Download PANDA - Particles And Non-Destructive Analysis

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Antiproton Decelerator wikipedia , lookup

Quantum entanglement wikipedia , lookup

Faster-than-light neutrino anomaly wikipedia , lookup

Electron scattering wikipedia , lookup

Data analysis wikipedia , lookup

Relational approach to quantum physics wikipedia , lookup

Elementary particle wikipedia , lookup

Identical particles wikipedia , lookup

Weakly-interacting massive particles wikipedia , lookup

ALICE experiment wikipedia , lookup

Measurement in quantum mechanics wikipedia , lookup

Super-Kamiokande wikipedia , lookup

ATLAS experiment wikipedia , lookup

Compact Muon Solenoid wikipedia , lookup

Transcript
Novel tools for sample analysis
PANDA – Particles And
Non-Destructive Analysis
PANDA is a sensitive measurement device for non-destructive sample analysis. In PANDA many
techniques and instruments used in basic research are applied to the analysis of environmental
and safeguards samples. Besides being a fully operational measurement device PANDA is also
a platform for the development of new techniques and measurement tools.
Features
Sensitive sample analysis using
non-destructive analysis techniques
Particle localization
Pu isotope ratio determination
Technical characteristics
Two measurement positions
operating inside a vacuum chamber
Separate vacuum chamber for loading
and chancing samples
Measurement position 1 hosts
a position sensitive double sided
silicon strip detector (DSSSD) for
the detection of alpha particles
and an HPGe detector for gammaand X-rays
Fig. 1. Photograph of the PANDA device.
Possibility to make coincidence
studies (α-γ, γ-α etc.)
Event-mode data acquisition
Data stored in LINSSI database
SPANDA software for data processing
Measurement position 2 hosts
a prototype silicon drift detector
that is currently being tested
Data collected with VASIKKA and
stored in LINSSI database
1
2
A
C
B
1 Loading chamber
2 Measurement chamber
A DSSSD
B HPGe detector
C Linear feedthrough
and sample holder
Fig. 2. CAD drawing of the inside of PANDA’s loading and measurement chambers.
Säteilyturvakeskus
Säteilyturvakeskus
Strålsäkerhetscentralen
Strålsäkerhetscentralen
Radiation
Radiationand
andNuclear
NuclearSafety
SafetyAuthority
Authority
Address
Address• •Laippatie
Laippatie4,4,P.O.
P.O.Box
Box14,
14,FI-00881
FI-00881Helsinki,
Helsinki,FINLAND
FINLAND••www.stuk.fi
www.stuk.fi
Novel tools for sample analysis
Applications
Locating particles
PANDA’s position sensitive alpha detector can be used
to detect particles from large-area samples such as
swipes or filters and perform a preliminary particle
analysis for them (Fig. 3).
Time stamped event data
PANDA’s data are collected in event-mode. Events are
time stamped. This storage format allows the
generation of final spectra for the analysis even after
the measurement. The event time stamping enables
various time behavior studies (Fig. 5).
1000
214
Po
Po
Counts/700 s
212
100
10
1
0
10000
20000
30000
40000
50000
60000
70000
Time (s)
Fig. 3. Hitmap measured with the DSSSD. The locations of the fitted
particles are marked as red asterisks.
Fig. 5. Time behavior of 212Po and 214Po alpha particle counts in
a sample measured with the DSSSD detector.
Coincidence gating (α-γ, γ-α etc.)
PANDA’s DSSSD and HPGe detectors can be used to
make various coincidence studies. For example an
alpha-gated gamma spectrum can have nearly zero
background. This greatly improves the detection of
239,240
Pu (Fig. 4).
many hard-to-detect nuclides such as
Conversion electron spectroscopy
The samples can be transported between PANDA’s two
measurement positions. If a sample screening in
measurement position 1 reveals an interesting particle
the measurements can be continued in measurement
3
position 2. The prototype silicon drift detector (SD ) in
PANDA’s measurement position 2 can also be used for
the detection of conversion electrons (Fig. 6).
59.5 K
239Pu
X+26
239Pu
241Am
X+26
59.5 K
X+26
240Pu
Fig. 4. Part of a fitted alpha-gated gamma spectrum of a particle
sample originating from a nuclear bomb and containing 239,240Pu and
241
Am.
Fig. 6. The silicon drift detector in PANDA’s measurement position 2.
Further reading
Turunen J, Peräjärvi K, Pöllänen R, Toivonen H. PANDA – A novel instrument for non-destructive sample analysis. Nuclear Instruments and
Methods in Physics Research A 2010; 613: 177–183.
Turunen J, Ihantola S, Peräjärvi K, Pöllänen R, Toivonen H. Novel spectrometric approach to non-destructive characterization of safeguards
samples. ESARDA Bulletin 45, December 2010. p. 23–28.
Peräjärvi KA, Ihantola S, Pöllänen RC, Toivonen HI, Turunen JA. Determination of 235U, 239Pu, 240Pu, and 241Am in a nuclear bomb particle
using a position-sensitive α-γ coincidence technique. Environmental Science and Technology 2011; 45 (4): 1528–1533.
Turunen J, Ihantola S, Peräjärvi K, Toivonen H. Comprehensive radioassays of samples using the PANDA device. Nuclear Instruments and
Methods in Physics Research A 2012; 678: 78–82.
Technology Readiness Level 5
STUK-TTL-FLYER-2011-009, 17 Oct 2012
Further information: Kari Peräjärvi, Jani Turunen and Harri Toivonen
Tel. +358 9 759881, e-mail: [email protected]