• Study Resource
  • Explore Categories
    • Arts & Humanities
    • Business
    • Engineering & Technology
    • Foreign Language
    • History
    • Math
    • Science
    • Social Science

    Top subcategories

    • Advanced Math
    • Algebra
    • Basic Math
    • Calculus
    • Geometry
    • Linear Algebra
    • Pre-Algebra
    • Pre-Calculus
    • Statistics And Probability
    • Trigonometry
    • other →

    Top subcategories

    • Astronomy
    • Astrophysics
    • Biology
    • Chemistry
    • Earth Science
    • Environmental Science
    • Health Science
    • Physics
    • other →

    Top subcategories

    • Anthropology
    • Law
    • Political Science
    • Psychology
    • Sociology
    • other →

    Top subcategories

    • Accounting
    • Economics
    • Finance
    • Management
    • other →

    Top subcategories

    • Aerospace Engineering
    • Bioengineering
    • Chemical Engineering
    • Civil Engineering
    • Computer Science
    • Electrical Engineering
    • Industrial Engineering
    • Mechanical Engineering
    • Web Design
    • other →

    Top subcategories

    • Architecture
    • Communications
    • English
    • Gender Studies
    • Music
    • Performing Arts
    • Philosophy
    • Religious Studies
    • Writing
    • other →

    Top subcategories

    • Ancient History
    • European History
    • US History
    • World History
    • other →

    Top subcategories

    • Croatian
    • Czech
    • Finnish
    • Greek
    • Hindi
    • Japanese
    • Korean
    • Persian
    • Swedish
    • Turkish
    • other →
 
Profile Documents Logout
Upload
MKK525-D-20-02 - B25673A5202A020
MKK525-D-20-02 - B25673A5202A020

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
Film Capacitors - Power Factor Correction - MKK525-D-20
Film Capacitors - Power Factor Correction - MKK525-D-20

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
AutomationNotebook Issue 5
AutomationNotebook Issue 5

Film Capacitors - Power Factor Correction - MKK440-D-30
Film Capacitors - Power Factor Correction - MKK440-D-30

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
Module 6: Spice
Module 6: Spice

Basic Wiring for Motor Contol
Basic Wiring for Motor Contol

William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER
William States Lee III Nuclear Station FSAR, Chapter 8 CHAPTER 8 ELECTRIC POWER

... rated for the ultimate load and fault current levels to which the switchyard might be exposed. The nominal continuous current ratings of the installed equipment (based on a nominal operating temperature of key elements at 90 Deg C) is 3000 amperes for the 230 kV switchyard and 4000 amperes for the 5 ...
Hardware Design Techniques
Hardware Design Techniques

Full-Text PDF
Full-Text PDF

... the performance of distance relays during wide area disturbances by preventing the operation of distance relays under dynamic load conditions. However, blocking the operation of the distance elements if a fault occurs at this time may result in a further degradation of the system conditions. The pap ...
2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10 Variable speed
2 1 3 4 5 6 7 8 9 10 2 1 3 4 5 6 7 8 9 10 Variable speed

... drives for a switching frequency of 2 to 16 kHz. These maximum lengths are given as examples only, as they vary depending on the stray capacitance of the motors and the cables used. If motors are connected in parallel, the sum of the cable lengths must be taken into account. ...
CleanEffects AccuClean Service and Repair
CleanEffects AccuClean Service and Repair

FAC-010-2 1 System Operating Limits Methodology for the Planning
FAC-010-2 1 System Operating Limits Methodology for the Planning

Transient Recovery Voltages During the Switching Under Out
Transient Recovery Voltages During the Switching Under Out

... The TRV requirements of IEEE Std C37.013 [4] regarding out-of-phase switching have been analysed based on three examples. The following conclusions may be drawn from the results obtained: § The out-of-phase TRV parameters and switching currents specified in [4] are restricted to an out-ofphase angle ...
AP IM 990-7283 MN01 EN.fm
AP IM 990-7283 MN01 EN.fm

... • Do not use the UPS as a safety disconnect. • Install appropriate strain reliefs (not supplied). Snap in type strain reliefs are recommended. • Strip wire insulation 20 mm (.75 inches) to expose the wire. Secure the exposed wire with the lug. • The jumpers use T25 Torx screws. • The terminal blocks ...
Slide No. 6 Common Electrical Hazards In Industries What is
Slide No. 6 Common Electrical Hazards In Industries What is

... Slide No. 10 ...
I/O - Renesas e
I/O - Renesas e

... © 2008, Renesas Technology America, Inc., All Rights Reserved ...
a 4/8 Channel Fault-Protected Analog Multiplexers ADG508F/ADG509F/ADG528F*
a 4/8 Channel Fault-Protected Analog Multiplexers ADG508F/ADG509F/ADG528F*

... series n-channel, p-channel, n-channel MOSFET structure, both device and signal source protection is provided in the event of an overvoltage or power loss. The multiplexer can withstand continuous overvoltage inputs from –40 V to +55 V. During fault conditions, the multiplexer input (or output) appe ...
Series 9180/ 9270 Power Amplifier
Series 9180/ 9270 Power Amplifier

Three-phase Transformers
Three-phase Transformers

Circuit Breaker Selection
Circuit Breaker Selection

... Quick interruption of short-circuit current is usually considered the primary function of a circuit breaker. The fault-current interrupting capability of Power/Vac circuit breakers is stated in threephase, symmetrical, rms AC amperes. Accordingly, calculation of the maximum available fault duty of a ...
B25667C4307A375
B25667C4307A375

... rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specificatio ...
19/23-5SS
19/23-5SS

... Internal components and circuit boards of the drive are live when the drive is connected to incoming power potential. Coming into contact with this voltage is extremely dangerous and will result in severe personal injury or death. The motor terminals U, V, W and the DC-link/brake resistor terminals ...
High Step-up Boost Converter Integrated With a Transformer
High Step-up Boost Converter Integrated With a Transformer

... Fig. 2. Proposed high step-up boost converter integrated with voltage-doubler as auxiliary step-up circuit, employing quasi-resonant operation. ...
convertion of galvanometer into voltmeter
convertion of galvanometer into voltmeter

VS10XX AppNote: Connecting analog outputs
VS10XX AppNote: Connecting analog outputs

< 1 ... 70 71 72 73 74 75 76 77 78 ... 353 >

Earthing system

In electricity supply systems, an earthing system or grounding system is circuitry which connects parts of the electric circuit with the ground, thus defining the electric potential of the conductors relative to the Earth's conductive surface. The choice of earthing system can affect the safety and electromagnetic compatibility of the power supply. In particular, it affects the magnitude and distribution of short circuit currents through the system, and the effects it creates on equipment and people in the proximity of the circuit. If a fault within an electrical device connects a live supply conductor to an exposed conductive surface, anyone touching it while electrically connected to the earth will complete a circuit back to the earthed supply conductor and receive an electric shock.A protective earth (PE), known as an equipment grounding conductor in the US National Electrical Code, avoids this hazard by keeping the exposed conductive surfaces of a device at earth potential. To avoid possible voltage drop no current is allowed to flow in this conductor under normal circumstances. In the event of a fault, currents will flow that should trip or blow the fuse or circuit breaker protecting the circuit. A high impedance line-to-ground fault insufficient to trip the overcurrent protection may still trip a residual-current device (ground fault circuit interrupter or GFCI in North America) if one is present. This disconnection in the event of a dangerous condition before someone receives a shock, is a fundamental tenet of modern wiring practice and in many documents is referred to as automatic disconnection of supply (ADS). The alternative is defence in depth, where multiple independent failures must occur to expose a dangerous condition - reinforced or double insulation come into this latter category.In contrast, a functional earth connection serves a purpose other than shock protection, and may normally carry current. The most important example of a functional earth is the neutral in an electrical supply system. It is a current-carrying conductor connected to earth, often, but not always, at only one point to avoid flow of currents through the earth. The NEC calls it a groundED supply conductor to distinguish it from the equipment groundING conductor. Other examples of devices that use functional earth connections include surge suppressors and electromagnetic interference filters, certain antennas and measurement instruments.Regulations for earthing system vary considerably among countries and among different parts of electric systems. Most low voltage systems connect one supply conductor to the earth (ground).People use an earthing system mainly for these applications: To protect a structure from lightning strike, directing the lightning through the earthing system and into the ground rod rather than passing through the structure. Part of the safety system of mains electricity, preventing problems associated with floating ground and sky voltage. The most common ground plane for large monopole antenna and some other kinds of radio antenna.Other, less common applications of earthing systems include: single-wire earth return. part of a system that powers small devices from sky voltage. one at each end of a ground dipole ELF antenna.
  • studyres.com © 2025
  • DMCA
  • Privacy
  • Terms
  • Report