* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Lecture 1. Introduction. Nature of light, geometric optics.
Phase-contrast X-ray imaging wikipedia , lookup
Vibrational analysis with scanning probe microscopy wikipedia , lookup
Surface plasmon resonance microscopy wikipedia , lookup
Thomas Young (scientist) wikipedia , lookup
Nonlinear optics wikipedia , lookup
Photon scanning microscopy wikipedia , lookup
Magnetic circular dichroism wikipedia , lookup
Diffraction topography wikipedia , lookup
Schneider Kreuznach wikipedia , lookup
Atmospheric optics wikipedia , lookup
Ultraviolet–visible spectroscopy wikipedia , lookup
Nonimaging optics wikipedia , lookup
Dispersion staining wikipedia , lookup
Optical coherence tomography wikipedia , lookup
Image intensifier wikipedia , lookup
Anti-reflective coating wikipedia , lookup
Optical telescope wikipedia , lookup
Interferometry wikipedia , lookup
Lens (optics) wikipedia , lookup
Night vision device wikipedia , lookup
Diffraction grating wikipedia , lookup
Retroreflector wikipedia , lookup
Image stabilization wikipedia , lookup
Johan Sebastiaan Ploem wikipedia , lookup
Super-resolution microscopy wikipedia , lookup
Confocal microscopy wikipedia , lookup
Diffraction wikipedia , lookup
Optical Microscopy Lecture 1 Concepts we will discuss in this lecture: • Natures of light • Mechanism of Optical Imaging system • The Use of Lenses and the Problem of Lenses • Spatial Resolution Some Properties of Light Both lasers and white light sources used in microscopy Laser Chromatic Polarization Phase Direction White light Monochromatic vs white light 450 nm 600 nm White light contains all, or most, of the colors of the visible spectrum. Lasers are Monochromatic (very narrow frequency distribution) Both white light, lasers used in microscopy techniques Polarization of Light Plane where electric field vector lies, E=Eºcos(ωt) Perpendicular to direction of propagation Vertical s= horizontal p= vertical for propagation Parallel to floor horizontal This nature used extensively In microscopy: pol microscopy, DIC, SHG Circular polarization: H,V (s,p) 90 degrees out of phase elliptical polarization: less than 90 out of phase Particle (Quantized) Behavior Light interacting with matter: absorption, reflection photon smallest unit- energy corresponds to frequency () E hv c Eh h=6x10-34 J*s Planks constant ~10-19 J for visible light (=600 nm) •best for describing absorption, emission of light •Best for describing how detectors work (photomultipliers, Diodes) Wave Behavior Constructive, destructive interference 0, 180 degrees Limiting cases for complete constructive, Destructive interference, respectively Underlies image formation in almost all forms of microscopy: phase, DIC, polarization, Some advanced forms of confocal Representations of Light Absorption, lasers Interference, Image formation Good for modeling Light propagation: Ray Tracing Not real form Wave, particle duality physically important Some phenomenon described by both Hooke made the first optical microscope Robert Hooke The first image of Hooke and the birth of the term “Cell” Converging (focusing) Lens •The parallel rays converge at the second focal point F‘. •The first focal point is at the front. All rays originated at This point become parallel to the axis after the lens. Diverging (defocusing) Lens Focal length is negative To an eye on the right-hand side, these diverging rays will Appear to be coming from the point F’: the second focal point. Snell’s Law where q1 is the angle of incidence, q2 is the angle of refraction medium index air (STP) 1.00029 water (20° C) 1.33 crown glass flint glass 1.52 1.65 Ray Tracing Rules for locating image Only need 2 rays Single-lens Imaging system Real image: if rays intersect and unite in image plane and can be projected onto some surface in image plane Two-lens Imaging system Virtual Image: if rays diverge, but backwards extensions converge and intersect behind specimen A slightly more complicated imaging system aka old microscope Eye is part of optical system of microscope Infinity Corrected Microscopes: last 15 Years Infinity optics allows insertion of Filters, analyzers without changing tube length, or final image Infinity=parallel Basic Formulae in air Object plane Lensmakers equation Thin lens formula Image plane 1 f (n 1) 1 1 1 '' f s s 1 R1 1 R2 s '' h '' m s h ( n 1) d nR1R2 Some Conventions • S is distance from the object; S’ is distance from the image • Sign conventions: m = positive for inverted image; negative for upright • Sign conventions: f = positive for converging lens; negative for diverging lens Keplerian Telescope Galilean telescope Upright Microscope Geometry Inverted Microscope Geometry Inverted vs Upright Geometries Upright: • Move stage for focusing (unless fixed stage) • Optical path is simpler • Easier for immersion (long working distance) Inverted: • Move objective for focusing • Better access for live cells in culture • Electrophysiology • Harder for oil, water immersion. Refractive Index Depends on the Wavelength This is called dispersion Dispersion of Air Dispersion of Glass How to Calculate? Sellmeier Equations All but quartz Quartz These values are tabulated (e.g. CVI Laser, Melles Griot) Chromatic Aberration in Photography Doublet Lens Corrects Aberration Crown Flint Spherical Aberration could also be caused by the use of the cover glass-slip. A correction collar might be found on the objective to set the thickness of the glass-slip. If no correction collar can be found, the objective is corrected for a 0.17 mm glass-slip. Astigmatism and coma are caused by imperfection in the lens manufacturing. Field Curvature Newer: CF lens – meaning Chromatic aberration Free. The Main Function of the Microscope is NOT to MAGNIFY What’s Important for a Microscope? 1. Contrast is necessary to detect detail from background light from an object must either be different in intensity or color (= wavelength) from the background light: Both used in light and fluorescence microscopy 2. Resolution fundamentally limited by diffraction diffraction occurs at the objective lens aperture Numerical Aperture (N.A.) q specimen Objective lens Image plane From diffraction theory Minimum spot d n sinq d min 1.22 2 NA N.A. = n sinq NA= radius/focal length Abbe` Limit ~250 nm in visible Resolution only determined by NA and wavelength Electromagnetic Spectrum Visible region used for Light microscopy small Part of EM spectrum Resolution limit : λ/2 ~200 nm: Visible good for Live specimens: Cells, organelles Ideal for micron sized structures EM, X-ray cannot do live imaging Consider microscope object as simple grating Spacing of Grating and Diffraction Pattern S=3 microns Inverse relationship (transform) of object spacing (or size) and diffraction pattern S=12 microns Double-slit Experiment Condition for Constructive interference: a sinθ = nλ n = 0, 1, 2, 3 … After focusing: d=fλ/a Multiple-slit is not Too Different Abbe’s Diffraction Pattern from White Light Tube Lens d1 Fringe spacing in the image: d2 = f’ λ / d1 = f’ λ a / f λ = M a Requires at least one of the first order diffraction spot in order to form the image. Diffracted Spots in back focal plane a) b) c) d) No specimen diffraction: no image Specimen diffraction: no collection, no image 0th and first order diffraction 0th and first and second order diffraction better resolution Abbe showed need for central and diffracted spot 2 D diffraction of periodic structures: on road to real object Visualizing objects below the diffraction limit 60 nm Subresolution beads Appear same size 800 nm Diffraction from self-luminous spot: delta function source Impossible to remove interference rings: Separated exactly by n Absence of light between Rings is due to destructive interference Light from each point of the object is spread out in the microscope because light diffracts at the edges of the lens Central spot is 0th order diffraction or Airy disk Contains 84% of power Aperture size, Interference, and Resolution Full aperture Interference in image plane Con inter at P’ Destr at P’’ P’-P’’ distance Smaller for full aperture Reduced aperture Maxima larger, max, min further apart: Covers more cone cells or camera pixels: less resolution Always fill Lens aperture For highest resolution RESOLUTION The resolution of a microscope is the shortest distance two points can be separated and still be observed as 2 points. Well resolved just resolved Not resolved MORE IMPORTANT THAN MAGNIFICATION !! High NA Low NA Limits on NA and Resolution? Air: NA= 0.95 for a =70 degrees Immersion increase n: NA= 1.4 a =67 degrees (oil) n~1.5 1.2 (water) n=1.33 Higher index materials for greater resolution? Some exist: methyl iodide, smelly, toxic Also need higher index coverslips, slides Useful Magnification Useful Magnification (total) = 500 to 1000 • NA (Objective) More mag does not help, and decreases image quality through artifacts, diffraction Limit comes from rod separation in the eye Depth of Field: Axial resolving power Defined only by NA2 Small Depth of Field at high NA Focusing critical at high NA Gromit captured at f/22 (left) and at f/4 (right). f = image distance / effective diameter of the lens