* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download KPT 11 KD KPT 31 KD - Schleicher Electronic
Spark-gap transmitter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electronic paper wikipedia , lookup
Stepper motor wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Current source wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electrical substation wikipedia , lookup
Schmitt trigger wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power electronics wikipedia , lookup
Power MOSFET wikipedia , lookup
Distribution management system wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Surge protector wikipedia , lookup
Voltage regulator wikipedia , lookup
Alternating current wikipedia , lookup
Network analysis (electrical circuits) wikipedia , lookup
Stray voltage wikipedia , lookup
Opto-isolator wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Buck converter wikipedia , lookup
KPT 11 KD KPT 31 KD Multi range repeat cycle timer Dual voltage 1 function: KPT 11 KD: repeat cycle starting with OFF (TP) KPT 31 KD: repeat cycle starting with ON (TI) Setting range from 0.05 s to 10 h divided into 10 time ranges 1 change-over contact 2 LEDs for function display Circuit diagram Time ranges Setting range from 0.05 s to 10 h divided into: 0.05 s … 1 s 15 s 0.15 s … 3 s 50 s 0.5 s … 10 s 0.05 h 1.5 s … 30 s 0.15 h 5s … 100 s 0.5 h … … … … … 300 1000 1 3 10 s s h h h Function Function diagrams Different OFF and ON times can be selected in decimal increments on the relay front by means of selector switches. The OFF and ON time within a range is set using the selector wheel. The different supply voltages have to be connected to their respective assigned terminal. new release: 02 December 2013 / previour release: 2010 / datasheet KPT 11 KD / KPT 31 KD / subject to change without further notice • • • • • • Dimension diagram Page 1 DZ Technical data Function display Function diagrams Power supply circuit Rated voltage UN AC/DC AC Rated consumption at 50 Hz and UN (AC) Rated consumption at 50 Hz and UN (AC) Rated consumption DC Starting current inrush stroke Rated frequency Operating voltage range A / ms Time circuit Time setting / number of time ranges Available setting range Recovery time 1/2 Minimum on time Release value Repeat cycle starting with Parallel loads permissible Internal half-wave rectification Mean value of the error Dispersion Influence of the energizing quantity, supply voltage Influence of the ambient temperature Output circuit Contact assignment Contact material Rated operating voltage Un Max. continuous current In Application category according to EN 60947-5-1:1991 Permissible switching frequency Mechanical life Response time Release time General information Creepage distances and clearances between the circuits Rated impulse voltage Overvoltage category Degree of pollution Rated voltage Test voltage Ueff 50 Hz according to DIN VDE 0110-1. table A.1 Protection degree housing/terminal according to DIN VDE 0470 sec. 1:11.92 Noise immunity according to IEC 61000-4 Ambient temperature, operating range Dimension diagram Circuit diagram Weight Accessories KPT 31 KD Electronic multi-range repeat cycle timer starting with OFF. For dual voltage. Repeat cycle relay with two different supply voltage terminals 1 green LED, 1 red LED FD 0069 Electronic multi-range repeat cycle timer starting with ON. For dual voltage. Repeat cycle relay with two different supply voltage terminals 24 V 24 V 115 V 5.5 VA 1.2 W 1.2 VA 1.0 W 0.7 W 1.5 / 2 0.5 / 2 50 – 60 Hz 0.8 – 1.1 x UN 1.2 VA 1.0 W 0.7 W 1.5 / 2 analogous/ 10 See table "Time ranges" approx. 40 / approx. 80 ms – ≥ 15 % UN OFF Yes No ≤ ± 10 % ≤ ± 0.5 % + ± 10 ms ≤ 0.005 % / % ∆ UN ≤ 0.005 % / K 230 V 7.5 VA 1.5W 0.5 / 3 42 V 60 V 1.2 VA 1.0 W 0.8 W 0.1 / 6 1.5 VA 1.3 W 1.2 W 0.05 / 10 ON 1 change-over contacts Ag alloy, gold-plated 230/230 V AC/DC 5A AC-15: Ue 230 V AC, Ie 2 A DC-13: Ue 24 V DC, Ie 2 A ≤ 6000 switching cycles/h 30 x 106 switching cycles – approx. 40 ms new release: 02 December 2013 / previour release: 2010 / datasheet KPT 11 KD / KPT 31 KD / subject to change without further notice Function type according to EN 60050 KPT 11 KD according to DIN VDE 0110-1:04.97 4 kV III 3 outside, 2 inside 250 V AC 2.21 kV IP 30 / IP 20 Test severity 3 –20 to +60 °C K1-8 W3 KS 0342/2 0.12 kg – Overview of devices / Part numbers Type KPT 11 KD KPT 31 KD Rated voltage AC/DC 24 V and AC 115 V 50-60 Hz AC/DC 24 V and AC 230 V 50-60 Hz AC/DC 42 V and AC 60 V 50-60 Hz AC/DC 24 V and AC 115 V 50-60 Hz AC/DC 24 V and AC 230 V 50-60 Hz AC/DC 42 V and AC 60 V 50-60 Hz ON-delay time See table "Time ranges" See table "Time ranges" Part No. R2.111.0019.3 R2.111.0029.3 R2.111.0039.3 R2.111.0049.1 R2.111.0059.1 R2.111.0069.1 Page 2