* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Datasheet - Pump Centre
Electric power system wikipedia , lookup
Mercury-arc valve wikipedia , lookup
Current source wikipedia , lookup
Power inverter wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Resistive opto-isolator wikipedia , lookup
Electrical ballast wikipedia , lookup
Power engineering wikipedia , lookup
Pulse-width modulation wikipedia , lookup
Electrification wikipedia , lookup
Induction motor wikipedia , lookup
Amtrak's 25 Hz traction power system wikipedia , lookup
History of electric power transmission wikipedia , lookup
Buck converter wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical substation wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Opto-isolator wikipedia , lookup
Distribution management system wikipedia , lookup
Power electronics wikipedia , lookup
Stray voltage wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Stepper motor wikipedia , lookup
Surge protector wikipedia , lookup
Portable appliance testing wikipedia , lookup
Voltage optimisation wikipedia , lookup
Mains electricity wikipedia , lookup
Alternating current wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Earthing system wikipedia , lookup
WIMES 3.04 Page 59 APPENDIX C1 - DATA SHEETS PACKAGE PLANT (ELECTRICAL) PROJECT TITLE (P) PROJECT NUMBER (P) PROJECT LOCATION (P) PACKAGE PLANT SUPPLIER (P/S) * - indicates Purchaser’s default requirement 3.0 OPERATING ENVIRONMENT AND SERVICE CONDITIONS 1 3 Operating Environment (P) Site Location () Inland Coastal Package Plant Location () Indoors Outdoors Other (specify) Hazardous Area Classification () Non hazardous Zone 1 Zone 2 EMC Environment () 1st environment – C1 1st environment – C2 2nd environment – C3 Special Service Conditions (P) DOCUMENT REFERENCE (P) REVISION (P) DATE (P) REFERENCE DRAWINGS INCLUDED (Y/N) (P) 4.0 ELECTRICAL SYSTEM CHARACTERITICS (CONTD.) c d e f 4.0 ELECTRICAL SYSTEM CHARACTERITICS 1 a b Electrical System Characteristics (P) Supply Arrangement () Single source Multiple source (specify sources and operating arrangement elsewhere) Supply Voltage, Frequency and Number of Phases () 400 V, 3 phase, 50 Hz 3 wire 4 wire Other (specify) ISSUE 5 g Prospective Fault Current (kA) (max) Phase to phase Phase to neutral Phase to earth Type of Earthing System () TN-S TN-C-S (PME) TT Other (specify) Earth Fault Loop Impedance (Ohms) Ze Type and Rating of the Upstream Protective Device () None Circuit breaker Fuse Number of poles BS Type Overcurrent rating (A) Earth fault rating (A) Earth fault time delay (secs) Other arrangement (specify) Supply Cable Characteristics BS Type Copper conductors Rating (A) Phase CSA (mm2) Neutral CSA (mm2) Earth CSA (mm2) MARCH 2014 WIMES 3.04 2 3 4 6 Page 60 6.2.4 Construction Overvoltage Category (III*) (P) Assumed Voltage Drop for Package Plant (V) (P) Supply Restrictions (P) Lightning and Requirements (P) 6.2.4.1 General Surge Protection 5.0 PERFORMANCE SPECIFICATION 3 Minimum Design (20 years*) (P) 3 Material(s) of Construction (Including Details of Any Protective Coatings) (P/S) 4 a b 6 Type of Assembly Construction () (P/S) Cubicle/multi-cubicle Box/multi-box Degree of Ingress Protection (IP Code) (P/S) Size/Weight Restrictions (P) 7 Life 6.0 DESIGN SPECIFICATION 6.2.4.5 Mounting Arrangements 6.1 General 1 6.1.1 General and Safety Requirements 3 Method of Fault Protection (ADS*) (P/S) Mounting Arrangements () (P/S) Skid/frame mounted Wall mounted Other (specify) 6.2.5 Earthing and Bonding 6.1.6 O & M Manuals 4 1 Reference for O & M Manual Specification ([P) Separate Earth Bars/ Studs Required (Y/N) (P) 6.2.6 Cabling and Wiring 6.2.6.1 General 6.2 The Assembly 3 6.2.1 General 2 5 7 Form of Internal Separation (P/S) Form 2 assemblies (2a or 2b) Form 4 assemblies (4a or 4b) Control Circuit Test Facilities () (S) Internal push-button Test position on switching and isolation device Diversity factor (S) Ratio of CSAs of Neutral and Line Conductors (100 %*) (P) 6.2.2 Electrical Components 4 Component (P) ISSUE 5 Details (S) MARCH 2014 WIMES 3.04 Page 61 6.2.7 Requirements for Specific Components 6.2.8.2 Motor Starters 6.2.7.1 Indicating Lamps Refer to APPENDIX C2 2 Lamp Colours/Meanings (P) Available/auto-available Supply on Running Stopped Emergency stop Dangerous condition Normal condition Alarm Tripped/fault 6.2.8.3 Control Circuit Supplies white CCS Voltage (P/S) 6.2.8.4 ICA Equipment General red yellow/ amber yellow/ amber On Off Process indicators 6.2.7.2 Push-Button and Control Switches 1 3 Push Button Switch Colours/Meanings (P) Start Stop Reset Emergency stop red Inch Lamp test Closed Open On Off 10 Type of HMI Required/Provided (P/S) 11 Method of Connecting Package Plant to Site Control System () (P) Hardwired Remote I/O unit Fieldbus connection Reference for Purchaser’s Particular Specification 11 Low Voltage and Extra Low Voltage Systems 1 Type and Configuration of LV and ELV Systems (P/S) Lighting and Socket Outlets 1 Lighting Facilities Required (Y/N) (P) PLC 1 PLC Provided (Y/N) (S) 6.2.8.5 Uninterruptible Power Supply (UPS) 6.2.8 Functional Units 1 1 Method of Functional Unit Connection (P) 6.2.8.1 Incomer 1 Fuse Switch Rating & Configuration (S) Rating (A) 3 pole 3 pole + bolted neutral link 4 pole Short circuit capacity (kA) ISSUE 5 3 4 UPS Requirements () (P) None required Provided within Assembly Provided within a separate assembly Details of Loads to be Supported by the UPS (P) UPS Rating and Autonomy Time (110% and 15 minutes (min)) (P) MARCH 2014 WIMES 3.04 Page 62 6.2.8.6 Supervisory Control and Monitoring 2 7.2 Inspection and Testing of the Assembly Local & Remote Supervisory Control Signals Required/ Provided (P/S) Signal Description Signal Type1 7.2.1 General 1 a b Additional Tests Required () (P) Witness FATs Site commissioning tests 7.2.2 Factory Acceptance Tests (FATs) 1 3 a 1 – Volt-free (VF), Digital (D), Analogue (A) 3 Local & Remote Supervisory Monitoring Signals Required/Provided (P/S) Signal Description Type1 I/C2 b c d Samples of Supplier’s test schedules to be submitted before testing (Y/N) (P) Additional FATs Required () (P) Injection testing of incomer protection circuits Injection testing of motor starter protection circuits Response testing to simulated voltage dips Serial communication network testing 7.2.3 Witness Required) 2 a 1 – Volt-free (VF), Communications link (CL), Analogue (A) 2 – Individual (I), common (C) 6.2.10 Additional Assemblies Requirements for Form b 2 6.2.10.1 Construction 3 a i General ii 3 Distribution Board Location (P) iii 7.0 INSPECTION AND TESTING iv 7.1 General v 4 4 Package Plant to Include /be Included in a Fieldbus Network (Y/N) (P) Reference for Purchaser’s Specification (P) ISSUE 5 vi Particular vii Factory Acceptance Tests (If Availability/Distribution of Supplier’s Test Schedules (P) Schedules to be made available to the Purchaser at witness FATs Schedules to be sent to the Purchaser before witness FATs Witness FATs to Include () (P) Routine Tests to BS EN 61349 Constructional: Degree of protection of enclosures Clearance and creepage distances Protection against electric shock and integrity of protective circuits Incorporation of built in components Internal electric circuits and connections Terminals for external conductors Mechanical operation MARCH 2014 WIMES 3.04 i ii 3 i ii iii iv 4 5 Page 63 Performance: Dielectric properties Wiring, operational performance and function Additional Tests Injection testing of incomer protection circuits Injection testing of motor starter protection circuits Response testing to simulated voltage dips Serial communication network testing Details of Any Further Witness FATs Required (P) DOC (to BS EN 61439-2) to be Available at Witness FATs (Y/N) (P) 7.2.5 Site Commissioning Tests (If Required) 1 3 Tests to be Witnessed by the Purchaser (Y/N) (P) Details of Any Further Testing or Commissioning Activities Required (P) 7.3 Inspection and Testing of the Installation 7.3.1 General 3 Additional Inspection & Testing Reqd. (as Part of Process Commissioning) (Y/N) (P) ISSUE 5 MARCH 2014 WIMES 3.04 Page 64 APPENDIX C2 - MOTOR STARTER DATA SHEET PACKAGE PLANT (ELECTRICAL) DRIVE DESIGNATION ____________________ 1 Motor Starter Details (S) Type Direct-on-line Star delta Reversing Two speed Soft start/stop Variable speed Voltage 400 V 3 phase 230 V 1 phase Other (specify) Rating Output (kW) Full load current (A) Starting current (xFLC) Number of starts per hour Power Factor Uncorrected motor power factor DRIVE DESIGNATION ____________________ 1 Motor Starter Details (S) Type Direct-on-line Star delta Reversing Two speed Soft start/stop Variable speed Voltage 400 V 3 phase 230 V 1 phase Other (specify) Rating Output (kW) Full load current (A) Starting current (xFLC) Number of starts per hour Power Factor Uncorrected motor power factor ISSUE 5 DRIVE DESIGNATION ____________________ 1 Motor Starter Details (S) Type Direct-on-line Star delta Reversing Two speed Soft start/stop Variable speed Voltage 400 V 3 phase 230 V 1 phase Other (specify) Rating Output (kW) Full load current (A) Starting current (xFLC) Number of starts per hour Power Factor Uncorrected motor power factor DRIVE DESIGNATION ____________________ 1 Motor Starter Details (S) Type Direct-on-line Star delta Reversing Two speed Soft start/stop Variable speed Voltage 400 V 3 phase 230 V 1 phase Other (specify) Rating Output (kW) Full load current (A) Starting current (xFLC) Number of starts per hour Power Factor Uncorrected motor power factor MARCH 2014 WIMES 3.04 Page 65 APPENDIX D – SUPPLIER’S SUPPLEMENTARY DATA SHEET INFORMATION Clause ISSUE 5 Supplementary Information MARCH 2014