
THAT Corporation Design Note 108
... Iin 0dB = 1.13 % I t . If we set Vin0dB = -10dBu as the reference input signal voltage, then we can calculate the input reference current as ...
... Iin 0dB = 1.13 % I t . If we set Vin0dB = -10dBu as the reference input signal voltage, then we can calculate the input reference current as ...
9600-3002-2 C CALMU3+ Manual A4.p65
... CALMU3+ meters are configured at manufacture to suit the intended application. This includes programming arrangements for tariff as well for meter scaling. CALMU3+ meters are usually supplied with ‘primary scaling’ so that the metering values reported are scaled up to the level seen at the load. The ...
... CALMU3+ meters are configured at manufacture to suit the intended application. This includes programming arrangements for tariff as well for meter scaling. CALMU3+ meters are usually supplied with ‘primary scaling’ so that the metering values reported are scaled up to the level seen at the load. The ...
Deltec CA1 Product Brief (pdf download)
... new pre-amplifier that is radical and innovative. It represents a true breakthrough in subjective performance producing a level of transparency and warmth previously unavailable at any price. We urge serious audiophiles to audition the CA1 and enter into this new realm of believability. The only way ...
... new pre-amplifier that is radical and innovative. It represents a true breakthrough in subjective performance producing a level of transparency and warmth previously unavailable at any price. We urge serious audiophiles to audition the CA1 and enter into this new realm of believability. The only way ...
Model 3206G - Radian Research
... the manufacturer’s supplied module. The Model 3206G can even be used as a simple meter warm-up station. The Model 3206G is a stand-alone unit that requires no additional PC or hardware for general operation. Watthour Engineering’s advanced Smart Socket™ technology allows you to insert a meter into t ...
... the manufacturer’s supplied module. The Model 3206G can even be used as a simple meter warm-up station. The Model 3206G is a stand-alone unit that requires no additional PC or hardware for general operation. Watthour Engineering’s advanced Smart Socket™ technology allows you to insert a meter into t ...
SP-35X Signal Powered DC Volt Meter 3 1/2 Digit 0.48” LCD
... The SP-35X, when used with its companion meter SP-35XMV, is an elegant solution to the problem of measuring and displaying voltage and current in DC powered systems. To simplify the installation when used together, specify the stackable case option to mount both meters in a single cutout. Our custom ...
... The SP-35X, when used with its companion meter SP-35XMV, is an elegant solution to the problem of measuring and displaying voltage and current in DC powered systems. To simplify the installation when used together, specify the stackable case option to mount both meters in a single cutout. Our custom ...
62 Counters, Panel Meters, Tachometers and
... Timers are used in applications where time itself is the main focus. These include simple knowledge of how long a machine has been running to determine machine maintenance, for example, (elapsed time) to knowing when to change an elevator cable (cable life and safety). Timers generally have the abil ...
... Timers are used in applications where time itself is the main focus. These include simple knowledge of how long a machine has been running to determine machine maintenance, for example, (elapsed time) to knowing when to change an elevator cable (cable life and safety). Timers generally have the abil ...
English User`s Manual
... 2. Turn the meter off and remove the rear battery compartment screw. 3. Lift off the battery compartment cover and replace the two 1.5V AA cells. 4. Replace the compartment cover and secure the screw. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumu ...
... 2. Turn the meter off and remove the rear battery compartment screw. 3. Lift off the battery compartment cover and replace the two 1.5V AA cells. 4. Replace the compartment cover and secure the screw. You, as the end user, are legally bound (Battery ordinance) to return all used batteries and accumu ...
Type B - Eaton
... • Meterpacks for standard type B standard distribution boards • 120A direct connected or CT fed versions available for 125/250A applications • Aids compliance with part L2 of building regulations in England and Wales • 120A version is OFGEM certified and suitable for billing applications where requi ...
... • Meterpacks for standard type B standard distribution boards • 120A direct connected or CT fed versions available for 125/250A applications • Aids compliance with part L2 of building regulations in England and Wales • 120A version is OFGEM certified and suitable for billing applications where requi ...
RH1021-7
... 2-pole lowpass filter at 1kHz. The resulting output is full wave rectified and then integrated for a fixed period, making the final reading an average as opposed to RMS. Correction factors are used to convert from average to RMS and to correct for the nonideal bandpass of the filters. Peak-to-peak n ...
... 2-pole lowpass filter at 1kHz. The resulting output is full wave rectified and then integrated for a fixed period, making the final reading an average as opposed to RMS. Correction factors are used to convert from average to RMS and to correct for the nonideal bandpass of the filters. Peak-to-peak n ...
HOW tO uSe a multimeteR G
... Set the meter range to amps – highest range first if not auto ranging. Connect the leads to the correct jacks on the meter. Note that often there’s a separate jack for measuring current at 10 amps. ...
... Set the meter range to amps – highest range first if not auto ranging. Connect the leads to the correct jacks on the meter. Note that often there’s a separate jack for measuring current at 10 amps. ...
Clamp Meter - East Hills Instruments
... Use only type AA batteries, properly installed in the Meter case, to power the Meter. When measuring current with the Jaw, keep fingers behind the Tactile Barrier. See "The Meter" . To avoid false readings that can lead to electrical shock and injury, replace the batteries as soon as the low batter ...
... Use only type AA batteries, properly installed in the Meter case, to power the Meter. When measuring current with the Jaw, keep fingers behind the Tactile Barrier. See "The Meter" . To avoid false readings that can lead to electrical shock and injury, replace the batteries as soon as the low batter ...
pccreditcopymate.
... another copy. In another scenario, if the customer were to insert a 20p, he/she would be allowed to make 3 copies in a row, before CopyMate switched off the photocopier. This would leave a balance of 2p in memory, so if he/she inserted another 4p, they could make another copy. As said before any bal ...
... another copy. In another scenario, if the customer were to insert a 20p, he/she would be allowed to make 3 copies in a row, before CopyMate switched off the photocopier. This would leave a balance of 2p in memory, so if he/she inserted another 4p, they could make another copy. As said before any bal ...
Basic electric Tools and Tackles
... has a very low resistance and is very sensitive, with scales down to 50 µA. More expensive digital multimeters can equal or better than this performance. Most modern multimeters are digital and traditional analogue types are destined to become obsolete. ...
... has a very low resistance and is very sensitive, with scales down to 50 µA. More expensive digital multimeters can equal or better than this performance. Most modern multimeters are digital and traditional analogue types are destined to become obsolete. ...
Test equipment : Clamp-on
... - Capacitance; For motor-run and motor-start capacitors. - And more; blackligth for viewing display in the dark true RMS for true power calculations. LED and beeper turn on to indicate you’ve touched potentially dangerous voltage. Continuity indicated by LED and beeper Hold saves readings so you can ...
... - Capacitance; For motor-run and motor-start capacitors. - And more; blackligth for viewing display in the dark true RMS for true power calculations. LED and beeper turn on to indicate you’ve touched potentially dangerous voltage. Continuity indicated by LED and beeper Hold saves readings so you can ...
View Super Stereo Product Manual
... slower attack time will allow more transients to be passed without gain reduction; a faster attack will tend to reduce transient levels. A wide range of tonal variation is possible as a result. Attack times are approximate and are measured in milliseconds. time settings. This controls how quickly fu ...
... slower attack time will allow more transients to be passed without gain reduction; a faster attack will tend to reduce transient levels. A wide range of tonal variation is possible as a result. Attack times are approximate and are measured in milliseconds. time settings. This controls how quickly fu ...
AH979H
... Voltage, Level, and Noise meter function also provided. This instrument is most suitable for testing instrument for maintenance and adjustment of various wireless equipment, broadcast equipment, studio equipment. ...
... Voltage, Level, and Noise meter function also provided. This instrument is most suitable for testing instrument for maintenance and adjustment of various wireless equipment, broadcast equipment, studio equipment. ...
1. WHAT IS METER
... Metering Management Initial/one time activities Choose the category of meter Selection of meter Installation of meters in strategic locations Deciding status of meters as Main, Check and Stand-by meters ...
... Metering Management Initial/one time activities Choose the category of meter Selection of meter Installation of meters in strategic locations Deciding status of meters as Main, Check and Stand-by meters ...
Datasheet
... * General purpose Type K probe included does not measure full range of meter capability. Specifications on next page. ...
... * General purpose Type K probe included does not measure full range of meter capability. Specifications on next page. ...
Definitions
... Responsible for the provision and ownership of the meter and metering devices, installation of meter, testing of the meter for manufacturer specifications, meter calibration, testing of the meter for proper installation and functionality, meter maintenance, and remote meter reading. All non-PECO met ...
... Responsible for the provision and ownership of the meter and metering devices, installation of meter, testing of the meter for manufacturer specifications, meter calibration, testing of the meter for proper installation and functionality, meter maintenance, and remote meter reading. All non-PECO met ...
Document
... will read a very low resistance such as zero ohms. If there is no continuity between two points, the ohmmeter will read infinite ohms. ...
... will read a very low resistance such as zero ohms. If there is no continuity between two points, the ohmmeter will read infinite ohms. ...
ppt_ch08
... will read a very low resistance such as zero ohms. If there is no continuity between two points, the ohmmeter will read infinite ohms. ...
... will read a very low resistance such as zero ohms. If there is no continuity between two points, the ohmmeter will read infinite ohms. ...
DEM 1296-144 23 cm Transverter, and Transverter Kits
... version. Substitute 28 for the 144 in the part number. The 1296-144 transverter has both a RF and IF switch built in to the circuit board. The RF switch may be bypassed for separate TX and RX ports for 23 cm. The connectors are SMA only for the split TR configuration and a type “N” female for the co ...
... version. Substitute 28 for the 144 in the part number. The 1296-144 transverter has both a RF and IF switch built in to the circuit board. The RF switch may be bypassed for separate TX and RX ports for 23 cm. The connectors are SMA only for the split TR configuration and a type “N” female for the co ...
data sheet data sheet - National Model Railroad Association
... Various Electronic Supply Catalogs ...
... Various Electronic Supply Catalogs ...
COULOMB METER - Digital
... The IEC Coulomb meter is a low cost and robust digital instrument that can replace the traditional electroscope. It measures electrical charge or the quantity of electricity. By definition, one Coulomb is the quantity of electricity equivalent to 1x amp second (one amp flowing for exactly one second ...
... The IEC Coulomb meter is a low cost and robust digital instrument that can replace the traditional electroscope. It measures electrical charge or the quantity of electricity. By definition, one Coulomb is the quantity of electricity equivalent to 1x amp second (one amp flowing for exactly one second ...
PM1000 series power meter and DM6000 series
... Accurate metering The meter conforms to accuracy class 1.0 as per IEC 62052-11 and IEC 62053-21. Easy-to-read display The bright, alphanumeric, 15mm-high LED display provides three lines for measurement values with four digits per line. The display auto-scales for Kilo, Mega and Giga values. Auto sc ...
... Accurate metering The meter conforms to accuracy class 1.0 as per IEC 62052-11 and IEC 62053-21. Easy-to-read display The bright, alphanumeric, 15mm-high LED display provides three lines for measurement values with four digits per line. The display auto-scales for Kilo, Mega and Giga values. Auto sc ...
Peak programme meter

A peak programme meter (PPM) is an instrument used in professional audio for indicating the level of an audio signal.There are many different kinds of PPM. They fall into broad categories:True peak programme meter. This shows the peak level of the waveform no matter how brief its duration.Quasi peak programme meter (QPPM). This only shows the true level of the peak if it exceeds a certain duration, typically a few milliseconds. On peaks of shorter duration, it will indicate less than the true peak level. The extent of the shortfall is determined by the 'integration time'.Sample peak programme meter (SPPM). This is a PPM for digital audio which shows only peak sample values, not the true waveform peaks (which may fall between samples and be up to 3 dB higher in amplitude). It may have either a 'true' or a 'quasi' integration characteristic.Over-sampling peak programme meter. This is a sample PPM in which the signal has first been over-sampled, typically by a factor of four, to alleviate the problem with a basic sample PPM.In professional usage, where consistent level measurements are needed across an industry, audio level meters often comply with a detailed formal standard. This ensures that all meters that comply with the standard will give the same indication on a given audio signal. The principal standard for PPMs is IEC 60268-10. It describes two different quasi-PPM designs which have their roots in meters originally developed in the 1930s for the AM radio broadcasting networks of Germany (Type I) and the United Kingdom (Type II).The term Peak Programme Meter usually refers to these IEC-specified types and similar designs.PPMs were originally designed for monitoring analogue audio signals but are now also used with digital audio.PPMs do not provide effective loudness monitoring. Newer types of meter do, and there is now a push within the broadcasting industry to move away from traditional level meters such as those featured in this article to two new types: loudness meters based on EBU Tech. 3341 and oversampling true PPMs. The former would be used to standardise broadcast loudness to −23 LUFS and the latter to prevent digital clipping.