* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download ZODIAC DATA SYSTEMS
UniPro protocol stack wikipedia , lookup
Cellular repeater wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Serial digital interface wikipedia , lookup
Power electronics wikipedia , lookup
Phase-locked loop wikipedia , lookup
Superheterodyne receiver wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Oscilloscope wikipedia , lookup
Oscilloscope history wikipedia , lookup
Analog television wikipedia , lookup
Radio transmitter design wikipedia , lookup
Telecommunication wikipedia , lookup
Broadcast television systems wikipedia , lookup
Valve RF amplifier wikipedia , lookup
Index of electronics articles wikipedia , lookup
Rectiverter wikipedia , lookup
Oscilloscope types wikipedia , lookup
Tektronix analog oscilloscopes wikipedia , lookup
Opto-isolator wikipedia , lookup
ZODIAC DATA SYSTEMS ZODIAC AIRCRAFT SYSTEMS HEIM DATaRec® 4 series Technical Specifications DIC24 DC The DIC24 DC module can record 24 analog channels (up to 24 x 20 kHz analog bandwidth, maximum sampling rate is 50 kHz; all 24 channels must have the same bandwidth). Total Harmonic Distortion (THD)≤-100 dB, typ. <-108 dB at 2 Vpeak Range, 32 bit mode, Signal 1 kHz Sine -1 dBFS, 24 °C Spurious-Free Dynamic Range (SFDR) incl. Harmonics DIC24 DC (HS310-0125) ≥100 dB, typ. >110 dB at 2 Vpeak Range, 32 bit mode, Signal 1 kHz Sine -1 dBFS, 24 °C 24-Channel Voltage Module (single ended) Number of channels 24 excl. Harmonics Operating mode Record (no E to E) Input signal Single ended analog voltage ≥120 dB, typ. >124 dB at 2 Vpeak Range, 32 bit mode, Signal 1 kHz Sine -1 dBFS, 24 °C Sampling frequency (Fs) 100 Hz to 50 kHz, settable in steps of 1 Hz (For use in a Link chain configuration the sampling frequency must be a binary divider of the overall system Fs) Connector Analog input: 1 * 50 pin D-Sub Functions Sampling ratio 2.5; no mirroring effect Integrated calibration unit 1 ppm reference calibration Analog bandwidth Max. 20 kHz (settable) Galvanic isolation Resolution 16 bit/32 bit Input signal range ± 10 mVpeak to ± 10 Vpeak (settable in steps) Between analog and digital layer inside of the module and between modules Max. isolation voltages Power input to digital part: 48 V DC accuracy ± 0.1 % or ± 1 mV Signal coupling DC Input impedance Power input to analog part: 48 V Digital part to analog part: 48 V Input channel voltage safety 1 MΩ ± 35 V Phase accuracy between two modules ≤ 0.3° by same sampling frequency and until 20 kHz bandwidth ≤ 1° by different sampling frequency Phase accuracy ≤ 0.2° Analog to digital converter 24 bit Signal to Noise Ratio (SNR) ≥92 dB, typ. >98 dB at 2 Vpeak Range, 32 bit mode, Signal 1 kHz Sine -1 dBFS, 24 °C © ZODIAC Data Systems GmbH Page 1 of 2 Document No.: TS_DIC24_DC_140401_HD5431041R00616.fm All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice. HEIM DATaRec® 4 series Technical Specifications DIC24 DC Additional Infos Synchronicity of samples Environmental specifications In a Link chain configuration with several analog modules the sample synchronicity of all modules depends on the sampling frequencies of each module. For sample synchronicity the module sampling frequency must be a multiplier of 2 to the power of n (Fs x 2n; n = wholenumbered) of each other module sampling frequency. Example: One module sampling frequency (Fs) = 4kHz. Sampling frequency of all other modules must be one of the following: 4kHz x 20 (= 4kHz), 4kHz x 21 (= 8kHz), 4kHz x 22 (= 16kHz), 4kHz x 23 (= 32kHz), 4kHz x 24 (= 64kHz), and so on; or 4kHz x 2-1 (= 2kHz), 4kHz x 2-2 (= 1kHz), 4kHz x 2-3 (= 0.5kHz), 4kHz x 2-4 (= 0.25kHz), and so on. General Dimensions Vibration 5g Shock 10 g Temperature According to standard IEC 60068-2-14-Nb Operation as standalone -20 °C ...+70 °C -30 °C ...+70 °C Special start-up procedure required Operation in a Link chain -10 °C ...+55 °C -20 °C ...+55 °C Special start-up procedure required Storage -40 °C ...+85 °C Humidity 0 ...93% relative, non-condensing EMI DIN EN61000-6-4 / DIN EN61326-1 For operation in industrial environment (according to DIN EN 61326) earthing of the module and / or shielded cable is necessary to prevent influences by external electromagnetic distortions Notes Standard HEIM DATaRec 4 housing. 48.1 x 184 x 124.5 mm (w x h x d) including fixing system Performance varies depending on the installation environment. The shown values were measured using an appropriately designed test system including the HEIM DATaRec® 4 power supplies under nominal conditions of temperature, voltage, etc.. Weight 1100 g typical Cooling Conduction cooled Power consumption 15 W typical Performance is significantly influenced by storage medium type, host computer performance and load, used acquisition software, signal module configuration, power supplies and cabling. Power input range 17 ...28 V DC (via appropriate DATaRec® 4 System Power Module) Definitions Specifications with limiting symbols (<, >, ≤, ≥, ±, min, max, etc.) or a bandwith (x ...y) represent performance within a range of values. Input DC power Low power detection Communication HeimLink, USB 2.0 and RS232; Display, Button, LED. Specifications named as „typical“ represent performance met by approximately more than 80% of the specification basis (channels, produced devices, etc.). Specifications without limits are nominal values or values within standard tolerances (e. g. dimensions, sampling rates etc.). ZODIAC Data Systems GmbH Friedrich-Ebert-Strasse / TechnologiePark – D-51429 Bergisch Gladbach Tel.: +49 2204 84 41 00 – Fax: +49 2204 84 41 99 [email protected] – http://www.zodiac-data-systems.com © ZODIAC Data Systems GmbH Page 2 of 2 Document No.: TS_DIC24_DC_140401_HD5431041R00616.fm All trademarks acknowledged. ZODIAC Data Systems GmbH reserves the right to amend these specifications without notice.