* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Download Evaluation of Diastolic Dysfunction by Echocardiogram
Cardiovascular disease wikipedia , lookup
Electrocardiography wikipedia , lookup
Heart failure wikipedia , lookup
Coronary artery disease wikipedia , lookup
Echocardiography wikipedia , lookup
Cardiac surgery wikipedia , lookup
Antihypertensive drug wikipedia , lookup
Myocardial infarction wikipedia , lookup
Artificial heart valve wikipedia , lookup
Hypertrophic cardiomyopathy wikipedia , lookup
Jatene procedure wikipedia , lookup
Lutembacher's syndrome wikipedia , lookup
Quantium Medical Cardiac Output wikipedia , lookup
Atrial fibrillation wikipedia , lookup
Dextro-Transposition of the great arteries wikipedia , lookup
Arrhythmogenic right ventricular dysplasia wikipedia , lookup
Evaluation of Diastolic Dysfunction by Echocardiography Brandon Kuebler, MD Pediatric Cardiology Fellow Wednesday, February 09, 2011 Assessment of Diastolic Ventricular Function  Defining diastole  Methods to assess diastole  Patterns of diastolic disease  Age-related changes When does diastole occur?  Is it around tea time?   No Required for every heart beat Systole Diastole Phases of Diastole  Isovolumetric relaxation  Rapid filling  E-wave  2/3 LV filling  Diastasis  Atrial contraction  A-wave  1/3 LV filling Factors Affecting Diastole        Ventricular function AV valve function Rate of relaxation Ventricular compliance Atrial systolic function Preload Heart rate and rhythm Pulmonary Venous Inflow    Apical 4-chamber view Identify RUPV or LUPV inflow parallel to beam Pulsed-wave sampling   Alternatives views:  Place Apical 4 w PW in Distal PV 1-2 cm distal to orifice   Parasternal Suprasternal Subcostals Pulsed-wave Pulmonary Vein Inflow   Identify peak S and D velocities Measure atrial reversal (AR) duration  AR presence is variable. It is indicative of abnormal elevated LA pressure in a neonate, but may be normal in a child with more compliant pulmonary veins. The duration of flow reversal is more helpful in relation to atrial systole   Note: S-wave may be biphasic owing to differences of atrial relaxation and mitral valve annular displacement Should take the highest of the peaks Mitral Inflow    Apical 4-chamber view Align Doppler beam to be parallel to mitral inflow Pulsed-wave sampling at tips of MV leaflets  Decreased velocity if sampled within LA Pulsed-wave Mitral Valve Inflow     Peak E and A velocities, ratio E/A Mitral A-wave duration (to compare with PV AR duration) Mitral deceleration time(from peak of E-wave to base) Mitral Doppler VTI (and valve area) Mitral Valve Doppler Evaluation  In a 5 chamber view Continuous-wave across tips of MV through LVOT  Obtain mitral inflow & LV outflow  Measure Isovolumetric Relaxation Time (IVRT)  Tissue Doppler   Measures displacement of myocardium while avoiding blood flow detection throughout the cardiac cycle For our purposes: Mitral valve annular junction  Septal annular junction  Tricuspid annular junction   Mitral and tricuspid data is relatively volume load independent, including respiratory cycle TDI Methodology      Using Doppler pulsed cursor, 3-5 mm Set Nyquist limits to 1530 cm/s Using lowest wall filter Set dynamic range to 3035db Sweep speed of 100-150 mm/s TDI Pulsed-wave    Ea ( or E´), Aa ( or A´), Sa ( or S´) waves IVRT and Isovolumetric Contraction Time (IVCT) Important to maintain a parallel line of annular motion with the imaging beam Color M-mode Flow Propagation     Estimate of ventricular filling to correlate with LV relaxation, even at increased LA pressures Not affected by preload Varies with changes of lusitropic conditions Correlates in ischemic heart disease Color M-mode Flow Propagation      In apical 4 chamber view Align M-mode cursor through LV apex and orifice of MV Apply Color Doppler Switch to M-mode acquisition Decrease Nyquist limit until color inflow shows line of aliasing Color M-mode Flow Propagation  Demonstrated by Garcia et al., JACC 1999, that in both dogs with occluded IVC and in adults undergoing CABG, under partial CPB, measures were not affected   Although, MV E waves and associated measures were impacted by each scenario In dogs, under various doses of dobutamine and esmolol, there were expected changes of Vp correlating to measured changes of LVEDp Calculations using Vp   Border et al, JASE 2003 20 pts age 6.6yrs ± 6yrs  Indicated L heart cath w/o MV stenosis/arrhythmia  Found E/ Vp > 2.0,      LVEDp >15mmHg Sensitivity 100% Specificity 77% PPV: 70% NPV: 100% Calculations using Vp(FPV)      Gonzalez-Vilchez, JACC 1999 Adults in ICU w Swan’s 20 test, 34 study patients Estimated PCWP = 4.5(103/[2•IVRT]+FPV)-9 Simplified to:  103/[2•IVRT]+FPV  Value ≥5.5, correlates to PCWP > 15mmHg (r=0.89) Calculations using Vp Use of TDI and Color M-mode in Infants    Study by Larrazet et al, Pediatric Critical Care Medicine, 2005 Studied infants 3-8 months of age, immediately post-operatively for VSD/AVCD repair w LA line in place For LA pressure > 10mmHg E/Ea > 15 – Sensitivity 94%, Specificity 72%  E/Vp >2.0 – Sensitivity 83%, Specificity 89%  LA Volume In adults, atrial dilation has correlated as a risk for first CV event (a-fib, stroke, CHF)  Defined as: women ≥ 30cm2/m2, men ≥ 33cm2/m2  Not routinely measured in children, but recent norms established  8/3π[(A1)(A2)/(L)] obtained from Apical 2 & 4 chamber views LA Volume in Children  Data collected by 3D Echo and separated by BSA 0.5-0.75m2 :  0.75-1.0m2 :  1.0-1.25m2 :  1.25-1.5m2 :  >1.5m2 :   19.6 mL/m2 21.7 mL/m2 22.0 mL/m2 24.5 mL/m2 27.4 mL/m2 No normative values for RA established in kids Tricuspid and Right Heart Evaluation  Usual measures performed on MV, are influenced by variable preload through the respiratory cycle.  With inspiration amongst children Peak E may increase by 26%  Peak A may increase by 20%  Tricuspid and Right Heart Evaluation   SVC inflow invariably does not have AR amongst healthy children AR-wave usually seen with:    Reversal with ventricular systole     Right atrial hypertension Tricuspid stenosis Significant tricuspid regurgitation Loss of AV-synchrony Restrictive physiology Decreased flow of systemic veins or TV inflow with Exhalation seen with Tamponade  MV E-wave decreases by >25% during onset of INhalation Tricuspid and Right Heart Evaluation  In a restrictive, non-compliant RV, which acts essentially as a conduit for the PA Forward flow may be seen in PA with atrial systole  Only in settings with low PVR or absence of distal stenoses  May be seen in those with history of Tetralogy or Pulmonary valve abnormalities  Classification of Diastolic Dysfunction Classification of Diastolic Dysfunction Abnormal LV Relaxation  The ability of the LV myocardial filaments to actively uncouple after systole, is delayed  Ventricular compliance is unaffected  IVRT is prolonged, as time needed to decrease LV pressure < LA pressure is extended Abnormal LV Relaxation Insert fig 8.14  LA-LV pressure difference in early diastole narrowed – max E-wave velocity decreased  LV relaxation is slower, so Ewave is prolonged  A-wave increased as a compensatory to complete LV filling Insert fig 8.15 Abnormal LV Relaxation  Infamous “L-wave” seen in MV inflow pattern    Described by Keren in 1986 Presence of LA-LV pressure gradient in diastasis Occurs with MARKEDLY delayed LV relaxation Abnormal LV Relaxation … and LA Hypertension     Also called “Pseudonormalization” Result of worsened ventricular compliance with transmitted increase of atrial pressure Ultimately, relative pressure difference between LA-LV is similar to normal, just at higher pressure Pulmonary vein inflow pattern helpful to distinguish this from normal Abnormal LV Relaxation … and LA Hypertension  TDI has been shown to be relatively independent of preload Abali et al, JASE 2005, studied 100+ adult males after 500mL blood donation, found no differences in TDI measures or Color M-mode, Vp  Eidem et al, JASE 2005, found that children with chronic LV preload (VSD’s) and preserved systolic and diastolic function, did not have changes in TDI   Those with chronic afterload (AS) demonstrated decreases of TDI measures Abnormal LV Relaxation … and LA Hypertension    Nagueh et al, JACC 1997 125 adults, 60 cathed for PCWP, separated Normal from Impaired Relaxation from Pseudnormalized (EF low in this group) Found E/Ea >10 correlated to PCWP of >12mmHg  Sensitivity 91%, Specificity 81% Nagueh et al, JACC 1997 Could predict mean PCWP= 1.24(E/Ea ) +1.9 TDI in Pseudonormalization Nagueh et al, JACC 1997, 30; 1527-33 Color M-mode in Pseudonormalization     Helpful to differentiate normal MV inflow patterns from ‘pseudonormalization’ Decreased rate of flow propagation (Vp) correlate with delayed relaxation, even with elevated LA pressure Measures are preload independent Measure of MV peak E velocity to rate of flow propagation, E/ Vp > 2.0 predicts LVEDp >15mmHg (sensitivity 100%, specificity 77%) Restrictive Physiology/Decreased Ventricular Compliance  Ventricle is significantly stiff, non-compliant, that with small increases of volume, pressures increase disproportionately  On MV inflow, the E-wave is accelerated with short deceleration time due to rapid rise of ventricular pressure and the end of inflow  A-wave is remarkably small, if not absent all together, as atrial systole minimally generates a pressure gradient across the AV valve  Instead prolonged reflux in PV observed Restrictive Physiology/Decreased Ventricular Compliance  IVRT shortened due to atrial hypertension with early opening of MV and ventricular filling Measures through childhood  Infants Very limited early diastolic flow  Significant contribution from atrial systole  Limited tolerance to changes in preload  Improved compliance around 2 months   Childhood Limited variability of measures (Inflow/TDI) through childhood and adolescence  Noted changes with increasing IVRT likely associated with age-related decreased HR  Tables of normative values for children are available Tables of normative values for children are available Let’s apply our data 52.4 cm/s 57.0 cm/s Let’s apply our data 144 cm/s 72 cm/s 2.0 130 108 ms 90 ms Let’s apply our data 13.1 cm/s 11 Vs= Vp x Li Vs = strength of early filling Vs Strength of Filling      In a recent article by Stewart et al., JACC Imaging 2011 Found that in addition to a decreased filling velocity (Vp) with diastolic dysfunction, the velocity further slowed closer to the MV than the apex (Li) Vs= Vp x Li Found this measure to have better correlation to goldstandard than Vp alone Would like to see used with other measures to further strengthen accuracy and separation of abnormal states Looking at Vp 69 cm/s E/Vp= 2.0 Estimated PCWP = 4.5(103/[2•IVRT]+FPV)-9 4.5(103/[2•60]+69)-9 = 15 mmHg Simplified version = 103/[2•IVRT]+FPV 103/[2•60]+69 = 5.2 To summarize our non-invasive data E/Vp= 2.0 So by our echo data…  I would classify this patient as having  RESTRICTIVE PHYSIOLOGY He just so happened to have been cathed just before I obtained these measures… I did not know these results Disease states   Hypertrophic cardiomyopathy Chronic disease states HOCM   Abnormalities of E/Ea, color M-mode flow propagation, and diastolic strain rates have correlated with abnormal relaxation and predict LV filling pressures. TDI (DTI) has been found to be predictive of adverse outcomes E/Ea >12 predicted risk for SCD, Cardiac Arrest, and VT  Those without, events had range 7.4-11.2  Those with symptoms had ratio higher compared to those without (11.9 vs 8.1)  Distinguishing HOCM from Athletic Heart  Diastolic TDI annular patterns, IVRT, and LA volume have identified HOCM in absence of pathologic changes  Early diastolic TDI velocities (Ea) Athletes: normal to increased  HOCM: consistently decreased, often Ea/Aa <1.  Children with Chronic Dz’s  Renal failure  Those on dialysis had changes on echo compared to normal controls:    Increased LV mass with preserved systolic function Evidence of diastolic dysfunction: higher E’s, lower Ea’s and therefore increased E/Ea ratios Obesity   Demonstrated changes with Ea (↓) and Aa (↑) velocities where the ratio Ea/Aa was < controls Demonstrated changes with strain rate imaging also noted Children with Chronic Dz’s  Obstructive sleep apnea Evidence of diastolic dysfunction correlated with severity of sleep apnea  Measures improved with effective therapies   Anthracycline toxicity Demonstrated changes with Ea (↓) and Aa (↑) velocities, Ea/Aa ratio is ↓↓↓  Persists over time, even without evidence of systolic dysfunction  Congenital Heart Disease  Aortic Stenosis Measures are more pronounced in more severe disease  Does not resolve immediately with relief of obstruction  Changes/improvement correlate more with degree of ventricular hypertrophy  Congenital Heart Disease  Single ventricles Demonstrated impaired relaxation, decreased peak E velocities, presence of mid-diastolic filling waves, decreased E/A velocity ratio  Different pulmonary venous inflow patterns due to different sources of pulmonary antegrade blood flow  In well functioning single ventricles, biphasic pulmonary venous inflow still seen (mid-systolic peak, and late diastolic peak)  Congenital Heart Disease  Single ventricles  With decrease ventricular systolic function Decreased systolic flow in PV  Increased late diastolic flow in PV  Seems to correlate with changes in EF   Serial studies in HLHS No differences in early stages within 1st year of life  Need more longitudinal studies  Congenital Heart Disease  TGA  Atrial Switches (Senning/Mustard) Found to have decrease IVCT, and sensitive to changes of systemic RV dysfunction in adolescents and young adults  Measures of TDI are lower than normals, as expected  More data needed for the population, esp Arterial Switches  References  Frommelt, P. (2009). Diastolic Ventricular Function Assessment. In WW Lai, LL Mertens, MS Cohen, T Geva (Eds), Echocardiography in Pediatric and Congenital Heart Disease (1st Edition, p95-118). Hoboken, USA: Wiley-Blackwell.  Garcia MJ, et al. Color M-mode doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation. JACC 2000; 35: 201-8. Nagueh SF, et al. Doppler tissue imaging: a noninvasive technique for evaluation of left ventricular relaxation and estimation of filling pressures. JACC 1997; 30: 1527-33. Eidem BW, et al. Impact of chronic left ventricular preload and afterload on doppler tissue imaging velocities: a study in congenital heart disease. J Am Soc Echocardiogr 2005; 18: 830-8. Larrazet F, et al. Tissue doppler echocardiographic and color M-mode estimation of left atrial pressure in infants. Pediatr Crit Care Med 2005; 6: 448-53. Gonzalez-Vilchez F, et al. Combined use of pulsed and color M-mode doppler echocardiography for the estimation of pulmonary capillary wedge pressure: an emperical approach based on an analytical relation. JACC 1999; 34: 515-23. Border WL, et al. Color M-mode and doppler tissue evaluation of diastolic function in children: simultaneous correlation with invasive indices. J Am Soc Echocardiogr 2003; 16: 988-94. Abali G, et al. Which doppler parameters are load independent? A study in normal volunteers after blood donation. J Am Soc Echocardiogr 2005; 18: 1260-5. Stewart KC, et al. Evaluation of LV diastolic function from color M-mode echocardiography. J Am Coll Cardiol Img 2011; 4: 37-46.