* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ABB The - Voltimum
Buck converter wikipedia , lookup
Stepper motor wikipedia , lookup
Control system wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Current source wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Portable appliance testing wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
Ground (electricity) wikipedia , lookup
Resilient control systems wikipedia , lookup
Surge protector wikipedia , lookup
Integrated circuit wikipedia , lookup
Automatic test equipment wikipedia , lookup
Rectiverter wikipedia , lookup
Protective relay wikipedia , lookup
Distributed control system wikipedia , lookup
Electrical substation wikipedia , lookup
Residual-current device wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Fault tolerance wikipedia , lookup
Protection - Overload What do we mean by a fault? Overload Operating condition in an electrically undamaged circuit which causes an current to flow in excess of the full load current Example: Starting condition during DOL start © Abb Control Ltd - 1 If this type of fault continues indefinitely because of an anomolous operating condition., damage begins to occur creating………. ABB Protection – Short Circuit What do we mean by a fault? Short Circuit © Abb Control Ltd - 2 Operating condition in an electrically damaged circuit where there is an accidental or intentional connection by a relatively low resistance between two points of a circuit which are normally at different voltages This type of fault can generate high current flows, arcing and fire if not cleared quickly ABB © ABB Control Ltd - 3 01-04-06 - An explanation of the terms BS EN 60947 standard for Industrial Switchgear & BS EN60898 for Domestic Circuit Breakera ABB © Abb Control Ltd - 4 The ‘British Standards’ BS EN 60947 (Industrial switchgear) BS EN 60898 (Domestic circuit breakers) ABB © Abb Control Ltd - 5 BS EN 60947 Which section ? EN 60947-2 for Circuit breakers EN 60947-3 for Switches EN 60947- 4-1 for Motor protection EN 60947-6-1 for Auto changeover ABB © Abb Control Ltd - 6 BS EN60947-2 Icu - Ultimate Short Circuit breaking capacity O - 3 min - CO ALL at full fault level Breaker must be intact and be able to pass insulation resistance test at the end of the test Breaker does not need to able to carry full rated current continuously without overheating after test Ics - Rated duty Short Circuit Breaking capacity Often expressed as a % of Icu O - 3 min - CO - 3min - CO The test may be at fault level lower than Icu value Breaker must be intact and be able to pass insulation resistance test at the end of the test Breaker MUST be able to carry full rated current continuously without overheating after test Note: ABB O test begins with breaker closed before current applied CO test requires breaker to close onto fault current BS EN60947-2 © Abb Control Ltd - 7 Icw - Rated Short-time Withstand current Preferred rating - 1 sec Limits are 12x In or 5kA whichever is greater for In <= 2500A 30kA for In > 2500A Utilisation Category A type - Instantanous type B type - Selective short circuit B type MUST have withstand (Icw)rating defined Icm Rated duty Short Circuit Making Capacity ABB © Abb Control Ltd - 8 BS EN60947-2 It is recommended that circuit breakers are examined for contact and arc chute damage after every fault clearance Icu/Ics values mean breakers can be put back into temporary service after fault clearance ABB © Abb Control Ltd - 9 Definitiions within BE EN 60947 In – Nominal current rating Iu – Rated uninterrupted current Ue – Operational Voltage ABB AC/DC Distribution Which mcb curve? © Abb Control Ltd - 10 BS EN 60898 B type General purpose lighting & power Magnetic setting 3 - 5x In BS EN 60898 C type Industrial application with high surges Magnetic setting 5 - 10x In Different devices for DC applications above 60V ABB