Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Power over Ethernet wikipedia , lookup
Alternating current wikipedia , lookup
Buck converter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical substation wikipedia , lookup
Ground (electricity) wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Surge protector wikipedia , lookup
Mains electricity wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Installation instructions BAline MIO 3RPF Keep for future use! Valid from 01 December 2015 General information Fig. 1 Safety instructions WWARNIN The electrical installation must be performed by a certified electrician in accordance with the electrical installation regulations published by the Association of German Electrical Engineers (VDE 0100) or the standards and regulations of the country in which the device is being installed. The electrician must observe the installation instructions included with the electrical devices. BAline MIO 3RPF The BAline product line is a system consisting of individual modules for room and building automation (such as sun shading systems, lighting, windows, HVAC, etc.). Each basic module (e.g. BAline LONMCM) for bus coupling can be connected to up to 8 IO modules. The basic module can be combined with one or more IO modules. With this system, rooms can be automated in a wide variety of ways. The BAline MIO 3RPF module is an extension module for switching and controlling WWARNIN If hazard-free operation cannot be assumed, the device may not be commissioned or must be decommissioned. This assumption is justified if The housing or the supply lines show signs of damage The device is no longer working. WWARNIN For the save function of the entire plant it is necessary that the drives, motor control units and power supplies are harmonized. Therefore please contact our project management before planning! p to three 230 V AC consumers with a current conu sumption of up to 16 A (cos φ = 1) each via floating contacts. The floating relay outputs with a high current relay are suitable for lighting loads and can be loaded briefly with up to 100 A. The voltage supply of the power consumer is provided by either 230 V AC or 24 V DC. WWARNIN The control software loaded at the factory cannot be used for operation in a system. The control software loaded at the factory must be replaced by a system-related control software. With the WAREMA BAline jumper, additional modules can be connected. A maximum of 8 IO modules can be connected to the BAline basic module (e.g. BAline LONMCM). Intended use BAline MIO 3RPF is a device for controlling sun shading system and 230 V AC consumers. The approval of the manufacturer must be obtained for uses outside of the purposes listed in these instructions. Installation The module is designed for distributor installation (DIN rail-mounted housing (REG)). When installing the device in a distributor, clip it onto a symmetrical DIN rail (TH 35 according to EN 60715: 2001). To ease connection of the device, the terminal covers can be removed (see Fig. 2). Remove the terminal covers: Insert a suitable screwdriver into the notch. Fig. 2 2008423_c•en•2015-12-01 Loosening the terminal covers (DIN rail variant) We reserve the right to carry out improvements 1 Connection Technical data An on-site overload current protection device (fuse) and a disconnecting and isolating switch to switch off the entire system must be provided. BAline MIO 3RPF The module is electrically connected according to the wiring diagram on the reverse (see Fig. 5). Connection with BAline modules Connect the BAline MIO 3RPF with a BAline basic module (e.g. BAline LONMCM) or with other extension modules (Fig. 3). On the basic module, always use the connection on the right side. Min. Typ. Max. Unit Supply via jumper For relay, external connections for internal supply 20 Current consumption (24 V DC) 20 24 28 V DC 80 mA Floating outputs Switching capacity per channel at 230 V AC/cos φ 1 - - 3680 VA Switching capacity per channel at 230 V AC/cos φ 0.6 - - 2300 VA Switch on current per channel at 230 V AC - - 100 A Switching capacity per channel at 24 V DC - - 144 W Housing DIN rail-mounted housing Fig. 3 Extension module MIO 3RPF (similar figure) Initial operation After the installation has been completed and the supply voltage is applied, the device can be taken into service. For this purpose, the factory-loaded control software of the BAline MCM must be replaced by a system-related software. To create, test and load this system-related control software, use the BAline Studio PC software. After the system-related control software is loaded, the extension modules and the connected devices can be taken into service. NNOTE Take suitable precautions in order to avoid damage through electrostatic discharges! Maintenance There are no parts within the device that require maintenance. 3 MW Dimensions SeeFig. 4 Degree of protection/safety class Degree of protection, DIN rail-mounted housing IP20 Safety class II Ambient conditions Operating temperature 0 50 °C Storage temperature -25 70 °C Rel. humidity (non-condensing) 10 85 %RH Connection Supply line, drives RS485 bus, supply Outputs Max. 2.5 mm2 Software class Failure to comply with the product information in these instructions and use of the device in a manner that contravenes its intended use and purpose may result in the manufacturer refusing to honour warranty claims for product damage. In this case, liability for secondary harm to persons or damage to property will also be excluded. Conformity A Dry rooms (e.g. living areas, offices) Available at www.warema.com The device meets the EMC directives for use in residential and commercial areas. Article numbers BAline MIO 3RPF Jumper legal regulations or turned in to your local recycling centre. Jumper Miscellaneous Location of use After use, the device must be disposed of according to Screw terminals Connection terminals Liability Disposal 40 1002 945 317 943 WAREMA Renkhoff SE Hans-Wilhelm-Renkhoff Strasse 2 97828 Marktheidenfeld Germany NNOTE Not suitable for AC drives. 2 We reserve the right to carry out improvements 2008423_c•en•2015-12-01 60 mm 54 mm 3 MW Fig. 4 95 mm 90 mm 60 mm BAline MIO 3RPF 2008423_c•en•2015-12-01 We reserve the right to carry out improvements 3 The BAline 2RPF extension module permits the connection of devices with a 230 V AC power supply or devices with a safety extra low voltage (SELV) on the output side. PE Supply line 230 V AC N L to additonal components lighting 2 1 X1 Fig. 5 4 2 1 X2 2 1 X3 Wiring diagram example BAline MIO 3RPF We reserve the right to carry out improvements 2008423_c•en•2015-12-01