Download Printable Version of Questions for Evaluation Test
Portable appliance testing wikipedia , lookup
Stray voltage wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Brushed DC electric motor wikipedia , lookup
Electrical substation wikipedia , lookup
Voltage optimisation wikipedia , lookup
Induction motor wikipedia , lookup
Aluminium-conductor steel-reinforced cable wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Flexible electronics wikipedia , lookup
Rectiverter wikipedia , lookup
Stepper motor wikipedia , lookup
Skin effect wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Mains electricity wikipedia , lookup
Transmission tower wikipedia , lookup
Three-phase electric power wikipedia , lookup
Variable-frequency drive wikipedia , lookup
Alternating current wikipedia , lookup
Ground (electricity) wikipedia , lookup
Electrical wiring wikipedia , lookup
Electrical wiring in the United Kingdom wikipedia , lookup
Printable Version of Questions for Evaluation Test 1. When are you required to use an approved electrically conductive corrosion resistance compound on conduit threads? 2. Carnival and circus overhead wiring outside of tents and concession areas where the voltage-to-ground does not exceed 150V shall maintain a vertical clearance of ____________ above platforms, projections or surfaces from which they might be reached. 3. Class III locations are those that are hazardous because of the presence of _______________. 4. What is the feeder or service demand load for two 3 kW ranges? 5. If the transfer switch for a portable generator switches the ___________________ conductor, then the portable generator shall be grounded in accordance with NEC Article 250.30. 6. Service conductors shall be considered outside when run under the building if installed in conduit and buried ______________ under earth. 7. Under a raised floor in an Information Technology Equipment room, liquidtight flexible non-metallic conduit shall be permitted to enclose branch-circuit conductors for information technology communication equipment. True or False 8. A feeder for a motor circuit shall have a protective device with a rating or setting ________________ the largest rating of the branch-circuit short-circuit and ground-fault protective device for any motor in the group, plus the sum of the full load currents of the other motors of the group. 9. The purpose of 60/120V power systems is to reduce objectionable noise in areas containing sensitive electronic equipment. Its use is restricted to ________________ occupancies that are under close supervision by qualified personnel. 10. What is the feeder or service demand load for a kitchen/service area equipped with a waste disposal (940VA), dishwasher (1,250VA), water heater (4,500VA) and a trash compactor (1,100VA)? 11. The outer metal sheath of interlocked MC cable is not listed as an acceptable grounding return path; however, if the interlocked MC cable contains an insulated 12 AWG or larger equipment grounding conductor, it can be used to supply branch circuits in patient care areas of health care facilities. True or False 12. A branch circuit voltage that exceeds 277 volts to ground and does not exceed 600V between conductors is used to wire the auxiliary equipment of electrical discharge lamps mounted on poles. The minimum height of these luminaries shall not be less than __________. 13. When sizing a pull box in a straight run which contains conductors 4 AWG or larger, the length of the pull box shall not be less than ____________times the diameter of the largest raceway for systems not over 600 volts nominal. 14. A 480V, three-phase service is fed by an overhead service drop. The service drop crosses the alleyway behind the building. What is the minimum clearance that must be maintained between the service drop and the alleyway ground? 15. Water heaters having a capacity of ___________ gallons or less shall have a branchcircuit rating not less than 125% of the nameplate rating of the water heater. 16. A single device consisting of multiple receptacles comprised of _____________ or more receptacles shall be computed at not less than 90 VA per receptacle. 17. Energized parts of service equipment shall be _______________________ so that they will not be exposed to accidental contact or they shall be guarded. 18. Round boxes shall not be used with any wiring connector when a locknut or bushing is connected to the side of the box. True or False 19. Dwelling unit or mobile home feeder conductors not over 400A can be sized according to 310.15(B)(6). True or False 20. The additional service disconnecting means for a fire pump must be installed in the same location and grouped together with the main service disconnect. 21. Motors shall be located so that adequate ____________ is provided and so that maintenance, such as lubrication of bearings and replacing of brushes, can be readily accomplished. 22. The minimum point of attachment of the service-drop conductors to a building shall in no case be less than _________________. 23. No overcurrent device shall be inserted in a(n) _________________ conductor except a circuit breaker that simultaneously opens all conductors of the circuit in service equipment. 24. The ampacity of branch-circuit conductors and the rating or setting of overcurrent protective devices supplying fixed electric heating equipment for pipelines and vessels shall not be less than __________________ percent of the total load of the heaters. 25. Wherever NM cable passes through factory or field openings in metal members, it must be protected by ________________________ bushings or grommets that cover the metal edges. 26. Fixture wires 18 AWG TFFN are rated for ________________. 27. The requirement for maintaining a three-foot vertical clearance from the edge of the roof shall not apply to the final conductor span where the conductors are attached to ________________. 28. Ground fault protection is required for solidly grounded wye electrical services for more than ___________ volts to ground but not exceeding ___________ volts phase-tophase for each disconnect rated 1000 amperes or more. 29. An electrician determining the box fill for a two-gang plastic nail on box that is 2 1/8" deep will use the cubic inch volume of a four square deep box for the purposes of box fill determination. 30. IGS cable is a factory assembly of one or more conductors, each individually insulated and enclosed in a loose-fit, nonmetallic flexible conduit as an integrated gas spacer cable rated ____________________ volts. 31. The 125V, battery back-up smoke detector circuit for the bedroom of a single family dwelling shall be protected by an AFCI. True or False 32. Transformers of more than ______________ rating shall be installed in a transformer room of fire-resistant construction. 33. Plaster, drywall, or plasterboard surfaces that are broken or incomplete shall be repaired so there will be no gaps or open spaces greater than ___________ mm at the edge of a box or fitting. 34. ______________ is a type of multi-conductor cable permitted for use as an underground service-entrance cable. 35. What is the minimum demand load for five 5 kW cook tops, two 4 kW ovens and four 7 kW ranges? 36. Fixed electric space-heating equipment requiring supply conductors with an insulation rated over ________ shall be clearly and permanently marked. 37. On fixed stage equipment, portable or strip luminaries and connector strips shall be wired with conductors having an insulation rating suitable for the temperature but not less than __________________. 38. What is the demand on the feeder neutral of an apartment complex of ten, 5 kW household dryers? The apartment complex has a 240 V, single-phase service. 39. A fuel cell system shall be evaluated and __________________ for its intended application prior to installation. 40. A hermetic motor-compressor controller shall have both a continuous-duty full load current and a _______________ current rating not less than the respective rating(s) on the compressor. 41. Can type MC cable be used to feed a luminaire rated over 600 Volts that is installed in a highway tunnel? 42. The minimum sized service-drop conductor permitted by the Code is ________________ AWG copper or ______________ AWG aluminum or copper clad aluminum. 43. The outer sheath of MI cable is made of _________________. 44. Service conductors that are not encased in concrete and buried 18" or more below grade shall have their location identified by a warning ribbon placed in the trench at least ________________ above the underground installation. 45. THHN circuit conductors that operate at 277V may not occupy the same enclosure or raceway containing conductors that operate at 48V dc that have a 300V insulation rating. True or False 46. The patient care area is any portion of a health care facility, including the business offices, corridors, lounges, day rooms, dining rooms or similar areas. True or False 47. A luminaire may be wall-mounted on a standard box providing it is no larger than 16" in diameter. True or False 48. An intentionally constructed, permanent, low-impedance electrically conductive path designed and intended to carry current under-fault conditions from the point of a ground fault on a wiring system to the electrical supply source is a definition of: 49. What is the maximum time period that decorative lighting used for Halloween may be installed and used? 50. In non-residential use, what is the maximum overcurrent protection for 2 AWG RHW aluminum conductors with an ambient temperature of 88 degrees F? 51. The minimum clearance from storage space to the outside edge of a recessed, uncovered, fluorescent fixture in a closet is _______________________. 52. Motors with 50- and 60-Hz ratings shall be marked with a ___________________ designating the locked rotor kilovolt-ampere per horsepower on 60 Hz. 53. When installing multi-conductor cables in EMT, the fill capacity shall not exceed the allowable percentage of fill specified in ____________. 54. In general, the neutral of a solidly grounded neutral system shall be permitted to be grounded at more than one point. True or False 55. What is the total cooking equipment demand on the main service entrance for a single-family dwelling that is equipped with a single 2.1kW cooktop and one 4.9kW wall-mounted oven and one 4.8kW wall-mounted oven? 56. A single family dwelling must have at least ________________ 20 ampere branch circuits. 57. An unattended self-service gasoline station is required to have two emergency disconnects, what is the maximum distance from the dispenser that one of the disconnects may be located. 58. What is the recommended sized overload for a 10hp, single-phase AC motor operating on a 208V circuit? The nameplate rating of the motor is 51.6 amps. The motor has a marked service factor of 1.15. 59. What is the net computed load for a dwelling unit that is 200 square meters and has one kitchen? 60. Which of the following functions shall not be connected to the life safety branch circuits in a hospital: 61. A molded case switch rated in amperes shall be permitted as a controller for all motors, including design _______. 62. What is the total cooking equipment demand on the main service entrance for an apartment complex that has 55 units? Each apartment is equipped with a 3.1kW cooktop and two 3.55kW wall mounted ovens. 63. Exposed vertical risers from fixed equipment in other than dwelling units shall be permitted to be supported at intervals not exceeding _______ meters, if the conduit is made up of threaded couplings, the conduit is firmly supported at the top and bottom of the riser, an no other means of intermediate support is readily available. 64. The radius of a bend made in liquidtight flexible metal conduit shall be measured to the ______________ conduit. 65. In general, when installing a motor in one location and the motor controller in another location that are not within sight of each other, the minimum number of disconnecting means means required is _____________. 66. A ballast in a fluorescent exit luminaire fixture ___________ be required to be thermally protected. 67. A snap switch is located within reach of earth ground and is not grounded with an equipment-grounding conductor and no means of grounding exists within the snap switch enclosure. In this situation, the snap switch must be equipped with a __________________. 68. What is the minimum size type SO cord required to feed a 40 hp, 460 volt, threephase, AC, wound rotor motor in an ambient temperature of 86 degrees F? 69. Heavy duty lighting track is lighting track identified for use exceeding ____________ amperes. 70. What is the minimum cooking equipment demand on the service entrance for a range that is rated at 16.9 kW? 71. A power panelboard is one having __________ percent or fewer of its overcurrent devices protecting lighting and appliance branch circuits. 72. A panelboard equipped with a snap switches rated 20 amperes, 30 amperes and 40 amperes has an overcurrent protection in the form of a 250 ampere main breaker. Is this installation legal? 73. What is the minimum required size copper equipment grounding conductor for a 15 ampere branch circuit installed in rigid metal conduit that supplies a swimming pool motor? 74. At least one entrance not less than 24 inches wide and 6.5 feet high shall be provided to give access to the working space about the electric equipment. Where the entrance has personnel doors, the doors shall: 75. What is the minimum size common grounding electrode copper conductor needed to run through a building to four , 480V to 208/120V, three-phase transformers? Each transformer has a 3/0 AWG copper secondary phase conductor. 76. What is the maximum-sized over-current device which can be used to protect the feeders for a circuit that supplies three 50 ampere at 30 duty cycle arc welders and four variable-duty, automatically fed, 100 ampere resistance welders? All of the welders are rated at 75 degrees C, and THHN conductors will be used. 77. 12 AWG, THHN conductors installed in EMT which passes over a ceiling that is heated with electric space heating cable and having a clearance of 3 inches shall have their ampacity reduced to _____________. 78. The emergency controls for attended self-service stations shall be located no more than ___________ from the gasoline dispensers. 79. The purpose of the equipotential plane is to prevent a difference in voltage within the plane in an agricultural building area. True or False 80. It permissible to supply a mobile home that is factory-equipped with gas or oil-fired central heating equipment and cooking appliances with a listed mobile home powersupply cord rated ________. 81. The ampacity requirements for a disconnecting means for x-ray equipment shall be based on the greater of _______ percent of the input required for the momentary rating or 100 percent of the input required for the long-time rating. 82. A center pivot irrigation machine may have hand-portable motors. True or False 83. What is the minimum size copper equipment grounding conductor required for a 400 ampere branch circuit? The ungrounded conductors are sized using an adjusted value from the 90 C column of T310.16. The ungrounded conductors were then up-sized from 500 kcmil to 750 kcmil. 84. The voltage at the line terminals of a fire-pump motor controller (controller rated voltage) shall not drop more than _____________ percent below normal (controller-rated voltage) under motor-starting conditions. 85. What is the maximum-sized separate overload device that can be used to protect a 480V, 20 hp, three-phase induction motor? The motor has a nameplate full-load current of 22.8A and a marked service factor of 1.12. Assume the motor will experience no problems with start-up after the overloads are installed. 86. In general, an equipment bonding jumper installed on the outside of a raceway may not exceed: 87. The grounding conductor for a coaxial cable protector shall be: 88. When a portable generator is used for a portable optional standby source and is not considered a separately derived system, what shall the equipment-grounding conductor be bonded to? 89. Service entrance conductors shall be considered outside the building if they are installed in conduit and covered with at least _______ mm of earth. 90. Automatically operated doors used for building egress in a hospital shall be supplied from the ___________________. 91. What is the minimum size equipment ground for a 5 hp, 3 phase 208 V motor with 20 ampere overload protection and 30 ampere duel element time delay fuse short circuit protection? 92. How many grounded conductors may terminate in the same lug in a panelboard if the grounded conductors are not a part of a parallel run. 93. What is the ampacity rating of each copper conductor when installing five 10/2 with ground MC cables bundled together for a length of four feet? The equipment in the circuit is rated at 90 degrees Centigrade. 94. What is the maximum size overcurrent device required to protect 14 AWG conductors used for a pump motor circuit that is protected by the motor branch-circuit protection? The circuit extends beyond the enclosure. 95. What is the maximum size solid ungrounded conductor that may be installed in a raceway? 96. A three-phase 480V to 208/120V transformer is configured delta-wye. The secondary line current on the transformer is 178.6 amperes. What is the secondary phase current? 97. A three-phase 480V to 208/120V transformer is configured delta-wye. The secondary line current on the transformer is 56.9 amperes. What is the primary line current? 98. A circuit that has a total resistance of 57 ohms and a current of 9 amps will produce a power of __________________ watts. 99. What is the line to line voltage drop on 480 volt three-phase ac system? The circuit conductors are 3/0 copper and are installed underground in schedule 80 rigid nonmetallic conduit. The circuit length is 116 meters one direction. The circuit has a full load current of 116.9 amperes. 100. A resistance reading is taken between two 18 AWG solid copper conductors. A fault exists between the two wires somewhere in a 200 foot conduit run. The reading is 1.2276 ohms. Approximately how far down the conduit is the fault located? © 2001 Ted “Smitty” Smith