Download Test equipment : Clamp-on

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Stepper motor wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Alternating current wikipedia , lookup

Stray voltage wikipedia , lookup

Buck converter wikipedia , lookup

Sound level meter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Distribution management system wikipedia , lookup

Metadyne wikipedia , lookup

P–n diode wikipedia , lookup

Opto-isolator wikipedia , lookup

Test probe wikipedia , lookup

Peak programme meter wikipedia , lookup

Rectifier wikipedia , lookup

Portable appliance testing wikipedia , lookup

Ohm's law wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Multimeter wikipedia , lookup

Transcript
Test equipment : Clamp-on-meters SC77
?
Clamp-on-meters SC77
Part number: 13278
Rating: Not Rated Yet
Price
Ask a question about this product
Description
All-in-one meter for the HVAC/R technician.
SC66 and SC67 are manual ranging. SC76 and SC77 are autoranging and work with Fieldpiece accessory heads. SC77 has true RMS and
blacklight.
The SC76 and SC77 have removable probe tips and mVDC ranges which allow the meters to connect to any of our accessory heads. The
meters expand to keep up with your measurement needs.
TECHNICAL SPECIFICATIONS:
- Non-contact Voltage (NCV); the presence of 24VAC triggers a loud beeper and bright LED.
- Temperature; Thermocouples allow for real-time accurate temperature measurement.
- Microamps; For flame rectifier diode tests.
- Capacitance; For motor-run and motor-start capacitors.
- And more;
blackligth for viewing display in the dark true RMS for true power calculations.
LED and beeper turn on to indicate you’ve touched potentially dangerous voltage. Continuity indicated by LED and beeper
Hold saves readings so you can look at them even after the meter has been disconnected. Ohm ranges for motor windings and other HVAC/R
applications.
Amps AC resolution to 0.01A for heat anticipator circuit (20A range).
Auto-power off to extend battery life.
1 / 2
Test equipment : Clamp-on-meters SC77
The padded ANC7 case is included with every SC60 and 70 series meter. It has a zippered pocket and a belt loop on the back.
Also included are silicone test leads, alligator clips (SC76 and SC77), ATB1 K-Type thermocouple, 9V battery (installed), and operator’s