Survey
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
Public address system wikipedia , lookup
Loading coil wikipedia , lookup
Phone connector (audio) wikipedia , lookup
Mains electricity wikipedia , lookup
Power over Ethernet wikipedia , lookup
Invention of the telephone wikipedia , lookup
Electrical connector wikipedia , lookup
Rectiverter wikipedia , lookup
Telephone Line Monitor USER GUIDE For Technical Assistance Please Phone: (07) 5596 5128 PACKING LIST ITEM QTY TLM Telephone LIne Monitor 1 Telephone Line Connection Cable 1 Accessory Device Connection Box 1 12V Power Adaptor 1 TLM is supplied with a TWO YEAR Warranty. Page 2 National Communications DESCRIPTION Our Telephone Line Monitor (TLM) device is designed to activate whenever the Telephone Line that it is connected to has been disconnected or cut. TLM is totally ‘Transparent’ in operation and will not affect the use of the Telephone Line in any way. TELEPHONE LINE DISCONNECTION TLM’s main role is to constantly monitor the Telephone Line that it is connected to and only respond when the telephone line connected to it has been disconnected or cut, which is detected by a loss of Telephone Line Voltage. In the event that this happens, TLM will automatically CLOSE the contacts of an Internal Relay, which in turn are used to trigger other external equipment to advise of the loss of Telephone Line. TLM’s Internally Relay has Dry Relay Contacts, rated at 12V/1A. Three low cost Accessories are available from Natcomm for use with TLM, to alert the User that the Telephone Line has been lost. These Accessory Devices are all designed for Easy User Installation. See page 5 for further details. The Relay Output of TLM can alternatively be used to Control a 3rd Party Electrical Device (not supplied). An Accessory Device Connection box (with 2 screw terminals) is supplied for this purpose and connects to TLM via a short supplied cable. OFF HOOK DETECTION In addition to its main function, TLM can also be set to indicate when a Telephone Line is in use (Line is ‘Off Hook’). This facility is normally disabled, but can be enabled by turning ON One or Two Dip Switches located on the underside of the unit (see page 11 for details). TLM can be set to indicate when : * An Attached device goes ‘Off Hook’. * A device connected in ‘Parallel’ goes ‘Off Hook’. * Both of the above * Neither of the above National Communications Page 3 DESCRIPTION Continued TELEPHONE LINE CONNECTION TLM can be connected to ANY Telephone Socket on the Telephone Line. If another Telephone Device is to be used on the same Telephone Socket, then it can either be connected using a Double Telephone Adaptor (not supplied) or it can be connected to the LINE OUTPUT Port of TLM. POWERING TLM A 12VAC Power Adaptor is supplied with TLM. It can also be operated from a 12VDC source, with a minimum capacity of 200mA. If an alternative 12VDC source is used, polarity is not important. OPERATION WITH ADSL TLM can operate on a Telephone Line which also has an ADSL service. TLM will operate correctly, with or without ADSL Filtering. If a separate Telephone Device is connected to the TELEPHONE LINE OUTPUT port of TLM, then it will be necessary to have an ADSL FILTER fitted ahead of the TLM device. Page 4 National Communications OPTIONAL ACCESSORIES The Internal Relay of Telephone Line Monitor (TLM) can be used to control one of Three low cost accessories available from Natcomm. 1) Mini Strobe Light (blue) This accessory connects direct to TLM with a supplied junction box and cable. A 10 meter cable is supplied to allow the Strobe Light to be located remote from TLM. The cable can be easily shortened or extended if required. Important Note : The polarity of the 2 wires used for this accessory is important and damage will result if the supplied Red and Red/Black wires are mixed. It uses 6 high brightness LEDs to provide a SUBTLE but EFFECTIVE indication that the telephone line has been cut, disconnected or is in use. It can be wall or ceiling mounted using the supplied screws or by using double sided tape. Flash rate: 60-90 per minute. 1 Watt. See page 8 for further information. 2) Siren Speaker with Volume Control The SIREN accessory outputs up to 110dB and is therefore suitable for small factories. A volume adjustment knob allows for the ideal volume to be set for individual environments. A 10 meter cable is supplied to allow the Siren Speaker to be located remote from TLM. The cable can be easily shortened or extended if required. Important Note : The polarity of the 2 wires used for this accessory is important and damage will result if the supplied Red and Red/Black wires are mixed. 3) Power Control Unit Our Power Control Unit accessory, will allow ANY 240V Electrical Device (max 10A) to be connected direct to it. This means that you can use ANY desired Electrical Device to Indicate that your telephone line has been cut, disconnected or is in use. Power Control Unit connects direct to ANY Electrical Wall Socket. Your Desired Electrical Device then connects to it via a normal extension cable socket. See page 7 for further information. National Communications Page 5 INSTALLATION INSTRUCTIONS 1. TELEPHONE LINE CONNECTION Connect the TELEPHONE LINE INPUT port of TLM to any telephone socket on the telephone line, using the supplied telephone cable. If another telephone device is also fitted to the same telephone socket, then you should connect both devices to the same socket using a Double Telephone Adaptor (not supplied). 2. ACCESSORY DEVICE CONNECTION (Light, Loud Siren or other device) If you are connecting a NATCOMM Accessory, refer to page 7. If you are connecting a THIRD PARTY ELECTRICAL Accessory: An interface box with 2 screw terminals is supplied to provide a convenient means of connecting your Electrical Device to the Relay contacts located within TLM. A short connection lead is also supplied to connect the connection box to TLM. Important Note : The Dry Contact Relay within TLM is rated at 12V and 1Amp. If you exceed either of these parameters, permanent damage will result. 3. OFF HOOK INDICATION If you ALSO require OFF HOOK indication, set Dip Switches 1 & 2 as per the details on page 11. 4. POWER ADAPTOR CONNECTION CONNECT the supplied 12VAC Power Supply and switch it ON. Page 6 National Communications NATCOMM ACCESSORY 1) Mini Strobe Light (blue) The Siren accessory connects to the Relay Output port of TLM via the ‘Connection Box’ and short cable supplied with this accessory. A 10 metre cable is supplied with this accessory that can be shortened or lengthened as necessary (wire is important please see bold section below). Adjust the volume to suit with the volume POT. Please Note : Wiring polarity IS VERY important for this Accessory. Permanent damage will result if the polarity of the Red and Red/Black wires is not maintained. 2) Siren Speaker with Volume Control The Strobe Light accessory connects to the Relay Output port of TLM via the ‘Connection Box’ and short cable supplied with this accessory. A 10 metre cable is supplied with this accessory that can be shortened or lengthened as necessary. Please Note : Wiring polarity IS VERY important for this Accessory. Permanent damage will result if the polarity of the Red and Red/Black wires is not maintained. 3) Power Control Unit The Power Control Unit accessory connects to the Relay Output port of TLM via the curly cord cable supplied with this accessory. National Communications Page 7 STROBE LIGHT INSTALLATION A white connection box is supplied to allow for easy user connection of this accessory. The box has two leads connecting from it : STEP 1. The short Cream coloured telephone cable with the RJ plug should be plugged into the Relay Output port of TLM. STEP 2. A 10m figure 8 cable with Red and Red/Black wire, is supplied connected to the Positive (Red) and Negative (Red/Black) wires of the Strobe Accessory, using a connection block. You can lengthen or shorten this cable, but it is VERY IMPORTANT that you maintain polarity of the wires. The Red wire from the Connection Box must connect to Red wire connected to the Strobe Accessory only. The Black/Red wire (Red wire with Black stripe) from the Connection Box must connect to Black wire connected to the Strobe Accessory only. Polarity is important. Failure to maintain polarity will cause fatal damage to the Strobe Accessory. Page 8 National Communications SIREN INSTALLATION A white connection box is supplied to allow for easy user connection of this accessory. The box has two leads connecting from it : STEP 1. The short Cream coloured telephone cable with the RJ plug should be plugged into the Relay Output port of TLM. STEP 2. A 10m Red and Black figure 8 cable is supplied connected to the Positive (Red) and Negative (Black) wires of the Siren Accessory, using a connection block. You can lengthen or shorten this cable, but it is VERY IMPORTANT that you maintain polarity of the wires. The Red wire from the Connection Box must connect to Red wire connected to the Siren Accessory only. The Black/Red wire (Red wire with Black stripe) from the Connection Box must connect to Black wire connected to the Siren Accessory only. Polarity is important. Failure to maintain polarity will cause fatal damage to the Siren Accessory. National Communications Page 9 POWER CONTROL UNIT AS/NZS3260 Approval Number Q00217 Our POWER CONTROL UNIT (PCU-2) accessory will allow you to use a 120VAC to 240VAC Electrical Device ( such as a Light, Horn or a Loud Siren) to INDICATE when your telephone line is ‘Off Hook’. It is designed for quick and easy USER INSTALLATION. It has a standard AC Male Power Plug connected to a short cable. This AC Male Power Plug should connect to a Wall Power Socket. It also has a standard AC Female Power Socket connected to a short cable. This AC Female Power Socket should connect to the AC Male Power Plug of your Electrical Device. Your can connect TWO or more devices to POWER CONTROL UNIT if required. It is designed to operate up to 10Amps in total. A curly cord cable with RJ 4 pin connectors is supplied with your POWER CONTROL UNIT. One end of this cable plugs into POWER CONTROL UNIT and the other end plugs into the RELAY OUTPUT port of your TLM. PCU-2 is set up in a NORMALLY OFF configuration, which means that the electrical equipment connected to this device will be SWITCHED OFF at all times, until your TLM provides a relay closure. TLM will then provide the relay closure whenever the telephone line is ‘Off Hook’. Page 10 National Communications DIP SWITCH SETTINGS Four micro Dip Switches are located on the underside of TLM. Dip Switches 1 and 2 should ONLY be Switched ON if you ALSO want TLM to Indicate when your Telephone Line is IN USE. If you DO NOT WANT this facility, please leave Dip Switches 1 and 2 set to the OFF position. Dip Switches 3 and 4 are NOT OPERATIONAL. DIP SWITCH 1 If you want TLM to Indicate that a ‘Parallel’ connected Telephone Device (ie Not attached direct to its Telephone Line Output port) is in Use or ‘Off Hook’, please set Dip Switch 1 to the ON position. DIP SWITCH 2 If you want TLM to Indicate that a Telephone Device attached direct to its Telephone Line Output port is in Use or ‘Off Hook’, please set Dip Switch 2 to the ON position. The default Dip Switch settings are : SW1 = OFF SW2 = OFF SW3 = OFF SW4 = OFF National Communications Page 11 SPECIFICATIONS Dimensions (all in mm) Weight Power Supply Power Consumption Ringer Equivalence Telephone Input Connectors Relay Output Connector: Power Input Connector ACMA COMPLIANCE : : : : : : : : : : 106 (W) x 106 (D) x 43 (H) 200g 240VAC to 12VAC/300mA When Idle - 0.5 Watts During Call - 0.75 Watts 0.3 REN RJ 11 - 6 pin (2 centre) RJ 4P4C (2 centre) 2.5mm barrel connector Supplier Number N782 WARRANTY This device is guaranteed against defects from workmanship for a period of two years (24 months) from the date of purchase. In the event of failure, you should return the product, along with proof of purchase date, and a written statement about the nature of the problem. This Warranty shall not apply to any unit which has been subject to alteration, modification, abuse, negligence, accident, external voltage/ lightning surge or used in any manner contrary to these instructions. The obligation is solely to repair or replace the product. The warrantor is not liable for any incidental or consequential damages due to such defects. The user is responsible for freight costs to the repair point. The warrantor will be responsible for freight costs in returning this unit back to the user. Damage caused to this device or attached equipment, by lightning strikes or over voltage surge is not covered under this warranty. CASE SEALED AT FACTORY OPENING THE CASE VOIDS THE WARRANTY Page 12 National Communications