* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download 205_ch2 - BRE Projects
Building regulations in the United Kingdom wikipedia , lookup
Sustainable architecture wikipedia , lookup
Earth sheltering wikipedia , lookup
Thermal comfort wikipedia , lookup
Sustainable landscaping wikipedia , lookup
Green building wikipedia , lookup
Indoor air pollution in developing nations wikipedia , lookup
Passive house wikipedia , lookup
Ventilation (architecture) wikipedia , lookup
The EWZ building The EWZ building Presentation of the building The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent Project presentation (1...) The EWZ building Presentation of the building The EWZ building was completed in 1994. The building is situated in the northern part of Zurich in an urban area. It is a five storey triangular shaped building, with two sides facing busy roads in a congested urban area. It is designed to protect the occupants from noise and air pollution. Major findings More information... The façades provide a noise barrier and four atria are included (two on the north-side and two on the south-side) to provide maximum daylighting and natural ventilation. Back to “Select a building” Thanks to its massive construction the building has a high thermal mass The design issue The building concept The winter monitoring The summer monitoring NatVent Project presentation (2...) The EWZ building Presentation of the building The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent It is a five storey triangular shaped building, with two sides facing busy roads in a congested urban area. Project presentation (3|) The EWZ building Presentation of the building The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent Naturally ventilated offices Mechanically ventilated offices Mechanically ventilated atria The design issue (1...) The EWZ building Presentation of the building A two step hybrid ventilation concept was chosen to meet energy and comfort demands: The four atria are mechanically ventilated during the day, but provide manual window access to the surrounding offices which are naturally ventilated. At night time the atria and the offices are naturally ventilated. Decentralised ventilation units are used to reduce ductwork and energy use. The main target of this project was to design an energy efficient multi-use building, both in construction and in use. After completion of the building, the aim is to achieve further energy savings during operation together with good indoor environment. The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent The design issue (2|) The EWZ building Presentation of the building The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent The building concept (1...) ventilation strategy during summer The EWZ building Presentation of the building … for the Atria: During working hours: Mechanical ventilation with heat recovery and central cooling. At night: Natural ventilation by window opening in the atria. The summer monitoring Major findings More information... Back to “Select a building” NatVent Offices The winter monitoring Atria The building concept Offices The design issue … for the Offices : Natural ventilation by manual opening the windows facing the atria. The building concept (2...) low energy use in winter time The EWZ building Presentation of the building Fresh Air The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent The mechanical ventilation system is equipped with a central heat recovery unit to reduce the energy losses during the heating season. Moreover, the ventilation is turned off outside office hours Exhaust Air Heat Recovery Unit Supply Air The building concept (3...) overall strategy for summer comfort The EWZ building Presentation of the building Ice stack is loaded during the night to cool during the day. The atria are then ventilated, with a projected air exchange rate of 5 h-1 (pre-cooled air at 16 to 17°C). To properly mix the air in the atria ventilators are installed. In addition night cooling is applied by automatically opening the top windows in the atria. To reduce solar impact there are motorised shading devices (external screens) on the side walls and atria roofs. There is no active cooling in the offices ! The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent (Schematic - see next slide…) The building concept (4...) overall strategy for summer comfort The EWZ building Presentation of the building Night Day The design issue The building concept The winter monitoring The summer monitoring Major findings More information... External screens Night Cooling Back to “Select a building” NatVent Ice stack load Mixing Fans Cooled Air (Outside air is pre-cooled by the Ice stack load: 16 to 17°C) The building concept (5|) The ventilation concept was chosen to meet comfort demands. Concept: The atria is mechanically ventilated and provides manual window access to the surrounding offices which are naturally ventilated. Control: The air change rate in the office is chosen by the users as they wish. The design issue The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent Atria The EWZ building Presentation of the building Offices indoor air quality during office hours Monitoring set-up The EWZ building Presentation of the building The design issue The building concept Continuous measurements of carbon dioxide (CO2 ) / ventilation rate / temperature / humidity / indoor air velocity (in the offices) were made over one week periods during February 1997, July 1997, in The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” . NatVent atrium 2 (right side of the south façade of the building) three cellular offices on the first, second fourth floor of the atrium 2 (fully monitored) atrium 1 (left side of the south façade of the building) three cellular offices on the first, second fourth floor of the atrium 2 (only temperature) The following offices were considered as representative: for winter: a cellular office on the second floor surrounding atrium 2 for summer: a cellular office on the first floor surrounding atrium 2 The monitoring results of these offices are shown in the following charts Winter monitoring (1...) typical winter day - monitoring results The EWZ building Presentation of the building The winter monitoring The summer monitoring Major findings More information... Slight overheating in offices due to problems with automatic control of the shading devices 1000 30 Back to “Select a building” NatVent 25 800 20 600 15 10 400 5 200 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 06 09 12 15 18 21 00 -5 0 07-09.02.1997 Indoor Temp.- office [°C] Air Change - office [1/h] Atrium Temp. [°C] Carbon Dioxide [ppm] Outside Temp. [°C] Carbon dioxide The building concept 1200 35 Indoor and outside temp air change rate The design issue 40 Winter monitoring (2...) typical winter day - monitoring results The EWZ building Presentation of the building The winter monitoring The summer monitoring Good IAQ: low CO2 concentration during office hours (far below 1200 ppm) 1000 30 Major findings More information... 25 800 20 600 15 10 400 5 200 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 06 09 12 15 18 21 00 -5 0 07-09.02.1997 Back to “Select a building” NatVent Indoor Temp.- office [°C] Air Change - office [1/h] Atrium Temp. [°C] Carbon Dioxide [ppm] Outside Temp. [°C] Carbon dioxide The building concept 1200 35 Indoor and outside temp air change rate The design issue 40 Winter monitoring (3|) typical winter day - monitoring results The EWZ building Presentation of the building The winter monitoring The summer monitoring Low air change rate is sufficient: good air quality 1000 30 Major findings More information... 25 800 20 600 15 10 400 5 200 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 06 09 12 15 18 21 00 -5 0 07-09.02.1997 Back to “Select a building” NatVent Indoor Temp.- office [°C] Air Change - office [1/h] Atrium Temp. [°C] Carbon Dioxide [ppm] Outside Temp. [°C] Carbon dioxide The building concept 1200 35 Indoor and outside temp air change rate The design issue 40 Summer monitoring (1...) typical summer day - monitoring results The EWZ building Presentation of the building 40 The design issue 30 The winter monitoring The summer monitoring Indoor and outside temp air change rate The building concept 35 Major findings More information... 25 20 15 Good thermal comfort in office: Tint = 23°C while Text goes to 33°C: Remark: This results is partially the result of active cooling in the atrium 10 5 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 06 09 12 15 18 21 00 23-25.07.1997 Back to “Select a building” NatVent Indoor Temp. [°C] Outside Temp. [°C] Atrium Temp. [°C] Summer monitoring (2...) typical summer day - monitoring results The EWZ building Presentation of the building The winter monitoring The summer monitoring Good IAQ: low CO2 concentration during office hours (far below 1200 ppm) 1000 30 Major findings More information... 25 800 20 600 15 10 400 5 200 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 -5 06 09 12 15 18 21 00 0 23-25.07.1997 Back to “Select a building” NatVent Indoor Temp.- office [°C] Air Change - office [1/h] Atrium Temp. [°C] Carbon Dioxide [ppm] Outside Temp. [°C] Carbon dioxide The building concept 1200 35 Indoor and outside temp air change rate The design issue 40 Summer monitoring (3|) typical summer day - monitoring results The building concept The winter monitoring The summer monitoring 1200 Air change rates are sufficient good IAQ 35 Major findings More information... 1000 However no ventilation during the night to cool the office: window is closed 30 Indoor and outside temp air change rate The design issue 40 25 800 20 600 15 10 400 5 200 0 12 15 18 21 00 03 06 09 12 15 18 21 00 03 -5 06 09 12 15 18 21 00 0 23-25.07.1997 Back to “Select a building” NatVent Indoor Temp.- office [°C] Air Change - office [1/h] Atrium Temp. [°C] Carbon Dioxide [ppm] Outside Temp. [°C] Carbon dioxide The EWZ building Presentation of the building Major findings (1...) The EWZ building Presentation of the building The design issue The building concept The winter monitoring Night Cooling of the atria: Thanks to the architecture the stack effect in the atria can be considered to provide a sufficiently strong force for natural ventilation; On the other hand a re-evaluation of the dimensions of the openings could increase night ventilation resulting in a better natural night cooling. Night Cooling of the offices - Barriers Night cooling in the atria only takes place if atria windows are open. The atria windows are in this case automatically open if outside temperature is three degrees lower than the air temperature in the atria (this a typical strategy for mechanical night cooling). For natural night cooling the atria windows should automatically open if outside temperature is lower than the air temperature in the atria Night cooling in the offices only takes place if the office windows have been left open after the end of the working days. Closed office windows and doors form a large obstruction for the natural night cooling. The best night cooling efficiency is achieved by cross ventilation through window and door. The summer monitoring Major findings More information... Back to “Select a building” NatVent Major findings (2...) The EWZ building Presentation of the building The design issue The building concept Shading devices: In the winter, the shading devices , which close automatically, did not close at the right time. Therefore offices are sometimes lightly overheated and illuminated with too much direct sun light. The automatically shading devices in summer achieved the expected aims. The thermal comfort in summertime is optimal (remark: in summer active cooling is used in the atria). The winter monitoring The summer monitoring Major findings More information... The Indoor Air Quality is always acceptable Occupant Reactions: Back to “Select a building” NatVent The occupants are very satisfied with the building.One of the main reasons is that they appreciate being able to open the windows. Major findings (3|) The EWZ building Presentation of the building In General: The design issue The EWZ building is a good example of a pragmatic approach. The hybrid concept combines active cooling and passive elements like night cooling and shading devices. The concept provides high quality indoor comfort at any external condition. The building concept The winter monitoring The summer monitoring Major findings More information... Back to “Select a building” NatVent Energy consumption: The EWZ building can be considered as a building with a rather low energy consumption. A further reduction of the energy consumption can be achieved by an optimisation of the heating level in winter and the electricity consumption for the cooling and for the mechanical ventilation. More information... The EWZ building Presentation of the building The design issue The building concept The winter monitoring The summer monitoring Find more information on the PROBE building in the following documents: \Reports \Monitoring Reports \Summary Reports\ch2summ.pdf global presentation of the buildings (4p./building) contents: building description - ventilation strategy and technology winter and summer monitoring results - conclusions \Reports \Monitoring Reports \Detailed Reports\ch2det.pdf detailed reports of all 19 monitoring campaigns (20p./campaign) contents: monitoring set up - analysis of results - conclusions Major findings More information... Back to “Select a building” NatVent You can read and print pdf-files with the Acrobat® Reader ®3.0. Program. This program is free. Download it from the Acrobat web site: www.adobe.com OR run the installation file ar32e301(1).exe in the directory \Installation