Download Simplify NFPA 70E /CSA Z462 Code Compliance

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Pulse-width modulation wikipedia , lookup

Power engineering wikipedia , lookup

Electrification wikipedia , lookup

Telecommunications engineering wikipedia , lookup

History of electric power transmission wikipedia , lookup

Electrical engineering wikipedia , lookup

Brushless DC electric motor wikipedia , lookup

Alternating current wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Electric motor wikipedia , lookup

Ground (electricity) wikipedia , lookup

Electromagnetic compatibility wikipedia , lookup

Buck converter wikipedia , lookup

Stray voltage wikipedia , lookup

Rectiverter wikipedia , lookup

AC motor wikipedia , lookup

Electrical substation wikipedia , lookup

Metadyne wikipedia , lookup

Voltage optimisation wikipedia , lookup

Electrician wikipedia , lookup

Crossbar switch wikipedia , lookup

Induction motor wikipedia , lookup

Portable appliance testing wikipedia , lookup

Brushed DC electric motor wikipedia , lookup

Switch wikipedia , lookup

Light switch wikipedia , lookup

Mains electricity wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Stepper motor wikipedia , lookup

Electrical wiring in the United Kingdom wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Industrial and multiphase power plugs and sockets wikipedia , lookup

National Electrical Code wikipedia , lookup

Transcript
Decontactors Simplify
Code Compliance
Decontactor Series switch rated plugs and receptacles
allow qualified workers to change-out a motor or other
electrical equipment without needing...
Flash Hazard Analysis
as required in NFPA 70E and CSA Z462
Arc Flash Boundaries
as required in NFPA 70E and CSA Z462
Voltage Testing
as required in NFPA 70E and CSA Z462
Cumbersome PPE
as required in NFPA 70E and CSA Z462
Auxiliary Disconnect Switches
as required in NEC 430.102 and CEC
Simplify NFPA 70E/CSA Z462
Code Compliance with...
Mechanical Interlocks
Presented by Meltric and:
800.433.7642
meltric.com
NFPA E
4640 Ironwood Drive
Franklin, WI 53132
as required for use with non-hp rated
plugs and receptacles
Meltric
DECONTACTOR TM Series
Plugs, Receptacles
and Electrical
Connectors
Meltric Decontactors and NFPA 70E/CSA Z462
This OSHA consensus standard covers electrical
safety related work practices and procedures for
employees who work on or near exposed energized
electrical conductors or circuit parts. Relevant
requirements include:
Meltric Decontactors are switch rated plugs and receptacles.
All Decontactors feature spring-loaded, silver-nickel butt
contacts, dead front construction, enclosed arc chambers
and short-circuit make and withstand ratings of at least
65kA. They are UL and CSA approved for use as a Motor
Circuit Disconnect Switch or a Branch Circuit Disconnect
Switch and thus can be used to connect and disconnect
resistive or inductive loads.
The power must be proven to be off before work
can be performed. This includes:
!
The safe interruption of the load & opening
of the disconnect
!
Visual verification / voltage testing to ensure
deenergization
The potential electrical hazard must be identified
and documented.
!
!
!
!
Switch ratings ensure safe load interruption.
!
Removing the plug provides positive visual verification
of deenergization without voltage testing.
!
Dead front construction prevents exposure to live
parts and maintains NFPA 70E hazard risk category = Ø.
Flash hazard analysis must be performed
Flash protection boundaries must
be determined
Appropriate steps must be taken to protect
persons working near live parts or within the
flash protection boundary.
!
Decontactors unique features allow users to safely and
quickly change-out equipment without the need for NFPA
70E required work procedures and cumbersome PPE.
Personal Protective Equipment must be
provided based on the relevant incident
energy exposure levels (cal / cm2)
Only properly qualified persons shall be
allowed to perform work
!
Plug & play simplicity allows qualified mechanics
to quickly change-out motors. Electrical personnel
are not required at the job site.
In contrast, by using Meltric’s DECONTACTOR
Series plugs & receptacles to connect equipment, users
can avoid ALL these requirements and procedures.
TM
Motor Hard-Wired to a
Bladed Disconnect Switch
After throwing the
disconnect switch, a worker
still needs to verify deenergization. Exposure to live
parts is inevitable, so
PPE is required.
1. Switch disconnect to OFF
2. Apply lockout/tagout
3. Perform Hazard Analysis
4. Obtain permit for energized
electrical work
5. Suit up with appropriate PPE
6. Voltage test to verify
deenergization
Simple and Safe
Push Button Switch Operation
1
Pressing the pawl (DSN
& DS series) breaks the
circuit. The plug is ejected to
its rest position.
Motor Connected with
a Meltric Motor Plug
Mechanics can
quickly and safely make and
break electrical connections,
without special PPE.
1. Switch receptacle to
OFF position
2. Remove plug
3. Apply lockout/tagout
4. Remove old/install
new motor
5. Insert plug into receptacle
7. Disconnect motor
8. Remove old/install new motor
Dead
Front
See published NFPA 70E standard for complete safety requirements.
Wiring and connection systems utilizing conventional
switches and/or pin and sleeve devices would
typically require all of the above listed protective
measures to comply with NFPA 70E/CSA Z462.
Motor Change-out
Process Comparison
QUICK & EASY
DECONTACTORTM Series
Plugs & Receptacles
CUMBERSOME
NFPA 70E/CSA Z462
9. Connect new motor to
hard-wiring
2
The plug and the receptacle
can then be separated. The
safety shutter prevents access
to live parts.
10.Jog the motor to ensure
proper rotation
Using Meltric’s DECONTACTOR TM Series Motor Plugs to connect
motors and other electrical equipment instead of hard-wiring can
help reduce change-out and downtime costs by as much as 50%!