* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download medium-voltage measuring current transformers user
Voltage optimisation wikipedia , lookup
Buck converter wikipedia , lookup
Current source wikipedia , lookup
Ground (electricity) wikipedia , lookup
Stepper motor wikipedia , lookup
Stray voltage wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power engineering wikipedia , lookup
Single-wire earth return wikipedia , lookup
Mains electricity wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Three-phase electric power wikipedia , lookup
Earthing system wikipedia , lookup
Rectiverter wikipedia , lookup
Electrical substation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Opto-isolator wikipedia , lookup
Alternating current wikipedia , lookup
MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS USER MANUAL F.T.M. S. r. l. Fabbrica trasformatori di misura Via Po, 3 20090 Opera – MI - Italy Tel : +39 (0)2 576814 Fax : +39 (0)2 57605296 E-mail: [email protected] Website: www.ftmsrl.it SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 1 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL CONTENTS 1 INTRODUCTION 2 CHOICE OF DEVICES 2.1 SYSTEM SPECIFICATIONS 2.2 ENVIRONMENTAL CONDITIONS 2.3 SAFETY DISTANCES 3 TRASPORT 4 STORAGE 5 INSTALLATION 5.1 MECHANICAL ASSEMBLY 5.2 CONDENSATION PHENOMENA 5.3 CONNECTIONS TO THE MAIN CIRCUITS 5.4 GROUND CONNECTIONS 5.5 SEALING THE SECONDARY TERMINALS 6 COMMISSIONING 7 MAINTENANCE 8 STAFF TRAINING 9 TECHNICAL SPECIFICATIONS SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 2 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL 1. INTRODUCTION This manual provides all the information needed to safely operate measuring current transformers (CTs) suitable for installation and use in medium voltage systems (from 7.2 kV to 36 kV), and IEC 60044-1 compliant. 2. CHOICE OF DEVICES Devices must be chosen so as to meet all the electrical parameters of the system in which they will be installed, paying particular attention to the following: 2.1 SYSTEM SPECIFICATIONS • Power grid’s operating voltage SERIES AOC/ETO MTA 7 MTA15/CTF17 MTA 24/CTA 24/CTP24/CTF24/STA/ETA/RTA24/DTA 24 RTA36 • • • • • • Operating voltage From 0.72 kV to 24 kV Up to 7.2 kV From 7.2 kV to 17.5 kV From 7.2 kV to 24 kV From 7.2 kV to 36 kV Rated primary current ¾ Limits as reported on the product’s technical datasheet Rated secondary current ¾ All transformer series: 5A or 1A ¾ Special modifications on request Short circuit thermal current and time ¾ All transformer series are guaranteed to bear 100 times the rated primary current for 1 second. ¾ Special modifications on request Short circuit dynamic current ¾ All transformer series guarantee 2.5 times the short circuit thermal current. ¾ Special modifications on request Frequency ¾ 50 – 60 Hz Type of use ¾ Measure or protection ¾ All transformer series comply with the product’s standards. SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 3 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL 2.2 ENVIRONMENTAL CONDITIONS Transformers may be subjected to the following environmental conditions, which need to be carefully taken into account: • Temperature ¾ All transformer series: from -5 °C to +40 °C ¾ Insulation class E ¾ Special modifications on request • Altitude ¾ All transformer series: up to 1000 m a.s.l. ¾ Special modifications on request • Humidity ¾ All transformer series: o The mean relative humidity, measured over 24h, must not exceed 95%. o The mean steam pressure, measured over 24h, must not exceed 2.2 kPa. o The mean relative humidity per month must not exceed 90%. o The mean steam pressure per month must not exceed 1.8 kPa. ¾ Special modifications on request • Installation ¾ All transformer series: indoor installation • Pollution levels ¾ All transformer series: installation is possible even in tropical climates • Corrosive agents ¾ To be reported if present • Dust and deposits ¾ To be reported if present 2.3 SAFETY DISTANCES Safety distances to be complied with in CT installation are as provided by the standards on medium tension insulated power systems. 3. TRASPORT Transformers will be suitably packaged for transport according to the type of product and transport, or to the modality agreed on with the customer. On reception of the device, users are kindly asked to inspect it carefully to ensure the product is undamaged. 4. STORAGE Devices must be stored in clean and dry areas, between -20°C and +70°C (except as otherwise specified). Packaged units may be stacked one on top of another if allowed by and in conformity with the packaging’s technical specifications. SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 4 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL 5. INSTALLATION All installation operations must be carried out in compliance with all existing accident prevention measures and the following instructions: 5.1 MECHANICAL ASSEMBLY Before tightening, please ensure that the surfaces connecting the conductors and the transformer’s primary and secondary terminals are clean and in good conditions. Also ensure that the connections do not cause abnormal mechanical stress to the devices’ terminals. The maximum and minimum tightening torques of the screw threads to be used for connection to the primary and secondary terminals are as follows: Terminals Screw thread Primary Secondary M12 M10 M6 Maximum torque Nm 35 25 5 Minimum torque Nm 15 10 3 Finally, check that no electrical insulation distance was altered during the connecting operation. 5.2 CONDENSATION PHENOMENA In order for the transformer to withstand the effects of high humidity and condensation, it is advisable to ventilate and heat the installation switchboard, or to apply dehumidifying devices to it. 5.3 CONNECTIONS TO THE MAIN CIRCUITS The primary and secondary connections must be checked to ensure they are compatible with the wiring diagram and the symbols present on the transformers. The graphics printed on the transformers, showing how to connect them correctly, is as follows: SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 5 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL Single primary ratio CT with a secondary winding Single primary ratio CT with two secondary windings Primary Primary Secondary Secondary Double primary ratio CT with the ratio change occurring on the secondary winding and with a secondary winding Double primary ratio CT with the ratio change occurring on the primary winding and with a secondary winding Primary Primary Secondary The correct connections to obtain the different primary burdens are as follows: example: CT 100-200/5 A-A/A Lowest primary ratio: 100/5 A/A,connect to the secondary terminals: S1 and S2 Highest primary ratio: 200/5 A/A connect to the secondary terminals: S1 and S3 Secondary The correct connection to obtain the different primary burdens, to be made using the copper plates provided, is as follows: example: CT 100-200/5 A-A/A Lowest primary ratio: 100/5 A/A,connect the primary terminals: C1 and C2 Highest primary ratio: 200/5 A/A connect the primary terminals: P1 / C1 and the primary terminals: P2 / C2 Please pay maximum attention to the conditions of the CTs’ secondary circuits, which must be connected to the burden or shorted at all times. SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 6 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL 5.4 GROUND CONNECTIONS The support plates and one terminal per secondary winding must be connected to the ground. 5.5 SEALING THE SECONDARY TERMINALS All transformers are provided with a thermoplastic cap and fixing screws to protect and seal the secondary clamps. 6. COMMISSIONING To guarantee staff and device safety, please make sure, by checking the specifications on the label, that the system’s electrical parameters do not exceed the transformer’s nominal parameters. The data reported on the identification label are as follows: 1 Series / Type 2 Code This is an 8-figure code, in which the first two figures represent the manufacturing year. 3 Insulation reference voltage / Power frequency withstand voltage / Impulse withstand voltage, expressed in kV 0.72/3/- 1.2/6/- 7.2/20/60 - 12/28/75 – 17.5/38/95 – 24/50/125 – 36/70/170 (IEC standard-compliant values) 4 Short circuit thermal current and time Expressed in kA and seconds 5 Short circuit dynamic current Expressed in peak kA 6 Frequency Expressed in Hz 7 Product’s reference standards. 8 Rated transformation ratio. Rated primary current, A / Rated secondary current, A 9 Burden applied to the secondary terminals to which the accuracy class refers. Expressed in VA 10 Accuracy class 11 Safety factor (if required) 12 Continuous thermal withstand value Percentage referring to rated currents 13 Secondary terminals’ symbols SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 7 of 8 MEDIUM-VOLTAGE MEASURING CURRENT TRANSFORMERS – USER MANUAL 7. MAINTENANCE Before carrying out any operation, make sure that the CTs are not connected to the power grid or powered in any way. Check the tightening of the primary and secondary connections. Ensure that the insulating resin surface shows no signs of deterioration such as carbonisation or cracks. Periodically remove any dust or other deposits that may accumulate on the transformers’ surfaces. Avoid using solvents. 8. STAFF TRAINING All installation, commissioning and maintenance operations must be carried out by trained staff. Staff need to be trained in order for them to operate competently within the field. 9 TECHNICAL SPECIFICATIONS For further information on the field of application and technical definitions, please refer to the product’s standard: IEC 60044-1 The products’ technical datasheets are available online at: www.ftmsrl.it In accordance with the existing law, F.T.M. S.r.l. expressly prohibits any reproduction, retransmission, republication, or other use of all or part of this document without prior authorisation. SM SL Drafted MOD.PRG M042 -31.05.2007 Checked/Issues A Rev M.O. No. 10/10/2010 Date Issued Description 8 of 8