Chapter 27 Zoning and Land Development
... *Editor’s note—Ordinance No. 2012-126, §§ 1, 2(Exh. A), adopted November 1, 2012, made comprehensive revisions to chapter 27 to read as herein set out. Formerly, said chapter pertained to zoning and derived from Ord. No. 90-203 adopted August 21, 1990. The absence of a history note indicates that th ...
... *Editor’s note—Ordinance No. 2012-126, §§ 1, 2(Exh. A), adopted November 1, 2012, made comprehensive revisions to chapter 27 to read as herein set out. Formerly, said chapter pertained to zoning and derived from Ord. No. 90-203 adopted August 21, 1990. The absence of a history note indicates that th ...
chapter 7. building - Town of Prescott Valley
... unsafe. An unsafe condition shall be deemed to have been created if an addition or alteration will cause the existing building or building service equipment to become structurally unsafe or overloaded; will not provide adequate egress in compliance with the provisions of the technical codes or will ...
... unsafe. An unsafe condition shall be deemed to have been created if an addition or alteration will cause the existing building or building service equipment to become structurally unsafe or overloaded; will not provide adequate egress in compliance with the provisions of the technical codes or will ...
nehrp commentary on the guidelines for the seismic rehabilitation of
... that are national in scope. By bringing together in the BSSC all of the needed expertise and all relevant public and private interests, it was believed that issues related to the seismic safety of the built environment could be resolved and jurisdictional problems overcome through authoritative guid ...
... that are national in scope. By bringing together in the BSSC all of the needed expertise and all relevant public and private interests, it was believed that issues related to the seismic safety of the built environment could be resolved and jurisdictional problems overcome through authoritative guid ...
extending the legacy
... Excited by the challenge of transitioning into a new role in GSA’s preservation program, I arrived at Central Office from our National Capital Region in 2009 to serve as the agency’s federal preservation officer. GSA’s sophisticated preservation program is grounded in what I shorthandedly refer to a ...
... Excited by the challenge of transitioning into a new role in GSA’s preservation program, I arrived at Central Office from our National Capital Region in 2009 to serve as the agency’s federal preservation officer. GSA’s sophisticated preservation program is grounded in what I shorthandedly refer to a ...
Chapter 1, Administration - Florida Building Commission
... 102.1.1 The Florida Building Code does not apply to, and no code enforcement action shall be brought with respect to, zoning requirements, land use requirements and owner specifications or programmatic requirements which do not pertain to and govern the design, construction, erection, alteration, mo ...
... 102.1.1 The Florida Building Code does not apply to, and no code enforcement action shall be brought with respect to, zoning requirements, land use requirements and owner specifications or programmatic requirements which do not pertain to and govern the design, construction, erection, alteration, mo ...
Open Access - Lund University Publications
... When all that was done I started with the analysis. First I discuss the total number of each type. Then I describe the spatial distribution of the buildings to see what patterns could be established. Possible explanations for said patterns are then discussed. The interregional differences in the tot ...
... When all that was done I started with the analysis. First I discuss the total number of each type. Then I describe the spatial distribution of the buildings to see what patterns could be established. Possible explanations for said patterns are then discussed. The interregional differences in the tot ...
Bloomfield Township Zoning Ordinance
... aspect of site design. In such instances, the specific regulations must be followed. Discrepancies between text and an illustration (including its caption) may occur. In the case of such discrepancies, the text is considered the accurate source of information. The use of the word shall carries signi ...
... aspect of site design. In such instances, the specific regulations must be followed. Discrepancies between text and an illustration (including its caption) may occur. In the case of such discrepancies, the text is considered the accurate source of information. The use of the word shall carries signi ...
Introduction to Earthquake Engineering and Seismic Codes
... Fig.1.11 shows acceleration time histories of the 30 seconds recorded in the 1978 Miyagikenoki Earthquake at a 9 story reinforced concrete building of Tohoku University, Sendai, Japan. The upper graph is the record of the 9th story and the lower is of the 1st story. Both are shown in the same scale ...
... Fig.1.11 shows acceleration time histories of the 30 seconds recorded in the 1978 Miyagikenoki Earthquake at a 9 story reinforced concrete building of Tohoku University, Sendai, Japan. The upper graph is the record of the 9th story and the lower is of the 1st story. Both are shown in the same scale ...
Building - Florida Building Code
... 104.9 Approved materials and equipment. (No change) 104.10 Modifications. Wherever there are practical difficulties involved in carrying out the provisions of this code, the building official shall have the authority to grant modifications for individual cases, upon application of the owner or owner ...
... 104.9 Approved materials and equipment. (No change) 104.10 Modifications. Wherever there are practical difficulties involved in carrying out the provisions of this code, the building official shall have the authority to grant modifications for individual cases, upon application of the owner or owner ...
F Facil lity D Desi ign G Guid delin nes
... incorporate ease and efficiency of operation and allow for easy and cost effective maintenance and repair. The Project A/E should obtain constant feedback from the Physical Plant Department during design. Detailed instructions from the Project A/E stating the design intent for all building systems a ...
... incorporate ease and efficiency of operation and allow for easy and cost effective maintenance and repair. The Project A/E should obtain constant feedback from the Physical Plant Department during design. Detailed instructions from the Project A/E stating the design intent for all building systems a ...
Flood-resilient waterfront development in New York City
... floodplains, as has been the case in the past, but also if there are changes in the frequency and intensity of the flood hazard due to changes in precipitation, storms, and sea-level rise. The availability of accurate and up-to-date FEMA flood hazard maps is important in steering appropriate waterfr ...
... floodplains, as has been the case in the past, but also if there are changes in the frequency and intensity of the flood hazard due to changes in precipitation, storms, and sea-level rise. The availability of accurate and up-to-date FEMA flood hazard maps is important in steering appropriate waterfr ...
Existing Building - Florida Building Code
... result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by legal repr ...
... result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by legal repr ...
Existing Building - Florida Building Code
... result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by legal repr ...
... result of any act or by reason of an act or omission in the discharge of official duties. Any suit instituted against an officer or employee because of an act performed by that officer or employee in the lawful discharge of duties and under the provisions of this code shall be defended by legal repr ...
Zoning Ordinance 00-04 - the Town of DISH, Texas!
... DISTRICT (ZONING) -- A section of the Town of Clark, Texas, for which the regulations governing the area, height, or use of the land and buildings are uniform. DRIVE-IN RESTAURANT OR REFRESHMENT STAND -- Any place or premises used for sale, dispensing, or serving of food, refreshments, or beverages ...
... DISTRICT (ZONING) -- A section of the Town of Clark, Texas, for which the regulations governing the area, height, or use of the land and buildings are uniform. DRIVE-IN RESTAURANT OR REFRESHMENT STAND -- Any place or premises used for sale, dispensing, or serving of food, refreshments, or beverages ...
2014 L.A. Amendment Building Code
... 91.1207.5. Local Modification. The governing body of any city or county or city and county may, by ordinance, adopt changes or modifications to the requirements of this section as set forth in Section 17922.7 of the Health and Safety Code. Sec. 23. A new Subsection 91 .1207.6 is added to the Los Ang ...
... 91.1207.5. Local Modification. The governing body of any city or county or city and county may, by ordinance, adopt changes or modifications to the requirements of this section as set forth in Section 17922.7 of the Health and Safety Code. Sec. 23. A new Subsection 91 .1207.6 is added to the Los Ang ...
Section 1 - New Zealand Society for Earthquake Engineering Inc.
... Assessment of the structural performance of e xisting buildings is a challenging task. Each building has unique charact eristics and it is often difficult to determine with confidence the extent and quality of structural components and materials. These NZSEE Recommendations provide authoritative and ...
... Assessment of the structural performance of e xisting buildings is a challenging task. Each building has unique charact eristics and it is often difficult to determine with confidence the extent and quality of structural components and materials. These NZSEE Recommendations provide authoritative and ...
title 15 - Marinette
... Any fence necessary at any school, public park or other public recreational facility to accommodate recreational activities shall be exempt from the maximum height requirements of this section. ...
... Any fence necessary at any school, public park or other public recreational facility to accommodate recreational activities shall be exempt from the maximum height requirements of this section. ...
Existing Building - Florida Building Code
... [A] 104.2.1.1 Building evaluation. The code official is authorized to require an existing building to be investigated and evaluated by a registered design professional based on the circumstances agreed upon at the preliminary meeting. The design professional shall notify the code official if any pot ...
... [A] 104.2.1.1 Building evaluation. The code official is authorized to require an existing building to be investigated and evaluated by a registered design professional based on the circumstances agreed upon at the preliminary meeting. The design professional shall notify the code official if any pot ...
Cross Laminated Timber
... comprised of two five-story wings—a laboratory wing made from conventional reinforced concrete and the North Wing, a new LEED Gold building with offices and lecture halls, which utilizes wood as the main structural element. The North Wing features an innovative combination of mass timber systems, in ...
... comprised of two five-story wings—a laboratory wing made from conventional reinforced concrete and the North Wing, a new LEED Gold building with offices and lecture halls, which utilizes wood as the main structural element. The North Wing features an innovative combination of mass timber systems, in ...
Vienna Township Zoning Ordinance
... B. To encourage the use of lands and resources of the Township in accordance with their character and adaptability. C. To provide economic progress and protect and enhance property values. D. To reduce hazards of life and property, promote safety in traffic and provide fire protection. E. To provide ...
... B. To encourage the use of lands and resources of the Township in accordance with their character and adaptability. C. To provide economic progress and protect and enhance property values. D. To reduce hazards of life and property, promote safety in traffic and provide fire protection. E. To provide ...
here - New Zealand Society for Earthquake Engineering Inc.
... Each building has unique characteristics and it is often difficult to determine with confidence the extent and quality of structural components and materials. These NZSEE Recommendations provide authoritative and timely information to assist TAs, owners and their engineers to make assessments of the ...
... Each building has unique characteristics and it is often difficult to determine with confidence the extent and quality of structural components and materials. These NZSEE Recommendations provide authoritative and timely information to assist TAs, owners and their engineers to make assessments of the ...
Verbeterde voorspellingen van het energiegebruik voor
... Data accuracy and completeness influencing statistical analyses on the prediction gap .................................................................................. 84 ...
... Data accuracy and completeness influencing statistical analyses on the prediction gap .................................................................................. 84 ...
CHAPTER 2 MEANS OF ESCAPE
... into the open external space at the ground level. From this point on they should no longer be in any danger from the fire or smoke in the building. Where an exit opens or discharges into an internal courtyard, a safe passageway must be readily available to lead the occupants out from this internal c ...
... into the open external space at the ground level. From this point on they should no longer be in any danger from the fire or smoke in the building. Where an exit opens or discharges into an internal courtyard, a safe passageway must be readily available to lead the occupants out from this internal c ...
Chapter 8 - BUILDING STANDARDS CODE [21]
... Front side. The side of the manufactured home or recreational vehicle where the front door is located or left side when facing the tongue or headlights. Garbage. Food waste. Good condition. Free from structural deficiencies and in compliance with the minimum standards of all applicable laws. Habitab ...
... Front side. The side of the manufactured home or recreational vehicle where the front door is located or left side when facing the tongue or headlights. Garbage. Food waste. Good condition. Free from structural deficiencies and in compliance with the minimum standards of all applicable laws. Habitab ...
Sector Briefing Draft - The Seismic Assessment of Existing Buildings
... Buildings (Chief Executive’s) Methodology to be developed under the provisions of the Building (Earthquake-prone Buildings) Amendment Act. It will also be endorsed by MBIE for use as guidance under section 175 of the Building Act to the extent that it assists practitioners and territorial authoritie ...
... Buildings (Chief Executive’s) Methodology to be developed under the provisions of the Building (Earthquake-prone Buildings) Amendment Act. It will also be endorsed by MBIE for use as guidance under section 175 of the Building Act to the extent that it assists practitioners and territorial authoritie ...