* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download pickeringtest.com
Survey
Document related concepts
Stray voltage wikipedia , lookup
Electrical substation wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Voltage optimisation wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Alternating current wikipedia , lookup
Zobel network wikipedia , lookup
Mains electricity wikipedia , lookup
Buck converter wikipedia , lookup
Current source wikipedia , lookup
Power MOSFET wikipedia , lookup
Distribution management system wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Transcript
40-260 Precision Programmable Resistor Module O Precision Variable Resistance From 90to 8k O 3 Channels Per Module O Very High Accuracy and Stability O Controlled by Simple Resistor Value Calls O Fine Setting Resolution <10m O Short and Open Circuit Simulation O Low Thermo-Electric EMF O Simple Calibration With External DMM O VISA & Kernel Drivers Supplied for Windows XP/Vista/7/8 O Supported by PXI or LXI Chassis O 3 Year Warranty The 40-260 is the first in a new family of PXI based precision programmable resistor modules from Pickering Interfaces. This new generation of modules features high resistance setting resolution with excellent resistance stability and accuracy through the use of innovative switching networks and software correction techniques. Each module supports three identical resistor channels that can be set to a range of resistance values with a setting resolution of better than 10m, making the 40-260 ideal for simulating sensors that require fine adjustment of their resistance. Thanks to the use of innovative technology the 40-260 ensures all resistance values can be set – no missing values because of switch resistance or resistor tolerance. Additionally, each channel can be set as open or short circuit to simulate faults in cabling systems. Applications include strain gauge and temperature dependent resistor emulation. Each channel can operate with a differential input voltage range of greater than ±15V relative to a defined common mode voltage. The common mode voltage can be set to 0V, (input range of at least ±15V), +12V (input range of +27V to -3V), -12V (input range of -27V to +3V) or an external common mode source of up to ±50V. The 40-260 provides a convenient system to support calibration of the resistance for each channel using an external DMM connected to the Calibration port. The calibration system permits modules to be cascaded so just one DMM can support the calibration of multiple devices and resistor channels in-situ. Calibration can be performed while the UUT is connected to the resistor channel connector. Use of special switching techniques reduces measurement errors caused by thermo-electric EMFs to a minimum. The 40-260 offers a stability, accuracy and setting resolution unmatched by any other PXI resistor module, minimizing the need for customized resistor modules and user calibration in the test system. The 40-260 can be supported in an LXI Modular Switching Chassis such as the Pickering 60-100A, 60-102 or 60-103. RESISTOR CHANNEL CONNECTOR CHANNEL 2 CALIBRATION PORT CONNECTOR CHANNEL 3 COARSE ADJUST FINE ADJUST CALIBRATION MUX Functional Diagram for the 40-260 Precision Programmable Resistor Module pickeringtest.com ISSUE 3.0 MAY 2013 CHANNEL 1 0.10 Specification Resistor Channels 0.08 Configuration: 3 resistor channels per module. Resistance Range 40-260-001 0.06 Resistance resolution: <10m, continuous resolution, no missing settings. Accuracy: 0.1% (can be improved with calibration). Short Circuit Setting: <0.3initial Open Circuit Setting: >109 % ERROR 0.04 90 to 8kand open circuit or short circuit. 0.02 0 -0.02 -0.04 -0.06 -0.08 -0.10 Operating Voltage: 50 Common mode voltage Input voltage range 0V -15V to +15V +12V -3V to +27V -12V -27V to +3V External Exernal ±15V 250 450 650 RESISTANCE (OHMS) 850 1050 Typical accuracy of 40-260 over the entire resistance range measured at 21˚C Performance is measured in 10m increments by making a resistance call (in Ohms) to the module and then measuring the actual resistance with a DMM. Vertical axis shows the reading error as % of the requested value. Common mode voltage can be selected by software control. Default value is 0 Volts. Damage level is a differential voltage level of ±18V wrt common or the maximum power rating, whichever is lower. Other Resistor Modules Pickering Interfaces manufacture a range of variable resistor modules in the PXI format. If you have a requirement for a variable resistor module please contact your local sales office with the information below and we will advise you on the best solution for your application. Ext common mode voltage: ±50V Maximum power: 100mW Lowest Resistance † Thermo-electric emf: <2μV 90 to 260 <5μV60 to 8k Highest Resistance Resistance - power off: Open circuit Operating time: 3ms typical Resistance Resolution Overall Accuracy Maximum Power/Current Calibration Channel Number of Channels (variable resistors) Function: Supports 4 terminal measurements of all the channels in the module. Modules can be cascaded together to permit single DMM to support multiple modules with resistor channel connected to UUT. Software support: Supplied with software that accepts a resistance instruction. Power +3.3V +5V +12V -12V 0 0.2A 10mA 10mA Physical Parameters Physical characteristics: One slot, 3U PXI. Weight: 280g 3D models in a variety of popular file formats are available on request. PCI Interface: 33MHz, 32-bit address, 16 bit data. Connectors: 15-way male D-type for resistor channels. 9-way male D-type for calibration connection. † Resistance is as measured across the user connector terminals, minimum resistance must have a non-zero value. Product Order Codes 3 Channel Precision Resistor 90 to 8k 40-260-001 Accessories: Calibration port to DMM lead (shrouded 4mm bayonet plug) for single module (1x9way D-type) 40-975-009-SL1 for two modules (2x9way D-types) 40-975-009-SL2 for three modules (3x9way D-types) 40-975-009-SL3 (calibration leads capable of supporting a greater number of modules are available, please contact sales office) Mating Connectors & Cabling For connection accessories for the 40-260 please refer to the 90-010D 15-way D-type and 90-003D 9-way D-type Connector Accessories data sheets where a complete list and documentation can be found for accessories, or refer to the Connection Solutions catalog. The 40-260 uses innovative techniques which are the subject of protected Pickering Interfaces intellectual property rights. pickeringtest.com Soft Front Panel for the 40-260 Precision Resistor Module pickeringtest.com Programming Pickering provide kernel, IVI and VISA (NI and Agilent) drivers which are compatible with 32/64-bit versions of Windows including XP, Vista, 7 and 8 operating systems. The VISA driver is also compatible with Real-Time Operating Systems such as LabVIEW RT. For other RTOS support contact Pickering. These drivers may be used with a variety of programming environments and applications including: y National Instruments products (LabVIEW, LabWindows/ CVI, Switch Executive, MAX, TestStand, etc.) y Microsoft Visual Studio products (Visual Basic, Visual C+) y Agilent VEE y Mathworks Matlab y Geotest ATE Easy y MTQ Testsolutions Tecap Drivers for popular Linux distributions are available, other environments are also supported, please contact Pickering with specific enquiries. PXI & CompactPCI Compliance The module is compliant with the PXI Specification 2.2. Local Bus, Trigger Bus and Star Trigger are not implemented. Uses 33MHz 32-bit backplane interface. Safety & CE Compliance All modules are fully CE compliant and meet applicable EU directives: Low-voltage safety EN61010-1:2001, EMC Immunity EN61000-6-1:2001, Emissions EN55011:1998. PXI & LXI Chassis Compatibility Compatible with all chassis conforming to the 3U PXI and 3U cPCI specification. Compatible with Legacy and Hybrid peripheral slots in a 3U PXI Express chassis. Compatible with Pickering Interfaces LXI Modular Switching chassis. For information on driving your switching solution in an LXI environment refer to the LXI Product Guide. Operating/Storage Conditions Operating Conditions 0°C to +55°C Up to 90% non-condensing 5000m Storage and Transport Conditions Storage Temperature: -20°C to +75°C Humidity: Up to 90% non-condensing Altitude: 15000m Please refer f to t the th Pickering Pi k i Interfaces “Connection Solutions” catalog for the full list of connector/cabling options, including drawings, photos and specifications. This is available in either print or as a download. Alternatively our web site has dynamically linked connector/ cabling options, including pricing, for all Pickering PXI modules. Latest Details Please refer to our Web Site for Latest Product Details. www.pickeringtest.com “The Big PXI Catalog” gives full details of Pickering’s entire range of PXI switch modules, instrument modules and support products. At over 500 pages, the Big PXI Catalog is available on request or can be downloaded from the Pickering website. Ever wondered what PXI is all about? Pickering Interfaces’ “PXImate” explains the basics of PXI and provides useful data for engineers working on switch based test systems. The PXImate is available free on request from the Pickering website. The “PXI Module Map” - a simple foldout selection guide to all Pickering’s 600+ PXI Modules. pickeringtest.com © Copyright (2013) Pickering Interfaces. All Rights Reserved Pickering Interfaces maintains a commitment to continuous product development, consequently we reserve the right to vary from the description given in this data sheet. Operating Temperature: Humidity: Altitude: