• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Slide 1
Slide 1

... separate unit installed with electro-mechanical meters, used to transmit data from the meter to the ...
84870210 - Crouzet
84870210 - Crouzet

... The output relay remains open as long as the level of liquid has not reached the maximum probe. Once the maximum level is reached the contact closes and the tank can then be emptied (valve opened, pump started, etc). When the level drops below the minimum level the contact opens and interrupts the e ...
English User`s Manual
English User`s Manual

... installations. Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation. ...
244LD Intelligent Displacer Level (Interface) Transmitter
244LD Intelligent Displacer Level (Interface) Transmitter

... 244LD intelligent displacer level (interface) level transmitter is designed based on Archimedes Buoyancy Principle. It can be used for measuring liquid level, interface and density. The latest model of FDT/DTM technology can provide online calibration and diagnosis, durable in use. A wide range of m ...
guitar amplifier
guitar amplifier

... Connecting to the Insert jack: The Insert jack (#8) lets you patch external effects into the amplifier prior to its power amp stage. Use Crate’s STP201, STP202 or STP203 stereo-to-mono Y-cord or an adapter such as Crate’s YPP117 and 2 1/4” mono signal cables to connect to the effect as shown: Stereo ...
Surface Resistance Test Kit
Surface Resistance Test Kit

... or more frequently if specified by contract or company policy. Your instrument should also be recalibrated any time it has been repaired or tampered with. We are happy to recalibrate your instrument for you at a reasonable cost, or provide information and procedures on calibration upon request. ...
Falcon F35 Series Digital Panel Meter AC/TRMS Voltage
Falcon F35 Series Digital Panel Meter AC/TRMS Voltage

... (45mm) high by 3.62" (91.9mm) wide. To install the Falcon into a panel cutout, remove the clips from the side of the meter. Slide the meter through your panel cutout, then slide the mounting clips back on the meter. Press evenly to ensure a proper fit. ...
PowerLogic EM4800 - Schneider Electric
PowerLogic EM4800 - Schneider Electric

... PowerLogic EM4800 meters are ideal for both retrofit and new installations. ● Flexible installation options allow the product to be effectively used in virtually any commercial building that requires highly accurate and cost effective energy metering ● The rugged enclosure allows the meter to be eit ...
NFPA 70E and Electrical Testing Safety
NFPA 70E and Electrical Testing Safety

... Electrical Testing and Meter Design Safety in the electrical testing industry has taken on a new level of importance with the focus on Arc Flash hazards that is embodied in the NFPA 70E Standard for Electrical Workplace Safety. NFPA 70E covers the range of electrical safety issues such as work pract ...
63-1337-01 - Class 200 Meters Three-Phase Meters
63-1337-01 - Class 200 Meters Three-Phase Meters

... The Honeywell Class 200 kWh meters are fully electronic,lowcost meters for monitoring electrical usage in multifamily,commercial and industrial applications. ...
P4 Datasheet - Hawker Electronics
P4 Datasheet - Hawker Electronics

... cover a wide range of level control applications. Electrodes available in 316L Stainless Steel, Hastelloy C, Monel, titanium, etc, supplied plain or suitably insulated. Refer to data sheet No 241 for ...
POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS
POWER FACTOR METERS LF 72 / LF 96 ANALOGUE METERS

... Clamp Meters Insulation Testers SUBJECT TO CHANGE WITHOUT NOTICE This manual superseded all previous versions – please keep for future reference ...
VCS331Z, VCS332Z, VFP4Z, CSNG
VCS331Z, VCS332Z, VFP4Z, CSNG

... Information provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of applications are based on Vishay Precision Group’s knowledge of typical requiremen ...
instruction manual
instruction manual

... under test; set the meter to the desired function and range; connect the test leads to the meter first, then connect to the circuit under test. Reapply power. If an erroneous reading is observed, disconnect power immediately and recheck all settings and connections. This meter is designed for trade ...
permanent-magnet moving-coil movement
permanent-magnet moving-coil movement

... Whenever electrons flow through a conductor, a magnetic field proportional to the current is created. This effect is useful for measuring current and is employed in many practical meters. Since most of the meters in use have D'Arsonval movements, which operate because of the magnetic effect, only th ...
1. Appointment and sphere of application
1. Appointment and sphere of application

... button of operation behind the front cover of the electricity meter, specialized super-power (VLSI) integrated circuit, 8-bit microcontroller for data processing and logging, electrically reprogrammable ROM (EEPROM) for storage of load profile, configuration data and auxiliary constants, EEPROM rese ...
GR 614-C Selective Amplifier, Manual
GR 614-C Selective Amplifier, Manual

... fier is designed fo~ producing with ten fixed tuned circuits; any one of and selecting the first ten harmonics of a which may be placed in circuit by means of distorted 1000- cycle voltage applied to the FREQUENCY switch . A stage of amplifi its input terminals . The instrument is cation follows the ...
resp1 impedance pneumograph
resp1 impedance pneumograph

... Move power switch to ON position. Meter will swing off scale, then return to center (zero) position in about 30 seconds. ...
1551-B Sound Level Meter, Manual
1551-B Sound Level Meter, Manual

... specified weighted sound levels, using this rule of thumb: A weighting fo-r sound levels from 24 to 55 db, B for levels from 55 to 85 db, and C for levels from 85 to 140 db. (The appropriate range was selected after a preliminary C-weighted measurement.) More recent opinions favor selection of weigh ...
an266 vcxo tuning slope (kv), stability, and absolute
an266 vcxo tuning slope (kv), stability, and absolute

... VCONTROL pin of the VCXO will be converted into output jitter with a voltage-to-frequency gain equal to Kv. The PLL designer should be careful not to overlook this factor when selecting a VCXO device. VCXO data sheets typically give specifications for intrinsic jitter and/or phase noise under ideal ...
Runaway Energy Meters due to Conducted Electromagnetic
Runaway Energy Meters due to Conducted Electromagnetic

... Some consumers are complaining about their energy bills after replacement of the energy meter, because the registered energy is higher with the static meter compared to the old Ferraris meter. The utility companies use the argument that the old meters were incorrect because of mechanical wear and co ...
DPM-3232 Digital DC Power Meter with Data logging capability User Manual
DPM-3232 Digital DC Power Meter with Data logging capability User Manual

... The DPM-3232 digital DC Power Meter measures and displays in real time; DC Voltage (0-60V), DC Current (060A) and Watts (0-3600W). It also displays; Amp-hour, W att-hour, maximum or peak Watts, running time since Power Meter start up and minimum and maximum values of voltage and current during the m ...
ELEC 103 LABORATORY EXERCISE 4 RESISTANCE
ELEC 103 LABORATORY EXERCISE 4 RESISTANCE

... 4. Adjust the STATUS/POLARITY switch to the +DC position and make certain the multimeter test leads are in the proper receptacles. Turn the RANGE switch to the R X 1 range and short (connect together) the two meter leads. Observe that the meter pointer moves up the scale and comes to rest somewhere ...
Wireless Optical PPM Telemetry and the Influence of Lighting Flicker
Wireless Optical PPM Telemetry and the Influence of Lighting Flicker

... flicker frequency is usually in the range of 40 kHz to 100 kHz. At the same time, the modulation index is large, i.e., in the range 50% to 100%, depending on the supply frequency [8]. To investigate when lamp flicker is detrimental, the amount of infrared radiation was measured for several lamps. Si ...
Slide 1
Slide 1

... PowerLogic EM4800 meters are ideal for both retrofit and new installations. ● Flexible installation options allow the product to be effectively used in virtually any commercial building that requires highly accurate and cost effective energy metering ● The rugged enclosure allows the meter to be eit ...
< 1 ... 22 23 24 25 26 27 28 29 30 ... 36 >

Peak programme meter



A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report