• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
Islide13-Metering
Islide13-Metering

... • Digital meters normally have high input impedance. • Accuracy of analogue meters are specified in Ohms per Volt. • Digital meters are simple to read - the display is normally clear. • Analogue meters are good when making adjustments, when you are looking for a change in values. • The reading of an ...
Opman SC5X v09.qxd - Fieldpiece Instruments
Opman SC5X v09.qxd - Fieldpiece Instruments

... For accuracies of ±1°, calibrate to a known temperature. A glass of stabilized ice water is very close to 32°F (0°C) and is usually very convenient but any known temperature can be used. 1. Select 400°F/C range and connect thermocouple. 2. Remove back case (2 screws on back, one near clamp, other ne ...
SP 300-BLUE - Lascar Electronics
SP 300-BLUE - Lascar Electronics

... The SP 300-BLUE features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user selectable. The SP 300-BLUE features a negative rail generator which enables the meter to measure a signal referenced to its own power supply 0V. The blue LED display ensures excellent r ...
MY-64 Digital Multimeter use
MY-64 Digital Multimeter use

... • The red cable is inserted into the “VΩHz” jack. • The black cable is put into the “COM” (ground) jack. • The range switch is turned to somewhere in the AC volts group (AC volts appears as V~ on the meter). • Voltage measurements are made by placing the meter leads across (in parallel with) a compo ...
Experiment 2 - Department of Electrical and Electronics Engineering
Experiment 2 - Department of Electrical and Electronics Engineering

... Basic meter is the main construction element of the AVO meters that we are using in the laboratory. Essentially it is an ammeter, but by some modifications one is able to measure voltage and resistance values. The use of basic meter as DC ammeter, DC voltmeter and ohmmeter is explained in examples b ...
instruction manual - Calright Instruments
instruction manual - Calright Instruments

... Before using this meter, read all safety information carefully. In this manual the word "WARNING" is used to indicate conditions or actions that may pose physical hazards to the user. The word "CAUTION" is used to indicate conditions or actions that may damage this instrument. • Always follow indust ...
Addendum to kWh Meter Installation Instructions For Use - E-Mon
Addendum to kWh Meter Installation Instructions For Use - E-Mon

... the 0~5 amp signal, the Current Sensors are installed on the CT secondary lead. A set of 25 amp sensors is used in this application. These sensors have the high voltage CT secondary lead passed through them five (5) times by looping the wire as shown in the drawing. This allows a direct conversion o ...
Digital VOR
Digital VOR

... The Localizer operated similar to the DVOR in that the DVOR displays 360 radical lines around the VOR station. The localizer displays a smaller segment of then lines each side of the runway centerline. Each line isequivalent to a 1/2 dot increment on a standard CDI, the full CDI needle deflection is ...
4100 Series - Magnetic Sciences
4100 Series - Magnetic Sciences

... Basic ELF gaussmeter operational procedure is found in Section 1 of this manual. When conducting ELF field measurements, one should take advantage of the features the 4100 series meters have to offer. When conducting a measurement the user can use the RELATIVE feature to compare field strength betwe ...
Meter - AnaLog Services, Inc.
Meter - AnaLog Services, Inc.

... Power and Pilot Light Connections The CCL Meter (Revision A) PCB is designed to be powered by the vehicle 12 volt battery. It can also be powered by a DC power supply in a portable panel, and from other voltage levels so long as the proper current limiting resistor (R-1) is used. It is philosophical ...
Power Monitoring Technology
Power Monitoring Technology

... although sample rate is commonly considered for accurate measurement, other design factors that can affect a monitor’s overall performance are often overlooked. Figure 1 shows approximately 1½ cycles of a voltage waveform. Sample points, shown for reference only, represent a sample rate of 16 sample ...
Measuring vibration using sound level meter Nor140
Measuring vibration using sound level meter Nor140

... Most sound level meters and sound analysers can be used for vibration measurements, even if they do not provide absolute (linear) units in the display. To simplify the description, this application note describes the use of the handheld sound level meter Norsonic Nor140. However, the described princ ...
Ultrasonic level measuring device, non
Ultrasonic level measuring device, non

... The transducer of the ultrasonic measuring device emits short ultrasonic pulses, at 55 kHz to the measured product. These pulses are reflected by the medium surface and received by the transducer as echoes. The running time of the ultrasonic pulses from emission to reception is proportional to the d ...
DS2000UBLA-1HS v3.4.2016
DS2000UBLA-1HS v3.4.2016

... Fluxgate, closed loop compensated technology with fixed excitation frequency and second harmonic zero flux detection for best in class accuracy and ...
達松發可動線圈 (D`Arsonval movement)
達松發可動線圈 (D`Arsonval movement)

... current quantity into a thermal (heat) quantity, effectively squaring the values in real-time. The ...
Challenges in developing Smart Meters
Challenges in developing Smart Meters

... residence, business, or an electrically powered device. Electricity meters are typically calibrated in billing units, the most common one being the kilowatt hour. First energy meter was produced during 1889, Earlier meters were based on electromechanical form, using an induction disk whose rotationa ...
Nikon DP-1 meter adjustment and cleaning procedure
Nikon DP-1 meter adjustment and cleaning procedure

... meter movement is centered when it has about 0.025 volts across it, at about 16 micro-amps. When the test button is pressed, current flows from battery negative, through test adjust trimpot, through the switch and then through the meter to case ground (battery positive. CAUTION: Note that .025 volts ...
DMS-EB - Murata Power Solutions
DMS-EB - Murata Power Solutions

... digit meters operating in the single-ended mode (SG5 closed) using the meter's internal reference (SG13 closed). This configuration is the most common and works well for most simple voltage measurements. Many of the applications described below apply to both DMS-30 and DMS-40 meters. However, Applica ...
06-1-فراس الحجه و عبد الرحمن علان
06-1-فراس الحجه و عبد الرحمن علان

... meters have very fine internal wires that flex to enable the needle to move. Because the wires are fine, they carry only a very small current. Therefore, the current in the meter must be a tiny fraction of the total current to be measured . In order to obtain an accurate reading of the current flow ...
What is Special Energy Meter(SEM)?
What is Special Energy Meter(SEM)?

... Metering Management Initial/one time activities  Choose the category of meter  Selection of meter  Installation of meters in strategic locations  Deciding status of meters as Main, Check and Stand-by meters ...
1702-07-Engineering-Spec-FCS-M-LPT-P-TCO-NO2B-ESH
1702-07-Engineering-Spec-FCS-M-LPT-P-TCO-NO2B-ESH

... Multi-Channel Gas Detection System for Carbon Monoxide (CO), Nitrogen Dioxide (NO2), TVOCs & Propane (C3H8) Provide a wall mount, self-contained, field programmable central control panel with back-lit, LCD digital display, LED alarm indication, and door mounted 90 dB audible alarms with silence / ac ...
testequip-intro
testequip-intro

... Part 3: Other Measurements: Meter setting “mV” (1) Turn the multimeter to the ” mV” Voltage setting. Tightly grasp one meter lead in each hand and measure the voltage from your body. Record the voltage below. AC voltage generated from your body: ___________________ (2) Now measure the AC voltage fro ...
Quotations - School Of Engineering
Quotations - School Of Engineering

... plunger weiging 47.5 gram for testing kit bituminus product, and with 50 gram and 100 gram weights, including cone and penetration unit. in-built timer to control duration of penetration preset for 5 seconds and to be provided with levelling screws, penetration needle, transfer dish and aluminium sa ...
Functional_Decomposition
Functional_Decomposition

... The system must  Accept an audio input signal source with a maximum input voltage of 0.5V peak.  Have adjustable volume control between zero volume and the maximum volume level.  Deliver a maximum of 50W to an 8 speaker.  Be powered by a standard 120V 60Hz AC outlet. ...
Functionality
Functionality

... The system must  Accept an audio input signal source with a maximum input voltage of 0.5V peak.  Have adjustable volume control between zero volume and the maximum volume level.  Deliver a maximum of 50W to an 8 speaker.  Be powered by a standard 120V 60Hz AC outlet. ...
< 1 ... 24 25 26 27 28 29 30 31 32 ... 36 >

Peak programme meter



A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report