Download The following changes affect the APP60S Service Power Supply

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Flip-flop (electronics) wikipedia , lookup

Electrical ballast wikipedia , lookup

Power factor wikipedia , lookup

Switch wikipedia , lookup

Current source wikipedia , lookup

Power over Ethernet wikipedia , lookup

Electrification wikipedia , lookup

Electric power system wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Three-phase electric power wikipedia , lookup

Islanding wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Audio power wikipedia , lookup

Stray voltage wikipedia , lookup

Pulse-width modulation wikipedia , lookup

History of electric power transmission wikipedia , lookup

Integrating ADC wikipedia , lookup

Electrical substation wikipedia , lookup

Power engineering wikipedia , lookup

Power inverter wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Distribution management system wikipedia , lookup

Rectifier wikipedia , lookup

Voltage regulator wikipedia , lookup

Schmitt trigger wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Power supply wikipedia , lookup

Opto-isolator wikipedia , lookup

Mains electricity wikipedia , lookup

Buck converter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
Operator’s Manual Addendum
for APP9015S
The following changes affect the APP60S Service Power Supply Operator’s Manual when using a
APP9015S:
1.3
Specifications
Model
Input Voltage
Input Frequency
Input Current Max.
APP 9015S
120 V / 240 V AC 15%
60Hz
16 Amps
Output Voltage
Output Current
Output Power
60 V / 75 V / 90 V AC 5%
15 Amps
900VA @ 60, 1125VA @ 75, 1350VA @ 90
Output Current Limit
133% Rated Output Current
Efficiency
90% Typical @ rated load
Operating Temp Range
-40F to +122F (-40C to +50C)
Dimensions
9.5” W x 9” H x 13.75” L
Weight
48 lbs
Finish
FLAT BLACK
2.
Front Panel
2.2.A AC Output Breaker
This breaker protects the load from excessive output currents. Reset breaker if tripped.
2.3.A AC Input Breaker
This breaker is used to turn the Power Supply on and off. In the event the power supply Input Voltage
Select switch is set incorrectly this breaker will trip. Do not attempt to reset until the correct input voltage
has been selected.
2.5.A 60/75/60 VAC Rotary Switch
The 60/75/90 VAC switch is used to select output voltage. Be sure to have correct output voltage settings
selected before operation of power supply. Do not rotate switch when unit is in operation, always remove
power from power supply when selecting output voltages.
2.6.A ON / OFF Switch
The input breaker is used as the power ON / OFF switch in the APP 9015S.
2.8.A AC Line Cords
Select either the 5-20P, or the 6-15P line cord depending upon the application. Always select correct input
line voltage before turning on power to the power supply.