Download optotronic ® ot 120/220-240/12 p

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Electric power system wikipedia , lookup

Electrification wikipedia , lookup

Audio power wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electrical substation wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Islanding wikipedia , lookup

Power inverter wikipedia , lookup

Current source wikipedia , lookup

Power over Ethernet wikipedia , lookup

Stray voltage wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

History of electric power transmission wikipedia , lookup

Three-phase electric power wikipedia , lookup

Power MOSFET wikipedia , lookup

Surge protector wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Rectifier wikipedia , lookup

Power engineering wikipedia , lookup

Voltage regulator wikipedia , lookup

Earthing system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Alternating current wikipedia , lookup

Power electronics wikipedia , lookup

Opto-isolator wikipedia , lookup

Solar micro-inverter wikipedia , lookup

Buck converter wikipedia , lookup

Power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

AC adapter wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Transcript
OPTOTRONIC®
OT 120/220-240/12 P
Constant Voltage LED Power supply for 12V LED - Modules
1. Technical Data
Nominal Voltage
Input Voltage
Line Current, nominal
Mains Frequency
Power Factor
Interface
IP Rating
Max Output Power
220 – 240 Vac
198 – 264 Vac
0,65A@230Vac
50 / 60 Hz
= 0,98 @ 230 Vac
None
IP 67
120 Watt
Output Voltage
Efficiency
Ambient Temperature
Max. Case Temperature at tc
Max. Cable Length
Max load per circuit breaker B10
Max load per circuit breaker B16
Max load per circuit breaker C10
12,5 Vdc (-0,5 V/+0,5 V)
88 % @230Vac
-25°C to +55°C
+ 80°C
10m
6
10
9
2. Connection schemes
(+) 12V
(-) GND
red
black
LED Module
(+) 12V
a)
b)
c)
(-) GND
OT 120/220-240/12 P
3
red
black
LED Module
Ensure proper insulation of not connected wire terminals.
2 Output channels for optional splitting of the load (1 channel use also possible when the not used cable is open)
Ensure that the complete Load is not connected to one channel. Maximum output current is limited by the cross section of the cable
(7.5A per channel – 90 Watt) a). It is possible to join the two output cables together, in parallel, to drive one module at max power.
3. Safety
+
+
3
OT 120/220-240/12 P
LED Module
120 Watt
3
OT 120/220-240/12 P
220 – 240V AC
+
3
OT 120/220-240/12 P
LED Module
240 Watt
+
-
LED Module
120 Watt
3
OT 120/220-240/12 P
Power supplies can be connected in parallel on the primary side, but not on the secondary side
L
N
PE
L
N
PE
~
~
~
~
~
~
+
OT 120/220-240/12 P
~
~
LED Module
+
OT 120/220-240/12 P
~
~
LED Module
+
OT 120/220-240/12 P
~
~
LED Module
+
OT 120/220-240/12 P
LED Module
+
OT 120/220-240/12 P
LED Module
+
OT 120/220-240/12 P
LED Module
The installation of two ore more OPTOTRONIC® OT 120/220-240/12 P Power supplies with common “-“ or “+” wiring is forbidden.
OSRAM AG
www.osram.com
2013-03-13
AA390790055
Steinerne Furt 62, 86167 Augsburg, Germany
No. 1, North Industrial Road
528000 Foshan Guangdong, P.R. China
OPTOTRONIC®
OT 120/220-240/12 P
Constant Voltage LED Power supply for 12V LED - Modules
Wiring and Connection






Ensure that the LED module load is within the range of rated voltage, current and power
(see Technical data)
Maximum output cable length is limited by EMI and cross diameter
Use output cable sections adequate to the load demand
The luminaire manufacturer is responsible for providing the required clearances and creepage
distances and also for protection against electrical shock, especially for the line and load wires
Please avoid direct exposure of sunlight and in case of exposure to UV rays, protect the cables with
suitable silicone sheath.
Not used output cables have to be insulated separately
Earth Connection


Protective earth connection of OT 120/12 P is mandatory for safety and EMI reasons
The ground connection has to be done via the input cable
Mounting and Environmental protection


The control gear is a built in type for luminaire integration
Maximum permissible ambient temperature must not be exceeded. Make sure there is adequate
space to avoid a build-up of heat. In critical installations the temperature at tc has to be controlled
General Note



Power supplies must be installed by a qualified electrician
Disconnected from mains supplies before wiring work
For further information see also “OPTOTRONIC – Technical guide” at www.osram.com