* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download brochure
Spark-gap transmitter wikipedia , lookup
Wireless power transfer wikipedia , lookup
Power over Ethernet wikipedia , lookup
Stepper motor wikipedia , lookup
Power factor wikipedia , lookup
Audio power wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electric power system wikipedia , lookup
Immunity-aware programming wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrification wikipedia , lookup
Power inverter wikipedia , lookup
Electrical ballast wikipedia , lookup
Current source wikipedia , lookup
Electrical substation wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
Power engineering wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Power MOSFET wikipedia , lookup
Schmitt trigger wikipedia , lookup
Three-phase electric power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Distribution management system wikipedia , lookup
Voltage regulator wikipedia , lookup
Surge protector wikipedia , lookup
Buck converter wikipedia , lookup
Opto-isolator wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Alternating current wikipedia , lookup
We are introducing ANYSES ESD (Energy Saving Device) constantly needs of minimizing carbondioxide emission because of global warming Need saving electricity for peak power consumption during summer and winter Increasing oil price cause Increasing electricity price Providing variable environment can save electricity to overcome the limit of manual power saving, and Applying efficient economical saving system Nation wide Energy Saving - Carbon Dioxide Cash-back System - OECD recommend increase electricity price - Regulation of energy consumption is getting stronger - 97% of Energy imported - Consumption quarter for building - Substitute products for increasing electric price - Assign Carbon dioxide emission control country - Smart energy metering system What is Anyses Anyses Product key technology, mutual Induction Reactor, enable to control power that providing electronic devices (ex ; lights, motor). So that saves electric consumption with controlling voltage and current that providing to load. Principle of Anyses There is 2 coils, 1st is voltage coil, and 2nd is current coil. If voltage apply to 1st voltage coil, current will move reverse direction on 2nd current coil, and current will induce voltage coil. And then, voltage coil current will increase and will flow to output. Increased amount will feedback to decreasing input current for the effect of mutual Induction Reactor Power saving device. It increase saving rate with automatically control few TAPs, and it can by-pass because serial connection. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) The feedback current(n2/n1) will be add to output whereas decrease input current because of mutual induction effect between voltage coil n1(V coil) and current coil n2 (I coil) Anyses saving power recursing induction current that created on 2nd coil to 1st voltage coil Proving Voltage have maximum +-10% variance for the reason of transmission line condition P=I.V.θ This equation shows that consuming power (P) is proportional with voltage(V) in case of continuous load and power factor(θ). ANYSES product saves consuming power with TAP and dropping voltage in case input voltage is higher than configuration. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) Transmission Diagram Electricity generated from power station increase voltage up to 345KV to send long distance. And then decrease voltage 154KV~22.9KV in substation. And then decrease voltage again 3 phase 380V or single phase 220V near client sites. The power saving concept of Anyses Power saving is to conserve electricity by reducing or getting rid of unnecessary power consumption. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) In general, electrical device or facilities are designed to have 1.2 ~ 1.5 times more reserves by taking safety levels and a drop in efficiency into consideration. So, they consume more than necessary power. Anyenergy enable varied devices and facilities to reduce their power consumption through the controlling of voltage levels within the required operating ranges and by improving power factors. It is a reliable power saving system that enables devices and facilities to last longer. ▪ Capability to curve the motor while controlling the authenticated voltage level The power saving principle Power supply The “Electricity Utilities industry Law” stipulates that for 220V level, the standard voltage supplied by a power supplier shall range within ±26V from 354V to 406V. The supply voltage level will differ depending on its regional areas. In general, when there is a drop in voltage is within an accepted deviation of standard voltage mentioned above. As for devices using 220V or 380V, standard voltage should range within ±10% from 198V to 242V and from 342V to 418V, respectively, for normal use and performance as defined in specs. Power saving principle Anyenergy is a power saving system that controls voltage and currents at the same time concerning the motor and lamps. This system checks whether the motor has the proper voltage levels needed for loading rate, limits the starting current, balances the three-phases and enhances the power factor. Through these functions, this system improves the quality of the power as a whole by bringing about a synergy effect. As for illumination actions, it maintains a proper brightness and lamp current, and copes automatically with the changes in input voltage levels. Of course, Anyenergy is a reactor-style power saving system that protects load devices while extending their life span. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) The performance Anyses - Automatic voltage Regulation - Phase Balancing - Extending Life Span - Remove Noise and Harmonics - Power Factor Correlation ▪ Saving electrical charges(Payback period : 1.5 ~ 2years / It lasts more than 15years) ▪ Protecting various electrical devices ▪ Being equipped with various protection systems(UV, OL, IOC, TH) Experience 10~25% saving effect your monthly electric bill It saves electric cost in your home or work place with controlling voltage and current and maintain right voltage. - Saving 10~25% electricity consume - Protecting sensitive electrical devices or equipment - Improve power factor - Reducing consuming power on inductive load(like motor) - Eliminating harmonics that can damage your devices - Eliminating electrical noises ANYSES, a power saving system for households and stores Let’s make ready for electrical charges in a progressive system! Electrical charges applied to various households in Korea, which is less than half of those applied to OECD member countries on average, are charged on a progressive system and privatization of Korea Electric Power Corporation will push up its charges. Anyenergy, the star of power saving for households, can save up to 25% of household electrical charges. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) Type House/Store Small and Medium-sized Consuming voltage 220V 380 / 220V Consuming frequency 50Hz 50Hz Type of receiving electricity Single-phase Three-phase single-phase Production capacity 3KVA ~ 50KVA 20KVA ~ 150KVA Available currents 10 ~ 225A 30 ~ 225A Voltage regulating range (-3%)~(-6%) (-3%)~(-6%) How to regulate voltage TAP1 ~ TAP2 TAP1 ~ TAP3 A power saving system for households and you can have electric charge saved by 30%! How much is saved per month after Anyses is installed Type Consuming volume Electrical charge Consuming volume Electrical charge Consuming volume Electrical charge Remarkers Before installation After installation 330KWH 280KWH $53 $37 440KWH 398KWH $98 $75 470KWH 400KWH $111 Power saving late Money saved Money saved percentage 15% $16/month 30% 10% $22/month 23% 15% $34/month 31% $77 1. Korea electricity power corporation applying the progressive charge system for households 2. Extention of the lite span electric device and noise reduction 3. Power saving rate differs depending on input voltage Saving electrical charges by 10~25% with patented MIR(Mutual Inductive Reactor) effect Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) Advantages 1. Excellent cost efficiency-It can be used in complex loads. Since a highly efficient Toroidal Core is used, the System maximizes its power Saving ability, And it is easy lo install and manage because the system is directly Connected in 1 a s fuse box. 2, Extending the life span of various electricity loads via the AVR (automatic voltage regulators) system. The systems built-in light protection System extends the life span of load devices by maintaining a specific voltage level and by balancing the three phases within the available voltage ranges. 3. Reduce Harmonica It eliminate more then 50% voltage end current Harmonics, So that it save your electronics from the unexpected impact. Guarantees of product safety and reliability Specification of Anyses for complex load Type Speccifications Remarks 220V, 380V, 440V Threephases Voltage or e surge in load, if connects input power into load immediately with a Consuming voltage Consuming Frequency production capacity Available currents by-pass System coming into operation. Core type Toroidal (Wonunding) No-load loss Below 45W Total loss Below 0.5% 1. It protects devices against output voltage (UV) while Anyses is operating, if the output voltage goes down below the Set-up voltage level because 01 a drop in input 2, It Provides protection from overload(OV), overcurrent(IOC) and overheat(TH) During the operation01 Anyses, the prediction function and by-pass System come into operation and protect devices and lo supply stable power to load if overload or overcurrent is caused by any Voltage regulating range How to regulate voltage 50HZ 4KVA~2000KVA 380V 15A~3000A Threephase 300K (-3%)~(-6%) TAP1 ~ TAP3 R. S. T phase Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) operating mistakes. Exterior material 3, The prediction tunction and automatic return tunction How to install item Steel, Hammer tone coating SUS Parallel(Basic), series Spray coating In the cases of the above mentioned lists, Anyses puls its prediction function into operation and automatically switche its by- Type Volum(KVA) Size(mm) A type 30 W460*H600*L180 50 W500*H700*L200 30 W500*H700*L420 50 W500*H700*L420 75 W550*H750*L450 B 100 W550*H750*L450 type 140 W580*H780*L450 300 W750*H1750*L900 500 W750*H2000*L850 1000 W900*H2200*L1100 pass system into operation, in addition, it is designed la supply power normally even when after-sales service is needed. - Various protection tunctions and control circuit can be applied differently depending an use. - As the product is less economical under 214V, please 3pply it with greats care. - when installing the product, please let a qualified engineer install it. Power-saving device fabrication specifications and electrical characteristics 1. Coverage Anyses Power-saving devices are Indoor wall-mounted type, ambient temperature of -5℃+ 30℃, and should be installed less than 1000m above sea level. 2. Electrical Specification ▪ 30/50Kva a. Input Voltage : 3phase 4lines 380V/220V 50HZ b. allowed Current : 46A/76A c. Output Voltage : 3phase 4lines 380V/220V 50HZ d. Output Voltage Range : 380V - 359V e. Technology for Variable Output Voltage : Automatic TAP Change Method(AVR) f. Capacity : 30KVA /50KVA ▪ households & stores a. Input Voltage : single phase 2 lines 220V b. allowed Voltage : 215V~223V 50HZ c. Permit Current : 27.3A Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) d. Output Voltage Range : single phase 208V - 212V 50Hz e. Technology for Variable Output Voltage : Automatic TAP Change Method(AVR) f. Capacity : 6KVA / 11KVA 3. Front Display a. POWER ON LAMP b. DIRECT CONNECTION LAMP c. MANUAL / AUTO S/W d. SAVE MODE LAMP e. EMERGENCY LAMP f. KW METER DIGITAL (optional) 4. Structure ▪ 30/50Kva a. dimension : 500mm X 420mm X 700mm b. material & : 1.6t thickness steel with front door c. painting : 7.5BG 6/1.5 ▪ households & stores a. Nonflammable Plastic enclosed type b. W 295 m/m * D 245 m/m * H 92m/m 5. Electrical System a. By-pass function operate automatically without blackout if output voltage is lower than 359V(can be changed) b. Mounted temperature sensor work with By-pass function and Emergency Lamp when it detect high temperature c. TAP can be changed to maximize Power Saving Rate d. It can generate stable 3 phase output voltage even input voltage is not same. 6. Check Items a. Check delivered Item is same specification b. Input Voltage 384V (Automatic TAP1) : check output voltage 359V each phase c. Input Voltage 378V (Automatic TAP2) : check output voltage 359V each phase d. Input Voltage 371V (Automatic TAP3) : check output voltage 359V each phase e. Input Voltage 370V (Bypass) : check output voltage 370V each phase f. Disconnect R,S,T (Bypass) : check bypass function when blackout only one phase g. Registance(isolation) test should be 500V mega //5M h. Internal Voltage Test should be tested with regular frequency and 2000V for 1 minute (except Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960) PCB and control circuit) i. Load test have to be passed with regular voltage and current (below 80C) 7. Other Item a. The items that not decribed here will follow Electrical Installation Technology Standard "INSTALLATION & OPERATION MANUAL" 1. Installation a. Off 'NFD' on input Power b. turn to Manual on MAN/AUTO Switch c. Check input power is 3 phase 4line, and Connect input power connection d. Connect loads connection on output terminal e. turn on in-out power f. Check input voltage from voltage meter or other equipment, TURN TO AUTO Mode if voltage is normal. And then SAVE mode will work after certain time. If input voltage is lower than standard(370V), it will stay on MAN." g. if the input voltage is less than 370V DIR Mode, higher than 370V SAVE Mode will work. h. If there is abnormal temperature increase during AUTO Mode, ALARM LAMP will turn on and will not work SAVE Mode. After check the reason of abnormal temperature, TURN TO MANUAL MODE AND TRY AUTO MODE AGAIN. 2. Trouble shooting a. In case of overheating, automatically Direct mode is working with EMERGENCY LAMP. Turn to MAN on MAN/AUTO switch, and check the heating reason or problem. And Inquire Service Center." b. It can be bypass in case of PCB contact problem. Turn to manual mode, check the voltage differences between FUSE. And turn on AUTO Mode. c. Inquire local dealer or manufacture in case of any other problem or need services. Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected] T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)