* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download RIC 2011
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Portable appliance testing wikipedia , lookup
Current source wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power engineering wikipedia , lookup
Single-wire earth return wikipedia , lookup
Stepper motor wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Schmitt trigger wikipedia , lookup
Power electronics wikipedia , lookup
Three-phase electric power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Distribution management system wikipedia , lookup
Power MOSFET wikipedia , lookup
Buck converter wikipedia , lookup
Electrical substation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Voltage regulator wikipedia , lookup
Rectiverter wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Alternating current wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
RIC 2011 Adequacy of Station Electric Distribution System Voltages—Degraded Voltage Protection Robert Daley Division of Reactor Safety/Region III March 9, 2011 1 Degraded Voltage A Regional Perspective 2 Inspection Identified Issues • Unacceptably long time delays - Time delay not represented in LOCA Response Time Analysis Analysis. - Potential for: - Tripping of circuit breakers powering safety related loads. - Stalling and/or damage of motors. - Incorrect reliance on automatic tap changers 3 1 Inspection Identified Issues • Unacceptably long time delays (Cont.) - Long time delays with auto DVR actuation if LOCA occurs occurs. - Inadequate for normally running safety related motors not rated for low voltages. - Potential tripping, stalling, damage. 4 Inspection Identified Issues (Cont.) • Inadequate Low Voltage settings - DVR voltage lt nott sett conservatively ti l - TS 3.8.1, AC Sources, Operability - Operating (grid) voltage inadequate to ensure offsite power is available during a LOCA - Usually tied to 27 device (undervoltage relay) reset value 5 Inspection Identified Issues (Cont.) • Inadequate Low Voltage settings (Cont.) - Low voltages at motor terminals - Low L voltages lt att MCC MCCs causing i contactor t t d dropoutt 6 2 Inspection Identified Issues (Cont.) • Peripheral Issues - Inadequately sized transformers resulting in low voltages during equipment block starts. starts - EDG voltage fluctuations during safety related motors starts. 7 Regulatory Pathway • 10 CFR 50, Appendix B, Design Control • Backfit Analysis - Compliance C li B Backfit kfit - Performed on one plant in Region III. - Safety Backfit - Safety and risk significant. - Compliance backfit issue in Region III was also preliminarily White for risk significance. 8 3