Download Hammond Manufacturing Line Transformers

Survey
yes no Was this document useful for you?
   Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Document related concepts

Islanding wikipedia , lookup

Heterodyne wikipedia , lookup

Stepper motor wikipedia , lookup

Utility frequency wikipedia , lookup

History of electric power transmission wikipedia , lookup

Stray voltage wikipedia , lookup

Power inverter wikipedia , lookup

Variable-frequency drive wikipedia , lookup

Ground loop (electricity) wikipedia , lookup

Electrical substation wikipedia , lookup

Resistive opto-isolator wikipedia , lookup

Three-phase electric power wikipedia , lookup

Voltage regulator wikipedia , lookup

Rectifier wikipedia , lookup

Earthing system wikipedia , lookup

Voltage optimisation wikipedia , lookup

Schmitt trigger wikipedia , lookup

Single-wire earth return wikipedia , lookup

Buck converter wikipedia , lookup

Power electronics wikipedia , lookup

Transformer wikipedia , lookup

Ground (electricity) wikipedia , lookup

Resonant inductive coupling wikipedia , lookup

Alternating current wikipedia , lookup

Tektronix analog oscilloscopes wikipedia , lookup

Switched-mode power supply wikipedia , lookup

Mains electricity wikipedia , lookup

Industrial and multiphase power plugs and sockets wikipedia , lookup

Phone connector (audio) wikipedia , lookup

Opto-isolator wikipedia , lookup

Transcript
Straight Isolation - Hard Wired (169 Series)
LINE ISOLATION
TRANSFORMERS
(115V to 115V)
• Primary 115VAC, 60 Hz., Secondary 115VAC
• Electrostatic shield between primary & secondary
• Connection by flexible leads, 8" minimum length
• Perfect for circuit isolation or "Classic" bias power
supply
• CSA certified (# LR3902)
• Remember - These units do NOT convert line frequency
Transformer Schematic
Blk
Yel
Yel
Secondary
Primary
Blk
Dimensions (Inches)
VA
Sec. Current
ma
A
B
C
D
E
Wt.
Lbs.
169PS
169QS
169RS
169SS
169TS
169VS
169WS
15
40
60
90
135
175
250
130
260
435
650
870
1300
1700
1.88
2.19
2.50
2.50
3.13
3.13
3.75
2.07
2.50
2.75
3.25
3.50
4.00
4.00
2.50
2.63
3.06
3.06
3.81
3.81
4.56
1.50
1.75
2.00
2.00
2.50
2.50
3.00
1.19
1.44
1.69
2.19
2.19
2.69
2.81
1.3
2.5
3.3
4.5
6.5
7
12
LINE ISOLATION - TAPPED
TRANSFORMERS
(115V to 90-130V)
• Primary 115VAC, 60 Hz.
• Secondary taps @ 90, 100, 110, 115, 120 & 130VAC
• Electrostatic shield between primary & secondary
• Connection by flexible leads, 8" minimum length
• Perfect for critical line voltage needs (ex. Japanese 100V equipment).
• CSA certified (# LR3902) - except 169J
• Remember - These units do NOT convert line frequency
Transformer Schematic
130V Red
120V Grn
115V Brn
110V Yel
100V Blk/Red
Blk
Secondary
115V Primary
Blk
Part
No.
Capacity
VA
169C
169E
169G
169J
100
250
500
750
Dimensions (Inches)
A
2.50
3.75
6.75
4.38
B
3.50
4.00
5.50
6.13
C
3.06
4.56
4.56
5.25
D
2.00
3.00
3.00
3.50
E
2.44
2.81
4.31
4.50
Wt.
Lbs.
4
7
15
22
90V Blk/Yel
0V Blu
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Line
Capacity
Part
No.
Line
Straight Isolation - Plug In (171 Series)
LINE ISOLATION
PLUG & RECEPTACLE
TRANSFORMERS
(115V to 115V)
• Primary 115VAC, 50/60 Hz., Secondary 115VAC
• Provides circuit isolation.
• Electrostatic shield between primary & secondary.
• Hi-pot tested to 2 KV RMS.
• Circuit breaker in primary.
• Standard 3-wire, grounded plug & receptacle.
• Input (primary) connected to 5 foot long cord & standard North American plug (NEMA 5-15P).
• Output (secondary) connected to 1 foot long 3-wire, standard North American grounded receptacle (NEMA 5-15R).
• North American Mark of Safety - C UL & UL listed (File #E211544)
• Remember - These units do NOT convert line frequency
Primary 3-wire plug
Secondary 3-wire receptacle
Part
No.
171A
171B
171C
171E
171F
171G
Capacity
VA
100
200
300
500
750
1000
A
3.80
3.80
3.80
3.80
4.40
5.28
Dimensions (Inches)
B
C
D
5.06
4.68
3.00
5.56
4.68
3.00
6.06
4.68
3.00
7.06
4.68
3.00
8.70
5.39
3.50
7.75
6.38
4.25
E
3.38
3.88
4.38
5.38
6.78
4.38
Wt.
Lbs.
6.5
8
11
14
30
34.5
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Toroidal Straight Isolation - Plug In (178 & 240 Series)
Toroidal Isolation
Plug In
(120V to 120V)
Line
• Primary 120VAC, 50/60 Hz., Secondary 120VAC.
• Provides circuit isolation.
• Toroidal transformer for high isolation, low noise, light
weight, cool operation and low profile.
• World wide applications, 50 or 60 Hz. operation, step
down (120VAC to 120 VAC).
• Standard 3-wire, grounded plug (for use with adaptors
for proper grounding).
• Input (primary) connected to a 5 foot long cord &
standard North American plug (NEMA 5-15P).
• Output (secondary) connected to two standard 3 wire grounded receptacles (NEMA 5-15R).
• Features include ventilated black steel case, rocker
lighted on-off switch & circuit breaker protected output.
• North American Mark of Safety - C UL & UL listed
(File #E211544).
• Remember - These units do NOT convert line
frequency.
Part No.
178CT
178DT
178ET
178FT
178GT
Capacity
# of Outlets
VA
250
2
500
2
750
2
1000
2
1500
2
Dimensions (Inches)
Length Width Height
8.25
6.00
4.00
9.00
6.00
4.00
10.25
7.50
5.00
10.25
7.50
5.00
12.50
9.00
5.00
Toroidal Isolation
Plug In
(240V to 240V)
• Primary 240VAC, 50/60 Hz., Secondary 240VAC.
• Provides circuit isolation.
• Toroidal transformer for high isolation, low noise, light
weight, cool operation and low profile.
• World wide applications, 50 or 60 Hz. operation, step
down (240VAC to 240VAC).
• Standard 3-wire, grounded plug (for use with adaptors
for proper grounding).
• Input (primary) connected to a 5 foot long cord &
standard North American plug (NEMA 6-15P).
• Output (secondary) connected to a standard 3 wire
grounded duplex receptacle (NEMA 6-15R).
• Features include ventilated black steel case, rocker
lighted on-off switch & circuit breaker protected output.
• North American Mark of Safety - C UL & UL listed
(File #E211544).
• Remember - These units do NOT convert line
frequency.
Part No.
240CT
240DT
240ET
240FT
240GT
Capacity
# of Outlets
VA
250
500
750
1000
1500
2
2
2
2
2
Dimensions (Inches)
Length
8.25
9.00
10.25
10.25
12.50
Width Height
6.00
4.00
6.00
4.00
7.50
5.00
7.50
5.00
9.00
5.00
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Line
Straight Isolation - Constant Voltage - Plug In (CV Series)
Constant Voltage
A.C. Regulator - Plug In
(120 V to 120V)
• AC regulating - protects against both brownouts & over voltage conditions.
• Protects against any power problem other than a blackout.
• Will operate through a 3 millisecond (minimum) blackout.
• Long life - ferroresonant design - no moving parts.
• Ferroresonant design also filters out surges, line harmonics, and RF noise.
• Input 120VAC (+10 % to -25 %), 60 Hz
• Output 120VAC (+/- 3 %).
• Provides circuit isolation.
• Noise Isolation (RF) of 120 db common mode, 60 db normal mode.
• Spike attenuation: 250:1 minimum.
• Sine wave output - total harmonic distortion (THD): 3 %
• Units also include a 2nd stage of high frequency filtering on the output - a Hammond Mfg. exclusive.
• Operating temperature range of -40 degrees C to +40 degrees C.
• Standard 3-wire, grounded plug & receptacle.
• Front panel lighted power switch.
• Input (primary) connected to an extra long 15 foot, heavy duty 14/3 SJTW cord for extreme temperature ranges.
• Integral molded, standard North American plug (NEMA 5-15P).
• Output (secondary) connected to a rear mounted, standard North American, grounded receptacle (NEMA 5-15R) - quantity depends on power capacity of unit (see table below).
• Rugged two piece ventilated steel enclosure.
• Finished in a grey/beige color, textured powder paint with rubber feet installed.
• NOTE 1: Due to the nature of ferroresonant designs - these units do produce audible noise. We have reduced this through careful design, but these units are NOT usable in an office environment.
• NOTE 2: These units provide complete isolation from the source voltage. In other words, the "neutral" output wire has no connection to ground, this is a UL requirement for this type of device. Therefore plug-in circuit testers & line "polarity" testing devices will NOT function on the output as it is completely isolated.
• North American Mark of Safety: C UL & UL listed (File #E211544).
Part No.
CV120300
CV120600
CV1201200
CV1201800
Capacity
Amps
VA
(RMS)
300
2.5
600
5
1200
10
1800
15
Dimensions (Inches)
Number of
Rear Outlets
Height
Width
Depth
Wt.
Lbs.
2
4
4
6
7.00
9.00
9.00
12.00
7.13
10.13
10.13
12.13
12.30
19.50
19.50
20.50
25.3
48
74
95
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Toroidal Isolation - Step Up - Plug In (298 Series)
Line
LINE ISOLATION
STEP UP - PLUG IN
(120V to 240V)
• Primary 120VAC, 50/60 Hz., Secondary 240VAC.
• Provides circuit isolation.
• Toroidal transformer for high isolation, low noise, light weight, cool operation and low profile.
• World wide applications, 50 or 60 Hz. operation, step UP (120VAC to 240 VAC).
• Standard 3-wire, grounded plug (for use with adaptors for proper grounding).
• Input (primary) connected to a 5 foot long cord & standard North American plug (NEMA 5-15P).
• Output (secondary) connected to a standard N. American duplex - 3 wire grounded receptacles (NEMA 6-15R).
• Features include ventilated black steel case, rocker lighted on-off switch & circuit breaker protected output.
• North American Mark of Safety - C UL & UL listed (File #E211544).
• Remember - These units do NOT convert line frequency.
Part
No.
Capacity
VA
# of
Outlets
298CT
298DT
298ET
298FT
298GT
250
500
750
1000
1500
2
2
2
2
2
Dimensions (Inches)
Length
8.25
9.00
10.25
10.25
12.50
Width
6.00
6.00
7.50
7.50
9.00
Height
4.00
4.00
5.00
5.00
5.00
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Isolation - Step Down - Plug In (172 & 289 Series)
LINE ISOLATION - STEP DOWN
PLUG-IN TRANSFORMERS
(230V to 115V)
Line
• Primary 230VAC, 50/60 Hz. Secondary 115VAC
• Circuit breaker in primary.
• Provides circuit isolation & steps down primary voltage.
• Hi-pot tested to 2 KV RMS.
• Electrostatic shield between primary & secondary.
• Input (primary) connected to a 5 foot long cord & North American 250V, 3-wire grounded plug (NEMA
6-15P).
• Output (secondary) connected to a 1 foot long cord
& standard North American 125V, 3-wire grounded
receptacle (NEMA 5-15R).
• North American Mark of Safety - C UL & UL listed (File #E211544).
• Remember - These units do NOT convert line frequency
Part
No.
172A
172B
172D
172E
172F
Capacity
VA
100
200
500
750
1000
A
3.80
3.80
3.80
4.40
5.28
Dimensions (Inches)
B
C
D
5.06
4.68
3.00
5.56
4.68
3.00
7.06
4.68
3.00
8.70
5.39
3.50
7.75
6.38
4.25
E
3.38
3.88
5.38
6.78
4.38
Wt.
Lbs.
6.5
8.5
18.5
30.0
34.5
LINE ISOLATION - TOROIDAL
STEP DOWN - PLUG IN
(240V to 120V)
Part
No.
Capacity
VA
# of
Outlets
289CT
289DT
289ET
289FT
289GT
250
500
750
1000
1500
2
2
2
2
2
Dimensions (Inches)
Length
8.25
9.00
10.25
10.25
12.50
Width
6.00
6.00
7.50
7.50
9.00
Height
4.00
4.00
5.00
5.00
5.00
• Primary 240VAC, 50/60 Hz., Secondary 120VAC.
• Provides circuit isolation.
• Toroidal transformer for high isolation, low noise, light
weight, cool operation and low profile.
• World wide applications, 50 or 60 Hz. operation, step
down (240VAC to 120 VAC).
• Standard 3-wire, grounded plug (for use with adaptors
for proper grounding).
• Input (primary) connected to a 5 foot long cord &
standard 250V 2 pole, 3 wire - North American plug
(NEMA 6-15P).
• Output (secondary) connected to two standard 125V,
3-wire grounded receptacles (NEMA 5-15R).
• Features include ventilated black steel case, rocker
lighted on-off switch & circuit breaker protected output.
• North American Mark of Safety - C UL & UL listed (File #E211544)
• Remember - These units do NOT convert line frequency
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Isolation - Step Down - Plug In (179 Series)
Line
LINE ISOLATION
STEP DOWN - PLUG IN
(115V to 95V)
• Primary 115VAC, 50/60 Hz., Secondary 95VAC.
• Provides circuit isolation.
• Electrostatic shield between primary & secondary.
• World wide applications, 50 or 60 Hz. operation, step down (115VAC to 95VAC).
• Designed mainly for Japanese equipment operating in North America.
• Perfect for operating "Classic" equipment that can not tolerate todays higher line voltages (ie..125VAC input will
produce a stress free 105VAC output - at full load - PLUS - isolation and shielding).
• Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding).
• Input (primary) connected to a 5 foot long cord and standard 3-wire, 125V North American plug (NEMA 5-15P).
• Output (secondary) connected to two standard 3-wire, 125V grounded receptacles (NEMA 5-15R).
• Features include ventilated black steel case, rocker lighted on-off switch & fuse protected output.
• Remember - These units do NOT convert line frequency
Part
No.
Capacity
VA
# of
Outlets
179C
179D
179E
179F
179G
250
500
750
1000
1500
2
2
2
2
2
Dimensions (Inches)
Length
6.00
6.00
7.00
7.00
8.50
Width
6.75
8.25
8.25
9.75
9.00
Height
4.75
4.75
5.38
5.38
6.75
Output 3-wire
receptacle (2)
Input 3-wire plug
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
"Auto" - Hard Wired (170 Series)
HARD WIRED
LINE AUTOTRANSFORMERS
Line
• Single winding, does not provide isolation, for use where
equipment is already isolated and only voltage change
is required.
• Flexible world wide applications, 50 or 60 Hz. operation,
step down (230VAC to 115 VAC) or step up
(115VAC to 230VAC).
• Connection by flexible leads, 8" minimum length.
• Models 170A, 170B, 170C & 170D are CSA certified
(# LR 3902).
• Remember - These units do NOT convert line
frequency.
Part
No.
Capacity
VA
170
170A
170B
170C
170D
170E
170F
170G
170J
50
100
200
300
500
750
1000
1500
2000
Dimensions (Inches)
A
2.19
2.50
3.13
3.13
3.75
3.75
3.75
4.38
4.38
B
2.63
3.00
3.50
4.00
4.50
5.50
5.50
6.63
6.63
C
2.63
3.06
3.81
3.81
4.56
4.56
4.56
5.30
5.25
D
1.75
2.00
2.50
2.50
3.00
3.00
3.00
3.50
3.50
Wt.
E Lbs.
1.56
2
1.94
3
2.19 4.5
2.69
6
3.31 10
4.31 14
4.31 14.5
5.10 22
5.10 23
230V Red
115V Blk
0V Yel
HARD WIRED
LINE AUTOTRANSFORMERS
Part
No.
Capacity
VA
170SE
170AE
170BE
170CE
170DE
170EE
170FE
170GE
170JE
50
100
200
300
500
750
1000
1500
2000
Dimensions (Inches)
A
3.13
3.13
3.13
3.13
3.75
3.75
3.75
4.38
4.38
B
4.00
4.00
4.25
4.75
5.00
6.00
6.00
7.00
7.00
C
4.13
4.13
4.13
4.13
4.88
4.88
4.88
5.50
5.50
D
2.25
2.25
2.25
2.25
2.75
2.75
2.75
3.25
3.25
E
3.13
3.13
3.38
3.88
4.13
5.13
5.13
5.88
5.88
Wt.
Lbs.
3.5
4
5
6.5
10
15
15.5
23.5
24.0
• Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required.
• Flexible world wide applications, 50 or 60 Hz. operation, step down (230VAC to 115 VAC) or step up (115VAC to 230VAC).
• Totally enclosed rear case, includes handy internal grounding bolt.
• Extra vacuum varnish for use in high humidity.
• Includes a rear mounted (but not wired), standard 115VAC, 3-wire receptacle.
• Enclosed case with convenient knockouts and includes two cable clamps allowing for easy wire connections.
• Models 170SE, 170AE, 170BE, 170CE & 170DE are CSA certified (# LR3902)
• Connection by flexible leads, 8" minimum length
• Remember - These units do NOT convert line frequency.
230V Red
115V Blk
0V Yel
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
"Auto" - Hard Wired (168 Series)
• Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is required.
• Flexible world wide applications, 50 or 60 Hz. operation, 115VAC input.
• Output taps @ 85, 95, 105, 110, 115 and 125VAC.
• Ideal for manual line voltage adjustment for electronic equipment or small appliance operation.
• Models 168B, 168C & 168D are CSA certified (# LR3902)
• Connection by flexible leads, 8" minimum length.
• Remember - These units do NOT convert line frequency.
Part
No.
Capacity
VA
168B
168C
168D
168E
168F
168H
168J
200
350
500
750
1000
1500
2000
Dimensions (Inches)
A
3.13
3.13
3.75
3.75
3.75
4.38
4.38
B
3.25
4.00
4.00
4.50
5.50
6.13
6.63
C
3.81
3.81
4.56
4.56
4.56
5.25
5.25
D
2.50
2.50
3.00
3.00
3.00
3.50
3.50
Wt.
E Lbs.
1.94 4.3
2.69 6.5
2.81
8
3.31 10
4.31 14
4.50 20
5.10 23
125V Orn
115V Yel
110V Red
105V Grn
95V Brn
85V Wht
0V Common Blk
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Line
HARD WIRED
LINE AUTOTRANSFORMERS
Line
"Auto" Step Down - Plug In (175 Series)
PLUG IN - STEP DOWN
AUTOTRANSFORMERS
(230V to 115V)
• Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is
required.
• World wide applications, 50 or 60 Hz. operation, step down (230VAC to 115VAC).
• Input is circuit breaker protected.
• Hi-pot tested to 2 KV RMS.
• Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding).
• Input connected to a 5 foot cord & grounded North American 250V 3-wire plug (NEMA 6-15P).
• Output connected to standard North American
115V - 3 wire grounded receptacle (NEMA 5-15R).
• North American Mark of Safety - C UL & UL listed - File #E211544
• Remember - These units do NOT convert line frequency.
Part No.
175A-NA
175B-NA
175C-NA
175D-NA
175E-NA
175F-NA
175G-NA
Capacity
VA
100
200
300
500
750
1000
1500
A
3.16
3.16
3.16
3.80
3.80
3.80
4.40
Dimensions (Inches)
B
C
D
4.25
3.81
2.50
4.50
3.81
2.50
5.00
3.81
2.50
6.00
4.68
3.00
7.06
4.68
3.00
7.06
4.68
3.00
6.63
5.39
3.50
E
2.94
3.19
3.69
4.38
5.38
5.38
6.09
Wt.
Lbs.
3.5
4.5
6
10
14
14.5
22
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
"Auto" Step Up - Plug In (176 Series)
Line
Autotransformer
Step Up - Plug In
(115V to 230V)
• Single winding, does not provide isolation, for use where equipment is already isolated and only voltage change is
required.
• World wide applications, 50 or 60 Hz. operation, step up (115VAC to 230VAC).
• Input is circuit breaker protected.
• Hi-pot tested to 2 KV RMS
• Standard 3-wire, grounded plug (can also be used with adaptors for proper grounding).
• Input is connected to a 5 foot cord & standard grounded 125V North American plug (NEMA 5-15P)
• Output is connected to a grounded North American 250V receptacle (NEMA 6-15R).
• North American Mark of Safety - C UL & UL listed (File #E211544)
• Remember - These units do NOT convert line frequency.
Part No.
176A
176B
176C
176D
176E
176F
176G
Capacity
VA
120
200
300
500
750
1000
1500
A
3.16
3.16
3.16
3.80
3.80
3.80
4.40
Dimensions (Inches)
B
C
D
4.25 3.81 2.50
4.50 3.81 2.50
5.00 3.81 2.50
6.00 4.68 3.00
7.06 4.68 3.00
7.06 4.68 3.00
6.63 5.39 3.50
E
2.94
3.19
3.69
4.38
5.38
5.38
6.09
Wt.
Lbs.
3.5
4.5
6
10
14
14.5
22
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
Line Transformers - Accessories
INTERNATIONAL - GROUNDED
ADAPTOR PLUGS
Line
• For use with our 171, 172, 175, 176, 179, 289 & 298 transformers.
• Heavy duty design with plastic shell & double wipe contacts.
• Allows for ground connection between equipment and international power sources.
• With a set of all 4 adaptors, they will accept equipment with plugs from virtually every country except South Africa!
• Adaptors do not affect voltages, they are a mechanical device only to match foreign "pin-
outs" of receptacles and/or plugs.
Part
No.
Grounded Plug
Type
298G4
European
298G3
298G6
298G7
British
Australian
N. American
298G4
Used in the Countries of:
Austria, Belgium, Finland, France, Germany, Middle East, Netherlands, Norway,
Parts of Africa/Asia/South America/China/Tahiti & Caribbean, Sweden
Hong Kong, Ireland, Malaysia, Parts of Africa, Caribbean, Singapore, U.K.
Australia, People’s Republic of China, S. Pacific Islands, New Zealand
Canada, Parts of the Caribbean/South America, Philippines, USA
298G3
298G6
Rear View of all
adaptors
298G7
www.hammondmfg.com
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]
©
Line Transformer - Selection Guide
Steps To Proper Transformer Selection
1. What power is available (you need to know both voltage & frequency)?
2. Check the operating voltage of your equipment (is it single voltage or multiple?).
3. What line frequency will your equipment run on? Either 50, 60 or dual 50/60 Hz. (remember, a transformer can NOT
change line frequency).
4. Use the chart below to determine your requirements:
Line
Power Available
Voltage Frequency
115
60
115
50
115
50
115
50
115
60
115
60
115
60
115
60
230
50
230
50
230
50
230
60
230
60
230
60
230
60
1.
2.
Your Equipment
Voltage Frequency
100
50/60
115
50
115
60
115/230
50/60
115
60
230
50
230
60
115/230
50/60
115
50
115
60
115/230
50/60
115
60
230
50
230
60
115/230
50/60
Transformer Type Required
(You may also need plug adaptors)
Step Down
None Required - or - Straight Isolation
Will Not Work
None Required - or - Straight Isolation
None Required - or - Straight Isolation
Will Not Work
Step Up
None Required - or - Straight Isolation
Step Down
Will Not Work
None Required - or - Straight Isolation
Step Down
Will Not Work
None Required - or - Straight Isolation
None Required - or - Straight Isolation
Determine if your equipment is Electronic or Electrical:
- Electronic = containing IC chips, transistors or a circuit such as a radio, shavers, electric toothbrush, computer
printers, camcorder battery rechargers etc...(if in doubt, check with the manufacturer or refer to your manual).
- Electrical = Simple heating device, such as irons, hair dryers, electric blankets, curling irons, etc...
Use the chart below to locate correct series & voltage conversion in the catalog series that follow:
Transformer Type
Your Equipment Type
(determined from
Electronic
Electrical
chart above)
Step Up
Use Isolation (series 298)
Could use “Auto” (series 170 or 170E)
Step Down
Use Isolation (series 172, 179 or 289) Could use “Auto” (series 175)
Straight Isolation Use Isolation (series 169 or 171)
-
IMPORTANT NOTES
Isolation Transformers: Used for maximum safety, versatility (can be used on both electrical & electronic equipment)
and isolation from the power source, used to step-up, step-down or for straight isolation. The disadvantage to using
them is weight (about double the "Auto"), more expensive and larger size. This type of transformer is sometimes referred to as "double-wound"
"Auto" Transformers: are non-isolating units and should be used where only a voltage change is required. The advantages to using them are light weight (generally half that of an isolation unit), less expensive and smaller size. The
disadvantage is no isolation from the power source. This type of transformer is sometimes referred to as a "converter".
Adaptors: We strongly recommend that 3-prong "grounded" plugs be used with all of our products. They should be
used only with our "grounded" adaptors. Adaptors do not affect voltages, they are a mechanical device only to match
foreign "pin-outs" of receptacles and/or plugs.
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: [email protected]