* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 5 Model Input power requirements Output Voltage / Current ranges
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Power inverter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Three-phase electric power wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Scattering parameters wikipedia , lookup
Mechanical-electrical analogies wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power electronics wikipedia , lookup
Voltage optimisation wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power MOSFET wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Current source wikipedia , lookup
Opto-isolator wikipedia , lookup
Buck converter wikipedia , lookup
Zobel network wikipedia , lookup
Nominal impedance wikipedia , lookup
Model Input power requirements PT-600-480-2-60 480 V, 2 conductor + ground, 150 A input current maximum for 5 seconds (100 A service / fusing OK) Output Voltage / Current ranges Sensing points BLUE AREA: Output Voltage and Current 0-600V, 10 Ohm source impedance, up to 60A; 2 channels, 5 sec. max. 0-600V, 15 Ohm source impedance, up to 40A; 2 channels, 5 sec. max. 0-600V, 20 Ohm source impedance, up to 30A; 2 channels, 5 sec. max. 0-600V, 85.7 Ohm source impedance, up to 7A; 2 channels, 5 sec. max. 0-600V, 120 Ohm source impedance, up to 5A; 2 channels, continuous duty 0-300V, 15 Ohm source impedance, up to 20A; 2 channels, continuous duty 0-277V, 11.1 Ohm source impedance, up to 25A; 2 channels, continuous duty 0-230V, 10 Ohm source impedance, up to 23A; 2 channels, continuous duty 0-230V, 20 Ohm source impedance, up to 11.5A; 2 channels, continuous duty 0-230V, 40 Ohm source impedance, up to 5.8A; 2 channels, continuous duty 0-230V, 80 Ohm source impedance, up to 2.9A; 2 channels, continuous duty 0-120V, 8.4 Ohm source impedance, up to 25A; 2 channels, continuous duty 0-600V, 90-272 Ohm source impedance continuously variable, up to 2.2A continuous or 3A for one sec., 2 channels, continuous duty 0-600V, 272-440 Ohm source impedance continuously variable, up to 600V, 2 channels, continuous duty 0-600V, 440-2390 Ohms source impedance continuously variable, up to 600V, 2 channels, continuous duty 0-600V, 2350-13.6Kohm source impedance, continuously variable, up to 600V, 2 channels, continuous duty 0-600V, 2 Ohm source impedance, up to 300A; 2 channels, 0.5 sec. max. (must be used in conjunction with Line Simulator Fuse adjacent) Sensing Points: Voltage Sense: Measured between Voltage Sense and Return, reads actual voltage. Check DMM range; reading voltages up to 5 600V. Two channels. Current Sense: Measured between Current Sense Receptacles, reads 0.2V/A. Two channels. YELLOW AREA: (First Level AC Power Fault) Output Voltage and Current 0-1000V, 1Kohm source impedance, up to 1A; 4 channels, continuous duty 0-1000V, 200 ohm source impedance, up to 5A; 4 channels, 0.5 sec. max. (ITU-T Power Induction Test) 0-1500V, 200 ohm source impedance, up to 7.5A; 2 channels, 1 sec. max. Outputs are switch selectable and may be disabled. Sensing Points: Voltage Sense: Measured between Voltage Sense and Return, reads actual voltage. Not energized until TEST button is pressed. Reads voltages up to 1000V. Channels C, D, E and F. Note: Voltage sense terminals are inoperative for the ITU-T Power Induction Test circuit. Voltage readings must be made at the test output jacks. Current Sense: Measured between Current Sense Receptacles, reads 0.2V/A. Four channels for First Level AC Power Fault; two channels for ITU-T Power Induction Test. VIOLET AREA: (High Impedance Inductive Source Test) Output voltage and current 0-600V, In accordance with GR-1089, Third Edition, Table 4-7 Test 5 and Table 4-8 Test 5; Circuit as shown in GR-1089, Third Edition, Figure 4-4. Supplied with outputs VT and VR. Sensing Points; Sense points V and V’; in accordance with GR-1089, Third Edition, Figure 4-4. Mechanical: Weight: 800 lbs Dimensions: 31”W x 27"D x 82”H Environmental: 15-40°C operating temperature / 0-90% Relative Humidity, non-condensing Table 1. PT-600 series specifications 6