* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download code Description Technical specifications DL 2309B SPEED
Electrical ballast wikipedia , lookup
Electric power system wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Brushless DC electric motor wikipedia , lookup
Power engineering wikipedia , lookup
Control system wikipedia , lookup
Electric motor wikipedia , lookup
Electric machine wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Dynamometer wikipedia , lookup
Electrification wikipedia , lookup
Three-phase electric power wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Utility frequency wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Opto-isolator wikipedia , lookup
Voltage optimisation wikipedia , lookup
Alternating current wikipedia , lookup
Stepper motor wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Induction motor wikipedia , lookup
Buck converter wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Mains electricity wikipedia , lookup
Switched-mode power supply wikipedia , lookup
code DL 2309B Description SPEED CONTROL OF AC MOTORS Technical specifications Didactic equipment: electronic frequency converter for the open and closed loop speed regulation of a threephase induction motor. Potentiometers for speed setting and acceleration and deceleration ramps. Reversal in the direction of rotation. Technical features: Power: 4 kW - Nominal current: 9 A -Output frequency: 0 to 240 Hz -Dynamic braking Complete with analogue meter for rotating speed and with electronic protections against overvoltage, maximum current and over temperature. The ac motor speed control system must consist in a full digital controlled inverter and it must offer the following capabilities: a) speed regulation by keyboard or external potentiometer; b) acceleration and deceleration times by keyboard or external potentiometers; c) torque increase at low frequency (boost) to compensate for the resistive losses in the motor; d) dc braking. Moreover the following protections must be provided: a) mains overvoltage; b) motor overcurrent; c) solid state short circuit output protection. All the parameters must be easy programmable by a keyboard The module must include the following Sections: Power supply section: module supplied at single-phase supply through the power cord to beconnected to the rear socket and the magnetothermic differential switch on the rear. Driving section: including Key switch; Push button "start"; Push button "stop"; Switch "JOG"; Switch "cw/ccw"; Switch "LOOP". Control section: Potentiometer "SPEED": allowing to set the desired speed through an analog signal 0 to 10V. Potentiometer "ta": allowing to set the acceleration time from 5 to 15 s approx. Potentiometer "td": allowing to set the deceleration time from 5 to 15 s approx. Display and keyboard: allowing the inverter programming. Instrumentation and test points section: Tachometer "min-1": ranges 0 to 4000/8000 min-1, operating only with tachometric transducer connected to relevant connector. Motor voltage: voltage waveforms, galvanically insulated and proportional to line-toline inverter output voltage, available between test points Ui2 /U23/U31 and ground. Motor current: line current waveform available between relevant test point and ground. Trigger signals: drive waveforms applied to three-phase inverter available between test points and ground: • R1 /R2: leg R • Y1 /Y2: leg Y • B1 /B2: leg B Power section: Input supply: mains 3x380/460 V ± 10%, 45-65 Hz. Max motor power: 3.7 kW/5 hp. Rated output current: 9.5 A. Max output current: 14.3 A for 60 s. Output voltage: 0 to 3x380/460 V (scale factor 0.00 to 115.47%). Output frequency: 0 to 480 Hz. Dc braking. It must be possible to perform the following experiment : Reset and factory default settings - Operation of the inverter in setpoint mode -Speed regulation in remote mode - Multispeed operation - Speed regulation in local mode- Ixt overload -Motor power curve - Motor torque-speed curve - Variable frequency speed control - Closed loop speed regulation The unit must be supplied with a theoretical and practical manual in English language.