Download Voltage and Current Relay Monitoring Relay NMI 1001 Current

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Islanding wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Current source wikipedia , lookup

Ohm's law wikipedia , lookup

Electrical substation wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Surge protector wikipedia , lookup

Rectifier wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Power electronics wikipedia , lookup

Schmitt trigger wikipedia , lookup

Relay wikipedia , lookup

Power MOSFET wikipedia , lookup

Voltage optimisation wikipedia , lookup

Metadyne wikipedia , lookup

Current mirror wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Protective relay wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Buck converter wikipedia , lookup

Transcript
Voltage and Current Relay
Monitoring Relay
NMI 1001
PI 0095-1103 E
Current monitoring relay for single-phase
AC/DC networks
Function acc. DIN EN 60255-6: 11.94
•
•
•
•
•
•
Monitoring of single-phase current from
AC/DC 0,02 A to AC/DC 0,5 A
AC/DC 1 A to AC/DC 15 A
Reaction to overrange or underflow of the response value
Closed-circuit principle or open circuit principle adjustable
Hysteresis 3 % or 10 % adjustable
On-delay time tA adjustable ( from no delay "-" to 3 h at 16 time ranges)
Wide 22,5 mm
Front View
LED SUPPLY green, power supply
LED TRIPPED red, on-delay time tA (flashing)
1
gg
Device description
The NMI 1001 is a monitoring relay with three measurement ranges for singlephase currents. There are two types with different measuring ranges. The
frequency range is of 45 Hz to 400 Hz. The monitoring value is operated with
an integrating full wave rectification. Through this the monitoring of no sinusoidal voltage is possible (e.g. voltage with harmonic component). At AC, the
devices value at a rectifier value calibrated on the root-mean-square of a sine
voltage. At DC, a rectification is carried out and the mean value is monitored.
The effective value itself isn't monitored. As output contact 1 change-over
contact is available. There is a isolation between the auxiliary supply, the
measuring circuit and the output circuit (relay contact).
Function description
The measurement ranges are adjusted by the different connection of the terminals B1, B2, B3 and B4.
The response value is adjusted with the potentiometer Ix, the functions and the
on-delay time are adjusted with the rotary switches (see tables the next page).
Function Open Circuit Principle
After applying the supply voltage and transgression of the upper or lower limit
values of the adjusted response value (depending on the function selection)
the output relay switches into the on-position. This occurs according to the
adjusted on-delay time. The transgression of the upper or lower limit values of
the response value (depending on the adjustment and hysteresis), causes the
output relay to go back into the off position.
Function Closed Circuit Principle
After applying the supply voltage, the output relay switches after tB in the
active position. The transgression of the adjusted upper or lower limit value,
according to the adjusted function, causes the output relay (depending on the
adjusted on-delay time) to switch back into the off-position. Depending on the
adjusted hysteresis, the output relay switches back into the active position
after the respective transgression of the upper or lower limit of the response
value.
Proper Use / Intended Purpose
The NMI 1001 is used to monitoring current levels in switchplants.
Note
Disconnect the connecting lines of the NMI 1001 before execute voltage or
insulation tests in the switchplant.
Observe all relevant regulations and standards.
1/5
Voltage and Current Relay
Monitoring Relay
NMI 1001
PI 0095-1103 E
Monitoring ranges NMI 1001 0,02 - 0,500 A
Range
Terminal
Response value
Internal resistance
1
2
3
B1 - B2
B1 - B3
B1 - B4
2,5 Ω
500 mΩ
100 mΩ
2 -20 mA AC/DC
10 - 100 mA AC/DC
50 - 500 mA AC/DC
Monitoring ranges NMI 1001 0,1 - 15 A
Range
Terminal
Response value
1
2
3
B1 - B2
B1 - B3
B1 - B4
0,1 - 1 A AC/DC
0,5 - 5 A AC/DC
1,5 - 15 A AC/DC
Internal
resistance
50 mΩ
10 mΩ
3,33 mΩ
Permissible overcurrent
max. 3 s
max. 10 ms
Pause 100 s
Pause 100 s
0,05 A
0,2 A
0,5 A
0,25 A
1A
2,5 A
1,25 A
5A
12 A
Max. fusing (slow)
Permissible overcurrent
continuously
max. 3 s
max. 10 ms
Pause 100 s
Pause 100 s
2,5 A
10 A
25 A
12,5 A
50 A
125 A
21 A
50 A
125 A
Max. fusing (slow)
dauernd
0,1 A
0,4 A
2,5 A
5A
16 A
25 A
Response values
Potentiometer Ix
Response value analog adjusting with potentiometer as factor in the range from 0,1 to 1.
Response value = upper limit of measuring range x adjusted factor
Functions
Rotary switch MODE HYSTERESIS CURRENT
CURRENT I
> 10
Overrange
> 10
Overrange
> 3
Overrange
> 3
Overrange
< 10
Underflow
< 10
Underflow
< 3
Underflow
< 3
Underflow
- - -
HYSTERESIS
ca. 10 %
ca. 10 %
ca. 3 %
ca. 3 %
ca. 10 %
ca. 10 %
ca. 3 %
ca. 3 %
-
MODE
Open circuit principle
Closed circuit principle
Open circuit principle
Closed circuit principle
Open circuit principle
Closed circuit principle
Open circuit principle
Closed circuit principle
-
On-delay time
Rotary switch ON-DELAY
0,1 s
0,3 s
0,5 s
1s
1,5 s
3s
5s
10 s
30 s
100 s
3 min
10 min
30 min
1h
3h
- (no delay)
Note
•
During timing period, a operation of the function rotary switch or the on-delay rotary switch immediately terminates the timing operation.
•
With no delay " - " and simultaneous active function overflow, the NMU 1001 react from a certain threshold of the instantaneous value of the monitoring
value and the output relay switched very rapidly in "quick time" ( see also technical data at monitoring circuit, response time).
2/5
Voltage and Current Relay
Monitoring Relay
NMI 1001
PI 0095-1103 E
Function diagram
Power supply
LED SUPPLY
Monitoring value
(Operating mode
overflow of the response value >)
Response val.
Hysteresis
Monitoring value
(Operating mode
underflow of the
response value <)
Hysteresis
Response val.
LED TRIPPED
Output contact
Open circuit principle
Output contact
Closed circuit princ.
15/18
15/16
15/18
15/16
tB Stand-by time, tA Response time
Application examples
NMI 1001 0,02 -- 0,5 A:
Response value
50 mA AC/DC
On-delay time
100 s
Function
overrange, 3 % hysteresis, open circuit principle
Settings
•
Measuring range 10 to 100 mA (terminal B1 / B3)
•
Poti Vx at 0,5 (0,5 x upper limit of measuring range 100 mA) = 50 mA
•
Rotary switch ON DELAY at 100 s
•
Function rotary switch at > 3
Description
If the monitoring value exceeds the response value of 50 mA, the LED TRIPPED begins to
flash. After the preselected on-delay time 100 s the output relay switches into its active
position and the LED TRIPPED lights up continuously.
If the actual monitoring value falls below the response value minus the hysteresis of 3 %,
the output relay switched back into its off-position.
If falls below before the on-delay time is reached, the LED TRIPPED goes out - see function
diagram.
NMI 1001 1 -- 15 A:
Response value
On-delay time
Function
12 A AC/DC
no
underflow, 10 % hysteresis, closed circuit principle
Settings
•
Measuring range 1,5 to 15 A (terminal B1 / B2)
•
Poti Vx at 0,8 (0,8 x upper limit of measuring range 15 A) = 12 A
•
Rotary switch ON DELAY at " - " (no delay)
•
Function rotary switch at < 10
If the measuring value falls below of the response value of 12 A, the output relay switched
into its off-position without a on-delay time, and the LED TRIPPED lights up.
If the actual measuring value exceeds the response value plus the hysteresis of 10 %, the
output relay goes in its operating position. The LED TRIPPED goes out - see function diagram.
3/5
Voltage and Current Relay
Monitoring Relay
NMI 1001
PI 0095-1103 E
Technical Data
Power circuit
Rated voltage UN
Rated consumption at 50 Hz and UN
Rated consumption at 50 Hz and UN
Maximum in rush current at UN (< 1 ms)
Rated frequency
Operating voltage range
Parallel permitted loads
Monitoring circuit (DC or sinusoidal measuring voltage)
Isolation to power circuit
Setting range hysteresis
Dispersion
Rated frequency range of response value
Minimum pulse length of response value
Minimum pulse length of response value at NO DELAY "-"
Time circuit
Dispersion
Influence of supply voltage
Influence of ambient temperature
Output circuit
Contact equipment
Contact material
Rated operating voltage
Rated value of maximum continuous current Ith
Minimal contact load
Application category acc. to EN 60947--5--1:1991
Permissible switching frequency
Mechanical lifetime
Electrical lifetime 20/2 A, AC 250 V, cos ϕ = 0,3
Response time at "-" and function ">" (AC 50 Hz)
Response time at "-" and function ">" (DC)
Off-delay time at "-" and function ">"
Off-delay time at 0,1 s to 3 h
Minimum pulse time of output relay
Availability time of measurement tB after switch-on of supply
Override time of measurement after switch-on of supply
General data
Rated voltage
Rated impulse voltage
Over voltage category
Test voltage current circuits
Test voltage contact/contact
Protection class housing/terminals acc. to DIN VDE 0470 sec. 1:11.92
Isolation
Contamination level
Ambient temperature, working range
Weight
Approvals
Terminal data and connection data
Rated insulation voltage
Screw / thread
Screwhead
Stud torque
Rated connecting ability
rigid (single-core or multi-core) / flexible
flexible with wire-end ferrule
AWG
Multi-wire connection
rigid (single-core or multi-core) / flexible
flexible with wire-end ferrule
DC 24 V
-1W
1A
50 Hz to 60 Hz
0,8 to 1,1 x UN
yes
AC 24 V
2,5 VA
2,3 W
1,2 A
AC 115 - 120 V
2,5 VA
2,3 W
0,25 A
AC 230 - 240 V
2,5 VA
2,3 W
0,13 A
yes
3 % appr. or 10 % appr. of response value, adjustable
≤ ± 0,5 %
≤ ± 0,05 % / % ∆UN
≤ ± 0,0 5 % / K∆T
45 Hz -- 400 Hz
25 ms with overrange/underflow of the DC response value
1 ms with 1,5 times overrange of the DC response value
≤ ± 0,2 % + ≤ 50 ms
≤ ± 0,02 % / % ∆UN
≤ ± 0,005 % / K∆T
1 changeover contact
Ag -- alloy, gold-plated
AC/DC 240 V
5A
≥ AC/DC 5 V / ≥ AC/DC 10 mA
AC--15: Ue 230 V, Ie 3 A, DC 13: Ue 24 V, Ie 2 A
≤ 3600 switching cycles/h
30 x 106 switching cycles
0,12 x 106 switching cycles AC-15
≤ 80 ms at 1,05 times response value
≈ 25 ms at 1,3 times response value (quicktime)
≤ 50 ms at 1,1 times response value
≈ 15 ms at 1,6 times response value (quicktime)
≈ 30 ms after 1,1 times response value
≤ 150 ms after 1,6 times response value
≈ 30 ms after 1,1 times response value
≈ 35 ms ater 1,6 times response value
> 100 ms,
≤ 100 ms
≤ 60 ms
500 V
5 kV (1,2 / 50 µs); 4 kV (1,2 / 50 µs) at DC 24 V device
III
2,7 kVeff (50 Hz)
2,5 kVeff (50 Hz)
IP 40 / IP 20
acc. to VDE 0110 section 1, 2 : 01.89
3 outside, 2 inside
-20°C to +60
0,2 kg
CULUS
500 V
never lost / M3
M3, +/- Pozidrive 1, slot for screwdriver 0,8 x 4,8 mm²
max. 1 Nm
0,2 - 6 mm² / 0,2 - 4 mm²
0,2 - 4 mm²
24 - 10
2 wires with the same cross section
0,2 - 2,5 mm² / 0,2 - 2,5 mm²
0,2 - 1,5 mm²
4/5
Voltage and Current Relay
Monitoring Relay
NMI 1001
PI 0095-1103 E
Connection Diagram
Assembly
1
Attach relay to DIN rail.
Disassembly
3
Push relay down (in direction of
arrow)
2
Press the relay carefully onto the
DIN rail (in direction of arrow) until it
locks into place.
4
Release relay and remove it from
the DIN rail (see arrow)
Dimension Diagram
Subject to Change
SCHLEICHER Electronic
GmbH & Co. KG
Pichelswerderstraße 3-5
D-13597 Berlin
Ph ++49.30.33005.0
Fx ++49.30.33005.344
Hotline ++49.30.33005.304
www.schleicher-electronic.com