• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
CA320002EN
CA320002EN

... sections of underground cable systems. These faulted circuit indicators (FCIs) can be used on both 200 A separable connectors and 600 A terminators with a voltage test point. The removable sleeve allows for use on major manufacturers’ loadbreak elbows. S.T.A.R. TPR FCIs feature a stored energy desig ...
Turkey Point Units 6 & 7 COL Application Part 2 — FSAR
Turkey Point Units 6 & 7 COL Application Part 2 — FSAR

... FPL uses a real-time contingency analysis computer program that is used by FPL’s transmission system operators in determining the security level of the transmission system by performing an analysis using a predefined set of contingency criteria (e.g., single contingency). The computer program simula ...
Film Capacitors - Power Factor Correction - MKP440-D-15
Film Capacitors - Power Factor Correction - MKP440-D-15

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
TR41.3.6-02-11-007-(word) - Telecommunications Industry
TR41.3.6-02-11-007-(word) - Telecommunications Industry

165-260
165-260

... Software-based Close-inhibit, CLOSE inhibited on relay fail Software-based Close-inhibit, CLOSE enabled on relay fail Trip/Close 125VDC/120VAC LED Lamps for Trip and Close Status Lamp 48 VDC LED Lamps for Trip and Close Status Type 24VDC LED Lamps for Trip and Close Status 48VDC Incandescent Lamps f ...
Lecture 21: IDDQ Current Testing
Lecture 21: IDDQ Current Testing

Distribution Transformers and EMC
Distribution Transformers and EMC

Manual Motor Controllers (MMPs)
Manual Motor Controllers (MMPs)

... As Recognized To UL 1077 With applications similar to supplemental fuses, these supplementary protectors, often referred to as mini-circuit breakers, cannot be used as a branch circuit protective device. As such they cannot provide motor, motor circuit, or group motor protection. They can only be us ...
Evaluates:  MAX117/MAX118 MAX117 Evaluation Kit _______________General Description ____________________________Features
Evaluates: MAX117/MAX118 MAX117 Evaluation Kit _______________General Description ____________________________Features

... evaluation board for the 8-bit, 8-channel, +3V MAX117 analog-to-digital converter. Channel selection can be controlled by switches located on the board or by userprovided logic-level signals. An on-board oscillator provides continuous conversions, and the conversion results appear on the LED output ...
Using Digi Products in the Real World: Issues of
Using Digi Products in the Real World: Issues of

... protection. They use heavy surge devices to burn and bypass the majority of the surge energy. These devices, however, are coarse; that is, not very accurate. They may fire at any voltage between 150 to 400 volts, which means that the attached device still needs to handle a low-energy 400-volt surge. ...
DC/DC converter
DC/DC converter

... optocoupler. The LED drive provides a 10-20mA when on, and provides a low impedance when off. The circuit integrated is shown below. VFLT ...
MAX16050/MAX16051 Voltage Monitors/Sequencer Circuits with
MAX16050/MAX16051 Voltage Monitors/Sequencer Circuits with

SAGs and SWELLs
SAGs and SWELLs

... bus voltage will return to normal. Distribution breakers typically allow faults to remain longer than transmission breakers and typically reclose slower, in order to allow time for the protective equipments (such as fuses) that are downstream to function. The recloser will open, and then reclose int ...
Atmel LED Driver-MSL3082
Atmel LED Driver-MSL3082

... to offer easy synchronization for use in LCD TV backlight applications. Up to sixteen devices may be connected together to drive a large number of LED strings in a system. The drivers provide multiple methods of controlling LED brightness, through both peak current control and pulse width control of ...
MAX14838/9 - Maxim Part Number Search
MAX14838/9 - Maxim Part Number Search

Components of Training for Bell Atlantic
Components of Training for Bell Atlantic

... A good ground is an important part of an installation for all of the following reasons EXCEPT: a. It helps reduce damage in case of a lightning hit. b. It eliminates any chance of personnel being electrocuted if a short occurs to a frame or cabinet. c. It protects sensitive electronics from electric ...
Motors and Generators
Motors and Generators

... • pump the washers, raise the radio aerial, adjust the driver’s seat ..... They can even power a whole car: but they all rely on the same physical principle. ...
E_M_4_teachers
E_M_4_teachers

... manner the coil can be made to rotate for quite a while. If the circuit were not broken during one half of the revolution of the coil, the coil would experience a torque in the opposite direction during this half cycle. In this case the coil would not rotate but would rock back and forth. This circu ...
Technical Standard – TS 130
Technical Standard – TS 130

Surge Protection Portfolio
Surge Protection Portfolio

... Scan the QR code for a handy checklist and see if any areas in your customers’ residences or facilities are unprotected. ...
RC Circuits 3.0 - University of Michigan–Dearborn
RC Circuits 3.0 - University of Michigan–Dearborn

... This is a very common situation. In electronic devices that require dc voltages, the power supply typically provides only one or a few fixed voltage levels. There may be many parts of the circuitry that require voltage levels other than those few supplied. In your case, how do you get 4 V from the o ...
Safety Controller Safety Relay Output Module User's Manual (Hardware) WS0-4RO4002
Safety Controller Safety Relay Output Module User's Manual (Hardware) WS0-4RO4002

Isolation and Regulation Transformer Operating Principles and
Isolation and Regulation Transformer Operating Principles and

... C = capacitance in farads dv/dt = the rate change of voltage with respect to time As the capacitance increases, the current also increases for a constant dv/dt. And, as dv/dt increases, for a constant capacitance, the current will also increase. For a DC voltage, (a constant or unchanging voltage) d ...
vc 400-045 vectron elektronik manual
vc 400-045 vectron elektronik manual

Lightning Protection
Lightning Protection

... Protect buildings and structures from lightning induced surges traveling along incoming electric power and communications lines by installing surge arresters at electrical service entrances to divert these surges to earth. Protect electric equipment from lightning induced surges by following the rec ...
< 1 ... 66 67 68 69 70 71 72 73 74 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.