* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download DESCRIPTION OF SUPER SWITCH OPERATION The Super switch
Immunity-aware programming wikipedia , lookup
Phone connector (audio) wikipedia , lookup
History of electric power transmission wikipedia , lookup
Stray voltage wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Three-phase electric power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical substation wikipedia , lookup
Alternating current wikipedia , lookup
Light switch wikipedia , lookup
Crossbar switch wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Power MOSFET wikipedia , lookup
Mains electricity wikipedia , lookup
Current source wikipedia , lookup
Power electronics wikipedia , lookup
Switched-mode power supply wikipedia , lookup
DESCRIPTION OF SUPER SWITCH OPERATION The Super switch is an automatic static transfer switch designed to provide fast automatic transfers between two independent, synchronous AC power sources to provide continuity of AC power to critical equipment, such as information technology equipment. One of the two AC inputs is designated as the “preferred” source to which the super switch will connect the load as long as the designated input source is within acceptable voltage limits.If the preferred source falls outside the acceptable limits, the Superswitch is designed to transfer the output load to the other “alternate” input source, as long as the alternate source is within acceptable voltage limits and is synchronized with the preferred source within the selected phase synchronization window. The Superswitch provides fast, break-before-make transfers to prevent interconnection of the two sources, even under faulted source conditions. The maximum sense and transfer times are within the tolerance of IEEE Standard 446 susceptibility curve for information technology equipment to allow uninterrupted load equipment operation. Incase of overload, Superswitch gives the alarm. Short circuit condition of the load is protected by a fast acting semi conductor fuse.The Superswitch consists of two modules. Fixed module consists of the input and output connections and manual bypass transfer control switch. Second module is hot swappable plug in type removable electronics & static switching module. The bypass / transfer control switch is located behind a key locked hinged access cover to restrict access to qualified or designated operators. The plug in module likewise contains key locked latches to prevent unauthorized removal of the module. The Superswitch is designed to allow replacement of the removable electronics /switching module without having to deenergize the load equipment.The Superswitch has a live mimic to display the current status of the unit. This mimic is located on the removable electronics module. Mimic is active as long as at least one source is on.The fixed module of the Superswitch also has live mimic indicating the status ofsource & load even if hot swappable electronic module is removed. SUPER SWITCH TECHNICAL SPECIFICATIONS 1 : GENERAL SPECIFICATIONS • • • • • • • • • • • 2 Manual and Automatic Transfers. Sense and transfer time: Less than 6 milliseconds. Break-Before Make-switching. Selectable Preferred Source. Selectable Auto/Manual Retransfer. In-Phase Transfer Window: Adjustable from 20 V to 100 V Convection cooling. Hot swappable electronic static switching module Live mimic on electronic static switch module for indicating load supply status & alarms. Live mimic on fixed module to indicate supply status even with electronic module removed. Make before break manual bypass switch to transfer load from static switch to direct source 1 or source 2. : ELECTRICAL SPECIFICATIONS • • • • • • • • • • • Nominal Input Voltage 220, 230 or 240 volts singe phase, 2W+G, 50 Hz. Solidly grounded power sources. Source unhealthy status – Adjustable from -10 to –20 % of nominal voltage Maximum continuous source 25 A, 50 Hz Load Power factor range: 0.5 to 1.0 leading or lagging Load Crest factor: up to 3.5. Source voltage distortion: up to 10% THD Overload capability: 125% of continuous current for 2 hours, 1000% for two cycles minimum. Over current Protection: By semi conductor fuse Short circuit withstand capability: up to 20,000 symmetrical amps, protected by internal fusing. Redundant Control Power supplies. Integral Maintenance Bypass. • 3 Eight Isolated Normally Open alarm & static switch Status Contacts. : ENVIRONMENTAL SPECIFICATIONS • • • • • • Storage temperature range - -40 to +60 Operating temperature range – 0 to 40 C Relative Humidity – 0 to 95 % without condensation Operating Altitude – up to 5000 feet (1500 meters) above sea level without derating. Storage / Transport Altitude – up to 40,000 feet (12,000 meters) above sea level. Audible Noise – less than 45 dBA at 5 feet (1.5 meters). DESCRIPTION OF SUPERSWITCH OPERATION The Superswitch is an automatic static transfer switch designed to provide fast automatic transfers between two independent, synchronous AC power sources to provide continuity of AC power to critical equipment, such as information technology equipment. One of the two AC inputs is designated as the “preferred” source to which the superswitch will connect the load as long as the designated input source is within acceptable voltage limits. If the preferred source falls outside the acceptable limits, the Superswitch is designed to transfer the output load to the other “alternate” input source, as long as the alternate source is within acceptable voltage limits and is synchronized with the preferred source within the selected phase synchronization window. The Superswitch provides fast, break-before-make transfers to prevent interconnection of the two sources, even under faulted source conditions. The maximum sense and transfer times are within the tolerance of IEEE Standard 446 susceptibility curve for information technology equipment to allow uninterrupted load equipment operation. In case of overload, Superswitch gives the alarm. Short circuit condition of the load is protected by a fast acting semi conductor fuse. The Superswitch consists of two modules. Fixed module consists of the input and output connections and manual bypass transfer control switch. Second module is hot swappable plug in type removable electronics & static switching module. The bypass / transfer control switch is located behind a key locked hinged access cover to restrict access to qualified or designated operators. The plug in module likewise contains key locked latches to prevent unauthorized removal of the module. The Superswitch is designed to allow replacement of the removable electronics /switching module without having to deenergize the load equipment. The Superswitch has a live mimic to display the current status of the unit. This mimic is located on the removable electronics module. Mimic is active as long as at least one source is on. Fig. 1 indicates the status and alarm indicators in mimic. The fixed module of the Superswitch also has live mimic indicating the status of source & load even if hot swppable electronic module is removed. This is also indicated clearly in Fig 1.