* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download The Resolving Power Of a Microscope and Telescope
Lens (optics) wikipedia , lookup
Astronomical spectroscopy wikipedia , lookup
Vibrational analysis with scanning probe microscopy wikipedia , lookup
Diffraction grating wikipedia , lookup
Nonimaging optics wikipedia , lookup
Surface plasmon resonance microscopy wikipedia , lookup
Diffraction topography wikipedia , lookup
Retroreflector wikipedia , lookup
X-ray fluorescence wikipedia , lookup
Image stabilization wikipedia , lookup
Very Large Telescope wikipedia , lookup
Anti-reflective coating wikipedia , lookup
Dispersion staining wikipedia , lookup
Photon scanning microscopy wikipedia , lookup
Johan Sebastiaan Ploem wikipedia , lookup
Optical telescope wikipedia , lookup
Super-resolution microscopy wikipedia , lookup
Harold Hopkins (physicist) wikipedia , lookup
Solution 2.6.1. Resolving power of a Microscope: The primary utility of a microscope is not to magnify an object but to reveal the finer details which are not visible in the unaided eye. The resolving power of a microscope decides the extent to which finer details of an object can be revealed. However, let us find the resolving power of a microscope for resolving two non-coherent self-luminous objects (A and B). n1 n2 B A i r r A’ B’ Fig. S2.6.1. The formation of image and resolving power of a microscope objective. Let the diameter of the lens used is D and the distance of the two non-luminous point objects A and B is h and the distance between their respective image is A’B’ =h’. Also let the refractive index of the two media before lens and after lens are n1 and n2, respectively. Assuming the absence of any spherical aberration, there will be two Airy patterns (as discussed in the case of diffraction in a circular aperture) as shown in the Figures. Now by using the Rayleigh’s criteria for resolving power we can calculate the condition for which the point A and B will be clearly resolved is, sin r = 1.22 m/D = 1.22 /n2D. Here, m is the wavelength of the light in the image space and is the wavelength of the light in the free space. However, after some step it can be shown that, h = 0.61n1 sin i. The above expression gives the smallest distance that the microscope can resolve. The above equation shows that the smallest distance that can be resolved or the resolving power of the microscope depends proportionately on the wavelength, i.e. smaller the wavelength better is the resolving power or limit of resolution for imaging in a microscope. (For observing nanostructured materials, such as with sizes even up to 1 nm, electron beam is used in Electron Microscopes where electrons are accelerated to a very high voltage of several kV, thus very small wavelength is achieved). For further details, please see , Optics (3rd Edn., A. Ghatak, Tata Mc-Graw Hill), Ch. 16, pp. 16.17. The Resolving Power Of a Microscope and Telescope December 29, 2015Leave a Comment Diffraction limit When a point object is imaged using a circular opening (or aperture) like a lens or the iris of our eye, the image formed is not a point but a diffraction pattern. This is true particularly when the size of the object is comparable to the wavelength of light. Just as in single slit diffraction (click the link for more info), a circular aperture produces a diffraction pattern of concentric rings that grow fainter as we move away from the centre. These are known as Airy’s discs. Because of this point sources close to one another can overlap and produce a blurred image. The half angle θ subtended by the first minimum at the source is given by the relation sinθ ≈ 1.22 λd To obtain a good image, point sources must be resolved i.e., the point sources must be imaged such that their images are sufficiently far apart that their diffraction patterns do not overlap. For this the minimum distance between images must be such that the central maximum of the first image lies on the first minimum of the second and vice versa. Such an image is said to be just resolved. This is the famousRayleigh criterion. The criterion is given by the above formula as: sin θR ≈ θR≈ 1.22 λd The first image is fully resolved, the second just resolved and third unresolved. Resolving power It is defined as the inverse of the distance or angular separation between two objects which can be just resolved when viewed through the optical instrument. Resolving power of a telescope In telescopes, very close objects such as binary stars or individual stars of galaxies subtend very small angles on the telescope. To resolve them we need very large apertures. We can use the Rayleigh’s to determine the resolving power. The angular separation between two objects must be △θ = 1.22 λd Resolving power = 1△θ = d1.22 λ Thus higher the diameter d, better the resolution. The best astronomical optical telescopes have mirror diameters as large as 10m to achieve the best resolution. Also larger wavelengths reduce the resolving power and consequently radio and microwave telescopes need larger mirrors. Resolving power of a microscope For microscopes, the resolving power is the inverse of the distance between two objects that can be just resolved. This is given by the famous Abbe’s criterion given by Ernst Abbe in 1873 as △ d = λ2 n sin θ Resolving power = 1△ d = 2n sin θλ Where n is the refractive index of the medium separating object and aperture. Note that to achieve high resolution n sin θ must be large. This is known as the Numerical aperture. Thus, for good resolution: 1. sin θ must be large. To achieve this, the objective lens is kept as close to the specimen as possible. 2. A higher refractive index (n) medium must be used. Oil immersion microscopes use oil to increase the refractive index. Typically for use in biology studies this is limited to 1.6 to match the refractive index of glass slides used. (This limits reflection from slides). Thus the numerical aperture is limited to just 1.4-1.6. Thus, optical microscopes (if you do the math) can only image to about 0.1 micron. This means that usually organelles, viruses and proteins cannot be imaged. 3. Decreasing the wavelength by using X-rays and gamma rays. While these techniques are used to study inorganic crystals, biological samples are usually damaged by x-rays and hence are not used. The limit set by Abbe’s criterion for optical microscopy cannot be avoided. However, using different fluorescence microscopy techniques the Abbe’s limit can be circumvented. Stefan Hell used a technique called Simulated Emission Depletion (STED) and the duo Eric Betzig and W.E. Moerner used super imposed images using green fluorescent proteins to bypass the resolution limit and obtain optical images in never before seen resolution. All three were awarded the 2014 Nobel Prize in Chemistry for their pioneering work.