* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Per Phase Analysis
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stepper motor wikipedia , lookup
Electrical substation wikipedia , lookup
Current source wikipedia , lookup
Surge protector wikipedia , lookup
History of electric power transmission wikipedia , lookup
Earthing system wikipedia , lookup
Distribution management system wikipedia , lookup
Buck converter wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power electronics wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Alternating current wikipedia , lookup
Lesson 35 Per Phase Analysis Learning Objectives Derive the relationship between line to line voltages and line to neutral voltages in a balanced Y-Y three phase circuit. For a balanced Y-Y three phase circuit convert the line to line voltage phasor to the line to neutral voltage phasor and vice versa. Plot the phasors of line to line voltages and line to neutral voltages for a Y-Y three phase circuit. Derive the relationship between line current and phase load current in a balanced Y- Δ three phase circuit. For a balanced Y- Δ three phase circuit convert the line current phasor to phase load current phasor and vice versa. Plot the phasors of line current and phase load current in a balanced Y- Δ three phase circuit. Review Y-Y system Y Load Generator Lines PHASE/LINE VOLTAGES Line and phase voltages of the Y-connected three-phase generator. Determining a line voltage for a three-phase generator. Line/Phase Voltages for a Wye Circuit Using the following relationship Vab 3Van30 we can also convert back… Vab Van 330 E AN VAB 330 Therefore, given any voltage at a point in a balanced, 3-phase Y system, you can determine the remaining 5 voltages by inspection. Law of Sines The ratio of the length of a side to the sine of its corresponding opposite angle is constant a b c sin sin sin Applying the law of sines to the vector EAB: 120 180 120 30 2 E AN E AB sin 30 sin120 sin120 E AB E AN E AN 3 sin 30 EAN EBN Nominal voltages If phase voltage Van = 120 V then line voltages Vab = 208 V. This is referred to as 120/208-V system. Two other common nominal voltages are 220/380-V and 347/600-V. Currents for a Wye Circuit For Y loads, line current and phase current are the same. I a Van / Z an Line current Phase current Wye-Wye Single Phase Equivalent Original circuit Single-phase equivalent Example Problem 1 EAB = 2080 V . Find the phase voltages and line currents. load definitions Review Y-Y For loads, phase voltage and line voltage are the same thing. Line currents are the currents in the line conductors. Phase currents are the currents through phases . Line/Phase Currents for a Delta Circuit Ibc Line current Phase current Line/Phase Currents for a Delta Circuit Relationship between line and phase currents I ab Vab / Z ab I a I ab I ca I a 3I ab 30 For a balanced system, the magnitude of line current is 1.732 times the magnitude of the phase current and line current lags phase current by 30. Therefore, given any current at a point in a balanced, 3-phase system, you can determine the remaining 5 currents by inspection. Line/Phase Currents for a Delta Circuit Phasor diagram Equivalent Ckt to solve Wye-Delta Problem This is just an equivalent circuit of the load side! What is missing from the equivalent circuit? Ia , Eab , Ean You can only use the equivalent circuit to solve for load side voltages and currents: Vab, Iab Notice that this equivalent circuit uses LINE VOLTAGE #1 mistake with DELTA circuits is using the wrong kind of voltage! Example Problem 2 Ia = 41.66.9 A . Determine the phase currents in the load. Determine the supply line voltage EAB and the supply phase voltage EAN. Line Impedances in 3 Phase AC Impedances in transmission lines complicate three phase analysis Voltage drop in the transmission line must be accounted for: EAN will not be the same as Van VAa Wye-Wye Single Phase Equivalent Original circuit Single-phase equivalent •Notice that the neutral line impedance drop is ignored on the single phase equivalent. •No voltage drop occurs across this neutral line since in reality, no current flows through it. Wye-Wye Single Phase Equivalent Original circuit + VAa - Single-phase equivalent •Use KVL on the single phase equivalent to find unknowns: EAN –VAa –Van = 0 Example Problem 3 EAB = 2080 V. Determine: a. Line Currents b. Load phase voltages Delta To Wye (∆→Y) Conversion A Delta circuit with line impedances cannot be solved without first performing a ∆→Y conversion. The Delta load can be converted to an equivalent Wye load Z ZY 3 Equivalent Delta Ckt with LINE IMPEDANCES WYE to DELTA CONVERSION ZY Z 15 21 j 57 j 3 3 Example Problem 4 EAB = 2080 V. Determine: a. Find load phase voltage Vab b. Find the load phase current Iab .