* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download VSP SERIES INT 191507 - DITEK Surge Protection
Electrical substation wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Portable appliance testing wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Three-phase electric power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Single-wire earth return wikipedia , lookup
Stray voltage wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Opto-isolator wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Home wiring wikipedia , lookup
Mains electricity wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Earthing system wikipedia , lookup
National Electrical Code wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
INSTALL INSTRUCTIONS DTK-VSP Series DITEK Corporation This Surge Protection Device (SPD) is a high performance device, designed to provide protection for sensitive electronic loads connected to service panels, fire panels, or where the SPD is directly connected to the electronic device. Maximum protection will only be achieved if the SPD is properly installed. Please read and follow the installation instructions carefully. INSTALLATION ONE DITEK CENTER 1720 Starkey Road Largo, FL 33771 NOTICE: This SPD should be installed by a licensed contractor in accordance with the National and Local Electrical Codes and the following instructions. APPLICATION Surge suppression for: CCTV applications using BNC connections. CATV applications using F Type connections. Antenna protection using N Type connections. INSTRUCTIONS: Caution: Measure all voltages to insure applied voltage does not exceed the voltage rating of the unit. Improper installation voids the warranty. This unit must be connected in series with the equipment to be protected. 1. Connect the incoming feed from the “Field” to the INPUT side of the DTK-VSP. 2. Connect an appropriately tipped 3’ patch cable from the DTK-VSP to the equipment to be protected to allow for reaction time of the SPD. 3. Always have one common ground per system to eliminate the possibility of a differential in ground potentials. Make sure the ground wire is as short as possible. Ground Resistance Rule: Max ground resistance is 25 ohms, 5 ohms or less is optimum. This cannot be an assumed value and must be measured to assure proper grounding. 4. For mounting, use double sided tape (supplied), or two (2) #8 screws (not supplied). DTK-VSP Series EQUIPMENT INPUT (FIELD) WIRING OUTPUT TO EQUIPMENT ALLOW 3’ FT MINIMUM IN LENGTH GROUND WIRE #14 AWG. MINIMUM Drawn By: K. Nguyen 5-17-16 Approved By: R. Mitchell 6-3-16 DITEK Technical Support Available 24/7 1-888-472-6100 www.ditekcorp.com Doc # INT-100106-001 Part No. 191507 Rev. 2