* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download FP5000 Feeder Protection
Resistive opto-isolator wikipedia , lookup
Pulse-width modulation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Buck converter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stray voltage wikipedia , lookup
Curry–Howard correspondence wikipedia , lookup
Surge protector wikipedia , lookup
Opto-isolator wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Power electronics wikipedia , lookup
Fault tolerance wikipedia , lookup
Electrical substation wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Three-phase electric power wikipedia , lookup
Earthing system wikipedia , lookup
Protective relay wikipedia , lookup
FP5000 Refer to www.eatonelectrical.com for the latest information on this constantly evolving product FP5000 Product Overview • Microprocessor design combines protection, metering and control into a single compact package • Flexible configuration and programmable logic control for custom applications • Easy navigation keys and menu structure make it simple and safe to use • Meets ANSI, UL and CUL standards FP5000 Product Overview • User Interface – Latching cover and Password protection for security – 4 x 20 character vacuum fluorescent display for improved readability – 18 status LED’s for trip, alarm, breaker status and display mode indication • Battery backed up trip LED for target indication even if station is dead – Direct access to monitoring, view settings, logs and status/control screens – Breaker open/close buttons can provide direct breaker control when enabled FP5000 Product Overview • Hardware – Advanced 32 bit Microprocessor design – Compact drawout case design for easy installation and removal – Four currents inputs (1A or 5A) • Measured three phase and ground currents • Calculated residual ground current – Four voltage inputs • Three phase plus fourth auxiliary voltage measurement FP5000 Product Overview • Hardware – 8 optically isolated contact inputs – 5 trip rated “a” contact outputs • 2 outputs with circuit continuity monitoring – 2 form c alarm contacts • One is for relay healthy alarm – C-H Zone Interlocking Circuitry – Inputs and outputs are user configurable FP5000 Protection Features One-line Drawing FP5000 Protection Features • Three phase and ground overcurrent (50P-1, 50P-2, 50P-3, 51P and 50R-1, 50R-2,50R-3,51R, 50X-1,50X-2,50X-3,51X) – Measured (X) and calculated (R) ground currents • Negative sequence overcurrent (46-1, 46-2) • Three phase over and under voltage protection (27M-1, 59M-1, 27M-2, 59M-2) • Single phase over and under voltage protection (27A-1, 27A-2, 59A-1, 59A-2) • Over and under frequency protection (81U-1, 81U-2, 81O-1, 81O-2) FP5000 Protection Features • Negative sequence over voltage protection (47-1,47-2) • Breaker failure (50BF) – Internal Breaker Failure Initiation – External Breaker failure Initiation • Apparent and Displacement Power factor (55A,55D) • Four setting groups available FP5000 Protection Features • Zone Interlocking – Faster fault clearing times with better zone coordination – Stuck breaker (breaker failure) accelerated remote fault clearing – Phase and ground selectable – Extended range up to 1000’ – Works with DT3000 FP5000 Protection Features •Zone Interlocking •Fault @ Location 2 •Relay @ CB2 sees fault & sends interlocking signal to upstream devices at CB1 •Upstream devices continues to operate on normal set time for remote backup protection •CB2 fast trips to interrupt fault •If CB2 fails to interrupt fault in 10 cycles remote clearing of CB1 occurs •Fault @ Location 1 •Relay @ CB2 does not see the fault no signal is sent to relay @ CB1 •Relay @ CB1 sees fault but does not receive interlocking signal - Fast Trips CB1 Zone 1 Fault 1 CB2 Zone 2 Fault 2 FP-5000 Metering Features • RMS Load Values – – – – – – Currents - Ia, Ib, Ic, IX, IR, I Average Voltages - LL, LN, VX, LL Average, LN Average System Power - Watts, vars, VA Power Factor, Frequency % THD Voltage and Current Magnitude THD Voltage and Currents • Current accuracy ±0.5% or ±0.025 A • Voltage accuracy ±0.5% or ±0.02 V • Power accuracy ±1.5% worse case FP5000 Metering Features • Fundamental phasor measurements – Magnitude and phase angle of voltages and currents – Magnitude and phase angle of positive, negative and zero sequence voltages and currents – Percent voltage unbalance and phase rotation (%V2/V1) – Percent current unbalance and phase rotation (%I2/I1) FP-5000 Metering Features • Energy Measurements – – – – System Watt Hours - Forward, Reverse, Net System var Hours - Forward, Reverse, Net System VA Hours Start Date & Time for Energy Accumulation • Minimum & maximum values – – – – – – Phase and Ground Currents Voltages - LL and LN System Power Frequency Power Factor time and date stamp FP-5000 Monitoring Features • Relay self-diagnostics and Relay Healthy Alarm Output (failsafe operation) – Memory and setting checks – Calibration and A/D monitoring – Power supply monitoring – Watchdog timer • Trip circuit monitoring and alarming • Close circuit monitoring and alarming FP-5000 Monitoring Features • Circuit breaker monitoring and Alarming – Breaker open/close state and indication – Operation counter and alarm – Breaker wear alarm (accumulated interrupted current per phase) – 52 auxiliary contact monitoring with 52a and 52b contact inputs connected – Sluggish breaker operation monitoring – Loss of Vacuum monitoring – Stuck breaker (breaker failure) Breaker Monitoring Logic FP-5000 Logic & Control Features • Breaker open and close logic with front panel open/close control • Power factor monitoring and cap bank switching control • Output contact logic gate control • Overcurrent blocking gates • Multiple setting group selection and control • Main-tie-main transfer schemes FP-5000 Logic & Control Features • Programmable logic control function – Six programmable logic gates • AND OR, NAND, NOR • 4 programmable inputs – Six programmable timers • Pick up time delay • Drop out time delay – Two Latching logic gates – Use internal or external signals LOGIC_LGxState, LOGIC_TGxState Logic Data Store: LOGIC_BlkState LOGIC_LGxState, LOGIC_TGxState LOGIC IN1 IN2 IN3 IN4 LOGIC PROT Data Store: Pickup Flags Trip Flags PROT Block 50z# (9) IN1 IN2 IN3 IN4 Block 51z (3) Recl Logic Gate (6) IN1 IN2 IN3 IN4 Direction Logic Data Store: LOGIC_LGxState LOGIC_TGxState LOGIC_OGxState LG1 - LG6 CNTRL Data Store: RecloseFlags Sync Flags DirectionFlags Timer Gate (6) IN RECL LOGIC_OGxState TG1 - TG6 On Delay DIR Off Delay Cin1 Cin2 Cin3 Cin4 Cin5 Cin6 Cin7 Cin8 Zin CIN Input Data Store: CinState - Cin1-8, Zin CinBkr - 52a, 52b, BFI RemOpen, RemClose Reset Set Latch (2) Reset Q1 - Q2 Relay Test COUT Disarm Comm Open/Close Bkr Open/Close Bkr PB BKR TRIP1, TRIP2 Monitor In MNTR COMM Breaker Data Store: Bkr State Bkr Operations Bkr Accum I System Alarm Flags Comm Logic Flags COUT Data Store: Relay States Comm Trip / Alarm Indicators LED States IN1 IN2 IN3 IN4 Output Gate (7) OG1 - OG7 TRIP1 TRIP2 K3 K4 K5 ALM1 ALM2 Zout FP-5000 Data Logging Features • Event log records 100 events with date and time stamp ( 1 ms resolution) – Event Types • General – – – – Control power on/off Breaker open/close Reset demand, min/max, energy Change settings • Trip, alarm, pickup, dropout • Input / output state change • Self-test warning FP-5000 Data Logging Features • Trip log records last 16 trips – Date & time stamp (1 ms resolution) – Fault type, status – Trip counter, event number, osc buffer – Time to trip (51 elements) – Phase currents & voltages (rms. and phasor) – Frequency – I/O and logic states FP-5000 Data Logging Features • History log records accumulated values – Number of operating hours – Number of trips – Number of breaker operations – Accumulated interrupted amps per phase – Times powered up – Number of setting changes – Date and time stamp of last reset FP-5000 Data Logging Features • Data logger – 1024 records in 128 blocks – Each block: timestamp & 8 records – Log 8 quantities in each record • Default configuration logs currents & voltages • Select from V, I, Power, PF, Freq, %THD, Demand, Contact inputs/outputs – Select logging interval from 1 s to 1 hour – Select continuous or single pass logging – Trigger: auto, Cin, Logic, PB, Comm. FP-5000 Data Logging Features • Waveform Capture – 256 cycles of data storage – Select Trigger: Pickup, Trip, Cin, dV/dI, Logic, PB, Comm. – Number of pre-trigger cycles is configurable – Stored Parameters – 32 samples per cycle: 4 Currents, 4 Voltages – Once a cycle: • • • • rms and phasor Voltages & Currents Frequency, Fault Type Input & Output States Pickup, Trip, Alarm, & Logic States FP-5000 Change Setpoints • Protection Setting Group 1 Overview FP-5000 Change Setpoints • Phase Overcurren t Settings – 51P ITOC – 50P-1 IOC – 50P-2 IOC FP-5000 Change Setpoints • Current & Voltage Unbalance • Under & Over Voltage Protection FP-5000 Change Setpoints • Breaker Failure • Power Factor • Over & Under Frequency Protection FP-5000 Change Setpoints • Trip 1 Output Relay Settings FP-5000 Change Setpoints • Indicator Settings FP-5000 Monitoring • Metering Overview FP-5000 Control • Relay Control • Reset Functions • Active Setting Group Control