* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download v Brochure Company Presentation ()
Pulse-width modulation wikipedia , lookup
Current source wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electrical ballast wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Ground (electricity) wikipedia , lookup
Power engineering wikipedia , lookup
Power MOSFET wikipedia , lookup
Earthing system wikipedia , lookup
Opto-isolator wikipedia , lookup
Distribution management system wikipedia , lookup
Light switch wikipedia , lookup
History of electric power transmission wikipedia , lookup
Surge protector wikipedia , lookup
Electrical substation wikipedia , lookup
Stray voltage wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
BROCHURE COMPANY PRESENTATION SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY OUR MISSION From the idea to its application. To like your job is the best way to do it very well. Following this concept we have always designed our products focusing our attention to their application, so that “from the idea to its application” is not only a slogan but it has always been our method of job shared by management and collaborators. The red line which has always linked together all the efforts of the company, is to turn ideas into products concentrating on their applications. We have developed this concept in order to build a corporate assets made of good clients and our own “Know How”. We have later increased the number and the “quality” of our clients and we have developed our products starting from the drawing. This has been our mission. We don’t think to have achieved it yet, because we must not ever regard ourselves as arrived to the top and we can always improve ,but we can strongly affirm that our company offers a range of interesting products, so that we have been able to enter in the global international market. Since 1994 when in Florence Electrical Fair we showed the circuit breaker MV unit with isolator below and breaker above, which has been lately adopted by all the players of the MV market; then the first SF6 three positions switch , the CB and the new Ring Main Unit, also available in the extendible version. At last the Internal Arc Proof Compact Station. Following our corporate policy we have created several products completely designed by us and realized under our direct control that starts from the components and arrives to the applications. Today we can say that SEL can cover every necessity of the secondary MV Distribution up to 40.5 kV with its products. As told before we haven’t reached the top yet and very soon will arrive other new products that will hopefully let us go on working and exporting our job Our mission is to take up the challenge of the global market using the high technological content of our job and products, in order to be leading players also in countries where it is not possible to compete on costs of production. It is still possible to take up the challenge of the global market thanks to the pleasure that we find in doing our job and to the cleverness of the people who work in this company. Good job for everybody. Management of SEL. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY PRESENTATION SEL is a continuously growing , dynamic Italian company that produces ( manufactures ) switchboards, MV and LV devices and transformation stations. Sel is specialized in designing its products ,including the components. It also can supply a complete offer to the market: components, boards and turnkey solutions. Some reasons of our growth are for sure the entrance in new markets by opening our branches and the increasing of investments in research and development of new products SEL S.p.A. - ITALY Marketing and sales Project planning and engineering Research and Development Production of MV LBS and Vacuum CB Assembly of MV switchboards Shipping Service and customer support SEL TECH – Branch in China Marketing and sales Assembly of MV switchboards only for China market Shipping Service and customer support in the Asian market SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY HISTORY Founders of SEL , Alessandro and Leonardo Leporatti, could take advantage from their experience in the family business that their father started at the beginning of the 60’s and where they realized big electrical plants of every kind. They started in a small workshop collocated in the countryside from the windows of that it was possible to admire the hills where the famous genius Leonardo da Vinci was born. SOME MILESTONES IN SEL’S HISTORY: 1988 Foundation of 1989-91 Specialization in the construction of MV and LV switchboards 1992 Doubling of production space 1993 Investments and staff increase 1994 SEL’s module with isolator below and SF6 circuit breaker above revolutionizes the market by providing two times more compact solution for medium voltage substations. 1996 SF6 isolated TPS “Three Position Switch”. TPS SF6 switch is a turning point for SEL meaning a new era of growth and success and starting business abroad. SEL concentrates its force on MV switchgear 2001 SEL moves to a more spacious factory. At the same time it enters into the Chinese market 2002 SEL opens a branch in Shanghai. 2003 Ring Main Unit TPR6. SEL recruits new experts in their fields and invests more in the research. 2004 Vacuum circuit-breaker TCB. Export increases 2005 New markets and distributors 2006 SEL becomes a private limited company and opens a new branch in Bulgaria 2007 SEL introduces its Vacuum Circuit Breaker up to 1250A 24 KV 2007 SEL introduces the New TPR6 24 KV - G. I. S. 2008 SEL presents its fully tested Compact Station according to IEC 62271-202 2008 SEL improves its production capacity with its new robotic production line 2009 SEL introduce its TPR6 36 KV. - G. I. S. 2009 SEL introduce its PLS 24 and 36 kv (Pole mounting switch disconnector) SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY HOW TO REACH US BY PLANE Closest airports SEL is situated in the hearth of Tuscany between the airports of Florence and Pisa BY CAR On the motorway A11, exit at signpost for Montecatini Terme Follow the signposts for Fucecchio, Empoli. Drive along SS436 and drive via the centres of Monsummano Terme, Cintolese and Castelmartini. After you have passed the centre of Castelmartini turn left onto the road called Via di Cerbaia. After 1600 meters turn left onto the road called Via Amendola. On the motorway A11, exit at signpost for San Miniato Follow the signposts for Fucecchio, Montecatini Terme. Drive along SS436 road “Via Francesca” and pass through the centres of Fucecchio and Stabbia. After you have passed Stabbia turn right onto the road called Via Cerbaia. Drive along for 1600 meters and turn left onto the road called Via Amendola. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY QUALITY SEL uses ISO 9001-2000- based quality control system in planning and production. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY CERTIFICATES & APPROVALS SEL products have been approved by Electric Distribution Companies and by Power Research & Testing Companies in many countries. (For information: [email protected]) CERTIFICATES All our production is under technical control and accident prevention and it respects the main international and national standards. Our company possess official certificates which are obtained carrying out tests on prototypes in our test rooms. These certificates accepted by the following authorized bureaus: CESI: Italian Experimental Electro Technical Centre in Milan. National Electro Technical Institute “Galileo Ferraris” in Turin. TUV Laboratories SINAL. ABS KEMA LLOYD’S BUREAU VERITAS ICMET XIAN Laboratory of China. RINA SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SOFTWARE SEL is able to provide its users such as design engineers, installers and wholesalers with all the necessary software needed. The software that SEL offers for its users is divided into: ELEMENTARY Microsoft Excel based software for the quotation of TPS MV switchgear in Windows environment SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY TPS-CAD Software for designing the TPS medium voltage switchboards in the AutoCad environment SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY REFERENZE AIRPORT & SEAPORT Pisa airport, Italy Brescia airport, Italy Marseille airport, France CaiLan Sea port, Vietnam Puerto Guayacán, mining sea port, Chile OS Romairport Bucharest, Romania Port of Livorno, Italy Constanta sea port, Romania Freight village Americo Vespucci, Livorno, Italy Port Construction Command, Xian, China SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY UTILITY EDF, France Fortum Power and Heat, Finland LYDEC, Marocco Elettrica, Romania Radeema, Marocco Hanoi Power Company, Vietnam CEZ, Bulgaria Amendis, Marocco KESH, Albanian Power Corporation Radeef, Marocco ENEL, Italy CHILECTRA, Cile Energopomiar, Poland Bejing Power Supply, China Gost, Russian Evn, Macedonia SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY HOSPITAL Clinique St. Etienne, France US-hospital, Landstuhl, Germany Hospital Spallanzani, Rome, Italy Hospital, Usez, France Hospital, Warsaw, Poland Clinica 1 Mai, Bucarest, Romania Hospital, Pori, Finland Hospital Bouqueval, France SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY POWER PLANTS Nuclear Power Plant, Flaminville, France Hydroelectric power plant, Lecco, Italy Power Plant Łagisza, Poland Hydroelectric power plant, Arezzo, Italy Hydroelectric Power Plant, Jalasjoki, Finland Phong Phu Power Plant, Vietnam Hydroelectric Power Plant, Kokaliane, Bulgaria Hydroelectric Power Plant, Myczkowce, Poland Hydroelectric Power Plant, Katunzi, Bulgaria SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY INDUSTRY Renault, France LG Electronics e LG Innotek, Poland Coca Cola, Greece Nestlé, Turin, Italy Hoa Phu Industrial Park, Vietnam Pirelli tyres, Milan, Italy Ferrari, Maranello, Italy Saint Gobain, Mexico Namtrieu shipping factory, Vietnam Cement industry, Casablanca, Marocco Phosphate mine, Youssoufia & Ben Guerir divisions, Marocco Song Hau Steel Mill, Vietnam Rolls Royce KME Italy, Lucca, Italy Danube-Pak, Kherson, Ukraine Nuovo Pignone, Firenze, Italy SKF Stab. Massa, Italy EATON Services Ltd., Lucca, Italy Europa Metalli SpA. Lucca, Italy Termomeccanica, La Spezia, Italy SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY TRANSPORT & RAILWAYS High speed train link, Rome, Italy VR Track Ltd. Kemijarvi, Finland Haiphong bridge company, Vietnam New Nanjing bridge, China Aria, logistics, Poland Florence S.M.N central raiway station, Italy Rome Ring Road, Italy Hangzhou Bay Bridge, China WIND POWER & SOLAR ENERGY Varna Wind Power Generator, Bulgaria Samos Island wind park, Greece Kavarna wind farm, Bulgaria Sardinia Island, Alta Nurra Wind Farm, Italy Vestas wind turbine, Sicily Island, Italy “Erga and Enel Green Power Troyan energy, wind power generator, Bulgaria Sunelectrics, Bari, Italy Yambol wind power generator, Bulgaria Produzione Fotovoltaiche, Viterbo, Italy La Fabbrica del Sole, Arezzo, Italy Alerion Energie Rinnovabili, Brindisi, Italy SunElectrics S.r.l. - Impianto DIVELLA, Agrinova 1, Binardo, Mascava - Puglia,Italy SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY INDUSTRY Carrefour shopping center, France Casino Calama, Santiago, Chile Prisma shopping center, Finland, Rauma, Raahe, Kuopio Ferio Shopping Mall, Poland Mall Plaza Sur San Bernardo, Santiago, Chile Leclerc shopping center, France Lakai Mart, Ho Chi Minh City, Vietnam Leroy Merlin Mall, Poland Shopping center Casino, France Volga shopping mall, Voronezh, Russia Walter Mobel, Poznan Poland Dealu Bradului shopping center, Bucharest, Romania Makro Mall, Poland Sivas Shopping Mall, Krasnodar, Russia Leclerc shopping cemter, Slupsk, Poland Shopping mall, Artemovsk, Ukraine Hyundai showroom, Sofia, Bulgaria International exhibition center, Kiev, Ukraine SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SPORT CENTER Athens Olympic stadium, Greece Olympic village, Greece Taihu International Golf Club, China Borovets ski resort, Bulgaria Aerial tramway and ski lifts, Abetone ski resort, Italy Bansko ski resort, Bulgaria OFFICE BUILDING Passat, Poland IP Networks Ltd., Finland Saigon Pearl Building, Ho Chi Minh City, Vietnam Pearl Plaza, Wujiang, China Le Thanh Ton building, Ho Chi Minh City, Vietnam NgheAn Bank, Vietnam Corriere della Sera Newspaper, Bologna, Italy UNIVERSITY Lille university, France ASE university, Bucharest, Romania Lyon university, France Genoa university, Italy Florence university, Italy Technical High School de Troyes, France SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY OTHERS Telecom Italia - Italian Telecomunication Company Fincantieri S.p.A., Venezia Bacino galleggiante 40000T, La Spezia S.Giorgio del Porto S.p.A. (per M/N Enrico Costa), Genova SAIPEM (Posatubi "Castoro VIII"), Genova M/N RO-RO Tirrenia, La Spezia Terme Montecatini, Pistoia ENEL si - Cabina di trasformazione PALAZZO VECCHIO - FIRENZE Arsenale MARINA MILITARE, La Spezia Ferragamo S.p.A., Firenze Centro Nazionale delle Ricerche, Firenze SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY PRODUCT MEDIUM VOLTAGE > LB-TPS > SF6 GAS INSULATED LOAD BREAK SWITCH LB-TPS is a three position rotary switch (earth connection-open-closed) enclosed in an epoxy resin envelope. The envelope is filled with SF6 gas at a pressure of 0.4 bar. LB-TPS is available in both load break switch and isolator versions depending on the type of operating mechanism used. The equipment is sealed for life. The main characteristics of TPS LB are reduced dimensions and resin envelope made of one single piece. It is maintenance free due to a sealed envelope which is segregated from the external ambient. SOME TECHNICAL ADVANTAGES OF TPS LB ARE THE FOLLOWING: It is equipped with a movable mimic by showing immediate position of the switch Through a frontal window it is possible to check visually the position of switch contacts. It is provided with a pressure relief valve on its back side in case of internal fault. With the help of this structure in the event of overpressure the gas will go out from the opposite part where the operator is situated. All the above mentioned things together with excellent electrical and mechanical characteristics guarantee maximum safety, reliability and duration of the product.. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY TECHICAL DATA The following values are correct in an ambient temperature between -5º and 40°C and in the installations at the altitudes lower than 1000m. (For different values, please consult SEL). RATED VOLTAGE PHASE-PHASE TEST VOLTAGE FOR 1 MIN. AT 50HZ AND 7.2 kV 12 kV 17.5 kV 24 kV 20 kV 42 kV 38 kV 50 kV 23 kV 48 kV 45 kV 60 kV 60 kV 95 kV 95 kV 125 kV 70 kV 110 kV 110 kV 145 kV PHASE EARTH BETWEEN OPEN CONTACTS INSULATION LEVEL PHASE-PHASE AND PHASE EARTH IMPULSE TEST VOLTAGE BETWEEN OPEN CONTACTS 400 A RATED CURRENT MAKING CAPACITY (X SHORT- TIME IN 1 SEC.) WITHSTAND CONFORMITY WITH DEGREE PROTECTION 630 A 630 A 62.5 kV 50 kA 25 kA 20 kA* INTERNATIONAL IEC 60265-1 EXTERNAL IP30 ACCREDITED LABORATORYS INAL ACCREDITED LABORATORYS INAL CERTIFICATIONS CHINA NATIONAL ACCREDITATION OF LABORATORIES THIS VALUES ARE THE MAXIMUM APPROVED. * On request duration of short circuit up to 4 sec. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MEDIUM VOLTAGE > TCB > VACUUM CIRCUIT BREAKER UP TO 24KV 630A It is a known fact that the vacuum circuit breaker has become the dominant technology in the main world market and its diffusion is increasing in an outstanding way. Today it is possible to get very efficient vacuum circuit-breakers with electrical duration which is longer than mechanical duration, with total respect of environment (SF6 circuit breakers contribute to greenhouse effect and they need maintenance and a particular treatment at the end of their life cycle); but in particular, vacuum circuit -breakers offer the best performances thanks to the reduction of arc energy, very quick opening, insulation restoring after overvoltage impulse and reduction of mechanical energy needed for operating mechanism. It is a known fact that the vacuum circuit breaker has become the dominant technology in the main world market and its diffusion is increasing in an outstanding way. Today it is possible to get very efficient vacuum circuit-breakers with electrical duration which is longer than mechanical duration, with total respect of environment (SF6 circuit breakers contribute to greenhouse effect and they need maintenance and a particular treatment at the end of their life cycle); but in particular, vacuum circuit -breakers offer the best performances thanks to the reduction of arc energy, very quick opening, insulation restoring after overvoltage impulse and reduction of mechanical energy needed for operating mechanism. CONSTRUCTION CHARACTERISTICS The vacuum medium voltage circuit breakers for indoor installation TCB series are “sealed for life” pressure systems (IEC 62271-100 and CEI 71-1 Standards, EN 62271-100) and they are constructed using the separate pole technique. Each pole has a vacuum interrupter inside it which, thanks to a special production process, is incorporated in the resin. This construction technique ensures protection of the vacuum interrupter against impact, dust andcondensation phenomena and guarantees the lightning impulse withstand also on the external surface of the vacuum interrupter. The transmission is obtained by a mechanical central bar which allows to transform the circuit breaker in different executions very easily. ADVANTAGES - Long Mechanical life Reduced Maintenance Respect of Ambient: No Greenhouse or Toxic Gases are emitted during Operation Elevated Accumulated Amp Performances Short Arcing Time damages less contacts Short Opening Time Quick Recovery of Insulating capacity in case of Overvoltage SERIES The circuit-breakers are available in three versions: - TCB: standard for metal enclosed MV modules ICBV or ILCBV - TCB/LD: on truck version with right lateral operating mechanism. There are two version of this, 12kV and 24kV. - TCB/LS: on truck version with left lateral operating mechanism. There are two version of this, 12kV and 24kV. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY TECHICAL DATA The following values are correct in an ambient temperature between -5º and 40°C and in the installations at the altitudes lower than 1000m. (For different values, please consult SEL). RATED VOLTAGE Ur 12 kV 24 kV IMPULSE Up 75 kV 125 kV Ud 28 kV 50 kV WITHSTAND VOLTAGE DIELECTRIC WITHSTAND VOLTAGE TO EARTH AND BETWEEN PHASES (50HZ 1MIN.) RATED FREQUENCY fr 50 Hz RATED CURRENT Ir 630 A ** Isc 16 - 20 kA Ip 40 - 50 kA Ik 16 - 20kA Tk 3 sec. RATED BREAKING MAKING CAPACITY CAPACITY SHORT-TIME WITHSTAND CURRENT SHORT-CIRCUIT TIME SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MEDIUM VOLTAGE > PLS > Pole Mounted switch Disconnector PLS is an outdoor SF6 insulated pole mounted switch disconnector up to 40.5 kV. The stainless steel tank is particularly suitable for providing protection against the extremes of heat, snow, corrosion, moisture, salt and other critical environmental conditions. PLS switch disconnector can be remote controlled or operated manually with two different operating mechanisms. The first one is a transmitted operating mechanism which can be operated directly from the ground with the help of small ladders. The second one is a switch disconnector which can be operated from the ground by means of insulated hook stick. Two or three position Two or three way SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MAIN ELECTRICAL CHARACTERISTICS kV ALTITUDE IEC 62271-1 AMBIENT AIR TEMPERATURE RELATIVE HUMIDITY IEC 62271-1 7,2 12 12* 17,5 24 40,5* (3) m <1000 °C -25 ÷55 % 36 (2) 95 INSULATION RATED VOLTAGE kV 7,2 12 12 17,5 24 36 40,5 RATED VOLTAGE kV 7,2 12 12 17,5 24 36 40,5 LIGHTNING IMPULSE WITHSTAND VOLTAGE BETWEEN PHASES AND TOWARDS THE GROUND kV 60 75 95 95 125 170 185 LIGHTNING IMPULSE WITHSTAND VOLTAGE ACROSS THE ISOLATING DISTANCE kV 70 85 110 110 145 195 210 kV 20 28 42 38 50 70 95 kV 23 32 48 45 60 80 110 POWER FREQUENCY WITHSTAND VOLTAGE BETWEEN THE PHASES POWER FREQUENCY WITHSTAND VOLTAGE ACROSS THE ISOLATING DISTANCE RATED FREQUENCY Hz RATED CURRENT A RATED SHORT TIME WITHSTAND RATED PEAK WITHSTAND CURRENT RATED DURATION IP (MAKING ON FRONT FACE DEGREE OF PROTECTION ON ELECTRICAL ELECTRICAL ELECTRICAL MAINLY CLOSE NO OPERATION OPERATION MV CIRCUITS LINE IEC 60265-1 EARTHING OPERATION SWITCH EARTHING ACTIVE LOAD BREAKING CURRENT LOOP BREAKING CURRENT CHARGING BREAKING CURRENT FAULT BREAKING CURRENT SWITCH DISCONNECTOR SWITCH IEC 60265-1 IEC 60265-1 DISCONNECTOR IEC 60265-1 3 3X 67 making capacity 5 / Class E2 A 630 A 630 A 16 DISCONNECTOR IEC 60265-1 A 32 SWITCH DISCONNECTOR IEC 60265-1 A 32 A 57 DISCONNECTOR IEC 60265-1 OPTIONAL 5.000 operation / class M2 MECHANICAL ELECTRICAL 2,5 x Ik 3(1) SWITCH SWITCH 12.5-16-20 1.000 operations / Class M1 IEC 60271-102 DISCONNECTOR 16-20-21 100 breaks at In p.f.=0,7 / Class E3 IEC 60271-102 SWITCH SWITCH 16-20-25 (2) 1.000 operations / Class M1 SWITCH DISCONNECTOR IEC 60265-1 CHARGING BREAKING CURRENT EARTH IP DISCONNECTOR 630 - 1250 kA IP LOAD TRANSFORMER BREAKING CURRENT CABLE ) s SWITCH OPERATION MECHANICAL CAPACITY OF SHORT CIRCUIT TK DEGREE OF PROTECTION MECHANICAL kA CURRENT 50-60 OPERATION 400 breaks at In p.f. = 0.7 OPERATION (1) For Ik25 kA Maximum short circuit duration time 1s (2) Rated current is referred to 40°C ambient temperature. For different values contact SEL (3) For different values contact SEL * For Asian market SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MEDIUM VOLTAGE > TPS> Metal enclosed switchboards up to 24 kV 630A TPS MV switchboards are constructed of standardized modules in metal sheets. These modules contain SF6 insulated devices for switching and earthing. The main advantages of TPS switches are reduced installation and maintenance time and small dimensions. All this is obtained by ensuring CONSTRUCTION CHARACTERISTICS The switchboard is made of a metal structure composed of galvanized steel sheets that are assembled using rivets and bolts. This structure is built to withstand the electrodynamic stresses during the operation. A three position earthing switch is fixed to this structure. An envelope made of epoxy resin makes the isolation possible between the structure and live parts. An operating mechanism, a movable mimic and a voltage indicator are positioned in the front of the panel. The position of the switch is given by the movable mimic whereas the voltage signalling lamp indicates the voltages. It is possible to inspect the inside of the switch through an inspection window positioned above the operating mechanism. In the front of the panel there is a door giving access to different compartments, e.g. cables, fuses and measurement. When the door is closed it is possible to see inside the switch through the inspection window. If the module is equipped with a low voltage auxiliary compartment it is situated in its upper part. Safety characteristics The personnel safety is obtained by mechanical interlocks which guarantee correct operations of the device. In this way involuntary mistakes which could be dangerous for the operator can be prevented. Metal screens prevent access to electrical parts during maintenance operations. It is possible to block the switch in three positions with key locks. Series TPS is available in the following two series: Standard series: The series guarantees the internal arc proof on the frontal side up to 12.5kA for 1 sec. Internal arc proof series: The series guarantees the internal arc proof on the four sides up to 16 kA for 1 s SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY TECHICAL DATA The following values are correct in an ambient temperature between -5º and 40°C and in the installations at the altitudes lower than 1000m. (For different values, please consult SEL) RATED VOLTAGE PHASE-PHASE TEST VOLTAGE FOR 1 MIN AT 50HZ AND PHASE EARTH BETWEEN OPEN CONTACTS 7.2 kV 12 kV 17.5 kV 24 kV 20 kV 28 kV 38 kV 50 kV 23 kV 32 kV 45 kV 60 kV 60 kV 75 kV 95 kV 125 kV 70 kV 85 kV 110 kV 145 kV INSULATION LEVEL PHASE-PHASE AND PHASE EARTH TENSIONE DI PROVA A IMPULSE TEST VOLTAGE BETWEEN OPEN CONTACTS RATED CURRENT 630 A BREAKING CAPACITY (X 1 25 kA 20 kA 12.5 kA x 1 sec. 20 kA x 1 sec. (4 sec. On request) SHORT- TIME WITHSTAND 1: ICB, ICBR, 2ICB= 3 SEC. ON REQUEST 16 kA x 1 sec. (4 sec. On request) 12,5 kA x 1 sec. (4 sec. On request) TRANSFER CURRENT FOR STRIKER IN- FS TERVENTION MECHANICAL DURATION ELECTRICAL 1800 A SM, BSM, FS, SMM, SMS, FIM 1400 A 2000 (CEI 17.1) ICB, ICBR, ICBV, ILCBV, 2ICB 10000 (CEI 17.1) 100 (CEI 17.1) DURATION ITALIAN CEI 17 - 6 IN CONFORMITY WITH INTERNATIONAL DEGREE OF PROTECTION IEC 298 IP30 IP20 INTERNO / INTERNAL ACCREDITED LABORATORYS INAL CERTIFICATIONS ACCREDITED LABORATORYS INAL THE STRUCTURE STRUCTURE IS MADE OF GALVANIZED STEEL SHEETS AND IT IS TREATED WITH AN EPOXY POWDER PAINTING IN THE OVEN. THESE THESE POSSIBLE VALUES ARE THE MAXIMUM APPROVED. SEE MODULE TAGS DATA FOR NOMINAL VALUES. COLOUR RAL 7030 VALUES ARE THE MAXIMUM APPROVED. SEE MODULE TAGS DATA FOR NOMINAL VALUES. CHANGES IN STANDARDS OR MATERIALS CAN INFLUENCE ON ELECTRICAL CHARACTERISTICS AND OVERALL DIMENSIONS SHOWN IN THIS DOCUMENT. FOR THIS REASON THEY MAY BE CONSIDERED FINAL ONLY AFTER CONFIRMATION BY SEL. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MEDIUM VOLTAGE > TPR6> Switchboards for Ring Main Unit up to 7,2 Kv - TPR6 is an SF6 insulated ring main unit for the secondary distribution network. TPR6 uses the latest developments in switchgear technology by providing an extremely compact medium voltage switchgear solution. It can be supplied in a number of different configurations suitable for most switching applications in 7,2 up to 40,5 kV distribution networks. TPR6 is available in a standard configuration or a modular version making further extension possible. All this is obtained by ensuring maximum personnel safety. CONSTRUCTION CHARACTERISTICS TPR6 is a completely “sealed for life” system with a stainless steel tank containing all live parts and switching devices. A hermetically sealed steel tank from the outside environment ensures a high level of reliability as well as personal safety. The structure can withstand the electrodynamics stresses during the operation. The operating mechanism, movable mimic and voltage signaling lamps are positioned in the front panel. Switches are operated by means of spring-operated mechanisms. Movable mimic gives the position of the switch whereas the voltage signaling lamp indicates the voltages. Fuses and cable compartment are easily accessible through the front door which is interlocked with the earth switch. Should the low voltage auxiliary compartment be present, it is situated above the ring main unit. SAFETY CHARACTERISTICS The personnel safety is obtained by using mechanical interlocks. These mechanical locks operate as follows: When the switch disconnector is closed the earth switch can not be closed simultaneously and the access to MV cables (T, C and F modules) is prevented. When the earth switch is closed there is a free access to MV cables (T, C and F modules) but it is impossible to close the switch. When the access door to MV cables and fuses is open it is impossible to close the switch (T, C and F modules). Metal screens prevent access to electrical parts during maintenance operations. It is possible to block the switch in three positions with key locks. INTERNAL ARC WITHSTAND The robust design of the metal enclosure prevents deformations and ensures protection against fault. TPR6 is designed to withstand an internal arc caused by a rated short-circuit current for 1 second preventing any danger to the operator. A safety valve against accidental overpressure caused by an internal arc is located at the bottom of the metal enclosure. The gas is released to the bottom of the TPR6 without any danger to the operator. TPR6 has been type tested and it meets all the criteria of IAC class A FL, as defined by IEC 62271-200 standard, annex A. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY MODULE EXTENSIBILITY TPR6 switchboards are easily extensible on-site, without requiring the handling of gas or any special work. One or several modules may be simply added to the existing switchboard by using special connectors. MAIN ELECTRICAL CHARACTERISTICS MECHANICAL AND ELECTRICAL CHERACTERISTICS U.M. KV ALTITUDE IEC 62271-1 7.2 12 12* 17.5 24 36 40.5* m <1000 (1) °C -25 ÷ 55 (1) RELATIVE HUMIDITY % 95 INSULATION RATED VOLTAGE KV 7.2 12 12 17.5 24 36 40.5* RATED VOLTAGE KV 7.2 12 12 17.5 24 36 40.5* KV 60 75 95 95 125 170 185 KV 70 85 110 110 145 195 210 KV 20 28 42 38 50 70 95 KV 23 32 48 45 60 80 110 AMBIENT AIR TEMPERATURE IEC 62271-1 LIGHTNING IMPULSE WITHSTAND VOLTAGE BETWEEN PHASES AND TOWARDS THE GROUND LIGHTNING IMPULSE WITHSTAND VOLTAGE ACROSS THE ISOLATING DISTANCE POWER FREQUENCY WITHSTAND VOLTAGE BETWEEN THE PHASES POWER FREQUENCY WITHSTAND VOLTAGE ACROSS THE ISOLATING DISTANCE RATED FREQUENCY Hz 50-60 RATED CURRENT A 630-1250(2) RATED SHORT TIME WITHSTAND CURRENT (L - U1 MODULE) IK (5) kA 16-20-25 16-20-21 12.5-16-20 RATED SHORT TIME WITHSTAND CURRENT (F MODULE) IK (5) kA 16-20-25 16-20-21 12.5-16-20 RATED SHORT TIME WITHSTAND CURRENT (C - T - U2 MODULE) IK (5) kA 16-20-25 16-20-21 12.5-16-20 RATED PEAK WITHSTAND CURRENT IP (MAKING CAPACITY ) kA 2.5x lk RATED DURATION OF SHORT CIRCUIT TK s DEGREE OF PROTECTION ON FRONT FACE IP 3X DEGREE OF PROTECTION ON ELECTRICAL MV CIRCUITS IP 67 3(1) 3 (1) For other solution please contact SEL (*) For asian market SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY FUNCTIONS Connection and power supply on a open or closed ring network Power supply and protection of transformers with circuit breaker or combined fuse- switches up to 200A Power supply and protection of lines by a 630A circuit breaker Busbar coupling MV metering Earth switch for cable connection The letter under each figure identifies the function of the module. Each function can be supplied with options +; I or X on the left, right or on both sides. (*) All the modules supplied with option “I” on the left, right or on both sides will be equipped with 350mm wide metal enclosure which has the same height and depth than the module. See examples 6,7,8,and 9. All the singular modules and standard configurations can be extended or they can have an outgoing cable or connection to measuring module on the left, on the right or on both sides. For the code composition, choose the function or the configuration and the symbols +; I or X if needed. The configuration with “0” symbols means non extensible TPR6. For example the code of LLFF with the right extension is LLFF+. If LLFF has the right outgoing cable and the left extension the code is +LLFFI SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SUBSTATION MV/LV > CAB> MV/LV PREFABRICATED SUBSTATION SEL supplies complete prefabricated MV/LV substations made in concrete. The most important advantages of our products are: Maximum safety and reliability Reduced costs Quick realization and putting into service Personalized and flexible design Substations can be monoblock or panel type and this way they can meet all the requirements of a versatile plant. STANDARDS The substations are in compliance with IEC 62271-202 QUALITY SYSTEM Our production is made in accordance with quality control system EN ISO 9001:2000 certificated by TUV. TEST Walk-in e NO Walk-in type C.S. passed all tests according with IEC 62271-202 WALKIN NO WALKIN SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SPECIAL APPLICATIONS > MT > MV AUTOMATIC CHANGE OVER DEVICE MV swichboard with Automatic Change Over device composed by TPS Load-Breaker Switch equipped with motor drive LT operative mechanism. SAFETY CHARACTERISTICS The personnel safety is obtained by mechanical interlocks which guarantee correct operations of the device. In this way involuntary mistakes which could be dangerous for the operator can be prevented. Metal screens prevent access to electrical parts during maintenance operations. It is possible to block the switch in three positions with key locks. SERIES TPS is available in the following two series: Standard series: The series guarantees the internal arc proof on the frontal side up to 12.5kA for 0.7 sec. Internal arc proof series: The series guarantees the internal arc proof on the four sides up to 16 kA for 1 s. Main electrical characteristics See the TPS catalogs. SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY INTEGRATED DATA ACQUISITION > MONITOR 2003 > MANAGEMENT AND AUTOMATION SYSTEM MANAGEMENT AND AUTOMATION SYSTEM INTEGRATED DATA ACQUISITION, MONITORING AND CONTROL SYSTEM Monitor 2003 is an integrated data acquisition and control system. It is used in plant and substation monitoring and in industrial equipment control. Its easy construction technique and flexibility allows to use it in all the situations where it is necessary to acquire data from different machines and instruments. The system is composed of one or more GPCs “General Purpose Controllers” which are connected by the means of standard RS485, making reference to a personal computer for data acquisition and process. The GPCs allow to interface to the measuring instruments, existing PLCs or PLCs dedicated to real time alarm management, energy meters and gas meters. By the means of local network, standard telephones or mobile phones it is possible to connect to remote sites and control them in a centralized way. The core of the system is Monitor 2003 software. In PC application it is connected to GPC network by the means of RS485, by constantly comunicating with data collection terminals, monitoring the conditions and acquiring data. By the means of graphical data it is possible to control and illustrate the values. Real-time visual section is divided in two typologies;text data collection and graphic data collection. The report section configurable by the user allows to visualize the maximum, minimum and medium values. Alarm system completes the switchboard allowing to send special messages by mobile phone to a selected contact list. The flexibility of GPC configuration allows the modification of inputs. By the means of configuration it is possible to program 4 outputs of each GPC and connect it to the alarm functions centrally. MINIMUM CHARACTERISTICS OF PC Processor PIII 1000 Windows 2000 Pro 128 MB RAM 1 R S232 for GSM 1 R S232/R S485 for GPC Free space 100 MB on hard disc for data and programs Color printer or laser printer (optional local or network) Monitor 15” 800x600 SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY HEAD OFFICE SEL S.p.A. Via Amendola 51035 LAMPORECCHIO (PT) ITALY Tel. +39-0573-80051 Fax. +39-0573-803110 e-mail: [email protected] OUR BRANCHES IN THE WORLD BULGARIAN MARKET ASIAN & CHINESE MARKETS SEL BULGARIA S.r.l. SEL-TECH ELECTRIC (SHANGHAI) Co. Ltd. Sofia 1000, bul. Vasil Levski 112, et. 2, ap.10 BULGARIA Tel. +35 - 928432540 e-mail: [email protected] 3rd Floor, Bldg no.13, No.14, Sublane No. 172, Lane No. 1340 Jinshajiang Rd, Putuodistrict, Shanghai - China 200333 Tel. +86(0)21-52804397, 52804698 Fax +86 (0)21-52804698 (e-mail): [email protected] SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY SEL S.p.A. Via Amendola 51035 LAMPORECCHIO (PT) ITALY Tel. +39-0573-80051 Fax. +39-0573-803110 Web site : http://www.sel-electric.com e-mail: [email protected] SEL S.P.A. VIA AMENDOLA - 51035 LAMPORECCHIO (PISTOIA) - ITALY