34.-Torque-intensity characteristic in theD.C.Universalmotor. 35.-The universal motor eith A.C. Supply. The repulsion motor (with motor EMT 14) 36.-Starting and inversion of a singlephaserepulsionmotor. 37.-Test of a single-phase repulsion withoutload. 3 8 . -Te s t o f a s i n g l e - p h a s e asynchronous repulsion motor withA.C. The Brushless motor (with motor EMT 18) 39.-Brushlessmotorstarting. 40.-Speed control and change of the turnsense. The Dahlander motor (with motor EMT 9) 41.-Dahlandermotorstarting. 42.-Differentworkingspeeds. 43.-Changing the different speeds of Dahlandermotorwhileworking. TheSteppermotor(withmotorEMT19) 44.-Steppermotorstarting. 45.-Stepscontrol. 46.-Rotationsensechange. The Reluctance motor (with motor EMT21) 47.-Star connection of the reluctance motor. 48.-Delta connection of the reluctance motor. 49.-Revolution sense and inversion of rotation. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 5 (continuation) Brakes The importance of Brakes comes when we want to adjust the motor speed, measure the torque given, or stop the motor. FRE-FE. Electronic Brake SPECIFICATIONS SUMMARY This unit is based in two elements: 1.- Module -metallic box: Power supply:1 phase, 200-240V. Rated output capacity:0.75 KW. Output frequency range: 0.2 to 400 Hz. Display to visualize voltage (V), Current (A), and Frequency (Hz). Brake resistance included. Torquemeter. R.p.m. Meter. Connectors. 2.- Braking motor mounted on a bench-support. Connection wire between elements “1” and “2”. Electrical supply: 220V a.c. - 110V a.c., single-phase + ground. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf DI-FRE. Pendular Dynamo Brake SPECIFICATIONS SUMMARY 4.- Electricity Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Torque measured with lever and weights, by combining the mechanical torque and electrical torque. Security connectors. Bench-support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREND. Dynamo Brake SPECIFICATIONS SUMMARY Power: 250-300W. V.Excitation: 190 V.D.C. I.Excitation nominal: 0.3A. V.Armature: 200 V.D.C. I.Armature nominal: 1.5A. Connectors. Bench - support. Electrical supply: 200 Vdc. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRENP. Magnetic Powder Brake SPECIFICATIONS SUMMARY The unit consists of a magnetic powder brake, a control module an a tachometer for the speed measurement. The control module allows setting the nominal torque of the brake through a potentiometer. It has two terminals to measure a voltage in direct proportion to the current supplied to the brake, therefore, to the exerted torque. The unit has a tachometer connected to its axis. The unit also includes a fuse and a thermal relay to avoid eventual damages. Max. power: 400 W, limited at 220W. Voltage: 24 Vac. Max. torque: 5 Nm. Max. R.P.M.: 3000. It is equipped with temperature probe to stop the braking action. Electrical supply: 220 Vac. - 110 Vac. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FREPR. Prony Brake SPECIFICATIONS SUMMARY Prony brake with resistant ribbon. Mechanical braking action and dynamometer. Max. Power: 500 W. Max. Torque: 4Nm. Max. R.P.M.: 3000. Max. Time: 30 seconds. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf FRECP. Eddy Current Brake SPECIFICATIONS SUMMARY Max. Power: 500 W. Voltage: 120 Vdc. Max. Torque: 3Nm. Max. R.P. M.: 3000. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 63 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: (continuation) (continuation) 6 Transformers 4.- Electricity ETT. Three-phase and Single-phase Transformers Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Metallic box. Diagram in the front panel. Single-phase transformer: Nominal power: 500 VA. Transformation ratio: 400 / 230 V. Inlets: 400 V and 230 V (in the primary). Number of secondary coils: 2. Output voltage in the secondary: 115 (each one). Maximum current in the primary: 1.5 A (for each voltage of 400 V). 3 A (for each voltage of 230 V). Three-phase transformer in pillars: Nominal power: 1000 VA. Transformation ratio: 380/3 x 127 V. Inlets: 220 V and 380 V (in the primary). Outlet voltage in the secondary: 3 x 127 V (each phase). Maximum current in the primary: 2 A (for a voltage of 380 V). 2 A (for a voltage of 220 V). Connection modes: Primary: Star, triangle / Secondary: Star, triangle, zigzag, six-phase and triple star. Electrical supply: For Single-phase transformer: 400-230 V / 50 Hz. or 60 Hz. For Three-phase transformer: 380-220 V / 50 Hz. or 60 Hz. Dimensions: 490 x 330 x 310 mm. approx. Weight: 40 Kg. approx. 1.- Measurement of the transformation Ratio. 2.- Rehearsal of a single-phase transformer in open circuit. 3.- Rehearsal of a single-phase transformer in short circuit. 4.- Rehearsal of a single-phase transformer in load. 5.- Rehearsal of a three-phase transformer in open circuit. 6.- Rehearsal of a three-phase transformer in short circuit. 7.- Autotransformer tests. 8.- Connection modes tests: Start/delta/Zig-Zag/6-phase/triple star. 9.- Transformer ratio variation tests. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TPPT. Three-phase Power Transformer Unit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The “TPPT” unit is formed by a steel box, which contains a three-phase power transformer. In the front panel of the box are located the terminals for both primary and secondary terminals for different power supply inputs and outputs. In the backside are located the fuses to protect the transformer. Diagram in the front panel. Power: 1000 VA. Module 1: Primary winding It includes a three-phase winding which can be connected externally in either star or triangle, each phase winding has a neutral terminal, a 146V a.c. intermediate terminal and 220V a.c. terminal. Module 2: Secondary winding It includes a three-phase winding which can be connected externally in either star of triangle. Each phase winding has a neutral terminal, a 127V a.c. intermediate terminal and a 220V a.c. terminal. This unit can be used to make 6 different a.c. connection types: -Star (380V). - Triangle (380V). -Triangle (220V). - Triangle (380V). -Star (380V). - Star (220V). -Triangle (220V). - Star (220V). -Star (380V). - Triangle (127V). -Triangle (220V). - Triangle (127V). Electrical supply: 380-220 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf EMPTA. Auxiliary Transformer and Protection Module SPECIFICATIONS SUMMARY Metallic Box. Diagram in the front panel. Input and output connectors. Thermal magnetic unit 16 A ., 2 poles. Differential 25 A., 30 mV., 230 V. Reversible auto-transformer 125-220 (1000 VA). Conversion from 127V. 60Hz to 220V. 50Hz. Conversion from 220V. 50Hz to 127V. 60Hz. Differential electrical protection. Thermal magnetic protection. Required services: Input: 220V. 50Hz or 127V. 60Hz. Electrical supply: 220 V a.c. - 127 V a.c. Dimensions: 300 x 120 x 190 mm. approx. Net weight: 3Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: - AUTR. - TRANS. SPECIFICATIONS SUMMARY Variable Auto-transformer. Single-phase transformer. Input and output connectors. Single phase transformer, 400 Vac/230 Vac, 400 VA. Ground connector. - TRANS/3.Three-phase transformer. Input and output connectors. Three phase transformer, 400 Vac/230 Vac, 1000 VA TRANS More information in: www.edibon.com/products/catalogues/en/ TRANS/3 units/electricity/machines/LIMEL.pdf Page 64 PRACTICAL POSSIBILITIES 1.- Conversion from 127V/60Hz to 220V/ 50Hz. 2.- Conversion from 220V/50Hz to 127V/ 60Hz. 3.- Differential electrical protection. 4.- Thermal magnetic protection. 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 7 (continuation) DC Motor Speed Control VVCC. DC Motor Speed Controller This unit varies the speed of a DC motor for control applications. It works with any DC motor available. Metallic box. Front panel including: Excitation connection (2 connectors). Rotor connection (2 connectors). Tachodynamo connection (2 connectors). Parameters self adjustment (torque control and speed control): Motor torque regulator. Motor speed regulator. State leds indicators. START/STOP speed controller switch. ON/OFF main switch. Maximum power: 550W. Maximum torque: 2.6 Nm Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 10 Kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a certain frequency. 3.- Starting carrying out by defined ramp. 4.- Braking possibility until a certain speed and recovery. 4.- Electricity SPECIFICATIONS SUMMARY More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCC/M. DC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consists in a variable transformer followed by a rectifier bridge and an anti-ripple capacitor with a resistor to get discharged. Metallic box. Regulated voltage output up to ~320 Vdc. Maximum current output 2 A. Front panel including: Connections: Positive, negative and ground connections. ON/OFF switch. The top side of the unit include a wheel to adjust the DC output voltage up to ~320 Vdc. Electrical supply: 220V a.c. - 110V ac., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elements: SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES -VVCC/B. DC motors speed controller, with no other elements. Maximum power: 550W. Maximum torque: 2.6 N.m. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 65 www.edibon.com 4.4- Electrical Machines LIMEL. Integrated Laboratory for Electrical Machines: 8 (continuation) (continuation) AC Motor Speed Control VVCA. AC Motor Speed Controller SPECIFICATIONS SUMMARY 4.- Electricity This is a unit for varying the speed of an AC motor for control applications. It works with any AC motor available. This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a direct current motor. It consists basically on a rectifying phase coupled to another inverter phase, with a capacitor in parallel between them. By varying the shooting frequency of the IGBT, we obtain an alternating output at a variable frequency which is applied to the asynchronous motor. Metallic box. Circuit diagram in front panel. It has a control panel in order to introduce the parameters of the motor that is going to be used and the output frequency. In addition, through it, we can carry out several programming. It also has a series of terminals where we connect the digital and analog inputs and the relay and transistor outputs. Maximum power: 750 W. Parameter self adjustment. Analog/digital parameter inlets through panel. Turn inversion while running. Analog parameter visualization. Voltage Input : Frequency set according to external command: up to 50Hz. Reversible operation using +/- signal: 0 to +/-10 V. PID control. Current input: Frequency set according to the analog input current command: up to 50 Hz. Reversible operation: 20 to 4mA. PID control. 5 Digital inputs that can be configured by the user. 1 outlet to alarm relay. 2 transistor internal outlets. Maximum load current: 50 mA. Leak current at OFF: 0.1 mA. Speed range: 130-2000 r.p.m. Besides the motor speed controller, all the indicators, connecting cables and additional components are included. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 600 x 600 x 150 mm. approx. Weight: 30 kg. approx. PRACTICAL POSSIBILITIES 1.- Motor parameters adjustment. 2.- Working at a frequency given by the panel. 3.- Working at a frequency given by an analog input (potentiometer). 4.- Turn inversion. 5.- Display of analog output. 6.- Digital inputs configuration. 7.- Outputs from alarm to relay. 8.- Outputs from alarm to transistor. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf VVCA/M. AC Motor Speed Controller (intermediate option) SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This unit consist in a simple AC motor speed controller. Metallic box. Output: 3 PH, 3.0 KVA, 220 V, 1-50 Hz., 8.0 A. Overload current thermal protection. ON/OFF switch. It has two blocks in the front panel: Speed control: Start/Stop switch. Speed control potenciometer. Connections to motor: Three-phase connection to AC motor. Ground connection. Electrical supply: 220 V a.c. - 110 V a.c., single-phase + ground. Dimensions: 300 x 120 x 190 mm. approx. Weight: 3 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Individual Elemenents: SPECIFICATIONS SUMMARY -VVCA/B. AC motors speed controller, with no other elements. Frequency from 0 to 60Hz. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf Page 66 PRACTICAL POSSIBILITIES 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: 9 (continuation) PLC (Programmable Logic Controller) The Programmable Logic Controller is a device designed for real time control of sequential processes in an industrial environment. In this case, EDIBON has developed this PLC module for controlling the Electrical Machines Unit “EME”. PLC-PI. PLC Module for the Control of Industrial Processes PLC-PI + PLC-SOF This module has been designed for the Control of Industrial Processes. The application has been developed to be used with any individual electric machine. PLC-PI. Unit: Metallic box. Circuit diagram in the front panel. Front panel: Digital inputs(X) and Digital outputs (Y) block: 16 Digital inputs. 14 Digital outputs. Analog inputs block: 16 Analog inputs. Analog outputs block: 4 Analog outputs. Touch screen. Back panel: Power supply connector. 2 A Fuse. RS-232 connector to PC. Inside: Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable. Panasonic PLC: High-speed scan of 0.32 msec. for a basic instruction. Program capacity of 32 Ksteps, with a sufficient comment area. Equipped with a USB communication port. High-speed counter. Multi-point PID control. Digital inputs/outputs and analog inputs/outputs Panasonic modules. RS232 Communication wire, to computer (PC). PLC-SOF. PLC Control Software: The software package is always included with the PLC-PI unit, since it is the necessary application to program the PLC-PI from the computer. Electrical supply single-phase, 220 V. - 110 V. Dimensions: 490 x 330 x 310 mm. approx. Weight: 30 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf PRACTICAL POSSIBILITIES 1.- Control of the particular unit process through the control interface box without the PC. 2.- PID control. 3.- Visualization of all the sensors values used in the particular unit process. 4.- Calibration of all sensors included in the particular unit process. 5.- Hand on of all the actuators involved in the particular unit process. 6.- Realization of different experiments, in automatic way, without having in front the particular unit. (This experiment can be decided previously). 7.- Simulation of outside actions, when there are not any hardware element present. 8.- PLC hardware general use and manipulation. 9.- PLC process application for the particular unit. 10.- PLC structure. 11.- P L C i n p u t s a n d o u t p u t s configuration. 12.- PLC configuration possibilities. 13.- PLC program languages. 14.- PLC different programming standard languages (ladder diagram (LD), structures text (ST), instructions list (IL), sequential function chart (SFC), function diagram (FBD). 15.- New configuration and development of new process. 16.- Hand on an established process. 17.- Visualization of results and comparisons with the particular unit process. 18.- Possibility if creating new process in relation with the particular unit process. 19.- PLC Programming exercises. 20.- O w n P L C a p p l i c a t i o n s i n accordance with teacher and student requirements. EDIBON FP-X/CPU. PLC, with no other elements SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Inputs: 8. Input Commons: 1. Output: 6. Output commons: 4. Execution time: 0.32µs. Data memory: 12,285. Bit memory: 4096. High Speed Counter. Interrupt: 8 input interrupt X0 to X7. Constant time interrupt (0.5ms to 30sec). Interrupt subroutine jump time: 10 micro sec . PID: PID algorithm (with auto tuning). I-PD algorithm (with auto tuning).10ms cycle to 100s cycle. Dimension (w, h, d): 60 x 90 x 79mm. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf 10 Tachogenerator TECNEL/T. Tachogenerator SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES The Tachogenerator, as a speed transducer, provides a means of converting the rotational speed into an analog voltage signal. Thus, it is mainly used for measuring the motor speed. The TECNEL/T is an automatic unit, that could be permanently connected to the main rotor. Output voltage gradient: 30 +/- 3% V /1000 r.p.m. Electrical supply: continuous d.c. output 0-100 V. Dimensions: 200 x 150 x 50 mm. approx. Weight: 1Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/LIMEL.pdf TECNEL/TM. Hand Tachometer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This is a hand optical tachogenerator. It cannot be attached to the motor, what implies that the measurements have to be taken manually. Page 67 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY 4.4- Electrical Machines (continuation) LIMEL. Integrated Laboratory for Electrical Machines: (continuation) Data Acquisition 11 MUAD. Power Data Acquisition System 3 4 “n” EME unit Electric power interface box (EPIB) Cable to computer (DAB) Connections points Data acquisition board 2 MUAD is the perfect link between the EME unit and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope. We easily connect the Electric Power Interface Box (EPIB) to the EME unit with the supplied cables (there are several connection points placed for it). The EPIB is connected to the PC through the Data Acquisition Board (DAB), and by using the Data Acquisition with Virtual Instrumentation Software, the student can get results from the undertaken experiment/practice, see them on the screen and work with them. Data acquisition software (MUAD/SOF) Cables to interface 1 Student post This MUAD System includes EPIB + DAB + MUAD/SOF: 4.- Electricity 1)Hardware : 1.1) EPIB. Electric power interface box ( dimensions: 300 x 120 x 180 mm. approx.): Interface that carries out the conditioning of the diverse signals that can be acquired in a process, for their later treatment and visualisation. Front panel separated in two: left-hand part for VOLTAGE sensors, and right-hand part for CURRENT Sensors. - 8 analog input channels. - Sampling range: 250 KSPS (Kilo samples per second). - 4 Tension sensors AC/DC, 400V. - 4 Current sensors. 1.2) DAB. Data acquisition board : PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI. Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KSPS (Kilo samples per second). Analog output: Number of channels=2. Resolution=16 bits, 1 in 65536. Digital Input/Output: Number channels=24inputs/outputs. Timing: Counter/timers=2. EPIB DAB 2) MUAD/SOF. Data acquisition software : Data Acquisition Software with Graphic Representation: Amicable graphical frame. Compatible with actual Windows operating systems. Configurable software allowing the representation of temporal evolution of different signals. Visualization of circuit tensions on the computer screen. Sampling rate up to 250 KSPS (Kilo samples per second) guaranteed. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf 12 Software CAI. Computer Aided Instruction Software System With no physical connection between motor and computer, this complete package consists on an Instructor Software (INS/SOF) totally integrated with the Student Software (EMT../SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. These, on the other hand, get a virtual instructor who helps them to deal with all the information on the subject of study. + Motor Instructor Software MUAD/SOF Student/Motor Software With the INS/SOF. Classroom Management Software Package (Instructor Software), the Teacher has a whole range of options, among them: - Organize Students by Classes and Groups. - Create easily new entries or delete them. - Create data bases with student information. - Analyze results and make statistical comparisons. - Print reports. - Develop own examinations. - Detect student’s progress and difficulties. ...and many other facilities. The Instructor Software is the same for all the motors, and working in network configuration, allows controlling all the students in the classroom. EMT../SOF. Computer Aided Instruction Software Packages (Student Software) Explains how to use the motor and run the experiments and what to do at any moment. Each motor has its own Student Software package. - The options are presented by pull-down menus and pop-up windows. - Each Software Package contains: Theory: that gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done, alongside the motors, showing how to complete the circuits and get the right information from them. Exams: set of questions presented to test the knowledge obtained. Available Student Software Packages: -EMT1/SOF. -EMT2/SOF. -EMT3/SOF. -EMT4/SOF. -EMT5/SOF. -EMT6 /SOF. -EMT7 /SOF. -EMT8 /SOF. -EMT9 /SOF. -EMT10/SOF. -EMT11/SOF. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. Asynchronous three-phase motor with wound rotor. Dahlander three-phase (two-speeds). Asynchronous three-phase motor with two independent speeds. Asynchronous single-phase motor with starting capacitor. -EMT12/SOF. -EMT14/SOF. -EMT15/SOF. -EMT16/SOF. -EMT17/SOF. -EMT18/SOF. -EMT19/SOF. -EMT20/SOF. -EMT21/SOF. -EMT22/SOF. Universal motor (single-phase). Repulsion motor, single-phase with short-circuited brushes. DC Permanent magnet motor. Asynchronous single-phase motor with starting and running capacitor. Three-phase motor of squirrel cage with “Y” connection. DC Brushless motor. Stepper motor. Asynchronous single-phase motor with split phase. Three-phase Reluctance motor. Single-phase Shaded Pole motor. More information in: www.edibon.com/products/catalogues/en/units/electricity/machines/LIMEL.pdf Page 68 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx. 4.4- Electrical Machines (continuation) ERP. Protection Relay Test: 4.- Electricity ERP-UB. Protection and Relay Test Unit SPECIFICATIONS SUMMARY This is a teaching unit which gives students theoretical and practical experience with several industrial relays. Unit designed for comprehensive investigations into the theory and practice of electrical power system protection. This unit is common for the relays modules type “ERP” and can use one or more relays. Anodized aluminium structure. Panels and main metallic elements in stainless steel. Floor-standing unit. It uses genuine industrial relays, not simulations, with full range of safety features incorporated throughout. Diagrams on the unit enable students to set up and perform practices and experiments with minimal supervision. Comprehensive controls, transformers, supplies and instrumentation. It includes desk space for users or students to work on, and mounting area for relays. It is supplied with relay support software. Selection of up-to-date numerical protection relays, specially adapted for educational use. (See available relays). Unit controls and instrumentations specifications: 0 to 10 A variable current supply.0 to 220 V variable voltage supply. 2 fault limiting resistors. Timed fault application circuit breaker. Configurable tapped transformer with delta or star secondary. Variable three-phase load star connected. Variable three-phase load delta connected. 2 sets of three-phase voltage transformers. 4 sets of threephase current transformers. Mains isolator. Test circuits: Configurable transformer test circuit. Relay test area. Transmission line model (5 x 50 km). Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 2500mm x 1000mm x 1800mm. Weight: 600 Kg. PRACTICAL POSSIBILITIES 1.- A wide range of practices and investigations into the performance and characteristics of a variety of different industrial relays. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-SFT. Overcurrent and Earth Fault Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of transformers, transmission lines and distribution schemes. Modern and robust enclosure (steel box) with carrying handles. Modern industrial over current and earth fault relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Three-phase earth and overcurrent: three independent stages, the first stage selectable from any of 12 IDMT curves, the remaining stages having a direct time characteristic (ANSI 50/51 and ANSI 50N/51N). Thermal overload protection (ANSI 49). High impedance restricted earth fault (ANSI 64N). Undercurrent (ANSI 37). Broken conductor detection (ANSI 46BC). Negative phase sequence overcurrent - two independent stages (ANSI 46). Selectable blocking. Circuit monitoring. Trend, fault and disturbance records. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 5%. Current: 1 A (A.C.). Frequency: 50 or 60 Hz.Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490mm x 400mm x 310mm. Weight: 10 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the characteristics and performance of an industrial over current and earth fault relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-SDND. Directional/Non Directional Overcurrent Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of generator and transformer schemes, overhead lines, underground cables and backup on high-voltage systems. Modern and robust enclosure (steel box) with carrying handles. Modern industrial directional/non directional overcurrent relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Three independent stages of directional/non-directional phase overcurrent (ANSI 50, ANSI 51, ANSI 67). Undercurrent (ANSI 37). Thermal overload protection (ANSI 49). Negative phase sequence overcurrent (ANSI 46). Overvoltage (ANSI 59). Undervoltage (ANSI 27). Directional/non-directional earth fault (ANSI 67N, ANSI 50N, ANSI 51N). Creating fault and disturbance records. Selectable blocking. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490mm x 400mm x 310mm. Weight: 15 Kg. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf Page 70 PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial directional/non directional overcurrent relay. 4.4- Electrical Machines (continuation) ERP. Protection Relay Test: (continuation) ERP-PDF. Differential Protection Relay Module SPECIFICATIONS SUMMARY For use with Protection and Relay Test Unit (ERP-UB) , to enable investigations into protection of transformers, autotransformers, generators and other apparatus with two windings. It demonstrates the characteristics of three-phase differential protection. Modern and robust enclosure (steel box) with carrying handles. Modern industrial differential protection relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Differential protection (ANSI 87). Thermal overload protection (ANSI 49). Definete time overcurrent protection (ANSI 50P, ANSI 50Q and ANSI 50N/G). Inverse time overcurrent protection (ANSI 51P, ANSI 51Q and ANSI 51N/G). Connection to the primary and secondary windings of the experimental is circuit via current transformers with ratio to suit the inputs of the relay. This provides an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 5%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial differential protection relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-MA. Feeder Management Relay Module PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial feeder management relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf ERP-PD. Distance Protection Relay Module SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of overhead transmission lines. Modern and robust enclosure (steel box) with carrying handles. Modern industrial distance protection relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: Full scheme phase and ground distance protection, up to five zones (ANSI 21G and ANSI 21P). Directional/non-directional earth fault (ANSI 50N, ANSI 51N, ANSI 67N). Directional/non-directional phase overcurrent (ANSI 50, ANSI 51, ANSI 67). Directional/nondirectional negative sequence overcurrent (ANSI 46, ANSI 67). Broken conductor. Thermal overload protection (ANSI 49). Creating fault and disturbance records. Blocking of any one protection element. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. PRACTICAL POSSIBILITIES 1.-A wide range of practices and investigations into the performance and characteristics of an industrial distance protection relay. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ERP.pdf Page 71 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY For use with the Protection and Relay Test Unit (ERP-UB), to enable investigations into protection and monitoring of overhead lines and underground cables. Modern and robust enclosure (steel box) with carrying handles. Modern industrial feeder management relay presented in an educational and teaching format. The connections are via safety sockets. The main functions: 4 independent stages of directional/non-directional overcurrent (ANSI 50, ANSI 51, ANSI 67). Directional/non-directional earth fault (ANSI 50N, ANSI 51N, ANSI 67N). Sensitive directional/nondirectional earth fault. Sensitive directional earth fault. Wattmetric earth fault (ANSI 32N). Restricted earth fault (ANSI 64N). Directional/non-directional negative sequence overcurrent (ANSI 46, ANSI 67). Under and overvoltage (ANSI 27, ANSI 59). Thermal overload protection (ANSI 49). Residual overvoltage (ANSI 59N). Under and over frequency. Negative sequence overvoltage (ANSI 47). Selectable blocking. Broken conductor. Creating fault and disturbance records. The connection to the experimental circuit is via current transformers with ratio to suit the inputs of the relay. It allows an effective demonstration of the effect of current and voltage transformer ratio, connection and rating on protective relays. Accuracy: +- 10%. Current: 1 A (A. C.). Frequency: 50 or 60 Hz. Operating time: typically 10 ms to 25 ms. Cables and accessories, for normal operation. Manuals: this unit is supplied with 8 manuals. Dimensions(approx.): 490x400x310 mm. Weight: 15 Kg. 4.5- Electrical Machines Kits EMT-KIT. Disassembly Machines Kit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This Disassembly Machines Kit “EMT-KIT” allows the student to construct, operate and make more than 50 The student can study and make theses machines assemblies: assemblies and 1.- Machines operating principles. practices of different electrical machines. We have designed EMT-KIT to introduce students to 2.- Electromagnetism introduction. electrical machines basic principles and a good 3.- Basic DC and AC generators. understanding of motors and generators operation. The student, using this Kit, will see clearly the machines 4.- DC shunt motor (with and without interpoles). components and how interconnecting them, both 5.- DC shunt motor faults. electrically and mechanically. The different machines have protected rotating parts, 6.- DC series motor (with and without interpoles). use low voltages, but the machines characteristics are compatible to their industrial models equivalents. Baseplate. Frame ring. Fixed and removable bearing housings. 4.- Electricity Shaft. Squirrel cage rotor. Wound stator. Centrifugal switch. Couplings. Hand crank. Interpoles. Armature poles and Hub. Armature, field and interpole coils. Compound field coils. Field poles. Brush holders. Brushes. Commutator/slip rings. Robust case for the elements. Necessary tools and elements for normal working operation. All machines that may be assembled use low voltage. Protected rotating parts. Operating at low power levels. 7.- DC compound motor (with and without interpoles). 8.- DC shunt generator (with and without interpoles). 9.- DC series generator (with and without interpoles). 10.- DC compound generator (with and without interpoles). 11.- DC separately excited generator (with and without interpoles). 12.- Single-phase AC series universal motor. 13.- Single-phase AC induction motor, squirrel cage (4 pole). 14.-Single-phase AC induction motor, squirrel cage (2 pole). 15.- Single-phase AC synchronous motor/generator (4 pole). 16.- Single-phase AC synchronous motor/generator (2 pole). 17.- Single-phase AC repulsion motor. 18.-Single-phase AC generator, rotating armature. Control switches and resistive and capacitive 19.- Single-phase AC generator, rotating field. elements included. 20.- AC brushless generator. Power supply system: The mains supply required is a 5-wire, 380/415V three-phase 50/60Hz power system with neutral and earth connections. The power supplies in the unit have overcurrent circuit breakers for equipment protection and differential protection for student safety, and have variable voltage outputs for DC, single-phase AC and threephase AC. This power supply has three-phase AC variable supply totally adjustable, singlephase AC variable supply totally adjustable 21.- Three-phase AC induction motor, squirrel cage (4 pole). 22.- Three-phase AC induction motor, squirrel cage (2 pole). 23.- Three-phase AC synchronous motor (2 pole). 24.- Three-phase AC synchronous generator ( 2 pole). 25.- Shaded pole induction motor. 26.- Split field series motor. 27.- Stepper motors. and DC power supply totally adjustable. This 28.- 4 pole induction motor faults. unit cover all possibilities motors 29.- Pole changing induction motor. requirements. Brake dynamo. 30.- Synchronous motor characteristics. Tacho-dynamo. 31.- Synchronisation. Mobile elements are protected, and electrical 32.- AC motors power factor correction. protections available. Manuals: This Kits is supplied with 8 manuals. More information in: www.edibon.com/products/ catalogues/en/units/electricity/machineskits/EMT-KIT.pdf Page 72 33.- DC motor dynamic braking. issue:01/11 ELECTRICAL MACHINES. "DISASSEMBLY" MODULE Ref: 0483 ITEM 1 1 / 3 REFERENCE EMT-KIT EMT-KIT/1 EMT-KIT/2 EMT-KIT/3 EMT-KIT/4 EMT-KIT/5 EMT-KIT/6 EMT-KIT/7 EMT-KIT/8 EMT-KIT/9 EMT-KIT/10 EMT-KIT/11 EMT-KIT/12 EMT-KIT/13 EMT-KIT/14 EMT-KIT/15 EMT-KIT/16 EMT-KIT/17 EMT-KIT/18 EMT-KIT/19 EMT-KIT/20 EMT-KIT/21 EMT-KIT/22 EMT-KIT/23 EMT-KIT/24 EMT-KIT/25 EMT-KIT/26 EMT-KIT/27 EMT-KIT/28 EMT-KIT/29 EMT-KIT/30 EMT-KIT/31 EMT-KIT/32 EMT-KIT/33 DESCRIPTION DISASSEMBLY MACHINES KIT, FOR STUDYING: MACHINES OPERATING PRINCIPLES ELECTROMAGNETISM INTRODUCTION BASIC DC AND AC GENERATORS DC SHUNT MOTOR (WITH AND WITHOUT INTERPOLES) DC SHUNT MOTOR FAULT DC SERIES MOTOR (WITH AND WITHOUT INTERPOLES) DC COMPOUND MOTOR (WITH AND WITHOUT INTERPOLES) DC SHUNT GENERATOR (WITH AND WITHOUT INTERPOLES) DC SERIES GENERATOR (WITH AND WITHOUT INTERPOLES) DC COMPOUND GENERATOR (WITH AND WITHOUT INTERPOLES) DC SEPARATELY EXCITED GENERATOR (WITH AND WITHOUT INTERPOLES) SINGLE-PHASE AC SERIES UNIVERSAL MOTOR SINGLE-PHASE AC INDUCTION MOTOR, SQUIRREL CAGE (4 POLE) SINGLE-PHASE AC INDUCTION MOTOR, SQUIRREL CAGE (2 POLE) SINGLE-PHASE AC SYNCHRONOUS MOTOR/GENERATOR (4 POLE) SINGLE-PHASE AC SYNCHRONOUS MOTOR/GENERATOR (2 POLE) SINGLE-PHASE AC REPULSION MOTOR SNGLE-PHASE AC GENERATOR, ROTATING ARMATURE SNGLE-PHASE AC GENERATOR, ROTATING FIELD AC BRUSHLESS GENERATOR THREE-PHASE AC INDUCTION MOTOR, SQUIRREL CAGE (4 POLE) THREE-PHASE AC INDUCTION MOTOR, SQUIRREL CAGE (2 POLE) THREE-PHASE AC SYNCHRONOUS MOTOR (2 POLE) THREE-PHASE AC SYNCHRONOUS GENERATOR (2 POLE) SHADED POLE INDUCTION MOTOR SPLIT FIELD SERIES MOTOR STEPPER MOTOR 4 POLE INDUCTION MOTOR FAULTS POLE CHANGING INDUCTION MOTOR SYNCHRONOUS MOTOR CHARACTERISTICS SYNCHRONISATION AC MOTORS POWER FACTOR CORRECTION DC MOTOR DYNAMIC BRAKING QTY. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ref: 0483 ITEM 2 / 3 REFERENCE DESCRIPTION QTY. 2 EMT-KIT/CAL COMPUTER AIDED LEARNING SOFTWARE FOR DISASSEMBLY MACHINES KIT (RESULTS CALCULATION AND ANALYSIS) 1 3 EMT-KIT/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF DISASSEMBLY MACHINES KIT 1 4 INS/SOF CLASSROOM MANAGEMENT SOFTWARE PACKAGE (TEACHER'S SOFTWARE) 1 5 MUAD ELECTRIC POWER DATA ACQUISITION SYSTEM,INCLUDED: ELECTRIC POWER INTERFACE BOX DATA ACQUISITION BOARD DATA ACQUISITION SOFTWARE 1 EPIB DAB MUAD/SOF 1 1 1 6 EALD NETWORK ANALYCER UNIT WITH COMPUTER DATA ACQUISITION + OSCILLOSCOPE (PC) 1 7 0483PARTS COMPONENTS AND SPARE PARTS 1 8 0483PA COMPLEMENTARY ITEM 1 9 0483IYPM INSTALLATION AND STARTING UP 1 10 0483CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 11 0483TD TEACHING TECHNIQUES "KNOW-HOW" 1 12 0483MANU DOCUMENTATION AND MANUALS 1 Ref: 0483 3 / 3 * Each Software Package contains the following parts: Theory, Exercises, Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 20 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation. - Installation of all units supplied. - Starting up for all units. - Training about the exercises to be done any unit. - Teacher training related with the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit . . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. Calibration manual. See Catalogues in next pages 4.5- Electrical Machines Kits EMT-KIT. Disassembly Machines Kit SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES This Disassembly Machines Kit “EMT-KIT” allows the student to construct, operate and make more than 50 The student can study and make theses machines assemblies: assemblies and 1.- Machines operating principles. practices of different electrical machines. We have designed EMT-KIT to introduce students to 2.- Electromagnetism introduction. electrical machines basic principles and a good 3.- Basic DC and AC generators. understanding of motors and generators operation. The student, using this Kit, will see clearly the machines 4.- DC shunt motor (with and without interpoles). components and how interconnecting them, both 5.- DC shunt motor faults. electrically and mechanically. The different machines have protected rotating parts, 6.- DC series motor (with and without interpoles). use low voltages, but the machines characteristics are compatible to their industrial models equivalents. Baseplate. Frame ring. Fixed and removable bearing housings. 4.- Electricity Shaft. Squirrel cage rotor. Wound stator. Centrifugal switch. Couplings. Hand crank. Interpoles. Armature poles and Hub. Armature, field and interpole coils. Compound field coils. Field poles. Brush holders. Brushes. Commutator/slip rings. Robust case for the elements. Necessary tools and elements for normal working operation. All machines that may be assembled use low voltage. Protected rotating parts. Operating at low power levels. 7.- DC compound motor (with and without interpoles). 8.- DC shunt generator (with and without interpoles). 9.- DC series generator (with and without interpoles). 10.- DC compound generator (with and without interpoles). 11.- DC separately excited generator (with and without interpoles). 12.- Single-phase AC series universal motor. 13.- Single-phase AC induction motor, squirrel cage (4 pole). 14.-Single-phase AC induction motor, squirrel cage (2 pole). 15.- Single-phase AC synchronous motor/generator (4 pole). 16.- Single-phase AC synchronous motor/generator (2 pole). 17.- Single-phase AC repulsion motor. 18.-Single-phase AC generator, rotating armature. Control switches and resistive and capacitive 19.- Single-phase AC generator, rotating field. elements included. 20.- AC brushless generator. Power supply system: The mains supply required is a 5-wire, 380/415V three-phase 50/60Hz power system with neutral and earth connections. The power supplies in the unit have overcurrent circuit breakers for equipment protection and differential protection for student safety, and have variable voltage outputs for DC, single-phase AC and threephase AC. This power supply has three-phase AC variable supply totally adjustable, singlephase AC variable supply totally adjustable 21.- Three-phase AC induction motor, squirrel cage (4 pole). 22.- Three-phase AC induction motor, squirrel cage (2 pole). 23.- Three-phase AC synchronous motor (2 pole). 24.- Three-phase AC synchronous generator ( 2 pole). 25.- Shaded pole induction motor. 26.- Split field series motor. 27.- Stepper motors. and DC power supply totally adjustable. This 28.- 4 pole induction motor faults. unit cover all possibilities motors 29.- Pole changing induction motor. requirements. Brake dynamo. 30.- Synchronous motor characteristics. Tacho-dynamo. 31.- Synchronisation. Mobile elements are protected, and electrical 32.- AC motors power factor correction. protections available. Manuals: This Kits is supplied with 8 manuals. More information in: www.edibon.com/products/ catalogues/en/units/electricity/machineskits/EMT-KIT.pdf Page 72 33.- DC motor dynamic braking. issue:01/11 CUT AWAY MOTORS. BASIC MODULE Ref: 0490 1 / 1 ITEM 1 REFERENCE EMT-S EMT-5S EMT-6S EMT-7S EMT-11S EMT-12S EMT-16S DESCRIPTION QTY. CUT AWAY MOTORS, FORMED BY: DC SHUNT-SERIES-COMPOUND MOTOR SYNCHRONOUS ALTERNATOR MOTOR THREE-PHASE MOTOR SQUIRREL CAGE SINGLE-PHASE EXCITATION CUT AWAY MOTOR OF CONDENSER UNIVERSAL SINGLE-PHASE MOTOR SINGLE-PHASE MOTOR WITH STARTING CONDENSER & WORKING 1 1 1 1 1 1 1 2 0470PARTS COMPONENTS AND SPARE PARTS 1 3 0470PA COMPLEMENTARY ITEM 1 4 0470IYPM INSTALLATION AND STARTING-UP 1 5 0470CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0470TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0470MANU DOCUMENTATION AND MANUALS 1 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx. issue:01/11 CUT AWAY MOTORS. MEDIUM MODULE Ref: 0491 1 / 1 ITEM REFERENCE DESCRIPTION QTY. 1 EMT-S EMT-1S EMT-2S EMT-3S EMT-4S EMT-8S EMT-9S CUT AWAY MOTORS, FORMED BY: DC INDEPENDENT EXCITATION CUT AWAY MOTOR DC SERIES EXCITATION CUT AWAY DC SHUNT EXCITATION MOTOR DC COMPOUND EXCITATION MOTOR THREE-PHASE MOTOR WOUND ROTOR DAHLANDER THREE-PHASE 1500/3000 1 1 1 1 1 1 1 2 0470PARTS COMPONENTS AND SPARE PARTS 1 3 0470PA COMPLEMENTARY ITEM 1 4 0470IYPM INSTALLATION AND STARTING-UP 1 5 0470CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0470TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0470MANU DOCUMENTATION AND MANUALS 1 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx. issue:01/11 CUT AWAY MOTORS. ADVANCED MODULE Ref: 0492 ITEM 1 1 / 2 REFERENCE EMT-S EMT-7BS EMT-10S DESCRIPTION QTY. 1 1 1 EMT-18S EMT-19S EMT-20S EMT-21S EMT-22S CUT AWAY MOTORS, FORMED BY: THREE-PHASE MOTOR OF SQUIRREL CAGE (DOUBLE) 2 VELOCITIES THREE-PHASE EXCITATION CUT AWAY MOTOR REPULSION MOTOR D.C. PERMANENT MAGNETS MOTOR THREE-PHASE MOTOR OF SQUIRREL CAGE WITH "Y" CONNECTION BRUSHLESS MOTOR STEPPING MOTOR SPLIT PHASE MOTOR THREE-PHASE RELUCTANCE MOTOR SINGLE-PHASE SHADED POLE MOTOR 2 0470PARTS COMPONENTS AND SPARE PARTS 1 3 0470PA COMPLEMENTARY ITEM 1 4 0470IYPM INSTALLATION AND STARTING-UP 1 5 0470CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0470TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0470MANU DOCUMENTATION AND MANUALS 1 EMT-14S EMT-15S EMT-17S 1 1 1 1 1 1 1 1 Ref: 0492 2 / 2 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages 4.4- Electrical Machines (continuation) EMT-S. Cut Away Motors: Available cut away motors: -EMT1-S. -EMT2-S. -EMT3-S. -EMT4-S. -EMT5-S. -EMT6-S. -EMT7-S. DC Independent excitation motor-generator. DC Series excitation motor-generator. DC Shunt excitation motor-generator. DC Compound excitation motor-generator. DC Shunt-series compound excitation motor. AC Synchronous alternator motor. Asynchronous three-phase motor with squirrel cage. -EMT8-S. Asynchronous three-phase motor with wound rotor. -EMT9-S. Dahlander three-phase (two-speeds). -EMT10-S. Asynchronous three-phase motor with two independent speeds. -EMT11-S. Asynchronous single-phase motor with starting capacitor. -EMT12-S. Universal motor (single-phase). -EMT14-S. Repulsion motor, single-phase with shortcircuited brushes. -EMT15-S. DC Permanent magnet motor. -EMT16-S. Asynchronous single-phase motor with starting and running capacitor. -EMT17-S. Three-phase motor of squirrel cage with “Y” connection. -EMT18-S. DC Brushless motor. -EMT19-S. Stepper motor. -EMT20-S. Asynchronous single-phase motor with split phase. -EMT21-S. Three-phase Reluctance motor. -EMT22-S. Single-phase Shaded Pole motor. ESAM. Faults Simulation Trainer in Electrical Motors More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAM.pdf PRACTICAL POSSIBILITIES 1.- Detection of fault on a phase. 2.- Detection of fault on the supply voltage. 3.- Coils with turns in short circuit. 4.- Measurement the resistance of the windings. 5.- Detection of open-ended coil. 6.- Detection of short circuit in coils from different phase. 7.- Measurement the resistance between coils from different phases. 8.- Detection of ground fault. 9.- Measurement of the insulation resistance between the winding and the motor case. 10.- Motor in star connection. 11.- Motor in delta connection. ESAE. Electrical Faults Simulation Trainer SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Steel box. Diagram in the front panel with similar distribution that the elements in the real unit. With this trainer the following troubles or faults, among others, may be fixed and determined: -Power off. -Fuse blown. -Defective main circuit broker. Defective leak current coil relay. -Ground fault. -Detection of fault on the supply voltage. -Capacitor:Starting capacitor open and run capacitor open, starting capacitor shorted and run capacitor shorted. -Thermostat contacts stuck open and closed. -Relay contacts stuck closed. Relay windings open. -Fan:Fan motor windings open and shorted. Fan relay windings open and shorted. Fan relay contacts stuck closed. Fan relay contacts are rusting. Fan thermostat contacts stuck closed. Fan thermostat sensor bulb stuck opened. -Motor: Starting motor windings open and shorted. Running motor windings open and shorted. -Compressor: Thermal overload open. Compressor motor winding grounded. -Low voltage. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 400 x 330 x 400 mm. approx. Weight: 10 Kg. approx. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/ESAE.pdf EEA. Alternators Study Unit SPECIFICATIONS SUMMARY Unit for the study of alternators. Starting, operation and regulation of an alternator without load, half load and full load. The unit comprises: Base structure (painted steel and anodized aluminium). Couplings. Connectors. EMT7. Asyncrhonous Three-phase motor of squirrel cage: Power: 250-300W. Speed: 2769 r.p.m. (50Hz), 3330 r.p.m. (60Hz). Connections: Star/triangle. Frequency: 50/60 Hz. V.Armature:230/400V (50Hz), 250/440V. (60Hz). I.Armature nominal:1A-0.7A. EMT6. A. C. Syncrhonous alternator motor: Power: 250-300W. Speed: 3000 r.p.m. Frequency: 50Hz. Connections: Star/triangle. V.excitation nominal: 220V D.C. I.Excitation nominal: 0.59A. V.Armature.: 3x220/380V. VVCA/B. AC motors speed controller: This unit enables to change the speed of an asynchronous motor, obtaining features which characterize a motor. Maximum power: 750 W. Frequency from 0 to 60Hz. Cables and accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 750 mm x 250 mm x 250mm approx. Weight: 30Kg. approx. PRACTICAL POSSIBILITIES 1.- Starting, voltage and frequency regulation in a three -phase alternator. 2.- Typical practices for a three-phase alternator. 3.- Characteristic curve of an alternator without load. 4.- Characteristic curve of an alternator in short circuit. 5.- Characteristic curve of an alternator with load. 6.- Synchronous motor starting. 7.- Working at a frequency given. 8.- Curves in V at constant power (1/4, 1/3, ½,1) PN and different power factors. More information in: www.edibon.com/products/catalogues/en/ units/electricity/machines/EEA.pdf Page 69 www.edibon.com 4.- Electricity SPECIFICATIONS SUMMARY Teaching trainer for the simulation of non-destructive faults in three-phase motors. Application of diagnostic and localization. Unit and motor are mounted in a painted steel structure. Unit: Steel box. Electrical diagram of the motor on the front panel. The motor can be connected in star or delta connection. Connections for the measurements. The resistance of the windings can be measured. Pilot lamps. 6-position selector for the selection of the fault sequences. Switch for faults activation. Faults are implemented by means a PLC and internal relays. This lets the motor can keep on working in different conditions when certain faults are caused. 6 fuses of 2A to protect the motor. Automatic Magnetothermal Differential switch. Dahlander three-phase motor (0.3 to 0.5 CV), including cable and connector. Cables and Accessories, for normal operation. Manuals: This unit is supplied with 8 manuals. Dimensions: 800 mm x 400 mm x 400 mm approx. Weight: 30Kg. approx. Advanced Electrical Machines Laboratory (4EMAD) List of modules and teaching units included plus Summarised Catalogues Priority 2 0400 Electricity 0433-430/10S: Industrial Electric Installations (10 CAI + CAL) 0500 Energy 0510: Energy: Modular Power System Simulator Basic Module 0511: Energy: Modular Power Simulator (ESN) Ref.:4EMAD-pre(01/11) issue:01/11 INDUSTRIAL ELECTRIC INSTALLATIONS (10 CAI + CAL) Ref: 0433-430/10S ITEM 1 REFERENCE 1 / 3 DESCRIPTION QTY. LIELBA . "INDUSTRIAL " ELECTRICAL INSTALLATIONS INTEGRATED LABORATORY, FORMED BY: AI1 ALI01 ALI03 CON01 IAM20 APPLICATION - STAR - DELTA STARTER,INCLUDED: INDUSTRIAL MAIN POWER SUPPLY. AC AUXILIARY POWER SUPPLY (24 VAC). 3-POLES CONTACTOR (24 VAC). 3-POLE MAGNETO-THERMAL AUTOMATIC SWITCH 4 A, CURVE C. NETWORK ANALYZER. PUSH-BUTTONS WITH LIGHT (24 VAC). THERMAL RELAY (1.6 - 2.5 A). TIME RELAY (0.6 - 60 SEC.). MOTOR (EMT7) (SQUIRREL CAGE). 1 1 1 3 1 MED60 PUL04 REL02 REL11 VAR02 1 1 1 1 1 2 AI1/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THE APPLICATION - STAR - DELTA STARTER 10 3 AI1/CAL COMPUTER AIDED LEARNING SOFTWARE FOR THE APPLICATION - STAR - DELTA STARTER. (RESULTS CALCULATION AND ANALYSIS) 10 4 AI4 ALI01 CAR30 CAR31 CAR32 CAR33 LAM09 LAM26 MED65 REL50 VAR02 VAR15 TRA28 VAR16 APPLICATION - STARTER- INVERTER, INCLUDED: INDUSTRIAL MAIN POWER SUPPLY. INDUCTANCES MODULE CAPACITORS MODULE RECTIFIER DIODES MODULE RESISTIVE COMPONENTS MODULE FLUORESCENT LAMP. LIGHTING MODULE DIGITAL MULTIMETER. RELAYS MOTOR (EMT7) (SQUIRREL CAGE). SINGLE-PHASE MOTOR OF CAPACITOR THREE-PHASE TRANSFORMER ELECTROMAGNETISM KITS WITH GROUP OF MOTORGENERATOR DISMANTLED TRANSFORMER KIT ELECTROSTATIC KIT OPEN UNIVERSAL MOTOR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 VAR17 VAR18 VAR25 1 1 1 5 AI4/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THE APPLICATION - STARTER- INVERTER 10 6 AI4/CAL COMPUTER AIDED LEARNING SOFTWARE FOR THE APPLICATION - STARTER- INVERTER. (RESULTS CALCULATION AND ANALYSIS) 10 7 AI6 ALI01 ALI04 CAR23 VAR04 APPLICATION - DC MOTOR STARTER, INCLUDED: INDUSTRIAL MAIN POWER SUPPLY. DC AUXILIARY POWER SUPPLY (+ 12, 0, -12VDC). DC STARTING RHEOSTAT. MOTOR (EMT5) (DC MOTOR). 1 1 1 1 1 Ref: 0433-430/10S ITEM 7 2 / 3 REFERENCE PUL04 CON03 IAM20 CAR20 DESCRIPTION QTY. PUSH-BUTTONS WITH LIGHT (24 VAC). 3-POLES CONTACTOR (12 VDC). 3-POLE MAGNETO-THERMAL AUTOMATIC SWITCH 4 A, CURVE C. DIODES AND THYRISTORS. 1 1 1 1 8 AI6/SOF* COMPUTER AIDED INSTRUCTION SOFTWARE OF THE APPLICATION - DC MOTOR STARTER 10 9 AI6/CAL COMPUTER AIDED LEARNING SOFTWARE FOR THE APPLICATION - DC MOTOR STARTER. (RESULTS CALCULATION AND ANALYSIS) 10 10 INS/SOF CLASSROOM MANAGEMENT SOFTWARE PACKAGE (TEACHER'S SOFTWARE) 1 11 MUAD 1 EPIB DAB MUAD/SOF ELECTRIC POWER DATA ACQUISITION SYSTEM,INCLUDED: ELECTRIC POWER INTERFACE BOX DATA ACQUISITION BOARD DATA ACQUISITION SOFTWARE 1 1 1 12 CABD CABLES KIT 1 13 0420PARTS COMPONENTS AND SPARE PARTS 1 14 0420PA COMPLEMENTARY ITEM 1 15 0420IYPM INSTALLATION AND STARTING-UP 1 16 0420CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 17 0420TD TEACHING TECHNIQUES "KNOW-HOW" 1 18 0420MANU DOCUMENTATION AND MANUALS 1 Ref: 0433-430/10S 3 / 3 * Each Software Package contains the following parts: Theory, Exercises, Guided Practices, Self-evaluation (exam), Video and Statistical analysis. Notes: 1) Multipost option: This module is for 10 students post, but we can recommend the number of units for 20 or 30 students working simultaneously. 2)Supply conditions included: a) Technical conditions: - Laboratories adaptation. - Installation of all units supplied. - Starting up for all units. - Training about the exercises to be done any unit. - Teacher training related with the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit . . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. Calibration manual. See Catalogues in next pages 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: 2 1 APPLICATIONS Frame 2 (applications support) (AD1A) (AI1) (BASB) Modules automatic anchorage system High Safety (AD3A) APPLICATIONS Automatic earth connection system (AI2) Sight of the frame with some modules allocated or (BASS) (AD5) (AI4) (AI5) (AD6A) 3 4.- Electricity Sight of the frame with some modules allocated CAI. Computer Aided Instruction Software System Teaching Technique used (AD8) INS/SOF. (AE7) Teacher Software EMT../SOF. Student/Module Software (AD9A) 4 (AE8) MUAD. Electric Power Data Acquisition System Teaching Technique used EPIB. Electric power interface box (AD13) (AE9) DAB. Data adquisition board MUAD/SOF. Power Data acquisition System 5 Manuals Other APPLICATIONS TOTALLY SAFETY SYSTEM Other APPLICATIONS The complete laboratory includes part 1, 2, 3, 4, and 5 ,and any part can be supplied individually or additionally. Minimum supply: Frame (BASB or BASS) + one Application + Manuals. Available Applications: ! Domestic Electric Installations: AD1A. Robbery alarm station. AD3A. Fire alarm station. AD5. Temporization of stairs. AD6A. Luminosity control station. AD8. Blinds activator. AD9A. Heating control station. AD11A. Network analyzer. AD13. Audio door entry system. AD14. Audio and video door entry system. AD15A. Position control station. AD17A. Photoelectric control position station. AD24. Position Switch. AD19A. Sound station. AD22. Flooding control station. AD23. Wireless basic control station (RF). AD25A. C o n t r o l s t a t i o n f o r domestic electric services through the telephone. AD28A. Integral control station of domestic electric systems. AD30. Gas control station. AD31. Movement and sound detection and control. AD32. 24 Vac / 12 Vdc circuits analyzer. AD33. I n s t a l l a t i o n s f a u l t s simulator. ! Industrial Electric Installations: AI1. Star-delta starter. AI2. S t a r t e r t h r o u g h a u t o transformer. AI3. Speed commutator for Dahlander motor. AI4. Starter-inverter. AI5. AC wound rotor motor starter. AI6. DC motor starter. AI7. Automatic change of speed of a Dahlander motor with change of direction. AI8. R e a c t i v e p o w e r c o m pensation (Power factor correction). AI9. Pe o p l e s a f e t y a g a i n s t indirect electrical contacts in TT neutral regimen. AI10. People safety against indirect electrical contacts in TN neutral regimen. AI11. People safety against indirect electrical contacts in IT neutral regimen. AI12. Modular Trainer(AC motors). AI13. Modular Trainer for Electrotecnics. ! Energy Installations: AE1. Aerial line model. AE2. Reactive energy control and compensation. AE3. Test unit for magneto-thermal automatic switches. AE4. Test unit for differential automatic switches. AE5. Relay control station. AE6. Energy counters control station. AE7. Multi-functional electrical protection station. AE8. Power & torque measurements of electrical motors. AE9. Directional Relay: Earth fault detection. Directional power flow detection. Reactive power flow detection. More information in: www.edibon.com/products/catalogues/en/units/electricity/basic/LIELBA.pdf Page 37 www.edibon.com 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: 1 (continuation) (continuation) Frame Applications support. There are two options to chose: BAS-B. Basic Frame SPECIFICATIONS SUMMARY Anodized aluminium structure and modular building. Possibility of housing up to 10 different modules. Automatic anchorage system for any module. Automatic earth connection system. or BASS. Double Frame SPECIFICATIONS SUMMARY 4.- Electricity Double frame, single side working post. Anodized aluminium structure and modular building. Dimensions approx.:1300mm x 800mm x 700mm. Possibility of housing until 12 different modules at the same time. Transparent internal separation. Automatic anchorage system for any module. Automatic earth connection system. Dimensions: 1300x800x700mm. approx. Weight: 2 Applications Main features: Painted steel modules. All modules have handles and diagram. Automatic anchorage system for housing the modules in the frame. Automatic earth connection in the modules. Safety connections. Safety wires. There is a manual for each application (8 manuals normally supplied). Domestic Electrical Installations AD1A. Robbery Alarm Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). DET27. Glass Break Detector. INT32. Intrusion Switch/Detector with Relay 1000W. (2 units). SEL03. 3 Pilot-Lights. SEL21. Indoor Siren. VAR07. Kit: Burglar Alarm Central + infrared ele. + battery. PRACTICAL POSSIBILITIES 1.- Assembly of the station with intrusion detector and alarm. 2.- Assembly of the station with glass breaking detector and alarm. 3.- Assembly of the station with both types of detectors and alarm. 4.- Assembly of the station with infrared detectors. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AD1A.pdf AD3A. Fire Alarm Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). ALA02. Fire Alarm Station (with battery). DET06. Smoke Detector for domestic control. DET21. Fire Detector through Ionization for Central. SEL21. Indoor Siren. DET10. Water Electro-valve. DET22. Fire Thermal Detector. SEL17. Fire Indicators, Bell type. PRACTICAL POSSIBILITIES 1.- Assembly of the station with fire detector, smoke detector and alarm. 2.- Test of the station with fire detector. 3.- Test of the station with smoke detector. 4.- Test of the station with detection of fire by the thermal detector. 5.- Activation of the electro-valve following the detection of the fire. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD5. Temporization of Stairs SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. CTI10. Automatic of Stairs. INT21. Switch+Commutator Group+Bell Push-Button. LAM08. 2 Lamp-holders + Incandescent Lamps 40W. (2 units). LAM13. 2 Low Consumption Fluorescent Lamps. (2 units). PRACTICAL POSSIBILITIES 1.- Assembly of the basic set of temporization. 2.- Test of the set from two points with incandescent lamps. 3.- Test of the set from two points with fluorescent lamps. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AD5.pdf AD6A. Luminosity Control Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. COM14. 2 Commutators. LAM08. 2 Lamp-holders + Incandescent Lamps 40W. REG06. Voltage Electronic Regulator (Switch) 40 to 300W/230Vac. INT18. 1-pole Switch + 1-pole Switch with Light. LAM10. 2 Halogen Lamps. LAM09. Fluorescent Lamp. SEN26. Presence and Movement Sensor (Wall). More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AD6A.pdf Page 38 PRACTICAL POSSIBILITIES 1.2.3.4.5.6.- Assembly of the control station. Control of luminosity of an halogen lamp. Control of luminosity of an incandescent lamp. Test of the station by movement sensor. Luminosity control. Complete control. 4.1- Basic Electricity (continuation) LIELBA. Electrical Installations Integrated Laboratory: 2 (continuation) Applications (continuation) Domestic Electrical Installations (continuation) AD8. Blinds Activator SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. INT22. 2 Switches for Blinds. DET19. Twilight Detector. DET20. Light Detector. VAR01. Motor for Blinds / Curtains. PUL29. 2 Push-Buttons Group for Blinds (without Interlock). PUL30. 2 Push-Buttons Group for Blinds (with Interlock). PRACTICAL POSSIBILITIES 1.- Assembly of the activator (motor, detectors and switches). 2.- Blind activation by pulsators (push-buttons). 3.- Blind activation by sensors. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD9A. Heating Control Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. MED76. Thermostat for Heating. MED77. Thermostat for Heating and Refrigeration. SEL09. 2 Double Luminous Signalling red-green 230Vac. (2 units). TIM01. 2 Bell 70dB,230V. (2 units). PRACTICAL POSSIBILITIES 1.- Assembly of the heating control station. 2.- Assembly of the heating and refrigeration control. 3.- Test with several temperatures. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. MED11. AC Ammeter (0-10A). MED25. Pointer Frequency Meter(45-65Hz). MED32. 1-Phase Wattmeter 230V. MED21. AC Voltmeter (0-250V). MED30. 1-Phase Phasemeter 230V. MED38. 1-Phase Varmeter 230V. MED12. AC Ammeter (custom made). (3 units). MED22. AC Voltmeter (0-400V). (3 units). MED31. 3-Phase Phasemeter 400V. (3 units). MED39. 3-Phase Balanced Varmeter 440V. MED33. 3-Phase Balanced Wattmeter 440V. MED63. Synchronoscope. MED64. Phase Sequence Indicator. PRACTICAL POSSIBILITIES 1.- Assembly of the analyzer to measure current, voltage, frequency, active power, reactive power, sequence of phases of a 220V single-phase circuit. 2.- Assembly of the analyzer to measure current, voltage, frequency, active power, reactive power, sequence of phases of a 380V three-phase circuit. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD13. Audio Door Entry System SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. POR01. Phones Power Supply. POR02. Phone. POR03. Interphone. POR06. Lock. PRACTICAL POSSIBILITIES 1.- Assembly of the system. 2.- To check the interphone operation. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD14. Audio and Video Door Entry System SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. POR06. Lock. POR05. Phone/Monitor. POR04. Video Camera. POR07. Digital Station. POR08. Video-Interphone Power Supply. PRACTICAL POSSIBILITIES 1.- Assembly of the system. 2.- To check of the video and audio operation. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AD14.pdf AD15A. Position Control Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). INT14. 1-pole 2 Switches. SEL01. Light Signalling Beacons. SEN04. Cylindrical Inductive Proximity Sensor type PNP. SEN14. AC Cylindrical Capacitive Proximity Sensor. SEN29. AC Cylindrical Inductive Proximity Sensor. SEN01. Instantaneous Micro-Switch. SEN26. Presence and Movement Sensor (Wall). PRACTICAL POSSIBILITIES 1.2.3.4.- Assembly of the station with sensors. Test of the capacitive detection of a body. Test of the inductive position detection of a body. Assembly of the station with presence and movement wall sensor. 5.- To check the movement detection of a body. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD17A. Photoelectric Control Position Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). LAM04. 3 Push-buttons and Lamps (24Vac). (2 units). SEN18. Cylindrical Photoelectric Sensor. SEN19. Miniature Photoelectric Sensor. SEN20. Compact Photoelectric Sensor. SEN21. Barrier Photoelectric Sensor (Emitter). SEN22. Barrier Photoelectric Sensor (Receptor). SEN23. Reflecting Photoelectric Sensor (Emitter). SEN24. Reflecting Photoelectric Sensor (Receptor). PRACTICAL POSSIBILITIES 1.2.3.4.5.6.7.- Assembly of the control station. Test of the detection with cylindrical sensor. Test of the detection with miniature sensor. Test of the detection with compact sensor. Assembly of the control station with battery and sensors. Test of the detection with emitters and receivers. Test with only emitters and receptors. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf Page 39 www.edibon.com 4.- Electricity AD11A. Network Analyzer 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: 2 (continuation) (continuation) Applications (continuation) Domestic Electrical Installations (continuation) AD24. Position Switch SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply. LAM03. 3 Push-buttons and Lamps (220Vac). SEN01. Instantaneous Micro-switch. SEN02. MBB Micro-switch. SEN03. BBM Micro-switch. PRACTICAL POSSIBILITIES 1.- Instantaneous Micro-switch. 2.- MBB Micro-switch. 3.- BBM Micro-switch. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD19A. Sound Station SPECIFICATIONS SUMMARY 4.- Electricity Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). AUD01. Analog Sound Regulator. AUD04. Speaker of 2”, 2W, 8 ohm. (3 units). AUD06. Basic Audio Central. AUD20. Analog Sound Regulator (mono-stereo). AUD02. Digital Sound Regulator. AUD05. Speaker of 4”, 7W, 8 ohm. (3 units). AUD03. Warnings Emitter Module. AUD08. Background Music Regulator 3W. AUD10. Double Background Music Regulator. PRACTICAL POSSIBILITIES 1.2.3.4.5.- Mono-stereo system installation. Mono system with warnings reception. Mono-stereo system installation with warnings reception. Stereo system installation with warnings reception. Background Music installation. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD22. Flooding Control Station SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). DET03. Fitted Power Supply (gas and flooding detector). DET04. Flooding Detector (with probe). DET10. Water Electro-valve. DET11. Probe for Water Electro-valve. (2 units). SEL03. 3 Pilot-Lights. SEL21. Indoor Siren. PRACTICAL POSSIBILITIES 1.- Assembly of the flooding control with a probe. 2.- Test of the flooding control. 3.- Test of the flooding control acting on an eletro-valve. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD23. Wireless Basic Control Station (RF) SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). DET13. Wireless Intrusion Detector RF. DET14. Wireless Panic Push-button RF. DET15. Wireless 1-channel Receptor RF. DET15. Wireless 1-channel Receptor RF. SEL01. Light Signalling Beacons. TIM05. Bell + Buzzer. PRACTICAL POSSIBILITIES 1.- Wireless intrusion detection and alarm. 2.- Wireless panic button alarm. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD25A. Control Station for Domestic Electric Services through the Telephone SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CTR01. Basic Control Module. DET01. Flooding Detector. DET03. Fitted Power Supply (gas and flooding detector). (3units). DET04. Flooding Detector (with probe). DET05. Gas Detector for domestic control. DET06. Smoke Detector for domestic control. DET10. Water Electro-valve. DET12. Gas Electro-valve. DET13. Wireless Intrusion Detector RF. DET14. Wireless Panic Push-button RF. DET15. Wireless 1-channel Receptor RF. VAR05. Tones Dialling Telephone. PRACTICAL POSSIBILITIES 1.2.3.4.5.6.7.- Smoke detection. Gas detection and electro-valve control. Flooding detection and electro-valve control. Temperature and Battery. Intrusion detection. Wireless detection. Complete control of home electric services through the telephone. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD28A. Integral Control Station of Domestic Electric Systems SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CTR02. Advanced Control Module. CTR05. Power Module 72W. CTR07. Timers Module. CTR08. Inputs Module 24V. CTR11. Outputs Module 24V. CTR17. Infrared Remote Control for Control Modules. CTR18. Infrared Receptor. DET04. Flooding Detector (with probe). DET05. Gas Detector for domestic control. DET06. Smoke Detector for domestic control. DET09. Intrusion Detector for domestic control. DET10. Water Electro-valve. DET12. Gas Electro-valve. VAR08. Monitor. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AD28A.pdf Page 40 PRACTICAL POSSIBILITIES 1.- Assembly of the complete system with the smoke, flooding and gas detectors. 2.- Test of the station with smoke, flooding and gas detectors. 3.- To set the temporization and monitoring the results. 4.- Assembly of the complete system with infrared and instrusion detectors. 5.- Test of the station with infrared and instrusion detectors. 6.- Electro-valves activation. 7.- Wireless assembly of the sensor through infrared control. 4.1- Basic Electricity (continuation) LIELBA. Electrical Installations Integrated Laboratory: 2 AD30. Gas Control Station (continuation) Applications (continuation) Domestic Electrical Installations (continuation) SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). DET12. Gas Electro-valve. DET03. Fitted Power Supply (gas and flooding detector). DET02. Gas Detector. PRACTICAL POSSIBILITIES 1.- Gas detection. 2.- Electro-valve activation. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD31. Movement and Sound Detection and Control SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. INT15. 2 Switches with Light. LAM08. 2 Lamp-holders + Incandescent Lamps 40W. INT31. Intrusion Switch/Detector from 40 to 300W. LAM10. 2 Halogen Lamps. PUL22. 2 Light Push-Buttons. TIM05. Bell + Buzzer. PRACTICAL POSSIBILITIES 1.- Movement and sound detection controlled by switches. 2.- Movement and sound detection controlled by pulsators. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). ALI04. DC Auxiliary Power Supply (+12, 0, -12 Vdc). MED04. DC Milliammeter (0-600 mA). MED05. DC Ammeter (0-1.5A). MED08. AC Milliammeter (0-600mA). MED09. AC Ammeter (0-2.5A). MED15. DC Voltmeter (0-5V). MED16. DC Voltmeter (0-50V). MED19. AC Voltmeter (0-10V). MED20. AC Voltmeter (0-60V). PRACTICAL POSSIBILITIES 4.- Electricity AD32. 24vac/12vdc Circuits Analyzer 1.- AC circuits analyzer (2 ranges). 2.- DC circuits analyzer (2 ranges). More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AD33. Installations Faults Simulator PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. COM14. 2 Commutators (2 units). ENC09. 2-pole European Socket with Safety Device.(2 units). COM21.Inverter + Group of 2 Commutators. (2 units). LAM01. Lamps. LAM08. 2 Lamp-holders + Incandescent Lamps 40W. (2 units). LAM09. Fluorescent Lamp. MED65. Digital Multimeter. FUS04. 3 Fuse-holders 10A, 230Vac (include 2, 4,6,10A). Fault box. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf 1.2.3.4.5.6.7.8.9.- Ground fault simulation of a plug base. Fault simulation between phases of a plug base. Ground fault simulation of an incandescent lamp base. Ground fault simulation of a fluorescent lamp base. Fault simulation between phases of an incandescent lamp base. To simulate fault of power-supply contact in the lamp base. To simulate fault of contact of the switch. To simulate fault of contact of the fuse. To simulate fault of contact of the fluorescent base. Industrial Electrical Installations AI1. Star-Delta Starter SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CON01. 3-pole Contactor (24Vac. (3 units)). IAM20. 3-pole Magneto-thermal Automatic Switch, 4A, Curve C. MED60. Network Analyzer. PUL04. Push-Buttons with Light (24Vac). REL02. Thermal Relay (1.6-2.5A). REL11. Time Relay (0.6-60 sec.). VAR02. Motor (EMT7) (squirrel cage). PRACTICAL POSSIBILITIES 1.2.3.4.- Assembly of the starter. Test of the starter with a squirrel cage motor. Measurement of the star current and delta current. Direct start of the motor. Measurement of the starting current. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AI2 Starter through Auto-transformer SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CON01. 3-pole Contactor (24Vac). (3 units). IAM20. 3-pole Magneto-thermal Automatic Switch, 4A, Curve C. MED60. Network Analyzer. PUL04. Push-Buttons with Light (24Vac). REL02. Thermal Relay (1.6-2.5A). REL11. Time Relay (0.6-60 sec.). TRA14. 3-Phase Auto-transformer. VAR02. Motor (EMT7) (squirrel cage). PRACTICAL POSSIBILITIES 1.- Assembly of the starter. 2.- Test of the starter with a squirrel cage motor. 3.- Measurement of both the star and delta current. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AI3. Speed Commutator for Dahlander Motor SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CON01. 3-pole Contactor (24Vac). (3 units). IAM20. 3-pole Magneto-thermal Automatic Switch, 4A, Curve C. MED60. Network Analyzer. PUL04. Push-Buttons with Light (24Vac). REL02. Thermal Relay (1.6-2.5A). REL11. Time Relay (0.6-60 sec.). VAR03. Motor (EMT9) (Dahlander motor). PRACTICAL POSSIBILITIES 1.- Assembly of the commutator. 2.- Test of the commutator changing the speed of a Dahlander motor. 3.- Measurement of the voltage and current. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf Page 41 www.edibon.com 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: 2 (continuation) (continuation) Applications (continuation) Industrial Electrical Installations (continuation) AI4. Starter-Inverter SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CON02. 3-pole Contactor (220Vac). CON11. 3-pole Contactor- Inverter (220Vac). MED60. Network Analyzer. PUL03. Push-Buttons with Light (220Vac).(2 units). REL05. Thermal Relay/3-pole Phase fault (0.8-1.2A). VAR02. Motor (EMT7) (squirrel cage). PRACTICAL POSSIBILITIES 1.- Assembly of the starter. 2.- To test of the direct start of a squirrel cage motor. 3.- To invert the rotation direction of the motor. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AI5. AC Wound Rotor Motor Starter SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). VAR06. Motor (EMT8) (wound rotor). CAR22. AC Starting Rheostat. IAM20. 3-pole Magneto-thermal Automatic Switch, 4A, Curve C. CON01. 3-pole Contactor (24Vac). PUL04. Push-Buttons with Light (24Vac). PRACTICAL POSSIBILITIES 1.- Assembly of the starter. 2.- To test the starter changing the resistances step by step. More information in: www.edibon.com/products/ 4.- Electricity catalogues/en/units/electricity/basic/LIELBA.pdf AI6. DC Motor Starter SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI04. DC Auxiliary Power Supply (+12, 0, -12 Vdc). VAR04. Motor (EMT5) (DC motor). CAR23. DC Starting Rheostat. IAM20. 3-pole Magneto-thermal Automatic Switch, 4A, Curve C. CON03. 3-pole Contactor (12Vdc). PUL04. Push-Buttons with Light (24Vac). CAR20. Diodes and Thyristors. PRACTICAL POSSIBILITIES 1.- Direct starter. 2.- Starter rheostat. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AI7. Automatic Change of Speed of a Dahlander Motor with Change of Direction SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. IAM24. 3-pole+neutral Magneto-thermal Automatic Switch, 6A, Curve C. CON01. 3-pole Contactor (24Vac). (5 units). REL05. Thermal Relay/3-pole Phase fault (0.8-1.2A). (2 units). PUL16. Push-Button for Industrial use (NC Contacts). (5 units). PUL16. Push-Button for Industrial use (NO Contacts). (5 units). VAR03. Motor (EMT9) (Dahlander motor). More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf PRACTICAL POSSIBILITIES 1.- Assembly of the set. 2.- Motor starting with right turning direction at high speed. R.p.m and consumption measurements. 3.- Motor stop and change to left the turning direction at high speed. 4.- Change to low speed. 5.- Motor stop and change to right the turning direction. 6.- Change to high speed. R.p.m and consumption measurements. AI8. Reactive Power Compensation (Power Factor Correction) SPECIFICATIONS SUMMARY Included Modules: ALI02. Domestic Main Power Supply. CAR04. Variable Resistive Load,150 ohm, 500W. CAR09. Capacitive Load 4 x 7 mF. CAR12. Inductive Load 0-33-78-140-193-236 mH. (2 units). MED60B.Network Analyzer with active and reactive energy counters. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AI8.pdf PRACTICAL POSSIBILITIES 1.2.3.4.5.6.7.- Measurement of active power consumed by a receiver. Measurement of reactive power consumed by a receiver. Measurement of apparent power consumed by a receiver. Measurement of power factor of a receiver. Measurement of active energy consumed by a receiver. Measurement of reactive energy consumed by a receiver. Compensation of reactive energy (improvement of the power factor). 8.- Comparison of the active energy consumed after the compensation. 9.- Comparison of the reactive energy consumed after the compensation. 10.-Measurement of power factor after the compensation. AI9. People Safety against Indirect Electrical Contacts in TT Neutral Regimen SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR05. Double Variable Resistive Load , 150 ohm, 500 W. Resistance 1600 W. COM12.Commutator/Switch. PUL11. 2 Double Push-Buttons (230Vac). TRA12. 3-Phase Current Transformer. IAD13. 3-pole + neutral Differential Automatic Switch, 25A, 300mA, class AC, instantaneous. PRACTICAL POSSIBILITIES 1.- Study of an isolation fault in TT neutral regimen. 2.- Structure of a differential switch. Necessity to use a differential switch. 3.- Study of the selectivity among differential switches. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AI10. People Safety against Indirect Electrical Contacts in TN Neutral Regimen SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. COM12.Commutator/Switch. (2 units). TRA12. 3-Phase Current Transformer. IAD01. 1-pole+neutral Differential Automatic Switch, 6A, 30mA, class A. Resistance 200 W. Resistance 100 W, 72W. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf Page 42 PRACTICAL POSSIBILITIES 1.2.3.4.- Study of an isolation fault in TN neutral regimen. Measurement of the ground loop impedances. Indirect contact with defect mass. The case in which the automatic switches are not suitable in TN-C conditions. 5.- The case in which the automatic switches are not suitable in TN-S conditions. 4.1- Basic Electricity (continuation) LIELBA. Electrical Installations Integrated Laboratory: (continuation) 2 Applications (continuation) Industrial Electrical Installations (continuation) AI11. People Safety against Indirect Electrical Contacts in IT Neutral Regimen SPECIFICATIONS SUMMARY PRACTICAL POSSIBILITIES Included Modules: ALI01. Industrial Main Power Supply. INT01. 1-pole Load Switch. (2 units). INT02. 2-pole Load Switch. (2 units). CPA. Isolation Permanent Controller. Capacitor 300V. 200 nF .(2 units). Resistance 100 W. Resistance 10 W. 2.- Study of an isolation double fault (only with one mass). More information in: 4.- Operation of the isolation controller. 1.- Study of an isolation simple fault. 5.- Study of the ground loop impedance. 3.- Study with several masses. www.edibon.com/products/catalogues/en/ units/electricity/basic/LIELBA.pdf A12. Modular Trainer (AC Motors) SPECIFICATIONS SUMMARY More information in: www.edibon.com/products/catalogues/en/ units/electricity/basic/AI12.pdf PRACTICAL POSSIBILITIES 1.- Direct starting of a three-phase motor through contactor, with some stop and start push-buttons. 2.- Configuration of a magnetic protection system, with stop mush room button. 3.- Direct starting of a three-phase motor by GV protector with a switch. 4.- Direct starting of a three-phase motor through impulses contactor. 5.- Direct starting of a three-phase motor by GV protector with pushbuttons and signalling. 6.- Direct starting of a three-phase motor by GV protector with two boxes of push-buttons and signalling. 7.- Turning inverted starter of a threephase motor stopping before turning in the opposite direction. 8.- Turning inverted starter of a threephase motor without stopping before turning in the opposite direction. 9.- Turning inverted starter of a three- phase motor with microswitch and push-buttons box. 10.- Star-delta starting with an turn inverter of a three-phase motor. 11.- Automatic star-delta starting of a three-phase motor. 12.- Turning inverted starter of a threephase motor with microswitch, with start push-buttons, stop and function cycle. (Direct). 13.- Manual star-delta starting of a three-phase motor. 14.- Control of a single phase motor direct and, with time-delay connection and disconnection. 15.- Starting of a three-phase motor with single- phase voltage. 16.- Motor speed control with a variator. 17.-Parameters of the motor through software. 18.-Control of a two-speeds Dahlander motor. AI13. Modular Trainer for Electrotecnics SPECIFICATIONS SUMMARY Included Modules: ALI10. Power Supply Module CAR30. Inductances Module CAR31. Capacitors Module CAR32. Rectifier Diodes Module CAR33 .Resistive Components Module LAM09. Fluorescent Lamp LAM26. Lighting Module MED65.Digital Multimeter REL50. Relays Module. VAR02. Motor (EMT7) (squirrel cage) VAR15. Single-phase motor of capacitor. TRA28. Three-phase transformer VAR16. Electromagnetism Kits with group of motor/generator VAR17. Dismantled transformer kit VAR18. Electrostatic kit VAR25. Open Universal Motor. More information in: www.edibon.com/products/catalogues/en/ units/electricity/basic/AI13.pdf PRACTICAL POSSIBILITIES Estatic Electricity: 1.- Static electricity checking,with an electroscope and anelectrometer. 2.- Static electricity experiments. Direct current (DC) and Alternating Current (AC): 3.- Ohm´s law verification. 4.- Installation of the resistive components module. 5.- Total resistance of a circuit in series. 6. Resistance of a circuit in parallel. 7.- Power measurement of a resistive circuit. 8.- Total resistance of a circuit in series/in parallel. 9.- Connection of lamps in series. 10.-Lamps in parallel. 11.-Analysis of the variable resistances response curve. 12.-Voltage divider analysis. 13.-Lamp with variable lighting. 14.-Simplification systems: Application of Kirchhoff´s first law. Application of Kirchhoff´s second law. Thevenin´s and Norton´s Theorem. 15.-Application of the superposition theorem. 16.-Resistive circuits in delta. 17.-Measurement and visualization of the alternating current. 18.-Measurement of the phase angle among voltages (AC). Dynamic Electricity: 19.- Identification of the components of the trainer. 20.-Preparation of the power supply and of the measurement instruments Electric capacity: 21.-Load and unload analysis of a capacitor. Magnetism, Electromagnetism and Electromagnetic induction: 22.-Electromagnetic Induction. 23.-Electromagnetic Induction. 24.- Electromagnet: Oersted's experiment. 25.- The electromagnetic field (Electromagnets). Motors: 26.-Electric motors 27.-Generators. Page 43 28.-Identification, coils measurement and starting-up of a single-phase motor. 29.-Identification, measurement and starting-up of an universal motor. 30.-Identification, coils measuremt and starting-up of a three phase motor. Transformers: 31.-Experiments and practices with a dismantled transformer. 32.-Identification of the three-phase transformer. 33.-Connection as single-phase transformer. 34.-Star/star three-phase connection. 35.-Reverse star/star three-phase connection . 36.-Direct delta/delta three-phase connection. 37.-Star/delta three-phase connection. 38.-Three-phase/six-phase connection. 39.-Transformer with coils in series in phase. RL, RC and RCL Circuits: 40.-Analysis of a RL circuit in series. 41.-Analysis of a RL circuit in parallel. 42.-Analysis of a RC circuit in series. 43.-Analysis of a RC circuit in parallel. 44.-Analysis of a RLC circuit in series. 45.-Analysis of a RLC circuit in parallel. Rectification and filtrate: 46.-Analysis of the rectifier diode response curve. 47.-Half wave rectification . 48.-Rectification to feed the universal motor. 49.-Double wave rectification with two windings. 50.-Double wave with a Graezt's bridge. 51.-Half wave three-phase rectification. 52.-Three-phase rectification in bridge. Electric circuits: 53.-Basic electric installation with lamps. 54.-Lamps controlled from two points and from three points. 55.-Lamps control by a switch relay. 56.-Lamps control by a commutato relay. 57.-Installation of a fluorescent tube www.edibon.com 4.- Electricity Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). PUL48. 3 Double Chamber Push-buttons. (2 units). LAM02. Auxiliary Lamps(3 lamps. CON01. 3-pole Contactor (24Vac). (4 units). VAR09. Frequency variator. REL30. Synchronization Relay (variable delay). REL47. Thermal relay (GV protector) module (2 units). REL45. Module with disjunctor. IAM31. 4-pole Magneto-thermal Automatic Switch,4A,Curve C FUS10. Module with 3 fuse-holders and power fuses. TRA06. 3-Phase Power Transformer (custom made). CAR10. Capacitive Load (custom made). VAR02. Motor (EMT7) (squirrel cage). VAR03. Motor (EMT9) (Dahlander motor). VAR15. Single-phase motor of capacitor. 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: 2 (continuation) (continuation) Applications (continuation) Energy Installations AE1. Aerial Line Model SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR08. 3-phase Variable Resistive Load (custom made). CAR11. 3-phase Capacitive Load. CAR14. 3-phase Inductive Load. TRA05. 3-Phase Power Transformer 220/127V, 1000VA. CAR18. Aerial Line Model. TRA18. Petersen Coil. PRACTICAL POSSIBILITIES 1.2.3.4.5.- Assembly of the set. Measurement of the voltage without loads. Measurement of the voltage with loads. Power Factor (cos j) measurement. Fault to earth and measurement of the current through the Petersen coil. 1.2.3.4.- Assembly of the set with inductive load. Power Factor (cos j) measurement. To calculate the necessary capacitors to get cos j= 1. Capacitors connection and power factor measurement. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AE1.pdf AE2. Reactive Energy Control and Compensation SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR08. 3-phase Variable Resistive Load (custom made). CAR11. 3-phase Capacitive Load. CAR14. 3-phase Inductive Load. More information in: www.edibon.com/products/ PRACTICAL POSSIBILITIES catalogues/en/units/electricity/basic/AE2.pdf AE3. Test Unit for Magneto-thermal Automatic Switches 4.- Electricity SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR04. Variable Resistive Load, 150 ohm, 500W. IAM13. 2-pole Magneto-thermal Automatic Switch, 1A, Curve C. TRA19. Transformer for Experiments (custom made). PRACTICAL POSSIBILITIES 1.- To connect the set. 2.- To simulate a high current (thermal) and to test if the automatic switch breaks. 3.- To measure the current and to check the tripping. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AE4. Test Unit for Differential Automatic Switches SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. IAD01. 1-pole+neutral Differential Automatic Switch, 6A, 30mA, class A. CAR04. Variable Resistive Load, 150 ohm, 500W. PRACTICAL POSSIBILITIES 1.- To simulate a fault to earth and to test if the differential breaks. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AE5. Relay Control Station SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. REL23. Overcurrent Relay and Fault to Earth. CON01. 3-pole Contactor (24Vac). TRA10. Current Transformer 25/5A. CAR18. Aerial Line Model. PRACTICAL POSSIBILITIES 1.- To connect the transformers to line. 2.- To connect the protection relay. 3.- To simulate a line fault and the relay will trip the circuit breaker. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AE6. Energy Counters Control Station SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR01. Fixed Resistive Load, 150 ohm, 500 W. TRA04. 3-Phase Power Transformer 380/220V, 630VA. TRA10. Current Transformer 25/5A. MED72. Energy Counter. PRACTICAL POSSIBILITIES 1.- Assembly of the voltage and current transformers. 2.- To measure the energy consumed by the load with the energy counter. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/AE6.pdf AE7. Multi-Functional Electrical Protection Station SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR08. 3-phase Variable Resistive Load (custom made). CAR11. 3-phase Capacitive Load. CON01. 3-pole Contactor (24Vac). REL22. Multi-function Protection Relay ( software included). TRA04. 3-Phase Power Transformer 380/220V, 630VA. CAR14. 3-Phase Inductive Load. TRA10. Current Transformer 25/5A. PRACTICAL POSSIBILITIES 1.- Assembly of the station with the relay. 2.- To simulate faults in the line. 3.- To simulate under and/or overvoltage, changing the line parameters. 4.- To check if the relay trips the contactor. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf AE8. Power & Torque Measurements of Electrical Motors SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. ALI03. AC Auxiliary Power Supply (24Vac). CON02. 3-pole Contactor (220Vac). PUL11. 2 Double Push-Buttons (230Vac). REL08. Time Electronic Relay against Overcurrents (0.3-1.5A). MED60. Network Analyzer. VAR02. Motor (EMT7) (squirrel cage). FREND. Dynamo Brake. TECNEL/T. Tachodynamo. More information in: www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf Page 44 PRACTICAL POSSIBILITIES 1.- Assembly of the set and to start the motor and dynamo. 2.- To change the dynamo current and to measure both the power and the torque of the motor. 3.- To obtain the efficiency curve. 4.1- Basic Electricity (continuation) LIELBA. Electrical Installations Integrated Laboratory: (continuation) 2 Applications (continuation) Energy Installations (continuation) AE9. Directional Relay: Earth Fault Detection. Directional Power Flow Detection. Reactive Power Flow Detection SPECIFICATIONS SUMMARY Included Modules: ALI01. Industrial Main Power Supply. CAR08. 3-Phase Variable Resistive Load (custom made). CON01. 3-Pole Contactor (24Vac). CAR11. 3-Phase Capacitive Load. TRA04. 3-Phase Power Transformer 380/220V, 630VA. REL20. 1-Phase Directional Relay. CAR14. 3-Phase Inductive Load. TRA10. Current Transformer 25/5A. PRACTICAL POSSIBILITIES 1.2.3.4.- Assembly of the set. Directional relay tripping test, in a case of an earth fault. To test the tripping when power flows in the opposite direction. To test the tripping when the reactive power is over or under certain limit. More information in: http://www.edibon.com/products/ catalogues/en/units/electricity/basic/LIELBA.pdf Software CAI. Computer Aided Instruction Software System: With no physical connection between application/ module and computer, this complete package consists on an Instructor Software (INS/SOF) totally integrated with the Student/Application Software (A.../SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. These, on the other hand, get a virtual instructor who helps them to deal with all the information on the subject of study. + Application (several modules) Instructor Software Student/Application Software With the INS/SOF. Classroom Management Software Package (Instructor Software), the Teacher has a whole range of options, among them: - Organize Students by Classes and Groups. - Create easily new entries or delete them. - Create data bases with student information. - Analyze results and make statistical comparisons. - Print reports. - Develop own examinations. - Detect student’s progress and difficulties. ...and many other facilities. The Instructor Software is the same for all the applications, and working in network configuration, allows controlling all the students in the classroom. A.../SOF. Computer Aided Instruction Software Packages (Student/Application Software). It explains how to use the applications, run the experiments and what to do at any moment. Each application has its own Student Software package. - The options are presented by pull-down menus and pop-up windows. - Each Software Package contains: Theory: that gives the student the theoretical background for a total understanding of the studied subject. Exercises: divided by thematic areas and chapters to check out that the theory has been understood. Guided Practices: presents several practices to be done, alongside the applications, showing how to complete the exercises and practices. Exams: set of questions presented to test the obtained knowledge. Available Student/Applications Software Packages: ! Domestic Electrical Installations: AD1A/SOF. Robbery alarm Station. AD3A/SOF. Fire alarm station. AD5/SOF. Temporization of stairs. AD6A/SOF. L u m i n o s i t y c o n t r o l station. AD8/SOF. Blinds activator. AD9A/SOF. Heating control station. AD11A/SOF. Network analyzer. AD13/SOF. A u d i o d o o r e n t r y system. AD14/SOF. Audio and video door entry system. AD15A/SOF. Position control station. AD17A/SOF.Photoelectric control position station. AD24/SOF. Position Switch. AD19A/SOF.Sound station. AD22/SOF. Flooding control station. AD23/SOF. Wireless basic control station (RF). AD25A/SOF.Control station for domestic electric services through the telephone. AD28A/SOF.Integral control station of domesticelectric systems. AD30/SOF. Gas control station. AD31/SOF. Movement and sound detection and control. AD32/SOF. 24 Vac / 12 Vdc circuits analyzer. AD33/SOF. I n s t a l l a t i o n s f a u l t s simulator. Industrial Electrical Installations: AI1/SOF. Star-delta starter. AI2/SOF. Starter through autotransformer. AI3/SOF. Speed commutator for Dahlander motor. AI4/SOF. Starter-inverter. AI5/SOF. AC wound rotor motor starter. AI6/SOF. DC motor starter. AI7/SOF. A u t o m a t i c c h a n g e o f speed of a Dahlander motor with change of direction. AI8/SOF. R e a c t i v e p o w e r c o m pensation (Power factor correction). AI9/SOF. Pe o p l e s a f e t y a g a i n s t indirect electrical c o n t a c t s inTT neutral regimen. AI10/SOF. People safety against indirect electrical contacts in TN neutral regimen. AI11/SOF. People safety against indirect electrical contacts in IT neutral regimen. AI12/SOF. Modular Trainer(AC motors). AI13/SOF. M o d u l a r Tr a i n e r f o r Electrotecnics. ! Energy Installations: AE1/SOF. Aerial line model. AE2/SOF. Reactive energy control and compensation. AE3/SOF. Test unit for magneto-thermal automaticswitches. AE4/SOF. Test unit for differential automatic switches. AE5/SOF. Relay control station. AE6/SOF. Energy counters control station. AE7/SOF. Multi-functional electrical protection station. AE8/SOF. Power & torque measurements of electrical motors. AE9/SOF. Directional Relay: Earth fault detection. Directional power flow detection. Reactive power flow detection. More information in: www.edibon.com/products/catalogues/en/units/electricity/basic/LIELBA.pdf Page 45 www.edibon.com 4.- Electricity 3 4.1- Basic Electricity LIELBA. Electrical Installations Integrated Laboratory: (continuation) (continuation) Data Acquisition 4 Connections points Data acquisition software (MUAD/SOF) 3 4 “n” Application Electric power interface box (EPIB) Cable to computer (DAB) Cables to interface 2 MUAD. Power Data Acquisition System Data acquisition board 1 4 Student post MUAD is the perfect link between the applications/modules and the PC. MUAD is a continuous data acquisition system with virtual instrumentation, that measures, analyzes and represents the parameters involved in the process. MUAD allows voltage and current acquisition and measurement, data processing, frequency spectrum and all the functions of a digital oscilloscope. We easily connect the Electric Power Interface Box (EPIB) to the application/module with the supplied cables (there are several connection points placed for it). The EPIB is connected to the PC through the Data Acquisition Board (DAB), and by using the Data Acquisition with Virtual Instrumentation Software, the student can get results from the undertaken experiment/practice, see them on the screen and work with them. The MUAD system allows voltage and current measurement and acquisition, data processing, frequency spectrum and the functions of a digital oscilloscope. 4.- Electricity This MUAD System includes EPIB + DAB + MUAD/SOF: 1)Hardware : 1.1) EPIB. Electric power interface box ( dimensions: 300 x 120 x 180 mm. approx.): Interface that carries out the conditioning of the diverse signals that can be acquired in a process, for their later treatment and visualisation. In the front panel, the elements are separated in two parts: left-hand part to VOLTAGE sensors, and right-hand part corresponds with CURRENT sensors. Analog Input Channels: 8 analog input channels. Sampling range: 250 KSPS (Kilo samples per second). 4 Tension sensors AC/DC, 400V. 4 Current sensors. 1.2) DAB. Data acquisition board : PCI Data acquisition board (National Instruments) to be placed in a computer slot. Bus PCI. Analog input: Number of channels= 16 single-ended or 8 differential. Resolution=16 bits, 1 in 65536. Sampling rate up to: 250 KSPS (Kilo samples per second). Analog output: Number of channels=2. Resolution=16 bits, 1 in 65536. Digital Input/Output: Number channels=24inputs/outputs. Timing: Counter/timers=2. EPIB DAB 2) MUAD/SOF. Data acquisition software : Data Acquisition Software with Graphic Representation: Amicable graphical frame. Compatible with actual Windows operating systems. Configurable software allowing the representation of temporal evolution of the different signals. Visualization of a tension of the circuits on the computer screen. Sampling velocity up to 250 KSPS. (Kilo samples per second) guaranteed. More information in: www.edibon.com/products/catalogues/en/units/electricity/basic/LIELBA.pdf Page 46 MUAD/SOF issue:01/11 ENERGY: MODULAR POWER SYSTEM SIMULATOR. BASIC MODULE Ref: 0510 ITEM 1 1 / 2 REFERENCE MPSSC DESCRIPTION QTY. ERP-PD. ERP-PDF. ERP-MF MODULAR POWER SYSTEM SIMULATOR WITH SCADA CONTROL SYSTEM, FORMED BY: SCADA CONTROL SYSTEM BASIC FRAME GENERATION GROUP AUTOMATIC VOLTAGE REGULATOR AC MOTORS SPEED CONTROLLER STEP-UP TRANSFORMER STEP-DOWN TRANSFORMER TRANSMISSION LINES SIMULATION UNIT ENERGY CONSUMPTION MODULE BUSBAR MODEL 1 (GENERATION) BUSBAR MODEL 2 (TRANSPORT) BUSBAR MODEL 3 (COUPLING) BUSBAR MODEL 4 (CONSUMPTION) BUSBAR MODEL 5 (TRANSPORT) INDUSTRIAL MAIN POWER SUPPLY. SYNCHRONISMS MODULE GENERATOR PROTECTION MODULE GENERATORS PROTECTION AND CONTROL DEVICE UNIT DISTANCE PROTECTION RELAY UNIT DIFFERENTIAL PROTECTION RELAY UNIT FAULT INJECTION MODULE 1 1 1 2 0510PARTS COMPONENTS AND SPARE PARTS 1 3 0510PA COMPLEMENTARY ITEM 1 4 0510IYPM INSTALLATION AND STARTING-UP 1 5 0510CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0510TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0510MANU DOCUMENTATION AND MANUALS 1 SCADA BASB EGMG/P AVR/P VVCA/MP TRANS/3A TRANS/3B AE1. AE11 BUS01 BUS02 BUS03 BUS04 BUS05 ALI01 IND05 INX20/P ERP-PGC 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Ref: 0510 2 / 2 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages Modular Power System Simulator with SCADA Control System MPSSC Technical Teaching Equipment SCADA GENERAL DESCRIPTION The “MPSSC” is a modular Power System Simulator with SCADA Control System, specially designed for Technicians at Technical and Vocational level. The simulator will include the main parts of a Power System as: ! Generation. ! Transformation. ! Transport. ! Distribution. ! Consumption. It will include important and key elements that play a very important roll in a Power System control and protection, as: - Automatic voltage regulator. - Automatic frequency control. - All the main protection relays involved. - Automatic and Manual synchronization. The simulator includes the following modules: - SCADA Control System. - EGMG/P. Generation Group. - AVR/P. Automatic Voltage Regulator. - VVCA/MP. AC Motors Speed Controller. - TRANS/3A. Step-up Transformer. - TRANS/3B. Step-down Transformer. - AE1. Transmission Lines Simulation Unit. - AE11. Energy Consumption Module. - BUS01. Busbar model 1 (Generation). - BUS02. Busbar model 2 (Transport). - BUS05. Busbar model 5 (Transport). - BUS03. Busbar model 3 (Coupling). - BUS04. Busbar model 4 (Consumption). - ALI01. Power Supply. - IND05. Synchronims Module. - INX20/P. Generator Protection Module. - ERP-PGC. Generators Protection and Control Device Unit. - ERP-PD. Distance Protection Relay Unit. - ERP-PDF. Differential Protection Relay Unit. - ERP-MF. Fault Injection Module. Worlddidac Member ISO 9000: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) Page 1 Certificates ISO 14000 and ECO-Management and Audit Scheme (environmental management) Worlddidac Quality Charter Certificate (Worlddidac Member) MODULES IN DETAIL SCADA SCADA Control System Generation Transport/Lines Transformation Consumption TRANS/3A. Step-up Transformer EGMG/P. Generation Group AE1. Transmission Lines Simulation Unit AE11. Energy Consumption Module TRANS/3B. Step-down Transformer AVR/P. Automatic Voltage Regulator VVCA/MP. AC Motors Speed Controller Control and Protections Busbars -ALI01. -INX20/P. -IND05. -BUS01. Power Supply. Generator Protection Module. Synchronims Module. Busbar model 1 (Generation). -BUS02. -BUS05. -BUS03. -BUS04. Busbar model 2 (Transport). Busbar model 5 (Transport). Busbar model 3 (Coupling). Busbar model 4 (Consumption). ERP-PGC. Generators Protection and Control Device Unit ERP-PD. Distance Protection Relay Unit ERP-PDF. Differential Protection Relay Unit Faults ERP-MF. Fault Injection Module Page 2 www.edibon.com SCADA Control System SPECIFICATIONS SCADA is an industry-standard supervisory control and data acquisition (SCADA) software for realistic experience of power system control. For use with MPSSC Simulator to increase students´ understanding of power systems. It can connect to multiple generation systems for remote control and supervision of local generation and distributed generation. It includes alarms and logs data for detailed analysis of MPSSC during stable and transient operation. It communicates with programmable logic controllers (PLCs), numerical protection relays, automatic voltage regulators and prime-mover simulation device of the Power System Simulator to control and collect information from the power system. Includes high performance computer with integrated communication interface to exchange information with all devices. Remotely controls the generator and prime-mover of the MPSSC Simulator in different power system operation control methods (frequency control, voltage control, active power control, reactive power control, power factor control, generators load exchange). The SCADA connects to MPSSC to train students in supervision and control of power systems. The package includes industrial-standard SCADA software, a computer, colour printer and communications hardware. EDIBON supplies the software already installed on the computer. The software does several jobs, including remote control and data display and logging. It includes programs written by EDIBON to match experiments which students have done directly with the MPSSC Simulator. The software´s on-screen display or ´user interface´shows real-time data and mimics the circuit-breakers (opening and closing). It also mimics the adjustment of the loads and any faults applied by the user. Other screens give details about the settings and data collected at each protection relay or instrument on the simulator. Students select the correct screen for the experiment they want to perform. They then use the computer to close circuit-breakers, set and adjust any loads and connect the grid supply (or start the generator) by mean of touch screens, in others words, they configure the topology of the Simulator. The generators synchronization can be performed in manual and automatic mode with the help of SCADA. Students can use the software to log data from the simulator and analyse it, compare conditions before and after faults, and see the effects of faults. They can use this information to predict power system problems and change the power system protection to prevent future problems. The software includes the experiments already given with the MPSSC Simulator. contiue... Page 3 www.edibon.com SCADA Control System (continuation) SPECIFICATIONS The experiments include: - Generator characteristics and performance. - Transformers. - Transmission, distribution and consumption. - Power system protection. - Power system operation and control in different modes. - Power flow control. - etc. SCADA allows the control and supervision of the operations related to the generation, transformation, transmission and distribution of the electrical energy made by the MPSSC Simulator. Through a sophisticated human-machine interface, executed in a computer, it is possible to monitor and control a lot of events and alarms as well as analyse, display and control the information acquired from all Programmable Logic Controllers (PLCs), Automatic Voltage Regulators (AVRs), protection relays and prime mover simulation device. SCADA system is connected to the PLCs communication networks, protection relays and the rest of the units of the MPSSC Simulator, allowing the data acquisition and control in real time from all the elements of the MPSSC Simulator. The acquired data are stored for their future analysis or they are directly sent to screens connected to the computer as a visual information. The objective of the SCADA developed architecture is centralising and automating all the control tasks, monitoring, protection and data acquisition of the MPSSC Simulator is operated similar to local or central load dispatch center of Real Electrical Power System. The equipments connected to the SCADA I make one or some of the following functions: 1.- Respond to the commands of the control computer, in order to close or open all the circuit breaker contacts, power isolator and the rest of the equipments that conform the topology of the Power System Simulator. 2.- Transmit to SCADA the ON/OFF state of the electrical equipment that conform the Simulated Electrical Power System. 3.- Vary all the set points of the controlled parameters, for example, the frequency control, active power, reactive power, power factor and voltage control set point. 4.- Measurement and management of all the acquired electrical parameters in different nodes and points of the simulated power system. 5.- Protection of the electrical circuits and the equipments that conform the MPSSC Simulator. SCADA allows making a control, supervision and data acquisition in a centralised and remote way, simulating a central generation dispatch center. With help of SCADA, students can observe the real time state of the electrical equipment of the MPSSC by means of graphical and state screens. With SCADA, the operator of the electrical power system can monitor its state and consequently, it can act and make decisions about how to operate in different conditions. For example, when there is a sound or visual alarm, the operator can see what is happening in a SCADA screen, because the monitoring system includes an alarm sequences and events list of all the equipment operation, recordered throughout the practice period and can done, reports about a determined operation or about the complete practice. Another SCADA facility is that it allows visualise in a central way all the instrumentation of the MPSSC. Simulator through several screens with digital and analogical virtual instruments. In the MPSSC. Simulator, several multifunctional and numeric protection relays are used, because the study of the electrical protections is an essential point for a electrical power system. The protection relays include measurement, communication and programmable logic possibilities to done functions of monitories and control of the equipment that are protecting. Thanks to these facilities, the protection functions are incorporated and managed from SCADA, making the teaching of this subject easier in a automated and centralised way, because the students can communicate with each protection relay and managed it remotely. Page 4 www.edibon.com SCADA Control System (continuation) Examples of some possibilities Page 5 www.edibon.com ALI01. Power Supply SPECIFICATIONS This module has the followings elements: One three-phase power supply output connector. One three-phase power supply output with red, yellow and green connectors. Two single-phase power supply output. One single-phase standard type power supply output. Ground terminal. One security key. One emergency stop switch. Module state indicators. A removable key 6 with two positions (ON and OFF) acts as main switch. EGMG/P. Generation Group SPECIFICATIONS This group has the followings elements: 1.One three-phase AC squirrel cage induction motor acting as generation prime mover. 2.One three-phase Synchronous generator with DC field excitation. The induction motor is controlled from the VVCA/MP. AC Motors Speed Controller. INX20/P. Generator Protection Module SPECIFICATIONS Page 6 www.edibon.com VVCA/MP. AC Motors Speed Controller SPECIFICATIONS The VVCA/MP is an AC motor speed regulator. The numerous inputs and outputs allow you to use the VVCA/MP for power supply standard asynchronous ac motor for simulation of prime mover of generation system. Each part of the VVCA/MP is correctly identified in order to facilitate the operation and fast identification. Elements of the AVR/P: Ground protection connector. Three-Phase power output supply connectors. Control enable/disable switch. Remote/Local mode switch. Local control set-point slider. Input/Output ERP-PGC signal connector. Input/Output AVR signal connector. Power supply Switch. The capacity range of VVCA/MP is for 3 ph 400 V supply from 0.4 kW to 7 kW. The overload capacity of VVCA/MP is 150% for 1 min and 200% for 3s (in High Duty mode). The inverters with capacities of 5.5 kW and above can be used in dual rating; this means that the same inverter can be used for next higher capacity (in Low Duty mode). For example a 5.5 kW inverter can be used for a 7.5 kW motor; in this case the overload is 120% for 1 min. The braking transistor is included as standard. The braking resistor is included as standard up to 7.5 kW units. The main features of VVCA/MP are: Safety enables input (compliant to EN954-1 category 3). Built-in EMC filter for all capacities (compliant to EN 61800-3, category C3). Sensorless vector control mode (100% torque at 0 Hz). Advanced PID functions (dancer control). Brake control function. Logic gates for logic combination of input and output functions and delay timer (10steps). Positioning function (when encoder option is used). 3 slots for 3 different options at the same time (encoder, fieldbus, I/O expansion). Removable control terminals (cage clamp type). AVR/P. Automatic Voltage Regulator SPECIFICATIONS The AVR/P is an Automatic Voltage Regulator that works in conjunction with the ERP-PGC. Generators Protection and Control Device Unit. The numerous inputs and outputs allow you to use the AVR/P for voltage, reactive power and power factor regulation of generation system. Each part of the AVR/P is correctly identified in order to facilitate the operation and fast identification. Elements of the AVR/P: Ground protection connector. Generator output voltage measurement connectors. Generator Field excitation output supply connectors. Voltage Control enable/disable switch. Remote/Local mode switch. Input/Output signal connector. Local control set-point slider. Serial Port connector( Software HMI is optional product). Power supply Switch. The AVR/P is an automatic voltage regulator of the latest design for synchronous generators and synchronous motors. The unit contains the most advanced microprocessor technology together with IGBT semiconductor technology (Insulated Gate Bipolar Transistor). This advanced-design automatic voltage regulator is used for the excitation of indirectly excited synchronous machines. This unit is only suitable for this one area of application. The regulator can also be switched over to function as a reactive power, power factor and field current regulator. Page 7 www.edibon.com TRANS/3A. Step-up Transformer SPECIFICATIONS Three-phase power transformer with group connection YyN0, 400/400V, 2kVA, 50-60Hz. This unit simulates the STEP-UP transformer located in the transmission substation. TRANS/3B. Step-down Transformer SPECIFICATIONS Three-phase power transformer with group connection YyN0, 400/230V, 2kVA, 50-60Hz. This unit simulates the STEP-DOWN transformer located in the distribution substation. IND05. Synchronims Module SPECIFICATIONS This module has the followings elements: Phase Synchronization Lamps. Phase RST sequences test connectors. Page 8 www.edibon.com Busbars BUS01. Busbar model 1 (Generation) BUS02. Busbar model 2 (Transport) BUS05. Busbar model 5 (Transport) BUS03. Busbar model 3 (Coupling) BUS04. Busbar model 4 (Consumption) SPECIFICATIONS The finality of these modules is to represent the generation, transmission, distribution and subtransmission substations busbars and it included the main commutation elements as power circuit breaker, isolating switches, double busbar. With the aid of these modules is possible to coupling or decoupling all necessary elements of the power system simulator. Basically the busbars modules have similar elements, as: - Input/Outputs double BusBar power connectors. - Single-phase power supply input. - 89L-1 and 89L-2 isolators open/close selectors. - 52L circuit breaker open/close selector. - 89L-3 isolator open/close selector. - Manual/Remote operation enable switch. - Input/Output signals control connector. Page 9 www.edibon.com AE1. Transmission Lines Simulation Unit SPECIFICATIONS This unit represents basic concepts of the Electric Energy high-voltage three-phase transmission lines operation. It simulates a value modifying concentrated parameter line that allows different configurations and consists on three conductorline (R, S, T) and a Neutral or return line (N). Each of the phases is represented, following the concentrated parameters theoretical model, through a resistance series association and inductance, along with a parallel association between each one of them in a capacitance effect. A way to reduce the earth short circuit current is to have impedance in the neutral-to-ground connections. This impedance has no repercussion in the normal functioning of the network but they introduce a repercussion in the increase of 3x Zo (impedance on the zero sequence component), which reduces the short circuit current. The return line is simulated through small value impedance that has a resistive-indicative characteristic. To simplify the effect, being a despicable inductance, it will be simulated with a pure 10 resistance. The phases have two terminals at the input and two at the output, and they are connected at the interior. Through one of them the module will be supplied. Through the last one the natural circuit will continue to the load module, the bar module, the transformer, etc. The two terminals left en every phase is left for assembly of protection relay or other parallel configurations. The supply of this unit will be done through line terminals (R, S, and T) and the neutral (N) through a 400V three-phase supply and it will be controlled by an interrupter-circuit breaker of 4 poles placed between the supply and the lines module. In the phases we can distinguish different resistance and inductance values, being able to simulate different length transport lines. The resistive part is formed by two resistance values of 15 and 33 obtaining two additions resistive values of 10.31 and 48 . , with the possibility of making parallel-series connections between them, The inductive part consists on a multistage coil of despicable resistance. In which it is possible to choose one of the following values: 33 mH, 78 mH, 140 mH, 193 mH, 236 mH The capacitive part will be divided into capacitance between conductors and capacitance between line and ground. The capacitance between conductors is simulated with a pair of capacitors at the beginning and at the end of the line with different values: 0.5 F and 1 F for each conductor. The capacitance between conductor and ground is 1 F and 2 F, also at the beginning and at the end of the line. With all this values it is possible to simulate a great number of line configurations, beginning with different line distances with different types of conductor, through the unbalanced lines with different conductors groups (Simplex, Duplex, Triplex and Cuadruplex). At the same time it is possible to simulate transient state with different short-circuits injection using a fault injection module. The unit is protected with a grounding connection that comes from the metallic caging and that is accessible through a terminal in the front of the module. Page 10 www.edibon.com AE11. Energy Consumption Module SPECIFICATIONS With this module is possible to simulate any proper consumption in the power system or we can test any element of the power system separately under different load conditions. It has differentiated part on resistive, inductive and capacitive zones and it allows all types of combinations between them, so we can simulate pure resistive, inductive and capacitive load as well as different series-parallel combination of them. Metallic box. Diagram in the front panel. Variable resistive loads: 3 x [ 150 W (500 W) ]. Fixed resistive loads: 3 x [ 150 W (500 W) + 150 W (500 W) ]. Inductive loads: 6 x [ 0, 33, 78, 140, 193, 236 mH ].(2 A Max.). Capacitive loads: 3 x [ 3 x 3.5 mF ] + 3 x [ 3 x 7 mF ] + 3 x [ 3 x 14 mF ]. Ground connector. Page 11 www.edibon.com ERP-PGC. Generators Protection and Control Device Unit SPECIFICATIONS The ERP-PGC is a control unit for engine-generator simulator system. The numerous inputs and outputs, along with a modular software structure, allow you to use the ERP-PGC for a wide range of applications with only a single part number. This includes stand-by, AMF (automatic mains failure), peak shaving, import-export or distributed generation, among others. Also the ERP-PGC is compatible for island, island parallel, mains parallel and multiple unit mains parallel operations. Each part of the ERP-PGC is correctly identified in order to facilitate the operation and fast identification. All the adjustments are executed with the management software from a PC. Elements of the ERP-PGC: Power input/output connectors. Multifunction control and protection device. Generator group control inputs and outputs connector. Generator rotor to ground protection Relay. Isolated operation connector(52GT state and 52G trip command). Functions: Prime mover control. Engine, mains and generator protection. Engine data measurement : Oil pressure and temperature, coolant temperature, battery voltage, speed, service hours, etc. Generator and mains data measurement: Voltage, current, power, kVar, kW, kWh, etc. Load/Var sharing for up to 32 participants. Load-dependent start/stop. Automatic, Manual, and Stop operating modes. Application modes: 1.No CB (Circuit Breaker) operation. 2.Open GCB (Generator Circuit Breaker). 3.Open/close GCB. 4.Open/close GCB/MCB (Generator CB/Main Circuit Breaker). Logics Manager for processing measured values, discrete inputs, and internal states. Engine starter sequencing. Alarm display with circuit breaker trip and engine shutdown. AMF (automatic mains failure) standby genset control, with automatic engine start on mains failure detection and open transition breaker control. Critical mode operation. Synchronizing (phase matching and slip frequency) and mains parallel operation. External frequency, voltage, power, and power factor set point control via analogue input or interface. FIFO (First Input First Output) event history with 300 entries. ECU data visualization via J1939. CAN bus communication to engine controllers, plant management systems, expansion boards, and Toolkit configuration and visualization software. RS-485 Modbus communication with plant management systems. RS-232 Modbus communication with plant management systems. Page 12 www.edibon.com ERP-PD. Distance Protection Relay Unit SPECIFICATIONS The ERP-PD is a transmission line protection device. The numerous inputs and outputs, along with a modular software structure, allow you to use the ERP-PD for study and analyze the performance of different transmission line protection system. Each part of the ERP-PD is correctly identified in order to facilitate the operation and fast identification. All the adjustments are executed with the management software from a PC. Elements of the ERP-PD: Power input/output connectors. Protection device. Outputs connector for trip command. Functions: Protection:Optimize line protection with a system of sensitive, secure, and dependable three-pole trip relay elements. Monitoring: Simplify fault and system disturbance analyses with event reports and Sequential Events Recorder. Fault Locator: Isolate line problems, and restore service faster. Automation. Remote communications capabilities and elimination of external control elements. ERP-PDF. Differential Protection Relay Unit SPECIFICATIONS The ERP-PDF is a differential protection device. The numerous inputs and outputs, along with a modular software structure, allow you to use the ERP-PDF for study and analyze the performance of different differential protection system. Each part of the ERP-PDF is correctly identified in order to facilitate the operation and fast identification. All the adjustments are executed with the management software from a PC. Elements of the ERP-PDF: Power input/output connectors. Protection device. Outputs connector for trip command. Functions: It provides current differential protection plus two complete groups of overcurrent elements in one compact package. The relay measures high- and low-side currents, differential operate and restraint quantities, as well as second and fifth harmonics of the applied currents. The unit provides two optoisolated inputs, four programmable output contacts, and one alarm output contact. This relay can protect two-winding power transformers, reactors, generators, large motors, and other two-terminal power apparatus. The relay settings permit you to use wye or delta connected high- and low-side current transformers. The relay compensates for various equipment and CT connections to derive appropriate differential operating quantities. The ERP-PDF provides three differential elements with dual slope characteristics. The second slope provides security against CT saturation for heavy through faults. Page 13 www.edibon.com ERP-MF. Fault Injection Module SPECIFICATIONS The fault injection module have the possibility to inject different kind of short-circuits, in any point of the power system simulator including line module, directly or through a pure resistive element. Employing this element we can analyze line performance during transient state as well as analyze the line protection elements functionality. The short-circuit injection possibility are: Three-pole short-circuit. Two-pole short-circuit. Two-pole-ground short-circuit. Single-pole-ground short-circuit. Page 14 www.edibon.com issue:01/11 ENERGY: MODULAR POWER SIMULATOR (ESN) Ref: 0511 ITEM 1 / 2 REFERENCE DESCRIPTION QTY. 1 MPPSC/ESN SCADA NET SYSTEM (ESN) FOR MODULAR POWER SYSTEM SIMULATOR WITH SCADA CONTROL SYSTEM (30 STUDENTS WORKING "SIMULTANEOUSLY") 1 2 0520PARTS COMPONENTS AND SPARE PARTS 1 3 0520PA COMPLEMENTARY ITEM 1 4 0520IYPM INSTALLATION AND STARTING-UP 1 5 0520CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0520TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0520MANU DOCUMENTATION AND MANUALS 1 Ref: 0511 2 / 2 SPECIFICATIONS: -Mini-ESN system main possibilities: . 30 students “simultaneously” work. . Any student can work simultaneously doing “Real Time Control”. . The teacher "can see" in his computer what any student is doing in any computer at any time. . The unit and system can be visualised simultaneously in "n" screens. This system is common for any EDIBON Computer Control unit, but need individual Software Applications for each particular unit. Notes: 1) Multipost option: With this module 30 students working simulatenously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages Modular Power System Simulator with SCADA Control System MPSSC Technical Teaching Equipment SCADA GENERAL DESCRIPTION The “MPSSC” is a modular Power System Simulator with SCADA Control System, specially designed for Technicians at Technical and Vocational level. The simulator will include the main parts of a Power System as: ! Generation. ! Transformation. ! Transport. ! Distribution. ! Consumption. It will include important and key elements that play a very important roll in a Power System control and protection, as: - Automatic voltage regulator. - Automatic frequency control. - All the main protection relays involved. - Automatic and Manual synchronization. The simulator includes the following modules: - SCADA Control System. - EGMG/P. Generation Group. - AVR/P. Automatic Voltage Regulator. - VVCA/MP. AC Motors Speed Controller. - TRANS/3A. Step-up Transformer. - TRANS/3B. Step-down Transformer. - AE1. Transmission Lines Simulation Unit. - AE11. Energy Consumption Module. - BUS01. Busbar model 1 (Generation). - BUS02. Busbar model 2 (Transport). - BUS05. Busbar model 5 (Transport). - BUS03. Busbar model 3 (Coupling). - BUS04. Busbar model 4 (Consumption). - ALI01. Power Supply. - IND05. Synchronims Module. - INX20/P. Generator Protection Module. - ERP-PGC. Generators Protection and Control Device Unit. - ERP-PD. Distance Protection Relay Unit. - ERP-PDF. Differential Protection Relay Unit. - ERP-MF. Fault Injection Module. Worlddidac Member ISO 9000: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) Page 1 Certificates ISO 14000 and ECO-Management and Audit Scheme (environmental management) Worlddidac Quality Charter Certificate (Worlddidac Member) MODULES IN DETAIL SCADA SCADA Control System Generation Transport/Lines Transformation Consumption TRANS/3A. Step-up Transformer EGMG/P. Generation Group AE1. Transmission Lines Simulation Unit AE11. Energy Consumption Module TRANS/3B. Step-down Transformer AVR/P. Automatic Voltage Regulator VVCA/MP. AC Motors Speed Controller Control and Protections Busbars -ALI01. -INX20/P. -IND05. -BUS01. Power Supply. Generator Protection Module. Synchronims Module. Busbar model 1 (Generation). -BUS02. -BUS05. -BUS03. -BUS04. Busbar model 2 (Transport). Busbar model 5 (Transport). Busbar model 3 (Coupling). Busbar model 4 (Consumption). ERP-PGC. Generators Protection and Control Device Unit ERP-PD. Distance Protection Relay Unit ERP-PDF. Differential Protection Relay Unit Faults ERP-MF. Fault Injection Module Page 2 www.edibon.com SCADA Control System SPECIFICATIONS SCADA is an industry-standard supervisory control and data acquisition (SCADA) software for realistic experience of power system control. For use with MPSSC Simulator to increase students´ understanding of power systems. It can connect to multiple generation systems for remote control and supervision of local generation and distributed generation. It includes alarms and logs data for detailed analysis of MPSSC during stable and transient operation. It communicates with programmable logic controllers (PLCs), numerical protection relays, automatic voltage regulators and prime-mover simulation device of the Power System Simulator to control and collect information from the power system. Includes high performance computer with integrated communication interface to exchange information with all devices. Remotely controls the generator and prime-mover of the MPSSC Simulator in different power system operation control methods (frequency control, voltage control, active power control, reactive power control, power factor control, generators load exchange). The SCADA connects to MPSSC to train students in supervision and control of power systems. The package includes industrial-standard SCADA software, a computer, colour printer and communications hardware. EDIBON supplies the software already installed on the computer. The software does several jobs, including remote control and data display and logging. It includes programs written by EDIBON to match experiments which students have done directly with the MPSSC Simulator. The software´s on-screen display or ´user interface´shows real-time data and mimics the circuit-breakers (opening and closing). It also mimics the adjustment of the loads and any faults applied by the user. Other screens give details about the settings and data collected at each protection relay or instrument on the simulator. Students select the correct screen for the experiment they want to perform. They then use the computer to close circuit-breakers, set and adjust any loads and connect the grid supply (or start the generator) by mean of touch screens, in others words, they configure the topology of the Simulator. The generators synchronization can be performed in manual and automatic mode with the help of SCADA. Students can use the software to log data from the simulator and analyse it, compare conditions before and after faults, and see the effects of faults. They can use this information to predict power system problems and change the power system protection to prevent future problems. The software includes the experiments already given with the MPSSC Simulator. contiue... Page 3 www.edibon.com SCADA Control System (continuation) SPECIFICATIONS The experiments include: - Generator characteristics and performance. - Transformers. - Transmission, distribution and consumption. - Power system protection. - Power system operation and control in different modes. - Power flow control. - etc. SCADA allows the control and supervision of the operations related to the generation, transformation, transmission and distribution of the electrical energy made by the MPSSC Simulator. Through a sophisticated human-machine interface, executed in a computer, it is possible to monitor and control a lot of events and alarms as well as analyse, display and control the information acquired from all Programmable Logic Controllers (PLCs), Automatic Voltage Regulators (AVRs), protection relays and prime mover simulation device. SCADA system is connected to the PLCs communication networks, protection relays and the rest of the units of the MPSSC Simulator, allowing the data acquisition and control in real time from all the elements of the MPSSC Simulator. The acquired data are stored for their future analysis or they are directly sent to screens connected to the computer as a visual information. The objective of the SCADA developed architecture is centralising and automating all the control tasks, monitoring, protection and data acquisition of the MPSSC Simulator is operated similar to local or central load dispatch center of Real Electrical Power System. The equipments connected to the SCADA I make one or some of the following functions: 1.- Respond to the commands of the control computer, in order to close or open all the circuit breaker contacts, power isolator and the rest of the equipments that conform the topology of the Power System Simulator. 2.- Transmit to SCADA the ON/OFF state of the electrical equipment that conform the Simulated Electrical Power System. 3.- Vary all the set points of the controlled parameters, for example, the frequency control, active power, reactive power, power factor and voltage control set point. 4.- Measurement and management of all the acquired electrical parameters in different nodes and points of the simulated power system. 5.- Protection of the electrical circuits and the equipments that conform the MPSSC Simulator. SCADA allows making a control, supervision and data acquisition in a centralised and remote way, simulating a central generation dispatch center. With help of SCADA, students can observe the real time state of the electrical equipment of the MPSSC by means of graphical and state screens. With SCADA, the operator of the electrical power system can monitor its state and consequently, it can act and make decisions about how to operate in different conditions. For example, when there is a sound or visual alarm, the operator can see what is happening in a SCADA screen, because the monitoring system includes an alarm sequences and events list of all the equipment operation, recordered throughout the practice period and can done, reports about a determined operation or about the complete practice. Another SCADA facility is that it allows visualise in a central way all the instrumentation of the MPSSC. Simulator through several screens with digital and analogical virtual instruments. In the MPSSC. Simulator, several multifunctional and numeric protection relays are used, because the study of the electrical protections is an essential point for a electrical power system. The protection relays include measurement, communication and programmable logic possibilities to done functions of monitories and control of the equipment that are protecting. Thanks to these facilities, the protection functions are incorporated and managed from SCADA, making the teaching of this subject easier in a automated and centralised way, because the students can communicate with each protection relay and managed it remotely. Page 4 www.edibon.com SCADA Control System (continuation) Examples of some possibilities Page 5 www.edibon.com Advanced Electrical Machines Laboratory (4EMAD) List of modules and teaching units included plus Summarised Catalogues Priority 3 0600. Automation & Systems 0610: PLC Trainer Ref.:4EMAD-pre(01/11) issue:01/11 PLC TRAINER Ref: 0610 1 / 1 ITEM Ä REFERENCE DESCRIPTION QTY. 1 PLCE PLC TRAINER 1 2 0620PARTS COMPONENTS AND SPARE PARTS 1 3 0620PA COMPLEMENTARY ITEM 1 4 0620IYPM INSTALLATION AND STARTING-UP 1 5 0620CAPRO TRAINING AND BRINGING UP TO DATE OF TEACHERS 1 6 0620TD TEACHING TECHNIQUES "KNOW-HOW" 1 7 0620MANU DOCUMENTATION AND MANUALS 1 Notes: 1) Multipost option: This module has only one unit in each item, but we can recommend the number of units for 10 or 30 students working simultaneously. 2)Supply conditions: a) Technical conditions included: - Laboratories adaptation. Installation of all units supplied. Starting up for all units. Training about the exercises to be done with any unit. - Teacher training related with t and the teaching unit and the teaching techniques uses. - Technology transfer. b) Commercial conditions: - Packing. - Financing charges. - C.I.F. charges. c) Others conditions: - 8 Manuals for each EDIBON teaching unit: . . . . . . . Required services manual. Assembly and installation manual. Interface and software/control console manual. Set in operation manual. Safety norms manual. Practices manual. Maintenance manual. . Calibration manual. See Catalogues in next pages 6.2- Automatics PLC-PI. Module for the Control of Industrial Processes (for working with EDIBON Computerized Teaching Units) Always included in the supply: 2 PLC-SOF. PLC Control Software for each particular EDIBON Computerized Teaching Unit 1 Unit: PLC-PI. PLC Module for the Control of Industrial Processes (for working with EDIBON Computerized Teaching Units). SPECIFICATIONS SUMMARY Items supplied as standard PLC-PI Unit: This PLC-PI unit contains a box, with a front panel in order to manipulate the unit in a simple and easy way, the power supply and all necessary connectors and cabling and, additionally, the PLC itself with its own touch screen. We have design and supply the proper software for any particular application (for each particular EDIBON Computerized Teaching Unit). Steel box. Circuit diagram in the front panel. Front panel: Digital inputs(X) and Digital outputs (Y) block. 16 Digital inputs. 14 Digital outputs. Analog inputs block: 16 Analog inputs. Analog outputs block: 4 Analog outputs. Touch screen. Back panel: Power supply connector. Fuse 2A. RS-232 connector to PC Inside: Power supply outputs: 24 Vdc, 12 Vdc, -12 Vdc, 12 Vdc variable. Panasonic PLC: High-speed scan of 0.32msec. for a basic instruction. Program capacity of 32 Ksteps, with a sufficient comment area. Multi-point PID control. Digital inputs/outputs and analog inputs/outputs Panasonic modules. Communication RS232 wire, to computer (PC). 2 PLC-SOF. PLC Control Software: For each particular EDIBON Computerized Teaching Unit. 3 Cables and Accessories, for normal operation. 4 Manuals: This unit is supplied with 8 manuals. Dimensions (approx.) =Unit: 490 x 330 x 310 mm. Weight: 30 Kg. 1 More information in: www.edibon.com/products/catalogues/en/units/ PRACTICAL POSSIBILITIES 1.- Control of theparticular unit process through the control interface box without the computer. 2.- PID control. 3.- Visualization of all the sensors values used in the particular unit process. 4.- Calibration of all sensors included in the particular unit process. 5.- Hand on of all the actuators involved in the particular unit process. 6.- Realization of different experiments, in automatic way, without having in front the particular unit. (These experiments can be decided previously). 7.- Simulation of outside actions, in the cases do not exist hardware elements. (Example: test of complementary tanks, complementary i n d u s t r i a l environment to the process to be studied, etc). 8.- PLC hardware general use. 9.- PLC process application for the particular unit. 10.- PLC structure. 11.- P L C i n p u t s a n d o u t p u t s configuration. 12.- PLC configuration possibilities. 13.- PLC program languages. 14.- PLC different programming standard languages (ladder diagram (LD), structured text (ST), instructions list (IL), sequential function chart (SFC), function block diagram (FBD)). 15.- N e w c o n f i g u r a t i o n a n d development of new process. 16.- Hand on an established process. 17.- To visualize and see the results and to make comparisons with the particular unit process. 18.- Possibility of creating new process in relation with the particular unit. 19.- PLC Programming Exercises. 20.- Own PLC applications in accordance with teacher and student requirements. automationsystems/plcunitoperations/PLC-PI.pdf PLCE. PLC Trainer 1 2 3 PLC Programming Software PLCE Touch Screen Programming Software Unit: PLCE. PLC Trainer PRACTICAL POSSIBILITIES SPECIFICATIONS SUMMARY Items supplied as standard PLCE. Unit: This PLCE unit contains a box, with a front panel in order to manipulate the unit in a simple and easy way, the power supply and all necessary connectors and cabling and, additionally, the PLC itself with its own touch screen. Steel box. Circuit diagram in the front panel. Front panel: Several 12V sources that can be activated through switches, 8 lever type and 8 push button type switches with their corresponding led that indicates the ON/OFF state of the source. 6 variable sources (potentiometer), 0 to 10V. 16 digital inputs. 14 digital outputs. 8 analog inputs. 4 analog outputs. ON/OF power switch. Several mass connections (GND). Touch screen. Back panel: Power supply connector. Fuse 2A. RS-232 connector to computer (PC). Inside: Power supply 100... 240V (AC). Panasonic PLC: High-speed scan of 0.32 msec for a basic instruction. Program capacity of 32 Ksteps, with a sufficient comment area. High-speed counter. Multi-point PID control. Digital inputs/outputs and analog inputs/outputs Panasonic modules. Communication RS 232 wire, to computer (PC). PC Bases Programming. 2 PLC Programming Software: Compatible with actual Windows operating systems. Several programming languages can be used: ladder diagram (LD), structured text (ST), instructions list (IL), sequential function chart (SFC), function block diagram (FBD). Variables editors, configuration, programming and documentation. To symbolize the application objects: bits, words, function blocks, inputs/outputs... Operants available: inputs and outputs (X/Y), as well as internal memory areas, internal relays, special internal relays, timers and counters, data registers, special data registers, file registers, link registers and relays. You can use either Matsushita and/or IEC addresses. There are 3 type on constants: decimal, hexadecimal and BCD. This software provides elementary and user defined data types. Matsushita Floating Point Instructions Set. Uploading of source programs from PLC possible. “Black boxing” of programs. Reuse of programs is easy. 3 PLCE Touch Screen Programming Software: Tools for Screen Creation. Plenty of functions. Screens Creation. Drawing Functions. Easy Operativity (Click and slip). Easy creation of user libraries. Printing. Easy use. Bitmaps Editor. Cables and Accessories, for normal operation. 4 5 Manuals: This unit is supplied with 8 manuals. Dimensions=490 x 330 x 310 mm. approx. Weight: 20 Kg. approx. 1 More information in: www.edibon.com/products/catalogues/en/units/ automationsystems/plcprocessemulation/PLCE.pdf Page 85 Using the PLC Programing Software: 1.- Creating applications for a PLC and loading them in the PLCE. The programs can be written in several programming languages: Ladder diagram (LD). Structured text (ST). Instructions list (IL). Sequential function chart. (SFC). Function block diagram. (FBD). 2.- Check the digital inputs and their value and how to store in the variable. 3.- Use of several inputs with the purpose of activating an output. 4.- To assign names to the contacts in the edition area. 5.- Use of all digital inputs (16) and to create a variable per digital input. 6.- Interacting with a digital output, whose value will depend on that established in a variable. 7.- How to use several digital variables and outputs. 8.- How to use analog inputs. 9.- How to use analog outputs. 10.- Use of temporizers. 11.- Logic functions implementation. 12.- Application of the instructions set and reset. 13.- Program jumps (conditional and non-conditional). 14.- Timer, counter and comparators. 15.- Use of subroutines and interruptions events. 16.- Functions library. 17.- Regulation controls. PID function. 18.- Analog Inputs/Outputs. Real Time visualization. * Some applications related to these practices are included in the supply. Using the PLCE Touch Screen Programming Software: 19.- How to create a simple application for the PLCE screen. 20.- How to commute digital outputs of the PLC through the screen. 21.- How to commute several digital outputs simultaneously. (Working with words). 22.- Writing on and reading from a data register. 23.- How to write a data register in a range of values. 24.- Switching from one screen to another. * Some applications related to these practices are included in the supply. Other practical possibilities: -It is possible to make simulations without need of any external element, causing analog inputs and/or digital ones, and to observe what happens in the outputs. -It is also possible to introduce real analog inputs (for example: the transducer value in volts of a temperature sensor) and/or digital inputs (for example: an external pulser) and to connect real actuators in the output, (for example: a pump). www.edibon.com 6.- Systems & Automatics Always included in the supply: