* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 63-1337-01 - Class 200 Meters Three-Phase Meters
Survey
Document related concepts
Peak programme meter wikipedia , lookup
Sound level meter wikipedia , lookup
History of electric power transmission wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power engineering wikipedia , lookup
Stray voltage wikipedia , lookup
Current source wikipedia , lookup
Voltage optimisation wikipedia , lookup
Smart meter wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Three-phase electric power wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Power electronics wikipedia , lookup
Buck converter wikipedia , lookup
Mains electricity wikipedia , lookup
Current mirror wikipedia , lookup
Transcript
Class 200 Meters Three-Phase Meters SPECIFICATION DATA FEATURES • 0-2 volt output split-core current sensors allow for quick and safe installation without power interruption. • Retain meter reading in the event of power failure. • Meters can be placed up to 2,000 feet away from an electric panel. • Current sensor installation diagnostic indicator. • UL/CUL Listed with utility-grade accuracy. • Parallel up to three (3) sets of current sensors for cumulative reading. • Meter can be used on the following configurations: 3-Phase, 4-Wire 3-Phase, 3-Wire 2-Phase, 3-Wire • Optional removable terminal block for pulse output. • Industrial-grade JIC steel enclosure with padlocking hasp and mounting flanges for indoor installations with 1-1/16 in. KO (3/4 in. Cond.) on bottom of enclosure. • Non-volatile Memory. SPECIFICATIONS OVERVIEW The Honeywell Class 200 kWh meters are fully electronic,lowcost meters for monitoring electrical usage in multifamily,commercial and industrial applications. APPLICATIONS Metering specific tenants, departments, cost centers or pieces of equipment in your facility allows you to pinpoint when and where energy is being used—right down to the specific date and time. Armed with this data, you can take steps to curtail this usage and thus reduce your overall energy consumption costs. • Ideal for indoor and outdoor use. • Monitors a single electrical circuit, piece of equipment, department, tenant, or even the entire building. • Easy and affordable installation virtually anywhere, including both new and retrofitted facilities. Dimensions: 7-1/4 in. H x 7 in. W x 3-1/4 in. D Accuracy: Certified to ANSI C12.1 & C12.16 Voltage Input Configuration: 4 wire 120/208-240 volt 3 wire 240 volt 4 wire 277/480 volt 3 wire 480 volt Current Input: Up to 3200 Amp RMS AC Power Factor: .5 leading and lagging Frequency: 50-60 HZ Temperature Range: Operating Temp: -20°C to 50°C. Relative Humidity Range: 0-95% Non-Condensing Voltage Overload: +25% Continuously; +100% for 20 cycles Pulse Output Type: Optically coupled, normally open electronic switch. Output: Solid-state switch, N.O. equivalent. ® 63-1337-01 CLASS 200 METERS THREE-PHASE METERS Typical ON Resistance: 30 Ohms Maximum OFF Leakage: 1 uA Pulse Closure Time Cycle: 50% External Interface Voltage: 1.5 to 36 volts DC or AC Maximum Interface Current: 100 ma Current Sensor Overload: 100% for 1 minute without damaging meter Approvals: UL Listed and CSA Approved 3-3/4 (95) 1-19/64 (33) 1-1/2 (38) 1-3/8 (35) 4-1/4 (108) 29/32 (23) 1-3/16 (30) M29269 Fig. 3. 400 Amp current sensor dimensions in in. (mm). 1-1/4 (32) 6-3/32 (155) 7 (178) 3-1/4 (83) 2-3/8 (60) 4-19/64 (109) 7-1/2 (191) 5-3/4 (146) M29258 Fig. 1. Class 200 meter enclosure dimensions in in. (mm). M29270 Fig. 4. 800 and 1600 Amp current sensor dimensions in in. (mm). 3-3/4 (95) 29/32 (23) 1-19/64 (33) 1-1/4 (32) 7-3/4 (197) 1-3/8 (35) 2-3/4 (70) M29268 Fig. 2. 100 and 200 Amp current sensor dimensions in in. (mm). 9-3/32 (231) 5-3/8 (137) 7-7/8 (200) M29271 Fig. 5. 3200 Amp current sensor dimensions in in. (mm). 63-1337—01 2 CLASS 200 METERS THREE-PHASE METERS ORDERING INFORMATION Table 1. Model Numbers. Model # Amps SUB208-100 100 SUB208-200 200 SUB208-400 400 SUB208-800 800 SUB208-1600 1600 SUB208-3200 3200 SUB480-100 100 SUB480-200 200 SUB480-400 400 SUB480-800 800 SUB480-1600 1600 SUB480-3200 3200 Description 120/208-240V, 3-Phase, 4W 240V, 3-Phase, 3W (Supplied with one set of three (3) split-core current sensors) 277/480V, 3-Phase, 4W 480V, 3-Phase, 3W (Supplied with one set of three (3) split-core current sensors) 3 63-1337—01 CLASS 200 METERS THREE-PHASE METERS Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Registered Trademark © 2009 Honeywell International Inc. 63-1337—01 M.S. 04-09