* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download The following changes affect the APP60S Service Power Supply
Flip-flop (electronics) wikipedia , lookup
Electrical ballast wikipedia , lookup
Power factor wikipedia , lookup
Current source wikipedia , lookup
Power over Ethernet wikipedia , lookup
Electrification wikipedia , lookup
Electric power system wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Three-phase electric power wikipedia , lookup
Solar micro-inverter wikipedia , lookup
Audio power wikipedia , lookup
Stray voltage wikipedia , lookup
Pulse-width modulation wikipedia , lookup
History of electric power transmission wikipedia , lookup
Integrating ADC wikipedia , lookup
Electrical substation wikipedia , lookup
Power engineering wikipedia , lookup
Power inverter wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Distribution management system wikipedia , lookup
Voltage regulator wikipedia , lookup
Schmitt trigger wikipedia , lookup
Alternating current wikipedia , lookup
Voltage optimisation wikipedia , lookup
Power supply wikipedia , lookup
Opto-isolator wikipedia , lookup
Mains electricity wikipedia , lookup
Operator’s Manual Addendum for APP9015S The following changes affect the APP60S Service Power Supply Operator’s Manual when using a APP9015S: 1.3 Specifications Model Input Voltage Input Frequency Input Current Max. APP 9015S 120 V / 240 V AC 15% 60Hz 16 Amps Output Voltage Output Current Output Power 60 V / 75 V / 90 V AC 5% 15 Amps 900VA @ 60, 1125VA @ 75, 1350VA @ 90 Output Current Limit 133% Rated Output Current Efficiency 90% Typical @ rated load Operating Temp Range -40F to +122F (-40C to +50C) Dimensions 9.5” W x 9” H x 13.75” L Weight 48 lbs Finish FLAT BLACK 2. Front Panel 2.2.A AC Output Breaker This breaker protects the load from excessive output currents. Reset breaker if tripped. 2.3.A AC Input Breaker This breaker is used to turn the Power Supply on and off. In the event the power supply Input Voltage Select switch is set incorrectly this breaker will trip. Do not attempt to reset until the correct input voltage has been selected. 2.5.A 60/75/60 VAC Rotary Switch The 60/75/90 VAC switch is used to select output voltage. Be sure to have correct output voltage settings selected before operation of power supply. Do not rotate switch when unit is in operation, always remove power from power supply when selecting output voltages. 2.6.A ON / OFF Switch The input breaker is used as the power ON / OFF switch in the APP 9015S. 2.8.A AC Line Cords Select either the 5-20P, or the 6-15P line cord depending upon the application. Always select correct input line voltage before turning on power to the power supply. 016529B0001A__W__.doc Operator’s Manual Addendum for APP9015S 016529B0001A__W__.doc