Download High/Low Voltage Disconnect Test Procedure

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electric battery wikipedia , lookup

Ground (electricity) wikipedia , lookup

Spark-gap transmitter wikipedia , lookup

Audio power wikipedia , lookup

Decibel wikipedia , lookup

Stepper motor wikipedia , lookup

Portable appliance testing wikipedia , lookup

Power engineering wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Electrical ballast wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Ohm's law wikipedia , lookup

Three-phase electric power wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Current source wikipedia , lookup

Power inverter wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Electrical substation wikipedia , lookup

Islanding wikipedia , lookup

History of electric power transmission wikipedia , lookup

Distribution management system wikipedia , lookup

Triode wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Power MOSFET wikipedia , lookup

Rectifier wikipedia , lookup

Metadyne wikipedia , lookup

Schmitt trigger wikipedia , lookup

Power electronics wikipedia , lookup

Surge protector wikipedia , lookup

Opto-isolator wikipedia , lookup

Stray voltage wikipedia , lookup

Voltage regulator wikipedia , lookup

Alternating current wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
P12441: Thermoelectric Stove for Haiti 1
High/Low Voltage Disconnect Test Procedure
1. Test Name: High/Low Voltage Disconnect
Test Author: Andrew and Xiaolong
The high voltage disconnect is integrated to protect the battery from overcharging and low
voltage disconnect is integrated to disconnect the USB and fan so the battery will have enough
power to restart the system for one hour.
2. Required Equipment
Equipment Description
Quantity
1
Power Supply
2
2
3
Oscilloscope
HV/LV disconnect system
1
1
Settings
PS1: 12V
PS2: Variable
Trigger on the rising/falling edge
Table 1: Required equipment and its settings.
3. Test Procedure
Step 1: Build the HV/LV disconnects system as seen in the system schematic.
Step 2: Connect the power supply to the +12V rails of the circuit.
Step 3: Connect the output of power supply two to the battery terminal pins of the circuit.
Step 4: Adjust the output of power supply two to 6.2V, slowly increase it by hundredths of a volt
until the battery is disconnected from the circuit. Record the voltage.
Step 5: Adjust the output of power supply two to 5.8V, slowly decrease it by hundredths of a
volt until the USB output and fan output are disconnected. Record the voltage.
4. Test Results
Step #
1
2
Description
High Voltage Disconnect
Voltage
Low Voltage Disconnect
Voltage
Spec
Measurement
Voltage: 6.2V +/- 5%
6.24V
Voltage: 5.8V +/- 5%
5.8V
Table 2: The results of the test procedure.
P12441: Thermoelectric Stove for Haiti 2
High/Low Voltage Disconnect Test Procedure
Figure 1: Output voltage drops when the battery terminal voltage reaches 6.24V
Figure 2: Output Voltage drops when the battery terminal voltage goes below 5.8V
5. Pass/Fail
Did the unit pass or fail the test? Defend your decision.
PASS FAIL
Pass
Table 3: PASS/FAIL