* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 3A1980
Electronic engineering wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrician wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Electrical substation wikipedia , lookup
Flexible electronics wikipedia , lookup
Rectiverter wikipedia , lookup
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Voltage optimisation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Stray voltage wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Earthing system wikipedia , lookup
Home wiring wikipedia , lookup
Alternating current wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Mains electricity wikipedia , lookup
Electrical wiring wikipedia , lookup
National Electrical Code wikipedia , lookup
Surge Protection Made Simple™ Technical Data Catalog Number Nominal voltage (UN) Nominal current at 45°C (IL) Operating temp. range Degree of protection Agency information Hazardous Voltage Will cause severe injury or death. Working on or near energized circuits poses a serious risk of electrical shock. De-energize all circuits before installing or servicing this equipment and follow all prescribed safety procedures. DATA SIGNAL APPLICATIONS BSPD5DING 5V BSPD12DING 12V BSPD24DING 24V BSPD48DING 48V 1.0A 0.75A 0.75A 0.75A BSPD5DINLHF BSPD24DINLHF 5V 24V 1.0A 1.0A Warranty -40°C to +80°C IP20 ATEX, UL, CSA, Installation Instructions See document 3A1502 at www.cooperbussmann.com/surge for details of limited warranty. Wire Connections For optimum protection, see wiring practices note on page 2. Size 0 blade driver Mounting Protected 2' Torque 3.5 Lb-In (0.4 N•m) max. A 2 1 side 4' 1'3' 4 3 2 B clic 2 1 k Use min. 10AWG (6mm2) Conductor 3 A Module Removal Circuit Diagram Use max. 14AWG (2.5mm2) conductor Use min. 10AWG (6mm2) conductor NOTE: When wiring the DIN-Rail base, observe the terminal assignemnt of the surge arrestor module according to the circuit diagram. Wire Routing Module / Base “Make-Before-Break” Schematic Protected side 1 1´ 1 1´ 2 2´ 2 2´ 3 3´ 4 4´ 3 3‘ 4 4‘ BSPD5 to 48DING 9 BSPD5 to 24DINLHF 3A1980RevA © 2012 Cooper Bussmann St. Louis, MO 63178 Publication-No. DS1537/CB; ID-No. 066949 Protected 9 Protected Protected side Protected side OK Unprotected side 1 23 4 4´ 3´2´1´ C US www.cooperbussmann.com UL Requirements Safety Instructions 1. This Surge Protective Device (SPD) is intended for ordinary indoor use on communication loop circuits that are isolated from the Public Switched Telephone Network. 2. The SPD module shall be secured to the compatible base before applying power to the communication loop. 3. The base shall be secured to a compatible DIN-Rail ground bar using the methods described in this instruction. 4. Proper grounding continuity shall be determined. 5. Please install the protector module inaccordance with the applicable requirements of the National Electrical Code®, Article 800 or other applicable local codes. 6. Screw terminal ratings with the applicable wire gauge sizes shall be noted. 7. The maximum circuit current for UL 497 B application is limited to 100mA. This Surge Protective Device (SPD) for coaxial connection may only be installed by qualified electrical personnel. All applicable national and local electrical standards and safety regulations must be observed. The SPD must be checked for external damage prior to installation. If any damage or other defects are detected, do not install the device. Catalog Number BSPD5DING BSPD12DING BSPD24DING BSPD48DING BSPD5DINLHF BSPD24DINLHF Tabulation Strike voltage in accordance with UL 497 (Protectors for Data Communication and Fire Alarm Circuits) Strike Voltage 100V / sec Strike Voltage 100V / μsec Line-to-Ground Line-to-Line Line-to-Ground Line-to-Line 6.7Vmin 8.5Vmax 13.4Vmin 17Vmax 6.7Vmin 9Vmax 13.4Vmin 18Vmax 16.5Vmin 18.7Vmax 33Vmin 37.5Vmax 16Vmin 19Vmax 33Vmin 38Vmax 35Vmin 42Vmax 70Vmin 83Vmax 35Vmin 42Vmax 70Vmin 90Vmax 59Vmin 67Vmax 72Vmin 133Vmax 59Vmin 70Vmax 118Vmin 140Vmax 70Vmin 110Vmax 7.5Vmin 11Vmax 70Vmin 550Vmax 7.5Vmin 11Vmax 70Vmin 110Vmax 36Vmin 43Vmax 70Vmin 550Vmax 36Vmin 47Vmax The installation and application of this SPD is only permitted within the limits shown and stated in these installation instructions. The SPD and the equipment connected to it can be destroyed by loads exceeding the stated values. Opening, modifying or otherwise tampering with the SPD invalidates the warranty. Wiring Practices Instruction for Surge Protective Device Use In Zone 2 Explosive Atmospheres For optimum protection please observe the following good wiring practices: 1. When installed in potentially explosive atmospheres, the Data Signal DIN Series shall be installed into an enclosure which meets the requirements of a recognized type of protection, in accordance with EN 60079-0. 2. The Data Signal DIN Series as transient suppressor. This approval applies to the following equipment types: • BSPD5DING • BSPD12DING • BSPD24DING • BSPD48DING • BSPD5DINLHF • BSPD24DINLHF • Avoid routing signal wires parallel to power wiring or cables. • Cross power and other cables at a right angle to minimize inductance or capacitance coupling. • Keep length of protected signal wires as short as possible. • Use shielded wires whenever possible. • Connect wire shields to equipotentional bonding/ground on both sides of the SPD and protected equipment. Ambient and Temperature Class: • - 40°C to +80°C, T4 DEKRA 12ATEX0254 X II 3 G Ex nA IIC T4 Gc Standards Used For: • ATEX: EN 60079-0: 2009, EN 60079-15: 2005 3A1980RevA © 2012 Cooper Bussmann St. Louis, MO 63178 Publication-No. DS1537/CB; ID-No. 066949 www.cooperbussmann.com