• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
ADG719 数据手册DataSheet下载
ADG719 数据手册DataSheet下载

... Additions to PRODUCT HIGHLIGHTS .......................................................................................................................................1 Changes to SPECIFICATIONS ......................................................................................................... ...
Two-Wire Current Loop Powered Indicators
Two-Wire Current Loop Powered Indicators

... (±1999 active counts) can present the process variable in either percentage or directly in engineering units. The indicators are powered directly from the current loop with a volt drop of less than 2.5 volts, and a power consumption of 2. 5 mW at 1 mA. The TX-83 and TX-84 are watertight to 5 PSIG, a ...
MAX14984 Enhanced VGA Port Protector with Monitor General Description
MAX14984 Enhanced VGA Port Protector with Monitor General Description

... monitor is detected. A switched 5V output provides up to 55mA to the VGA port in addition to normal VGA signals. The MAX14984 features a single active-low enable input to control two 5V USB switches. Each switch supplies 500mA of current with less than 250mV drop from VCC, and is protected against s ...
BS 6651 BS EN 62305
BS 6651 BS EN 62305

ELECTRICIAN_New_Syll
ELECTRICIAN_New_Syll

... Verification of open circuit Kirchoff’s Laws and applications. and closed circuit network. Wheatstone bridge principle and its applications . Measuring unknown resistance using Wheatstone bridge ...
Inductive and Capacitive Reactance
Inductive and Capacitive Reactance

... At the beginning of the first quarter-cycle (0º to 90º) the voltage has just passed through zero and is increasing in the positive direction. Since the zero point is the steepest part of the sine wave, the voltage is changing at its greatest rate. The charge on a capacitor varies directly with the ...
Making Resistance Spot Welding Safer
Making Resistance Spot Welding Safer

Relaying Current Transformer Application
Relaying Current Transformer Application

Vcc + Vss - Renesas E
Vcc + Vss - Renesas E

... • Simulation showed that in Pattern 1 the common-mode voltage swing of Vss was opposite the swing of Vcc but larger, an unbalance that caused emissions in the wiring harness • In Pattern 2, the swing of Vss was equal and opposite to that of Vcc, thus minimizing the common-mode voltage and current — ...
Leakage Biased PMOS Sleep Switch Dynamic Circuits
Leakage Biased PMOS Sleep Switch Dynamic Circuits

... The active power consumption of domino circuits is shown in Fig. 5. In dual- nMOS and dual- LB circuits, two pMOS transistors are placed in series in the pull-up path of the output inverter. Furthermore, P2 has a high . The driving capability of the output inverter is, therefore, degraded. The physi ...
Gauss`s Law - KCSE Online
Gauss`s Law - KCSE Online

MN132005EN/ Old S240-33-1
MN132005EN/ Old S240-33-1

... The two- or three-phase MagneX interrupter is mounted through the transformer tank wall for side wall mount. Use 2.25" diameter hole size with anti-rotation nibs (.156" radius), refer to Figure 3. Nibs (either one or two) must be on the horizontal centerline of the tank hole ±5 degrees. Refer to Fig ...
Flash light and recharging device for the battery thereof
Flash light and recharging device for the battery thereof

... housed in a portable casing that is separate positive and negative plates or electrodes may be of any desired or‘ preferred form from the casing of the ?ashlight but of such size that it may be conveniently carried about and have their terminals suitably connected with the portable lighting device a ...
Inspecting Electrical
Inspecting Electrical

APT Generator Quick Connection Switchboard (FS Series)
APT Generator Quick Connection Switchboard (FS Series)

MAX® 5500 ACRegenerator™ Owner`s Manual
MAX® 5500 ACRegenerator™ Owner`s Manual

Power Module Reliability - Mitsubishi Electric Corporation
Power Module Reliability - Mitsubishi Electric Corporation

Online Full Text
Online Full Text

... Also exceeding the capability of an arrester will crack or puncture the metal-oxide disk(s), in effect reduce the arrester internal electrical resistance, thus, the condition will limit the arrester’s ability to survive future system conditions. This condition does not jeopardize the insulation prot ...
air circuit breaker up to 6300a spec
air circuit breaker up to 6300a spec

... 2.7.1 All electrical auxiliaries including the motor spring charging mechanism shall be field adaptable without adjustment or the necessity for any tool (except a screwdriver). They shall be fitted into a compartment which under normally loaded conditions has no metalwork energized from the main pol ...
TE200A Power controllers Two-phase control of three
TE200A Power controllers Two-phase control of three

lecture notes
lecture notes

... The measurement methods can be analog or digital methods, deflection or null methods, active or passive methods, direct or indirect methods and absolute or secondary methods. Measurement generally involves an instrument as a physical means of determining an unknown quantity or a variable called the ...
AVR040: EMC Design Considerations
AVR040: EMC Design Considerations

UCC25701 数据资料 dataSheet 下载
UCC25701 数据资料 dataSheet 下载

... The circuit will start at this point. IVDD will increase from the start up value of 130mA to the run value of 750mA. The capacitor on SS is charged with a 18mA current. When the voltage on SS is greater than 0.8V, output pulses can begin, and supply current will increase to a level determined by the ...
WIRING DIAGRAM INFORMATION
WIRING DIAGRAM INFORMATION

Unit 4 Electrical Principles and Technologies - Topic 6
Unit 4 Electrical Principles and Technologies - Topic 6

< 1 ... 62 63 64 65 66 67 68 69 70 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.