* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download NA Y.3 Connections to mains
Immunity-aware programming wikipedia , lookup
Stray voltage wikipedia , lookup
Power inverter wikipedia , lookup
Flexible electronics wikipedia , lookup
Audio power wikipedia , lookup
Standby power wikipedia , lookup
History of electric power transmission wikipedia , lookup
Electrification wikipedia , lookup
Electric power system wikipedia , lookup
Power over Ethernet wikipedia , lookup
Public address system wikipedia , lookup
Ground loop (electricity) wikipedia , lookup
Three-phase electric power wikipedia , lookup
Power engineering wikipedia , lookup
Skin effect wikipedia , lookup
Electromagnetic compatibility wikipedia , lookup
Aluminium-conductor steel-reinforced cable wikipedia , lookup
Voltage optimisation wikipedia , lookup
Switched-mode power supply wikipedia , lookup
Electrical substation wikipedia , lookup
Distribution management system wikipedia , lookup
Rectiverter wikipedia , lookup
Telecommunications engineering wikipedia , lookup
Alternating current wikipedia , lookup
Portable appliance testing wikipedia , lookup
Mains electricity wikipedia , lookup
Ground (electricity) wikipedia , lookup
May 19, 2010 Page 1 of 7 DRAFT Annex NA Y (normative) Equipment connected to d.c. power distribution systems (mains) This annex provides requirements for equipment connected to a dc power distribution system (mains). Applicability of these requirements is dependent on the construction of the equipment and its intended installation and use. NOTE 1 Underlining to indicate text added to IEC 62368-1 is not used in this annex. NA Y.1 General NA Y.2 Classification of circuits Y.2.1 Supply circuits NA Y.3 Connections to mains Y.3.1 General Y.3.2 Equipment connected to mains by non-detachable power supply cord or detachable power supply cord with appliance inlet Y.3.3 Permanently connected equipment Y.3.4 Protective earthing Y.3.5 Restricted access area NA Y.4 Equipment markings and instructional safeguards Y.4.1 Polarity Y.4.2 Equipment with the earthed conductor connected to the protective earthing conductor at the equipment: Y.4.3 Equipment with provision to connect the earthed conductor to protective earthing conductor at the equipment: May 19, 2010 Page 2 of 7 DRAFT Topic Annex NA Sub-topic Annex NA Y.1 General Requirement See 3.3.1.2 for definition of mains. A d.c. power distribution system (d.c. mains) is a power distribution system with or without batteries, external to the equipment, for supplying power to d.c. powered equipment. Note A d.c. power distribution system with storage batteries, often called a centralized d.c. power system, consists of open batteries, charger/rectifier circuits and primary and secondary distribution equipment that is intended to provide power to equipment loads. Systems rated not less than 48 V have one point directly earthed, the exposed conductive parts of the installation being connected to that point by protective earth conductors. Systems rated less than 48 V may have one point directly earthed. Two types of systems are recognized according to the arrangement of earthed and protective earth (earthing) conductors, as follows: - source earthed d.c. power systems, in which the connection to the earthing electrode is located at the source and separate earthed and protective earth conductors are provided throughout the system. See Figure NA Y.1. - d.c. power system earthed at the equipment location, in which the connection to the earthing electrode is located in the area where the load equipment is to be installed, typically known as the "earthing window." See Figure NA Y.2. Y.2 Classification of circuits Y.2.1 Supply circuits A circuit for connection to a d.c. power distribution circuit is classified as an ES1, ES2 or ES2 circuit depending on the maximum operating voltage of the supply. For d.c. power distribution systems derived from storage batteries, the maximum operating voltage shall include consideration of the battery charging “float voltage” associated with the intended supply system, regardless of the marked power rating of the equipment. Note Equipment marked –60 Vdc and connected to a d.c. power distribution system may have a maximum operating voltage up to –75 Vd.c. See IEC TR62102 (Table B.1), 48 V and 60 V ‘Station Battery’ examples. For purposes of applying insulation requirements per 5.4, circuits connected to a d.c. power distribution system are treated as indicated below: Maximum Operating voltage of d.c. power distribution circuit. [Classification of circuit connected to d.c. power distribution circuit up to 60 V d.c. ES1 > 60 V up to and including 120 V (???) ES2 > 120 V (???) ES3 Y.3 Connections to mains Y.3.1 General For safe and reliable connection to a d.c. power distribution system, equipment shall be provided with one of the following: - terminals for permanent connection to the supply; May 19, 2010 Page 3 of 7 DRAFT Topic Annex NA Sub-topic Annex NA Y.3.2 Equipment connected mains by nondetachable power supply cord or detachable power supply cord with appliance inlet Y.3.3. Permanently connected equipment Y.3.4 Protective earthing Requirement - a non-detachable power supply cord for connection to the mains supply by means of a plug; - an appliance inlet for connection of a detachable power supply cord. See G.9 for requirements for power supply cords. See G.20 for mains connectors. Plugs and appliance inlets shall not be of a type that is used for a.c. power distribution systems (mains) if a hazard could be created by their use. Plugs and appliance inlets shall be so designed that reverse polarity connections are prevented if a hazard could be created by such connection. See B.3.3. See Annex NA X for requirements for permanently connected equipment. See 5.6. Equipment intended to be connected to a nominal 48 V d.c. (or higher) power supply source, or systems rated less than 48 V d.c. that have one point directly earthed (grounded), shall have provision for the earthing (grounding) of all exposed dead metal parts that might become energized from the power supply source or from circuits involving a risk of electric shock. Equipment that has the earthed terminal (terminal for the grounded conductor) of the power source connected to the frame of the unit is required to have special provisions for earthing (grounding), along with markings and instructions. See Annex Y.4.2 and Y.4.3. If the equipment provides the means for connecting the supply to the earthing electrode conductor (grounding conductor or grounding electrode conductor), there shall be no switches or overcurrent protective devices located between the point of connection to the supply and the point of connection to the earthing (grounding) electrode. Y.3.5 Restricted access area For equipment intended to be installed in a restricted access area, it is permitted for one pole of the d.c. power distribution system to be connected both to an equipment mains input terminal and to the main protective earthing terminal of the equipment, if any, provided all of the following conditions are met: - the equipment is intended to connect directly to the point of earthing of the d.c. system; - bus bars, bonding jumpers and terminals are provided for the connection of the equipment earthing conductors and the earthing electrode conductor, by permanent wiring methods, to one of the d.c. supply conductors. Such hardware shall be constructed and sized in accordance with the Standard for Switchboards, UL 891, and Switchgear Assemblies, CSA C22.2 No. 31; - the d.c. supply conductor may be earthed in more than one piece of equipment if all the equipment is located in the same immediate area as the point of earthing of the d.c. system (that is, within the "earthing window"); - means are provided for connection of the equipment to the d.c. source by permanent wiring methods, and no disconnecting device is located in the earthed d.c. circuit conductor between the point of connection to the supply and the point of connection to the earthing May 19, 2010 Page 4 of 7 DRAFT Topic Annex NA Sub-topic Annex NA Requirement electrode and equipment earthing conductors; - the equipment is marked with instructions or a reference to instructions for proper earthing and bonding of the system and equipment. The marking shall be permanent and located near and in plain view of the field wiring terminals and worded as indicated in NA Y_ for equipment that either: a) has provisions to connect the earthed conductor of a d.c. supply circuit to the earthing conductor at the equipment or b) has the earthed conductor of a d.c. supply circuit connected to the earthing conductor at the equipment; and - installation instructions are provided for field assembly of earthing and bonding conductors where the connections are not conventional. Compliance is checked by inspection. Y.4 Equipment markings and instructional safeguards Y.4.1 Polarity For permanently connected equipment, terminals intended exclusively for connection to a d.c. power distribution circuit shall be marked to indicate polarity. If a single terminal is provided, both as a main protective earthing terminal in the equipment and for the connection to one pole of the d.c. power distribution circuit it shall be marked as specified in X.5.2, in addition to polarity marking. Y.4.2 Equipment with the earthed conductor connected to the protective earthing conductor at the equipment: Y.4.3 These indications shall not be located on screws or other parts which might be removed when conductors are being connected. Compliance is checked by inspection. Equipment that has the earthed conductor of a d.c. power distribution system connected to the earthing conductor at the equipment shall be provided with a permanent marking located near and in plain view of the field wiring terminals and worded as indicated. Example wording of marking: CAUTION: This equipment has a connection between the earthed conductor of the d.c. supply circuit and the earthing conductor. See installation instructions. Alternatively, the wording can be replaced by the symbol on the product if the specified wording appears in the installation instructions. Example wording of installation instructions: “This equipment has a connection between the earthed conductor of the d.c. supply circuit and the earthing conductor. All of the following installation conditions must be met: This equipment shall be connected directly to the d.c. supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the d.c. supply system earthing electrode conductor is connected. This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same d.c. supply circuit and the earthing conductor, and also the point of earthing of the d.c. system. The d.c. system shall not be earthed elsewhere. The d.c. supply source shall be located within the same premises as this equipment. - Switching or disconnecting devices shall not be in the earthed circuit conductor between the d.c. source and the point of the connection of the earthing electrode conductor.” Compliance is checked by inspection. Equipment that has provision to connect the earthed conductor of a d.c. power distribution system to the earthing conductor at the equipment May 19, 2010 Page 5 of 7 DRAFT Topic Annex NA Sub-topic Annex NA Equipment with provision to connect the earthed conductor to protective earthing conductor at the equipment: Requirement shall be provided with a permanent marking located near and in plain view of the field wiring terminals and worded as indicated. Example wording of marking: CAUTION: This equipment is designed to permit the connection of the earthed conductor of the d.c. supply circuit to the earthing conductor at the equipment. See installation instructions. Alternatively, the wording can be replaced by the symbol on the product if the specified wording appears in the installation instructions. Example wording of installation instructions: “This equipment is designed to permit the connection of the earthed conductor of the d.c. supply circuit to the earthing conductor at the equipment. If this connection is made, all of the following conditions must be met: This equipment shall be connected directly to the d.c. supply system earthing electrode conductor or to a bonding jumper from an earthing terminal bar or bus to which the d.c. supply system earthing electrode conductor is connected. This equipment shall be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a connection between the earthed conductor of the same d.c. supply circuit and the earthing conductor, and also the point of earthing of the d.c. system. The d.c. system shall not be earthed elsewhere. The d.c. supply source shall be located within the same premises as this equipment. Switching or disconnecting devices shall not be in the earthed circuit conductor between the d.c. source and the point of connection of the earthing electrode conductor.” Compliance is checked by inspection. May 19, 2010 Page 6 of 7 DRAFT For the purpose of applying this figure, grounded and grounding are equivalent to earthed and earthing, respectively. Figure NA Y.1 – Typical d.c. power distribution system - plant and distribution source-grounded d.c. power system May 19, 2010 Page 7 of 7 DRAFT For the purpose of applying this figure, grounded and grounding are equivalent to earthed and earthing, respectively. Figure NA Y.2 - Typicald d.c. power disribution system - plant and distribution d.c. power system grounded at the equipment location