• Study Resource
  • Explore
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
the overview brochure - Kniel System
the overview brochure - Kniel System

Megablock section-Rev8-CCH.indd
Megablock section-Rev8-CCH.indd

... Megablocks are DIN-rail mounted passive hubs for FOUNDATION™ fieldbus networks. They connect several field devices to the network trunk cable and provide short circuit protection to the segment. Megablocks minimize hand wiring and allow individual devices to be added to and removed from the segment ...
Data Sheet 85001-0640 - Edwards | Fire Alarm Systems, Life Safety
Data Sheet 85001-0640 - Edwards | Fire Alarm Systems, Life Safety

... Programming and Field Configuration Each AB4G base uses the same address and programming label as the detector it supports. AB4G sounder bases can be set to simply operate according to the state of its detector, or configured through system programming to operate in conjunction with all sounder base ...
MAX5811 10-Bit, Low-Power, 2-Wire Interface, Serial, Voltage-Output DAC General Description
MAX5811 10-Bit, Low-Power, 2-Wire Interface, Serial, Voltage-Output DAC General Description

... impedance. Other features include an internal precision Rail-to-Rail® output buffer and a power-on reset (POR) circuit that powers up the DAC in the 100kΩ power-down mode. The MAX5811 features a double-buffered I2C-compatible serial interface that allows multiple devices to share a single bus. All l ...
LMG5200 80V, 10A GaN Half-Bridge Power Stage
LMG5200 80V, 10A GaN Half-Bridge Power Stage

... × 2 mm lead-free package and can be easily mounted on PCBs. The TTL logic compatible inputs can withstand input voltages up to 12 V regardless of the VCC voltage. The proprietary bootstrap voltage clamping technique ensures the gate voltages of the enhancement mode GaN FETs are within a safe operati ...
Aalborg Universitet A Slow-Charge Fast-Discharge Technique
Aalborg Universitet A Slow-Charge Fast-Discharge Technique

... MPULSE radio ultra wideband (IR-UWB) has been considered a promising technology for short range applications with stringent power consumption requirements, such as battery-less wireless sensor networks (WSN) based on energy harvesting [1], [2]. In an IR-UWB system the pulse generator is the key comp ...
Wind Power Facility Guide to the Technical Requirements Revision 0 November 30, 2004
Wind Power Facility Guide to the Technical Requirements Revision 0 November 30, 2004

... Figure 5.3 – Example Reactive Power Ramp with fixed and variable reactive power devices...........................11 Figure 5.4 – Example where reactive current compensation would be required.................................................13 Figure 5.5 –Example of a VRS response to a system voltage ...
Desire Series D22 Installation Guide
Desire Series D22 Installation Guide

... A termination board is incorporated into the mounting plate for installation onto a voltage-separated junction box (junction box provided by others, voltage barrier provided by ETC) and provides termination for control wiring. • Connection of the D22 data cable to a provided screw-down connector, wh ...
MWS Switch Drop (SD)
MWS Switch Drop (SD)

... circuit. Switch Drops may be installed during rough-in or renovations. MWS Extender Cables bring power from starters to the first Switch Drop and between consecutive Switch Drops. ...
Aalborg Universitet A 3-10 GHz IR
Aalborg Universitet A 3-10 GHz IR

... MPULSE radio ultra wideband (IR-UWB) has been considered a promising technology for short range applications with stringent power consumption requirements, such as battery-less wireless sensor networks (WSN) based on energy harvesting [1], [2]. In an IR-UWB system the pulse generator is the key comp ...
Chapter 8 Electrical Power 8.1 Introduction
Chapter 8 Electrical Power 8.1 Introduction

... protection using separate and independent current and control circuits. Normal and alternate preferred power conductors located between the Fermi 3 UATs and RATs and the 345 kV switchyard buses are protected by dual high-speed current differential schemes. The 345 kV switchyard circuit breakers are ...
BD5426MUV
BD5426MUV

99% Efficiency True-Bridgeless Totem-Pole PFC
99% Efficiency True-Bridgeless Totem-Pole PFC

DS1813 5V EconoReset with Pushbutton  GENERAL DESCRIPTION
DS1813 5V EconoReset with Pushbutton GENERAL DESCRIPTION

... The DS1813 provides the functions of detecting out-of-tolerance power-supply conditions and warning a processor-based system of impending power failure. When VCC is detected as out-of-tolerance, the RST signal is asserted. On power-up, RST is kept active for approximately 150ms after the power suppl ...
Arc Series
Arc Series

04_FINAL_AVR_2009 (PPTmin)
04_FINAL_AVR_2009 (PPTmin)

... voltage of 0.7 ± 0.1 Volts, please raise your hand. - Ensure that your partner has his/her ESD band on and have him/her place his/her finger on the sensor. ...
The approximation scheme for peak power driven voltage partitioning
The approximation scheme for peak power driven voltage partitioning

MAX3800 3.2Gbps Adaptive Equalizer and Cable Driver General Description
MAX3800 3.2Gbps Adaptive Equalizer and Cable Driver General Description

... communications applications. The driver features differential current-mode logic (CML) inputs and outputs as well as adjustable output amplitude. The equalizer includes differential CML data inputs and outputs, a loss-of-signal (LOS) output, and a cable integrity monitor (CIM) output. The adaptive c ...
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org
IOSR Journal of Electronics & Communication Engineering (IOSR-JECE) ISSN : www.iosrjournals.org

AN4705, Low-Power Wireless Charger Transmitter Design
AN4705, Low-Power Wireless Charger Transmitter Design

Energy Management
Energy Management

... Current measurements carried out by means of external current transformers and voltage measurements carried out either by means of direct connection or by means of potential transformers. EM21-72D is provided, as standard, with a pulsating output for active energy retransmission. In addition a 2-wir ...
– V30 Touchlock Technical Installation Manual
– V30 Touchlock Technical Installation Manual

... operate from +8vDC to +18vDC, ideally a regulated +12vDC supply. Do not connect to AC or Mains power. ...
Link layer addressing and Ethernet
Link layer addressing and Ethernet

Guide to Motor Caravan Distributed Intelligence System
Guide to Motor Caravan Distributed Intelligence System

... ones is the possibility of data transmission on a special cable called “bus”. The data in question are those associated with the vehicle operating parameters, such as voltage of the batteries, or the level of a tank or certain data for diagnosing the correct operation of all the devices on board. Th ...
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676
IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) ISSN: 2278-1676

... 850KW respectively. In order to reduce the weight of the aircraft electric power should be delivered at a high voltage With low current and low conduction losses this technology leads to simpler Equipment and enables significant energy saving device. But request high power density DC/DC converter. F ...
< 1 ... 153 154 155 156 157 158 159 160 161 ... 576 >

Power over Ethernet



Power over Ethernet or PoE describes any of several standardized or ad-hoc systems which pass electrical power along with data on Ethernet cabling. This allows a single cable to provide both data connection and electrical power to devices such as wireless access points or IP cameras. Unlike standards such as Universal Serial Bus which also power devices over the data cables, PoE allows long cable lengths. Power may be carried on the same conductors as the data, or it may be carried on dedicated conductors in the same cable.There are several common techniques for transmitting power over Ethernet cabling. Two of them have been standardized by IEEE 802.3. Since only two of the four pairs are needed for 10BASE-T or 100BASE-TX, power may be transmitted on the unused conductors of a cable. In the IEEE standards, this is referred to as Alternative B. Power may also be transmitted on the data conductors by applying a common-mode voltage to each pair. Because twisted-pair Ethernet uses differential signalling, this does not interfere with data transmission. The common mode voltage is easily extracted using the center tap of the standard Ethernet pulse transformer. This is similar to the phantom power technique commonly used for powering audio microphones. In the IEEE standards, this is referred to as Alternative A.In addition to standardizing existing practice for spare-pair and common-mode data pair power transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD). This signaling allows the presence of a conformant device to be detected by the power source, and allows the device and source to negotiate the amount of power required or available. Up to a 25.5 watts is available for a device.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report