* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Measurement of lifetime for muons captured inside nuclei
Technicolor (physics) wikipedia , lookup
Future Circular Collider wikipedia , lookup
Weakly-interacting massive particles wikipedia , lookup
Neutrino oscillation wikipedia , lookup
Data analysis wikipedia , lookup
Electron scattering wikipedia , lookup
Strangeness production wikipedia , lookup
Grand Unified Theory wikipedia , lookup
Bruno Pontecorvo wikipedia , lookup
Elementary particle wikipedia , lookup
Double-slit experiment wikipedia , lookup
Faster-than-light neutrino anomaly wikipedia , lookup
Mathematical formulation of the Standard Model wikipedia , lookup
ALICE experiment wikipedia , lookup
Standard Model wikipedia , lookup
ATLAS experiment wikipedia , lookup
Measurement of lifetime for muons captured inside nuclei Advisors: Tsung-Lung Li Wen-Chen Chang Student: Shiuan-Hal Shiu 2007/06/27 Content Introduction Experimental Apparatus Analysis and Discussions Conclusion Introduction Flow Chart Physics motivation Physics events Detectors Electronic devices DAQ Data analysis Physics Results Standard Model 6 quarks. 6 leptons. Force carrier particles. The Four Interactions Force carrier Action object Graviton Photon Gluon Electroweak interaction Everything Charge Quarks, particles Gluons W,Z boson Quarks, Leptons Muon Muons were observed by Carl D. Anderson in 1936. Muons are denoted by μ− and antimuons by μ+. About 207 times mass as electron. (105.65Mev) Muon mean lifetime : 2.197μsec Muon have 1 negative electric charge. Muon is a fermion with ½ spin. Muon Decay Muon mean lifetime : 2.197μsec Muon and antimuon decay: Lepton Type Conservation Leptons are divided into three lepton families: 1. electron and electron neutrino 2. muon and muon neutrino 3. tau and tau neutrino Fermi Coupling Constant GF The muon decay is purely leptonic. Its directly related to the strength of the weak interaction. Fermi coupling constant GF is a measurement of the strength of the weak force. The relationship between the muon lifetime τfree and fermi coupling constant GF : free 192 2 5 4 GF m c 3 7 The new world average of muon lifetime is:2.197019μsec. The new GF is:1.166371*10-5 GeV2 . Muon Source The muon is produced in the upper atmosphere by the decay of pions produced by cosmic rays The flux of sea-level muons is approximately 1 per minute per cm2 The muon production height in the atmosphere is approximately 15km. If the muon traveling at the speed of light its still need 50μsec. Muon Decay Time Distribution Muon decay is a typical process of radioactive decay. N (t ) N 0 e t dN (t ) N (t )dt Random process N (t ) N 0 e t We call the muon lifetime is 1 Muon Capture Muon capture is the capture of a negative muon by a proton. Ordinary muon capture (OMC): p n Radiative muon capture (RMC): p n In the past, one motivation for the study of muon capture on the proton is its connection to the proton's induced pseudoscalar form factor gP. Muon capture Process Capture process 1. Muon enter the matter 2. Electromagnetic interactions 3. Muonic atom formed 4. μ+p→n+ν μ nucleus μ Matter Captured by nuclei: μ+p→n+ν only occur with negative charged muon In the order of nano-sec e Muon Capture Time Distribution N (t ) N 0 e t y C freee y C freee t free C pedistal t free C pedistal Ccapturee t ca pture Previous Result Experiment Flow Chart Experimental apparatus Detector Physics 1. Charged particle passing 2. Slow down μ μ 3. Stop e 4. Decay Scintillation detector PMT Measuring Muon Lifetime μ e Scintillation detector PMT Detector start: P1P2P3 μ stop: P3 PMT3 TARGET Free decay Free decay Capture decay Capture decay μ μ Pass through μ PMT1 n e p PMT2 n e p Electronic Device Block Diagram Gate condition Calibration of Experiment Apparatus Calibrate the PMT working voltage : Plateau measurement Calibration of Experiment Apparatus Calibration of Experiment Apparatus Calibration of Experiment Apparatus Calibrate the PMT working voltage : Coincidence plateau measurement Calibration of Experiment Apparatus Calibration of Experiment Apparatus Calibrate the efficiency of data acquisition system Data analysis TDC Data Analysis In this experiment we use the TDC to save the pulse's timing information and try to fit the lifetime for free decay and capture decay. TDC Data Analysis Procedure y C1e x free C 2 C3 e x capture The start point of background fitting The end point of background fitting Background (change end point) The 50ns/bin figure have a comparative little value with other figure. Cu (change end point) The results are all less than world average. The 50ns/bin figure have a comparative little value with other figure. Fe (change end point) Al (change end point) Change start point The start point of background fitting Background (change start point) The 50ns/bin figure still have a comparative little value with other figure. Cu (change start point) The first serveral points are less than world average. We select the 800ns to be the start point. Fe (change start point) Fe data are all too less. We choose the 1000ns to be the start point. Al (change start point) We choose the 1500ns to be the start point. Background Fitting Result Background do not have any target the capture lifetime may come from the scintillation detector atom. Cu Fitting Result Fe Fitting Result Al Fitting Result ADC Data Analysis Procedure In this experiment we want to use the ADC to save the pulse's charge information and try to differentiate the free decay events and capture decay events by the information from ADC. 1. Analyze the ADC VS. TDC profile. 2. Comparing the probability of compatibility between two ADC distribution. 3. Making different ADC cut and analyze the TDC data for each ADC cut. ADC VS. TDC Profile (TDC>10000) ADC VS. TDC Profile (TDC>1000) From the figures we can find there are no obvious evidence to differentiate the capture events Probability of Compatibility between two ADC Histogram (TDC<1000) Thistest is a statistical test of compatibility in shape between two histograms. The background ADC shape is the comparing base line Probability of Compatibility between two ADC Histogram (TDC>1000) Conclusion Conclusion The TDC analysis result is listed on the table TDC Analysis with Different ADC Cut All cut in 800