Download brochure

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Spark-gap transmitter wikipedia , lookup

Wireless power transfer wikipedia , lookup

Power over Ethernet wikipedia , lookup

Decibel wikipedia , lookup

Stepper motor wikipedia , lookup

Power factor wikipedia , lookup

Audio power wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electric power system wikipedia , lookup

Immunity-aware programming wikipedia , lookup

Pulse-width modulation wikipedia , lookup

Electrification wikipedia , lookup

Ohm's law wikipedia , lookup

Power inverter wikipedia , lookup

Electrical ballast wikipedia , lookup

Current source wikipedia , lookup

Electrical substation wikipedia , lookup

Islanding wikipedia , lookup

Amtrak's 25 Hz traction power system wikipedia , lookup

Power engineering wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Triode wikipedia , lookup

Power MOSFET wikipedia , lookup

Rectifier wikipedia , lookup

Schmitt trigger wikipedia , lookup

Three-phase electric power wikipedia , lookup

History of electric power transmission wikipedia , lookup

Metadyne wikipedia , lookup

Distribution management system wikipedia , lookup

Voltage regulator wikipedia , lookup

Surge protector wikipedia , lookup

Buck converter wikipedia , lookup

Opto-isolator wikipedia , lookup

Stray voltage wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Alternating current wikipedia , lookup

Voltage optimisation wikipedia , lookup

Mains electricity wikipedia , lookup

Transcript
We are introducing ANYSES
ESD (Energy Saving Device)
constantly needs of
minimizing carbondioxide emission because
of global warming
Need saving electricity for
peak power consumption
during summer and winter
Increasing oil price cause
Increasing electricity price
Providing variable environment can save electricity to overcome the limit of manual power
saving, and Applying efficient economical saving system
Nation wide Energy Saving
- Carbon Dioxide Cash-back System
- OECD recommend increase electricity price
- Regulation of energy consumption is getting stronger
- 97% of Energy imported
- Consumption quarter for building
- Substitute products for increasing electric price
- Assign Carbon dioxide emission control country
- Smart energy metering system
What is Anyses
Anyses Product key technology, mutual Induction Reactor, enable to control power that providing
electronic devices (ex ; lights, motor). So that saves electric consumption with controlling voltage
and current that providing to load.
Principle of Anyses
There is 2 coils, 1st is voltage coil, and 2nd is current coil. If voltage
apply to 1st voltage coil, current will move reverse direction on 2nd current coil, and current will
induce voltage coil. And then, voltage coil current will increase and will flow to output. Increased
amount will feedback to decreasing input current for the effect of mutual Induction Reactor Power
saving device.
It increase saving rate with automatically control few TAPs, and it can by-pass because serial
connection.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
The feedback current(n2/n1) will be add to output whereas decrease input current because of mutual
induction effect between voltage coil n1(V coil) and current coil n2 (I coil)
Anyses saving power recursing induction current that created on 2nd coil to 1st voltage coil Proving
Voltage have
maximum +-10% variance for the reason of transmission line condition P=I.V.θ
This equation shows that consuming power (P) is proportional with voltage(V) in case of continuous
load and power factor(θ). ANYSES product saves consuming power with TAP and dropping voltage
in case input voltage is higher than configuration.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
Transmission Diagram
Electricity generated from power station increase voltage up to 345KV to send long distance. And
then decrease voltage 154KV~22.9KV in substation.
And then decrease voltage again 3 phase 380V or single phase 220V near client sites.
The power saving concept of Anyses
Power saving is to conserve electricity by reducing or getting rid of unnecessary power consumption.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
In general, electrical device or facilities are designed to have 1.2 ~ 1.5 times more reserves by
taking safety levels and a drop in efficiency into consideration. So, they consume more than
necessary power.
Anyenergy enable varied devices and facilities to reduce their power consumption through the
controlling of voltage levels within the required operating ranges and by improving power factors. It
is a reliable power saving system that enables devices and facilities to last longer.
▪ Capability to curve the motor while controlling the authenticated voltage level
The power saving principle
Power supply
The “Electricity Utilities industry Law” stipulates that for 220V level, the standard voltage supplied by
a power supplier shall range within ±26V from 354V to 406V.
The supply voltage level will differ depending on its regional areas. In general, when there is a drop
in voltage is within an accepted deviation of standard voltage mentioned above. As for devices
using 220V or 380V, standard voltage should range within ±10% from 198V to 242V and from 342V
to 418V, respectively, for normal use and performance as defined in specs.
Power saving principle
Anyenergy is a power saving system that controls voltage and currents at the same time concerning
the motor and lamps. This system checks whether the motor has the proper voltage levels needed
for loading rate, limits the starting current, balances the three-phases and enhances the power
factor. Through these functions, this system improves the quality of the power as a whole by
bringing about a synergy effect. As for illumination actions, it maintains a proper brightness and
lamp current, and copes automatically with the changes in input voltage levels. Of course,
Anyenergy is a reactor-style power saving system that protects load devices while extending their
life span.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
The performance Anyses
- Automatic voltage Regulation
- Phase Balancing
- Extending Life Span
- Remove Noise and Harmonics
- Power Factor Correlation
▪ Saving electrical charges(Payback period : 1.5 ~ 2years / It lasts more than 15years)
▪ Protecting various electrical devices
▪ Being equipped with various protection systems(UV, OL, IOC, TH)
Experience 10~25% saving effect your monthly electric bill
It saves electric cost in your home or work place with controlling voltage and current and maintain
right voltage.
- Saving 10~25% electricity consume
- Protecting sensitive electrical devices or equipment
- Improve power factor
- Reducing consuming power on inductive load(like motor)
- Eliminating harmonics that can damage your devices
- Eliminating electrical noises
ANYSES, a power saving system for households and stores
Let’s make ready for electrical charges in a progressive system!
Electrical charges applied to various households in Korea, which is less than half of those applied
to OECD member countries on average, are charged on a progressive system and privatization of
Korea Electric Power Corporation will push up its charges. Anyenergy, the star of power saving for
households, can save up to 25% of household electrical charges.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
Type
House/Store
Small and
Medium-sized
Consuming
voltage
220V
380 / 220V
Consuming
frequency
50Hz
50Hz
Type of
receiving
electricity
Single-phase
Three-phase
single-phase
Production
capacity
3KVA ~ 50KVA
20KVA ~ 150KVA
Available
currents
10 ~ 225A
30 ~ 225A
Voltage
regulating
range
(-3%)~(-6%)
(-3%)~(-6%)
How to regulate
voltage
TAP1 ~ TAP2
TAP1 ~ TAP3
A power saving system for households and you can have
electric charge saved by 30%!
How much is saved per month after Anyses is installed
Type
Consuming
volume
Electrical
charge
Consuming
volume
Electrical
charge
Consuming
volume
Electrical
charge
Remarkers
Before
installation
After
installation
330KWH
280KWH
$53
$37
440KWH
398KWH
$98
$75
470KWH
400KWH
$111
Power
saving late
Money saved
Money saved
percentage
15%
$16/month
30%
10%
$22/month
23%
15%
$34/month
31%
$77
1. Korea electricity power corporation applying the progressive charge system
for households
2. Extention of the lite span electric device and noise reduction
3. Power saving rate differs depending on input voltage
Saving electrical charges by 10~25% with patented MIR(Mutual Inductive Reactor) effect
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
Advantages
1. Excellent cost efficiency-It can be used in
complex loads.
Since a highly efficient Toroidal Core is used,
the System maximizes its power Saving ability,
And it is easy lo install and manage because
the system is directly Connected in 1 a s fuse
box.
2, Extending the life span of various electricity
loads
via
the
AVR
(automatic
voltage
regulators) system. The systems built-in light
protection System extends the life span of
load devices by maintaining a specific voltage
level and by balancing the three phases within
the available voltage ranges.
3. Reduce Harmonica
It eliminate more then 50% voltage end current
Harmonics, So that it save your electronics
from the unexpected impact.
Guarantees of product safety and
reliability
Specification of Anyses for complex load
Type
Speccifications
Remarks
220V, 380V,
440V
Threephases
Voltage or e surge in load, if connects
input power into load immediately with a
Consuming
voltage
Consuming
Frequency
production
capacity
Available
currents
by-pass System coming into operation.
Core type
Toroidal
(Wonunding)
No-load
loss
Below 45W
Total loss
Below 0.5%
1. It protects devices against output voltage
(UV)
while Anyses is operating, if the output
voltage goes down below the Set-up
voltage level because 01 a drop in input
2, It Provides protection from overload(OV),
overcurrent(IOC) and overheat(TH)
During the operation01 Anyses, the
prediction function and by-pass System
come into operation and protect devices
and lo supply stable power to load if
overload or overcurrent is caused by any
Voltage
regulating
range
How to
regulate
voltage
50HZ
4KVA~2000KVA
380V
15A~3000A
Threephase 300K
(-3%)~(-6%)
TAP1 ~ TAP3
R. S. T
phase
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
operating mistakes.
Exterior
material
3, The prediction tunction and automatic
return tunction
How to
install item
Steel, Hammer
tone coating
SUS
Parallel(Basic),
series
Spray
coating
In the cases of the above mentioned lists,
Anyses puls its prediction function into
operation and automatically switche its by-
Type
Volum(KVA)
Size(mm)
A
type
30
W460*H600*L180
50
W500*H700*L200
30
W500*H700*L420
50
W500*H700*L420
75
W550*H750*L450
B
100
W550*H750*L450
type
140
W580*H780*L450
300
W750*H1750*L900
500
W750*H2000*L850
1000
W900*H2200*L1100
pass system into operation, in addition, it
is designed la supply power normally even
when after-sales service is needed.
- Various protection tunctions and control
circuit can be applied differently
depending an use.
- As the product is less economical under
214V, please 3pply it with greats care.
- when installing the product, please let a
qualified engineer install it.
Power-saving device fabrication specifications and electrical characteristics
1. Coverage
Anyses Power-saving devices are Indoor wall-mounted type, ambient temperature of -5℃+ 30℃,
and should be installed less than 1000m above sea level.
2. Electrical Specification
▪ 30/50Kva
a. Input Voltage : 3phase 4lines 380V/220V 50HZ
b. allowed Current : 46A/76A
c. Output Voltage : 3phase 4lines 380V/220V 50HZ
d. Output Voltage Range : 380V - 359V
e. Technology for Variable Output Voltage : Automatic TAP Change Method(AVR)
f. Capacity : 30KVA /50KVA
▪ households & stores
a. Input Voltage : single phase 2 lines 220V
b. allowed Voltage : 215V~223V
50HZ
c. Permit Current : 27.3A
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
d. Output Voltage Range : single phase 208V - 212V 50Hz
e. Technology for Variable Output Voltage : Automatic TAP Change Method(AVR)
f. Capacity : 6KVA / 11KVA
3. Front Display
a. POWER ON LAMP
b. DIRECT CONNECTION LAMP
c. MANUAL / AUTO S/W
d. SAVE MODE LAMP
e. EMERGENCY LAMP
f. KW METER DIGITAL (optional)
4. Structure
▪ 30/50Kva
a. dimension : 500mm X 420mm X 700mm
b. material & : 1.6t thickness steel with front door
c. painting : 7.5BG 6/1.5
▪ households & stores
a. Nonflammable Plastic enclosed type
b. W 295 m/m * D 245 m/m * H 92m/m
5. Electrical System
a. By-pass function operate automatically without blackout if output voltage is lower than
359V(can be changed)
b. Mounted temperature sensor work with By-pass function and Emergency Lamp when it
detect high temperature
c. TAP can be changed to maximize Power Saving Rate
d. It can generate stable 3 phase output voltage even input voltage is not same.
6. Check Items
a. Check delivered Item is same specification
b. Input Voltage 384V (Automatic TAP1) : check output voltage 359V each phase
c. Input Voltage 378V (Automatic TAP2) : check output voltage 359V each phase
d. Input Voltage 371V (Automatic TAP3) : check output voltage 359V each phase
e. Input Voltage 370V (Bypass) : check output voltage 370V each phase
f. Disconnect R,S,T (Bypass) : check bypass function when blackout only one phase
g. Registance(isolation) test should be 500V mega //5M
h. Internal Voltage Test should be tested with regular frequency and 2000V for 1 minute (except
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)
PCB and control circuit)
i. Load test have to be passed with regular voltage and current (below 80C)
7. Other Item
a. The items that not decribed here will follow Electrical Installation Technology Standard
"INSTALLATION & OPERATION MANUAL"
1. Installation
a. Off 'NFD' on input Power
b. turn to Manual on MAN/AUTO Switch
c. Check input power is 3 phase 4line, and Connect input power connection
d. Connect loads connection on output terminal
e. turn on in-out power
f. Check input voltage from voltage meter or other equipment, TURN TO AUTO Mode if voltage is
normal. And then SAVE mode will work after certain time.
If input voltage is lower than standard(370V), it will stay on MAN."
g. if the input voltage is less than 370V DIR Mode, higher than 370V SAVE Mode will work.
h. If there is abnormal temperature increase during AUTO Mode, ALARM LAMP will turn on and
will not work SAVE Mode. After check the reason of abnormal temperature, TURN TO
MANUAL MODE AND TRY AUTO MODE AGAIN.
2. Trouble shooting
a. In case of overheating, automatically Direct mode is working with EMERGENCY LAMP.
Turn to MAN on MAN/AUTO switch, and check the heating reason or problem. And Inquire
Service Center."
b. It can be bypass in case of PCB contact problem. Turn to manual mode, check the voltage
differences between FUSE. And turn on AUTO Mode.
c. Inquire local dealer or manufacture in case of any other problem or need services.
Tel. 82.70.4028.3432 | Fax. 82.2.6401.6100 | e-mail. [email protected]
T9010, Garden 5 Life, Chungmin-ro 66, Songpa-gu, Seoul, Korea (zip.138-960)